Laserfiche WebLink
ALLOWABLE SPANS AND LOADS FOR WOOD STRUCTURAL PANEL SHEATING AND SINGLE-FLOOR GRADES CONTINOUS OVER TWO <br />OR MORE SPANS WITH STRENGH AXIS PERPENDICULAR TO SUPPORTS NOTE: APPLIES TO PANEL 24" OR WIDER <br />SHEATING GRADES ROOF FLOOR <br />PANEL SPAN RATING <br />ROOF/FLOOR SPAN <br />MINIMUM <br />PANEL THICKNESS <br />(INCHES) <br />MAXIMUM SPAN (INCHES)LOADS (PSF) <br />EDGE SUPPORT NO EDGE <br />SUPPORT <br />TOTAL LOAD LIVE LOAD <br />MAX. SPAN (INCHES) <br />PANEL EDGES WITH <br />TONGUE AND GROOVE <br />JOINTS OR WITH <br />BLOCKING <br />24/0 <br />24/16 <br />32/16 <br />40/20 <br />48/24 <br />3/8 <br />7/16 <br />23/32 , 3/4 <br />19/32 , 5/8 <br />15/32 , 1/2 <br />24 20 <br />24 <br />32 <br />40 <br />48 <br />24 <br />28 <br />32 <br />36 <br />40 <br />50 <br />40 <br />40 <br />45 35 <br />30 <br />40 <br />30 <br />30 <br />16 <br />16 <br />20 <br />24 <br />CONNECTION <br />BLOCKING BETWEEN JOISTS OR RAFTERS TO TOP PLATE <br />CEILING JOISTS TO PLATE <br />CEILING JOISTS NOT ATTACHED TO PARALLEL RAFTER, LAPS <br />OVER PARTITIONS <br />COLLAR TIE RAFTER, FACE NAIL OR 20-GAGE RIDGE STRAP <br />RAFTER TO PLATE <br />ROOF RAFTERS TO RIDGE, VALLEY OR HIP RAFTERS: <br />TOE NAIL <br />FACE NAIL <br />BUILT-UP CORNER STUDS <br />BUILT-UP HEADER TWO PIECES WITH 12" SPACER <br />CONTINUED HEADER TWO PIECES <br />CONTINUED HEADER TO STUD <br />DOUBLE STUDS <br />DOUBLE TOP PLATES <br />DOUBLE TOP PLATES, MINIMUM 24-INCH OFFSET OF END JOINTS <br />FACE NAIL IN LAPPED AREA <br />SOLE PLATES TO JOIST OR BLOCKING <br />SOLE PLATES TO JOIST OR BLOCKING AT BRACED WALL PANELS <br />STUD TO SOLE PLATE <br />TOP OR SOLE PLATE TO STUD <br />TOP PLATES, LAP AT CORNERS AND INTERSECTIONS <br />JOIST TO SILL OR GIRDER <br />RIM JOIST TO TOP PLATE (ROOF APPLICATION ALSO) <br />BUILT-UP GIRDERS AND BEAMS, 2-INCH LUMBER LAYERS <br />LEDGER STRIP SUPPORTING JOISTS OR RAFTERS <br />FASTENING REMARKS <br />ROOF <br />3-8d (2-1/2" x 0.113") <br />3-8d (2-1/2" x 0.113") <br />3-10d (3" x 0.128") <br />3-10d (3" x 0.128") <br />3-8d COMMON <br />3-16d (3-1/2" x 0.135") <br />4-16d (3-1/1" x 0.135") <br />10d (3" x 0.128") <br />16d (3-1/1" x 0.135") <br />4-8d (2-1/2" x 0.113") <br />10d (3" x 0.128") <br />16d (3-1/1" x 0.135") <br />10d (3" x 0.128") <br />8-16d (3-1/1" x 0.135") <br />WALL <br />16d (3-1/1" x 0.135") <br />16d (3-1/1" x 0.135") <br />3-8d (2-1/2" x 0.113") <br /> OR <br />2-16d (3-1/2" x 0.135") <br />2-16d (3-1/2" x 0.135") <br />2-10d (3" x 0.128") <br />FLOOR <br />3-8d (2-1/2" x 