My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
CANCELLED-1915 W Trask Ave - Plan
PBA
>
Building
>
ProjectDox
>
T
>
Trask Ave
>
1915 W Trask Ave
>
CANCELLED-1915 W Trask Ave - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/1/2025 12:11:23 PM
Creation date
6/1/2025 12:11:13 PM
Metadata
Fields
Template:
Plan
Permit Number
20179255
101114562
Full Address
1915 W Trask Ave
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Page <br />RE <br />V <br />I <br />S <br />I <br />O <br />N <br />S <br />: <br />Pr <br />o <br />j <br />e <br />c <br />t <br /> <br />N <br />a <br />m <br />e <br /> <br />6. <br />4 <br />0 <br />0 <br /> <br />k <br />W <br /> <br />( <br />D <br />C <br />) <br /> <br />/ <br /> <br />5 <br />. <br />7 <br />8 <br />3 <br /> <br />k <br />W <br /> <br />( <br />C <br />E <br />C <br />- <br />A <br />C <br />) <br /> <br />PH <br />O <br />T <br />O <br />V <br />O <br />L <br />T <br />A <br />I <br />C <br /> <br />S <br />Y <br />S <br />T <br />E <br />M <br /> <br />1 <br />9 <br />1 <br />5 <br /> <br />T <br />R <br />A <br />S <br />K <br /> <br />A <br />V <br />E <br />1 <br />9 <br />1 <br />5 <br /> <br />T <br />R <br />A <br />S <br />K <br /> <br />A <br />V <br />E <br />, <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />6 <br />AP <br />N <br />: <br /> <br />1 <br />0 <br />1 <br />0 <br />4 <br />2 <br />2 <br />9 <br />DA <br />T <br />E <br />: <br /> <br />02 <br />/ <br />2 <br />2 <br />/ <br />2 <br />0 <br />2 <br />3 <br />DR <br />A <br />W <br />N <br /> <br />B <br />Y <br />: <br /> <br />ZM <br /> <br />Co <br />n <br />t <br />r <br />a <br />c <br />t <br />o <br />r <br />s <br /> <br />S <br />i <br />g <br />n <br />a <br />t <br />u <br />r <br />e <br />: <br /> <br />PR <br />E <br />M <br />I <br />E <br />R <br /> <br />B <br />U <br />I <br />L <br />D <br />E <br />R <br />S <br /> <br />& <br /> <br />H <br />A <br />R <br />D <br />S <br />C <br />A <br />P <br />E <br /> <br />I <br />N <br />C <br /> <br />88 <br />3 <br />2 <br /> <br />L <br />A <br /> <br />G <br />R <br />A <br />N <br />D <br /> <br />A <br />V <br />E <br /> <br />GA <br />R <br />D <br />E <br />N <br /> <br />G <br />R <br />O <br />V <br />E <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />8 <br />4 <br />1 <br /> <br />PH <br />O <br />N <br />E <br />: <br /> <br />( <br />7 <br />1 <br />4 <br />) <br /> <br />4 <br />6 <br />7 <br />- <br />9 <br />0 <br />1 <br />8 <br />LI <br />C <br />E <br />N <br />S <br />E <br />: <br /> <br /># <br />9 <br />9 <br />5 <br />0 <br />6 <br />8 <br />/ <br />B <br />, <br />C <br />5 <br />3 <br /> <br />PL <br />O <br />T <br /> <br />P <br />L <br />A <br />N <br /> <br />BUILDING SPECIFICATIONS <br />TYPE:S.F.D <br />STORIES:1 <br />BUILDING HEIGHT(FT.): 12 <br />BUILDING(SQ.FT):3103 <br />ROOF SLOPES(°):22 <br />ROOF FRAME MEMBER: 2X12 RAFTER <br />O.C. SPACING(IN.):16 <br />MAX SPAN:9'-0" IN BETWEEN SUPPORTS <br />MIN LAG BOLT <br />EMBEDMENT(IN.):2-1/2 <br />MOUNTING AND STANDOFF <br />SPECIFICATIONS <br />ROOFING MATERIAL:SINGLE LAYER COMP <br />RACKING SYSTEM:IRONRIDGE <br />STANDOFF DISTANCE(IN.): 64 <br />MOUNTING TYPE: FLUSH MOUNT <br />TILT LEG HEIGHT (IN.): N/A <br />HEIGHT OF PV MODULE <br />ABOVE ROOF SURFACE:3" TO 5" <br />MAX CANTILEVER (IN.): 24 <br />SYSTEM SPECIFICATIONS <br />SIZE(kW):6.400 <br />MODULE:(16) URE SOLAR FBM400MFG-BB <br />INVERTER(S):(16) ENPHASE IQ7PLUS-72-2-US <br />INVERTER TYPE:MICRO-INVERTER <br />STRING SCHEDULE:2 CIRCUIT(S) OF 8 MODULES <br />SYSTEM WEIGHT(LBS): 845.44 <br />ARRAY AREA(SQ.FT):336.21 <br />ARRAY AZIMUTH(°):180 <br />LBS/SQ.FT:2.51 <br />03 OF 11 <br />ROOF MOUNTED NOTES: <br />ADDITIONAL BUILDING DATA <br />TOTAL ARRAY AREA (SQ. FT.):336.21 <br />TOTAL PLAN VIEW ROOF AREA (SQ. FT.):3103 <br />OCCUPYING PV PERCENTAGE:10.84% <br />SPRINKLER SYSTEM INSTALLED (IFC 903.3.1.3)NO <br />- SOLAR PHOTOVOLTAIC SYSTEM TO BE INSTALLED <br /> ON RESIDENTIAL STRUCTURE (GROUP R3 BUILDINGS). <br />-THIS SYSTEM WILL NOT BE INTERCONNECTED UNTIL APPROVAL FROM <br /> THE LOCAL JURISDICTION AND THE UTILITY IS OBTAINED. <br />-A 36-INCH WIDE PATHWAY SHALL BE PROVIDED TO THE EMERGENCY <br />ESCAPE AND RESCUE OPENING(S). <br />-IF THE EXISTING MAIN SERVICE PANEL DOES NOT HAVE A VERIFIABLE <br /> GROUNDING ELECTRODE, IT IS THE CONTRACTOR'S RESPONSIBILITY <br /> TO INSTALL A SUPPLEMENTAL GROUNDING ELECTRODE. <br />R324.6.1 Pathways <br />R324.6.2 Setback at ridge <br />R324.6.2.1 Alternative setback at ridge <br />Exceptions: <br />1. These requirements shall not apply to structures designed and <br />constructed in accordance with the International Residential Code. <br />2. These requirements shall not apply to roofs with slopes of 2 <br />units vertical in 12 units horizontal or less. <br />ROOF ACCESS POINTS PER <br />2022 CRC, R324 (IFC 1204) <br />MSP PVLC <br />JB <br />A/C <br />D. <br />N <br />S <br />EW <br />Scale: 3/16" = 1'-0" <br />(For 24x36 Print) <br />COUNTY ELECTRONIC STAMP <br />(E) 225A MAIN SERVICE PANEL <br />120/240VAC SINGLE PHASE <br />NEMA 3R JUNCTION BOX <br />3FT WIDTH FIRE PATHWAY <br />3' <br />5'-4" 1'-4" <br />(N) SUPPORT RAILS (TYP.) <br />(E) ROOF FRAMING CENTERLINE <br />(N) TYP. ATTACHMENT POINT <br />(28) IN TOTALROOF ACCESS POINT <br />(STREET-SIDE) <br />(N) ENPHASE AC COMBINER BOX 240VAC, NEMA 3R <br />CONDUIT RUN IN-ATTIC <br />(N) 30A AC DISCONNECT 2P - NON FUSIBLE <br />1915 W Trask Ave <br />08/14/23
The URL can be used to link to this page
Your browser does not support the video tag.