Laserfiche WebLink
ASCE 29.4.4 Rooftop Solar Panels Parallel to the Roof Surface on Buildings of All Heights and Roof Slopes. <br />Roof Slope = 22 ° <br />Roof Shape Gable <br />Tributary Width s = 5.34 ft <br />Tributary Length l = 2.83 ft <br />Effective Area A e = 15.09 ft2 <br />Height of Structure h = 15 ft <br />Wind Speed V = 95 mph <br />Exposure Category C <br />Building Width B = 35 ft <br />Building Length L = 60 ft <br />Zone Width a = 3.5 ft <br />Elevation Height zg = 106 ft <br />Wind Directionality Kd = 0.85 <br />Topography Factor K t = 1.00 <br />Ground Elevation Factor Ke = 1.00 <br />Velocity Pressure Exposure Coefficient Kz = 0.85 <br />Velocity Pressure q z = 0.00256KzKztKdKeV 2 = 16.61 psf <br />Solar Array Pressure Equalization a = 0.78 <br />Array Edge Factor E = 1.50 <br />Zone GCp p = qz(GCp)( E)( a) <br />3 - - <br />3r 3.17 -61.31 <br />3e 2.45 -47.50 <br />2 - - <br />2r 2.45 -47.50 <br />2e - - <br />2n 2.45 -47.50 <br />1 -- <br />1'-- <br />1915 W Trask Ave <br />08/14/23