0.113") <br />8d (2-1/2" x 0.113") <br />10d (3" x 0.128") <br />2-16d (3-1/2" x 0.135") <br />TOE NAIL <br />TOE NAIL <br />TOE NAIL <br />TOE NAIL <br />24" O.C. <br />16" O.C. ALONG EACH EDGE <br />16" O.C. ALONG EACH EDGE <br />TOE NAIL <br />24" O.C. <br />24" O.C. FACE NAIL <br />FACE NAIL <br />16" O.C. FACE NAIL <br />16" O.C. <br />TOE NAIL <br />END NAIL <br />FACE NAIL <br />TOE NAIL <br />6" O.C. <br />NAIL EACH LAYER AS FOLLOWS: 32" O.C. AT <br />TOP AND BOTTOMS AND STAGGERED. TWO <br />NAILS AT ENDS AND EACH SPLICE. <br />AT EACH JOIST OR REFTER <br />1 NAILING SCHEDULE <br />7 MATERIAL REQUIREMENTS <br />CONCRETE BLOCK UNITS SHALL NOT BE WETTED UNLESS <br />BOLTS SHALL HAVE STANDARD HEX HEADS. <br />MIN. CEMENT CONTENT <br />6.5 SACKS/C.Y. <br />6.5 SACKS/C.Y. <br />6.5 SACKS/C.Y. <br />LOCATION <br />SLAB ON GRADE <br />GRADE BEAM <br />FOOTINGS <br />CEMENT - ASTM C150, TYPE V <br />CONCRETE BLOCK: <br />REINFORCING STEEL: <br />CONCRETE: <br />ANCHOR BOLTS : <br />BOLTS : <br />EPOXY ADHESIVE : <br />AGGREGATE - ASTM C33, NORMAL WEIGHT, 1" MAX. SIZE AT SLAB ON GRADE <br />ASTM A 615 GRADE 40 FOR #3 AND #4; GRADE 60 <br />ASTM C90, GRADE N-1 MEDIUM WT. f'm=1500psi <br />ASTM A706 FOR GRADE BEAMS, CAISSONS & WELDED BARS. <br />ASTM A325 SC, A307 FOR ALL THREADED RODS <br />ASTM 307, A354 GRADE BC WHERE NOTED. ALL ANCHOR <br />FOR ALL OTHER SIZES <br />MORTAR: f'c=1800psi , TYPE S <br />GROUT: f'c=2000psi <br />28 DAY STRENGTH <br />3000 PSI <br />2500 PSI <br />2500 PSI <br />SIMPSON SET-XP ADHESIVE AS MANUFACTURED <br />BY SIMPSON STRONG TIE, LARR # 25744 <br />(ASSEMBLAGE STRENGTH) <br />SPECIFICALLY APPROVED. <br />MOISTURE CONTENT AT THE TIME OF PLACING SHALL BE 19% FOR BOTH <br />FOR ALL OTHER. UNLES OTHERWISE NOTED ON PLANS MAXIMUM <br /> No. 2 OR BETTER FOR BEAMS & POSTS, No. 2 OR BETTER <br />TREATED AND UNTREATED LUMBER. <br />DOUGLAS FIR LARCHSAWN TIMBER: <br />RATED SHEATHING, EXPOSURE 1 <br />U.S. PRODUCT STD. PS 1-95, STRUCTURAL IPLYWOOD: <br />SOIL: 1,500 psf <br /> GRADE AND SPECIES OF ALL LUMBER. "MUST BE GRADE MARKED". <br />SHOP WELDS MUST BE PERFORMED IN A LA CITY BLDG. DEPT. <br />STRUCTURAL STEEL ASTM (A36) (A992), STRUCTURAL PIPE ASTM A53 Gd B, <br />TUBING ASTM A501. REINFORCING BARS ASTM A615. <br />CONTINUOUS INSPECTION BY A DEPUTY INSPECTOR IS REQUIRED <br />FOR ALL CONCRETE DESIGN WITH f'c GREATER THAN 2500 psi <br /> PROVIDE LEAD HOLE 40%-70% OF THREADED SHANK DIA. AND FULL DIA. <br />FOR SMOOTH SHANK PORTION. <br />FOUNDATION SILL PLATES SHALL BE PRESSURE TREADED, OR