My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
HOLD - 122 N Bewley St - Plan
PBA
>
Building
>
ProjectDox
>
B
>
Bewley St
>
122 N Bewley St
>
HOLD - 122 N Bewley St - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/13/2025 12:19:09 PM
Creation date
6/1/2025 12:11:13 PM
Metadata
Fields
Template:
Plan
Permit Number
101118359
Full Address
122 N Bewley St
Street Number
122
Street Direction
N
Street Name
Bewley
Street Suffix
St
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
46
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
EngDrwg: 2021r5RGT_PS <br />08401 - 08401 Qty: 1 Truss: A1 <br />Customer: Walk-in <br />Truss Mfr. Contact: Charlie Shepard <br />SID:0002410426 <br />TID:203630 <br />Date:09 / 07 / 23 <br />Page:1 of 1 <br />NOTICE A copy of this design shall be furnished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by <br />the Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. A seal on this drawing indicates <br />acceptance of professional engineering responsibility solely for the truss component design shown. See the cover page and the “Important Information & General <br />Notes” page for additional information. All connector plates shall be manufactured by Simpson Strong-Tie Company, Inc in accordance with ESR-2762. All connector <br />plates are 20 gauge, unless the specified plate size is followed by a “-18” which indicates an 18 gauge plate, or “S# 18”, which indicates a high tension 18 gauge plate. <br />Component Solutions <br />Truss Studio V <br />2023.7.0.65 <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br />Typical plate: 1.5x3 <br />3x4 = <br />4x6 <br />4x6 <br />3x5 <br />3x5 3x4 =5x6 = <br />10 <br />- <br />1 <br />4 <br />10 <br />- <br />1 <br />4 <br />3-15 3-15 <br />4- <br />1 <br />0 <br />- <br />1 <br />2 <br />5- <br />2 <br />- <br />2 <br />1 <br />4-8-12 <br />4-8-12 <br />2 <br />2-6-6 <br />7-3-2 <br />3 <br />6-5-6 <br />13-8-8 <br />4 <br />6-5-6 <br />20-1-14 <br />5 <br />7-3-2 <br />27-5-0 <br />6 <br />1 <br />4-8-12 <br />4-8-12 <br />7 <br />4-3-4 <br />9-0-0 <br />8 <br />9-4-15 <br />18-5-0 <br />9 <br />9-0-0 <br />27-5-0 <br />6 <br />27-5-0 <br />4-7-04-7-0 <br /> 4/12 -4/12 <br />Truss Weight = 175.2 lb <br />Code/Design: CBC-2022/TPI-2014 <br />PSF Live Dead Dur Factors <br />TC 20.0 16.0 Live Wind Snow <br />BC 0.0 10.0 Lum 1.25 1.60 N/A <br />Total 46.0 Plt 1.25 1.60 N/A <br />Spacing: 2-00-00 o.c. Plies: 1 <br />Repetitive Member Increase: Yes <br />Green Lumber: No Wet Service: No <br />Fab Tolerance: 20% Creep (Kcr) = 2.0 <br />OH Soffit Load: 2.0 psf <br />-----------Snow Load Specs---------- <br />ASCE7-16 Ground Snow(Pg) = N/A <br />Risk Cat: II Terrain Cat: C <br />Roof Exposure: Sheltered <br />Thermal Condition: All Others(1.0) <br />Unobstructed Slippery Roof: No <br />Low-Slope Minimums(Pfmin): No <br />Unbalanced Snow Loads: No <br />Rain Surcharge: No Ice Dam Chk: No <br />----------Wind Load Specs---------- <br />ASCE7-16 Wind Speed(V) = 120 mph <br />Risk Cat: II Exposure Cat: C <br />Bldg Dims: L = 0.0 ft B = 0.0 ft <br />M.R.H(h) = 15.0 ft Kzt = 1.0 <br />Bldg Enclosure: Enclosed <br />Wind DL(psf): TC = 9.6 BC = 6.0 <br />End Vertical Exposed: L = Yes R = Yes <br />Wind Uplift Reporting: ASCE7 MWFRS <br />C&C End Zone: 3-00-00 <br />-------Additional Design Checks------ <br />10 psf Non-Concurrent BCLL: Yes <br />20 psf BC Limited Storage: Yes <br />200 lb BC Accessible Ceiling: Yes <br />300 lb TC Maintenance Load: Yes <br />2000 lb TC Safe Load: No <br />Unbalanced TCLL: Yes <br />Material Summary <br />TC 2x4 DFL #1B <br />BC 2x4 DFL #1B <br />Webs 2x4 DFL #2 <br /> <br />Member Forces Summary <br />Max CSI in TC PANEL 5 - 6 0.59 <br />Max CSI in BC PANEL 9 - 6 0.60 <br />Max CSI in Web 7 - 3 0.37 <br /> <br />...Mem... Ten Comp .CSI. <br />TC OH- 1 47 0 0.10 <br /> 1- 2 1140 203 0.31 <br /> 2- 3 1124 167 0.48 <br /> 3- 4 217 1113 0.49 <br /> 4- 5 280 1942 0.49 <br /> 5- 6 291 2253 0.59 <br /> 6-OH 47 0 0.10 <br />BC 1- 7 216 1051 0.19 <br /> 6- 9 2078 193 0.60 <br /> 7- 8 775 97 0.46 <br /> 8- 9 1115 93 0.53 <br />Web 2- 7 60 324 0.03 <br /> 3- 7 237 1832 0.37 <br /> 3- 8 455 0 0.08 <br /> 4- 8 137 330 0.22 <br /> 4- 9 904 43 0.16 <br /> 5- 9 181 520 0.08 <br /> Reaction Summary <br /> --------------Reaction Summary(Lbs)---------------- <br /> Jnt --X-Loc- React -Up- --Width- -Reqd -Mat PSI <br /> 7 4-08-12 1609 4 03-08 02-00 SPF 531 <br /> 6 27-03-04 1065 3 03-08 01-08 SPF 531 <br /> Max Horiz = -56 / +56 at Joint 7 <br />Loads Summary <br />This truss has been designed for the effects of an unbalanced top chord <br />live load occurring at [13-08-08] using a 1.00 Full and 0.00 Reduced load <br />factor. <br />20.0 psf Live load has been reduced for pitch(R2= 1.00) to (20.0 psf) <br />(allowed by the selected code) <br />See Loadcase Report for loading combinations and additional details. <br />Notes <br />Gable webs are attached with min. 1x3 20 ga.plates. The max.rake overhang <br />= 1/2 the truss spacing. If this truss is exposed to wind loads <br />perpendicular to the plane of the truss, it must be braced according to a <br />standard detail matching the wind criteria shown, or according to the <br />Construction Documents and/or BCSI - B3. <br />Plates designed for Cq at 0.80 and Rotational Tolerance of 10.0 degrees. <br />Plates located at TC pitch breaks meet the prescriptive minimum size <br />requirement to transfer unblocked diaphragm loads across those joints. <br />This truss is not symmetric - proper orientation is critical. <br />Deflection Summary <br />TrussSpan Limit Actual(in) Location <br />Vert LL L/240 L/999(-0.14) 8- 9 <br />Vert DL L/120 L/999(-0.18) 8- 9 <br />Vert CR L/180 L/869(-0.31) 8- 9 <br />Horz LL 0.75in ( 0.02) @Jt 6 <br />Horz CR 1.25in ( 0.05) @Jt 6 <br />Ohng CR 2L/180 2L/999(-0.00) 1- 1 <br />Ohng CR 2L/180 2L/999(-0.00) 6- 6 <br />Cant CR 2L/180 2L/999(-0.04) 1- 7 <br />Bracing Data Summary <br />------------Bracing Data------------ <br />Chords; continuous except where shown <br />Web Bracing -- None <br /> <br />Plate offsets (X, Y): <br />(None unless indicated below) <br />Jnt9(0,-01-00) <br />HOLD - 122 N <br />Bewley St9/24/2024
The URL can be used to link to this page
Your browser does not support the video tag.