My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
CANCELLED-118 W Stevens Ave - 20180880- DL - Plan
PBA
>
Building
>
ProjectDox
>
S
>
Stevens Ave
>
118 W Stevens Ave
>
CANCELLED-118 W Stevens Ave - 20180880- DL - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/31/2025 10:10:06 AM
Creation date
6/1/2025 12:11:11 PM
Metadata
Fields
Template:
Plan
Permit Number
20180880
Full Address
118 W Stevens Ave
Document Relationships
20180880 - Permit
(Permit - Plan)
Path:
\Building\Permits\S\Stevens Ave\118 W Stevens Ave
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
25
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Wind Load Cont. <br />110 mph ASCE 7‐16 Figure 26.5‐1B <br />C <br />1.0 ASCE 7‐16 Sec 26.8.2 <br />0.93 ASCE 7‐16 Table 26.10‐1 <br />0.85 ASCE 7‐16 Table 26.6‐1 <br />1.00 ASCE 7‐16 Table 26.9‐1 <br />24.42 psf <br />22.0 Degrees <br />1.5 Conservatively assuming all exposed <br />0.8 conservatively assuming 10 ft2 effective area <br />Uplift (W)Zone(1,2e) Zone(2r, 2n) Zone(3e) Zone(3r) <br />Fig. 30‐3‐2 GCp=‐1.3 ‐1.7 ‐1.7 ‐1.8 <br />Eq. 29.4‐7 P=qh(GCp)(γE)(γa)=‐38.10 ‐49.82 ‐49.82 ‐52.75 <br />GCp=0.6 Figure 30.3‐2 <br />P=qh(GCp)(γE)(γa)=9.67 Equation 29.4‐7 <br />Rafter Attachments: 0.6D+0.6W (CD=1.6) <br />Connection Check <br />Attachment max. spacing= 6 ft <br />5/16" Lag Screw Withdrawal Value= 266 lbs/in Table 12.2A ‐ NDS <br />2.5 in DFL Assumed <br />Prying Coefficient 1.4 <br />Allowable Capacity= 760 lbs <br />Zone Trib Width Area (ft) Uplift (lbs) Down (lbs) <br />Zone(1,2e)6 16.5 223.8 209.1 <br />Zone(2r, 2n)6 16.5 287.6 209.1 <br />Zone(3e)6 16.5 287.6 209.1 <br />Zone(3r)6 16.5 303.6 209.1 <br />Conservative Max=303.6 < 760 <br />CONNECTION IS OK <br />Risk Category = <br />KZ = <br />Kd = <br />Ke = <br />2. Embedment is measured from the top of the framing member to the tapered tip of a lag screw. <br />Embedment in sheading or other material does not count. <br />II <br />V= <br />Exposure = <br />1. Pv seismic dead weight is negligible to result in significant seismic uplift, therefore the wind uplift <br />governs <br />γE= <br />γa= <br /> KZt = <br />qh= 0.00256KzKztKdKeV2= <br />Pitch = <br />Lag Screw Penetration <br />projects@evengineersnet.com <br />http://www.evengineersnet.com <br />118 W Stevens Ave - <br />2018088010/12/2023