FOUNDATION GRADE REDWOOD. <br />6.0 SACKS/C.Y.ALL OTHERS 2500 PSI <br />& CAISSONS <br />STEEL: <br />WOOD FRAMING MEMBERS: <br />LAG BOLTS: <br />LICENSED FABRICATOR'S SHOP. <br />SITE CLASS: " D " <br />FASTENERS FOR PRESERVATIVE TREATED AND FIRE TREATED WOOD SHALL BE OF HOT DIPPED ZINC <br />COATED GALVANIZED STEEL,SILICON BRONZE OR COPPER.THE COATING WEIGHTS FOR ZINC COATED <br />FASTENERS SHALL BE IN ACCORDANCE WITH ASTM A 153. CRC R317.3 <br />8 SEISMIC DESIGN VALUES <br />9 SHEET INDEX <br />SEQ.SHT. <br />1 <br />S-N STRUCTURAL NOTES & REQUIREMENTS <br />DESCRIPTION <br />2 S-2 STRUCTURAL DETAILS <br />SEISMIC IMPORTANCE FACTOR, I, AND OCCUPANCY CATEGORY: <br />MAPPED SPECTRAL RESPONSE ACCELERATIONS, Ss AND S : <br />SITE CLASS: <br />SPECTRAL RESPONSE COEFFICIENTS, S AND S : <br />SEISMIC DESIGN CATEGORY: <br />BASIC SEISMIC-FORCE-RESISTING SYSTEM: <br />DESIGN BASE SHEAR: <br />1 <br />DS D1 <br />SEISMIC RESPONSE COEFFICIENT, C :S <br />RESPONSE MODIFICATION FACTOR, R: <br />ANALYSIS PROCEDURE USED: <br />I = 1 AND OCCUPANCY = II <br />D <br />S = 1.318 AND S = 0.470s <br />S = 1.055 AND S = 0.470sD1D <br />1 <br />R = 6.5 <br />C = ( 1.055 x I ) / R )=0.1623077s <br />D <br />CONVENTIONAL FRAME CONSTRUCTION (WOOD BRACING) <br />V= 5,209 # <br />EQUIVALENT LATERAL FORCE PROCEDURE <br />REDUNDANCY FACTOR USED: <br />P=1.3 <br />HOUSE ADDITION EARTHQUAKE DESIGN DATA <br />LOADS <br />EXT. WALL LOADS ------------------------------------------------------- <br />PITCHED ROOF DEAD LOAD AND LIVE LOADS = <br /> = 16 psf <br />12 psf + 20 psf = 32 psf <br />Site Latitude: 33.7460164 Site Longitude: -117.9181950 <br />FLAT ROOF DEAD LOAD AND LIVE LOADS =15 psf + 20 psf = 35 psf <br />4 FOUNDATION PLAN NOTES3STRUCTURAL NOTES2SHEAR PANEL SCHEDULE <br /> DRAG STRUT <br /> HOLDOWN <br /> EDGE NAILS <br /> WALL SIDE CHORD (POST) <br /> FIELD NAILS <br /> FRAMING ANCHOR <br /> ANCHOR BOLT <br /> BLOCKING <br /> SILL PLATE <br /> SILL NAILS OR <br /> ALLOWED LOAD <br /> GRADE <br />KEY <br />SCREWS <br />1 5/8" <br />3/4" A.B. <br />SEE PLAN <br />SEE PLAN <br />@24" O.C. <br />STRUCT. I <br />870 <br />10d @2" O.C. <br />10d @12" O.C. <br />4X4 <br />3x4 <br />YES <br />D <br />1 <br />16/D <br />A35 OR LTP4 <br />@ 8" O.C. <br />3/8"Øx6" LAGSCREWS @8"O.C. <br />1 1/2"1 1/2"1 1/2" <br />5/8" A.B. <br />SEE PLAN <br />SEE PLAN <br />@32" O.C. <br />A35 OR LTP4 <br />STRUCT. I <br />340 <br />10d @6" O.C. <br />10d @12" O.C. <br />2X4 <br />4X4 <br />20d @ 6" O.C. <br />YES <br />3/4" A.B.5/8" A.B. <br />SEE PLAN <br />SEE PLAN <br />510 <br />STRUCT. I <br />@24" O.C. <br />A35 OR LTP4 <br />@24" O.C. <br />SEE PLAN <br />SEE PLAN <br />STRUCT. I <br />665 <br />4X4 <br />3x4 <br />YES <br />10d @4" O.C. <br />3/8"Øx6" LAG <br />10d @12" O.C. <br />10d @3" O.C. <br />10d @12" O.C. <br />4X4 <br />3X4 <br />YES <br />16/D <br />1 <br />A <br />15/32 STRUCT 1 <br />B <br />16/D <br />1 <br />C <br />1 <br />16/D <br />(PLYWOOD or OSB) <br />@ 24" O.C.@ 16" O.C. <br />A35 OR LTP4 <br />@ 12" O.C. <br />SCREWS @16"O.C.3/8"Øx6" LAGSCREWS @12"O.C. <br />E G <br />7/8 STUCCO <br />5/8" A.B. <br />@ 48" O.C. <br />180 <br />7/8 STUCCO <br />2X4 <br />4x4 <br />16d @6" O.C. <br /> ON WOVEN WIRE OR <br /> EXPANDED METAL <br /> LATH W/ NO. 11GA. NAILS, <br /> 1-1/2"x7/16" HEADS <br /> W/ 1/4" FURRING; <br /> APPLY NAILING AT ALL <br />STUDS, TOP & BOTTOM <br />PLATES, & BLOCKING. <br />A35 OR LTP4 <br />@ 32" O.C. <br />SEE PLAN <br />SEE PLAN <br />1 5/8" <br />10d @3" E.F. <br />10d @12" O.C. <br />3/4" A.B. <br />SEE PLAN <br />SEE PLAN <br />@ 16" O.C. <br />STRUCT. I <br />1,300 <br />4X6 <br />3x4 <br />YES <br />F <br />1 <br />16/D <br />A35 OR LTP4 <br />@ 12" O.C., E.F. <br />3/8"Øx6" LAGSCREWS @6"O.C. <br />A.-ALL EXTERIOR WALL TO BE SECURED WITH 5 8" DIAM. x 16" A.b.'S AT 48" O.C. WITH 9" OF EMBEDMENT, UNLESS OTHERWISE NOTED, AND WITH <br />MINIMUM 3"x3"x14" THICK PLATE WASHER UNDER NUT AT EACH BOLT. <br />B.-ALL INTERIOR WALLS WITH SHOT PINS; RAMSET # 3348, OR EQUIVALENT, AT 36" O.C. AT BEARING WALLS AND 48" O.C. AT NON BEARING WALLS, <br />UNLESS OTHERWISE NOTED. <br />C.-CODE MINIMUM (2) ANCHOR BOLTS PER PANEL. <br />D.-CODE MINIMUM 16d SOLE PLATE NAILS AT 16" O.C. TYPICAL AT ALL SECOND FLOOR WALLS (U.O.N.). <br />E.-WHERE DOUBLE 2x SOLE PLATES ARE USED, PROVIDE PROGRESSIVE NAILING. <br />F.-ALL NAILS ARE COMMON NAILS. <br />G.-TABLE FOR USE WITH STUDS AT 16" O.C. MAXIMUM. <br />H.-ALL LAG BOLTS (LB) TO BE 8" LONG INSTALLED WITH PILOT HOLE AND WRENCH. <br />J.-5 8" DIAM. A.B. MAY BE REPLACED BY 5 8" DIAM. THREADED RODS BY 5" EMBED. WITH SIMPSON AT EPOXY SET-XP, (OR EQUIVALENT) AT THE SAME <br />SPACING, WITH SPECIAL INSPECTION. EACH BOLT SHALL HAVE MIN, 3"x3"x14" THICK SQUARE WASHER. <br />K.-FRAMING MEMBERS OR BLOCKING SHALL BE PROVIDED AT ALL EDGES OF ALL PLYWOOD SHEETS IN SHEAR WALL. <br />L.-ALL PLYWOOD PANEL SHALL BE MANUFACTURED USING EXTERIOR GLUE. <br />1.-USE 3x STUDS, 3x BOTTOM PLATE, 3x BLK'G WITH STAGGERED NAILING WHERE THE ALLOWABLE SHEAR VALUE EXCEEDS 350 PLF. <br />2.-WHERE SHEAR MATERIAL IS INSTALLED ON BOTH SIDES THE SPACING FOR THE ABOVE TOP ANCHORAGE AND SILL CONNECTION SHALL BE HALF <br />SHOWN. UNLESS OTHERWISE NOTED ON PLANS. <br />MATERIAL <br />PANEL INDEX <br />SIDE <br />MIN. NAIL PENETRATION <br />15/32 STRUCT 1 (PLYWOOD or OSB)15/32 STRUCT 1 (PLYWOOD or OSB)15/32 STRUCT 1 (PLYWOOD or OSB)EXISTING 15/32 STRUCT 1 (PLYWOOD or OSB) <br />1.-STUCCO SHEAR WALLS USE SELF- FURRING 11 GA. 1-12" GALVANIZED NAILS WITH 7 16" DIAMETER <br />HEAD. STAPLES SHALL NOT BE USED. <br />2.-STEEL PLATE WASHERS SHALL BE USED WITH ALL ANCHORS BOLTS AS FOLLOWS <br />5 8" BOLT = 3"X3"X0.229" <br />3 4" BOLT = 3"X3"X5 16" <br />7 8" BOLT = 3"X3"X3 8" <br />3.-PROVIDE 4x POST AT ALL HOLLDOWNS UNLESS NOTED OTHERWISE. <br />4.-VERTICALLY CENTER HOLDOWN STRAPS ON DEAD SPACE BETWEEN SILL AND TOP PLATE OF WALL <br />BELOW. <br />5.-FILL ALL NAIL HOLES OF HOLDOWN STRAPS. <br />6.-WHERE HOLDOWN ANCHOR EDGE DISTANCE IS LESS THAN 6 TIMES Ø, DEPUTY INSPECTION IS <br />REQUIRED. <br />7.-FOR SIMPSON HOLDOWNS IN NEW CONCRETE. f'c = 2500 PSI. <br /> THE FOLLOWING EMBEDMENT DEPT IS REQUIRED. <br />5 8" BOLT = 12" MIN. , 3 4" BOLT = 16" MIN., 7 8" BOLT = 24" MIN. <br />8.-"LAG BOLTS: PROVIDE LEAD HOLE 40%-70% OF THREADED SHANK DIA. AND FULL DIA. FOR SMOOTH <br />SHANK PORTION." 2005 NDS. <br />9.-"ALL BOLT HOLES SHALL BE DRILLED 132" TO 116" OVERSIZED." <br />10.-ALL DIAPHRAGMS AND SHEAR WALL NAILING SHALL UTILIZE COMMON NAILS OR GALVANIZAED <br />BOX. <br />11.-CONTRACTOR RESPONSIBLE FOR THE CONSTRUCTION OF A WIND OR SEISMIC FORCE RESISTING <br />SYSTEM/COMPONENT LISTED IN THE "STATEMENT OF SPECIAL INSPECTION" SHALL SUBMIT A <br />WRITTEN STATEMENT RESPONSABILITY TO THE LADBS INSPECTORS AND THE OWNER PRIOR TO <br />THE COMMENCEMENT OF WORK ON SUCH SYSTEM OR COMPONENT PER SEC 1706.1 <br />12.-PERIODIC SPECIAL INSPECTION IS REQUIRED FOR WOOD SHEAR WALLS, SHEAR PANELS, AND <br />DIAPHRAGMS, INCLUDING NAILING, BOLTING, ANCHORING, AND OR FASTENING TO COMPONENTS <br />OF THE SEISMIC FORCE RESISTING SYSTEM. SPECIAL INSPECTOR BY A DEPUTY INSPECTOR IS <br />REQUIRED WHERE THE FASTENER SPACING OF THE SHEATING IS MORE THAN 4 INCHES ON CENTER. <br />13.-ROOF DIAPRAGM NAILING TO BE INSPECTED BEFORE COVERING. <br /> FACE GRAIN OF PLYWOOD SHALL BE PERPENDICULAR TO <br /> SUPPORTS. FLOOR SHALL HAVE TONGUE AND GROOVE OR <br /> BLOCKED PANEL EDGES. PLYWOOD SPANS SHALL CONFORM <br /> WITH TABLE 2304.7. <br />14.-CONTINUOUS INSPECTION BY A REGISTERED DEPUTY INSPECTOR IS REQUIRED FOR FIELD <br />WELDING, CONRETE STRENGTH f'c > 2,500 psi, HIGH STRENGTH BOLTING, SPRAYED-ON <br />FIREPROOFING, ENGINEER MASONRY, HIGH LIFT GROUTING, PRE-STRESSED CONCRETE, HIGH LOAD <br />DIAPHRAGMS AND SPECIAL MOMENT-RESISTING CONCRETE FRAME. <br />15.-NOTCHING OF RAFTER OR JOIST COMPLY WITH THE FOLLOWING: <br />A.MAXIMUM DEPTH OF NOTCHING AT ENDS OF THE MEMBER SHALL NOT EXCEED ONE-FOURTH <br />THE DEPTH OF THE MENMBER. <br />B.NOTCHES IN THE TOP OR BOTTOM OF THE MEMBER SHALL NOT EXCEED ONE-SIX OF THE <br />DEPTH, AND SHALL NOT BE LOCATED IN THE MIDDLE THIRD OF THE SPAN. <br />3 <br />S-1 FRAMING & FOUNDATION PLAN <br />1.HOLD-DOWN HARWARE MUST BE SECURE IN PLACE PRIOR TO FOUNDATION INSPECTION <br />AND POURING OF CONCRETE. <br />2.BOLTS HOLES SHALL BE 1/16 " (MAX.) OVERSIZED AT THE CONECTOR OF THE <br />HOLD-DOWN TO POST. INSPECTOR SHALL VERIFY. <br />3.HOLD-DOWN CONNECTOR SHALL BE TORQUED AS SPECIFIED BY MANUFACTURER. <br />5.OVERSIZED PLATE WASHERS FOR HOLD-DOWNS AND SILL PLATES: A.B. - 5/8"Øx12" <br />WASHER - 3"x3"x0.229" <br />6.NO TRENCHES OR EXCAVATIONS 5'-0" OR MORE IN DEPTH INTO WHICH A PERSON IS <br />REQUIRED TO DESCEND. <br />7.STIPULATES A MINIMUN OF TWO ANCHOR BOLTS WILL BE PROVIDED FOR EACH PLATE <br />LENGTH WITH ONE BOLT LOCATED NOT MORE THAN 12" OR LESS THAN 7" FROM EACH <br />END OF THE PIECE. <br />8.FOUNDATION SILLS SHALL BE NATURAL DURABLE, OR PRESERVATIVE-TREATED WOOD. <br />9.HOLDOWN CONNECTOR BOLTS INTO WOOD FRAMING REQUIRE APPROVED PLATE <br />WASHERS: AND HOLDOWNS SHALL BE FINGER TIGHT AND 1/2 WRENCH TURN JUST PRIOR <br />TO COVERING THE WALL FRAMING. CONNECTOR BOLTS INTO WOOD FRAMING REQUIRED <br />STEEL PLATE WASHERS ON THE POST ON THE OPPOSITE SIDE OF THE ANCHORAGE <br />DEVICE. PLATE SIZE SHALL BE A MINIMUM OF 0.299 INCH BY 3 INCH BY 3 INCHES. <br />10.IF ADVERSE SOIL CONDITIONS ARE ENCOUNTERED, A SOILS INVESTIGATION REPORT MAY <br />BE REQUIRED. <br />11.INSULATION ON FLOORS SHALL BE SUPPORTED BY CORROSION- RESISTANT WIRE <br />PERPENDICULAR TO JOIST, NOT EXCEEDING 12 in. ON CENTER. <br />12.INSULATION TO BE HELD BACK ONE BAY WIDTH TO PROVIDE FREE AIRFLOW. <br />ROOF PLYWOOD DIAPHRAGM (SHEATING): <br />USE 12" STRUCTURAL C-D OR C-C PLYWOOD, MIN. PANEL INDEX NUMBER (24/16), WITH 8d NAILS AT 6" O.C. SUPPORTED EDGES AND BOUNDARIES; <br />AT 12" O.C. IN THE FIELD UNBLOCKED U.O.N.). FACE GRAIN OF PLYWOOD SHALL BE PERPENDICULAR TO SUPPORTS. <br />FLOOR OR DECK PLYWOOD DIAPHRAGM (SHEATING): <br />USE 5 8" STRUCTURAL C-D OR C-C PLYWOOD, MIN. PANEL INDEX NUMBER (32/16), TONGUE & GROOVE, WITH 10d NAILS AT 6" O.C. SUPPORTED EDGES <br />AND BOUNDARIES; AT 10" O.C. IN THE FIELD (UNBLOCKED U.O.N.) FACE GRAIN OF PLYWOOD SHALL BE PERPENDICULAR TO SUPPORTS. <br />NOTES: <br />1.-PROVIDE 2-LAYER OF GRADE D PAPER AT ALL SHEAR WALLS. <br />2.-ALL DIAPHRAGM AND SHEAR WALL NAILING SHALL UTILIZE COMMON NAILS. <br />3.-USE DOUBLE FLOOR JOIST BELOW ALL PARALLEL WALLS U.N.O. <br />4.-AT FLOOR LEVELS, USE SOLID BLOCKING AT PERPENDICULAR SHEARWALLS. <br />5.-ALL HOLDOWNS ON UPPER LEVEL MUST BE CONNECTED TO A POST BELOW WITH A HOLDOWN TO THE LOWER LEVEL / FOUNDATION. <br />6.-ALL BEAMS SUPPORTING SHEARWALLS MUST BE STRAPPED TO THE WALLS BELOW. <br />TYPICAL CALIFORNIA FRAMING <br />LOWER RAFTER <br />PLAN CONT. AT <br />ROOF SHT`G. PER <br />SDS 1 <br />4"x41 <br />2" SCREWS <br />@ 12" O.C. <br />2x PLATE <br />W/A35 EA. <br />END <br />3x BLKG <br />EDGE NAIL <br />A35 <br />FRAMING <br />CALIFORNIA <br />2x RAFTER <br />2x RAFTER <br />OR HIP <br />(N) SIMPSON MST37 DRAG <br />6 SPECIAL DEPUTY INSPECTION PROGRAM <br />CONTINUOUS SPECIAL DEPUTY INSPECTION <br />- EPOXY: DOWELS, ANCHOR BOLT & SHEAR BOLTS <br />PERIODIC SPECIAL DEPUTY INSPECTION <br />- NAILING, BOLTING, ANCHORING AND OTHER FASTENING OF <br />COMPONENTS WITHIN THE SEISMIC-FORCE-RESISTING SYSTEM, <br />INCLUDING SHEAR WALLS, WOOD DIAPHRAGMS, DRAG STRUTS, <br />BRACES, SHEAR PANELS AND HOLD-DOWNS REQUIRE INSPECTION <br />WHERE THE FASTENER SPACING OF THE SHEATHING IS 4" ON CENTER <br />( O.C.) OR LESS. <br />5 LARR #'S <br />SSTB ANCHOR BOLT BY SIMPSON <br />HDU HOLDOWN <br />MST STRAP <br />JOIST HANGER <br />FRAMING ANGLES <br />LARR #25827 <br />LARR #25720 <br />LARR # 25713 <br />LARR # 25807 <br />LARR # 25716 <br />COLUMN CAP LARR # 25714 <br />SIMPSON EPOXY SET-XP LARR # 25744 <br />PARALLAM BEAMS (PSL) BY TRUS JOIST LARR # 25202 <br />LAMARITE SHAKE AS A CLASS A ROOFING BY LARR # 25613 <br />(TAMKO BUILDING PRODUCTS, INC.) <br />18NONE 19NONE 20NONE <br />21NONE 22NONE 23NONE <br />TYP. FLOOR JOIST & BEAM NOTCH DETAIL <br />1/3 OF JOIST 1/3 OF JOIST 1/3 OF JOIST <br />TOTAL SPAN <br />NOT NOTCHING <br />ALLOWED AT THIS <br />AREA <br />NOT NOTCHING <br />ALLOWED AT THIS <br />AREA <br />1/ <br />3 <br />DE <br />P <br />T <br />H <br />1/ <br />3 <br />DE <br />P <br />T <br />H <br />ALLOWED HOLE ZONE <br />NOTES: <br />1. ALLOWED HOLE ZONE SUITABLE FOR UNIFORMLY LOADED BEAMS ONLY. <br />2. NO RECTANGULAR HOLES. <br />3. NO HOLES IN CANTILEVER ALLOWED. <br />2 x DIAMETER OF THE <br />LARGEST HOLE (MINIMUM) <br />BEAM DEPTH MAXIMUM ROUND HOLE SIZE <br />9-1/4" TO 18"2" <br />TYP. NOTCHING & BORING OF STUDS DETAIL <br />2" MAXIMUM DIAMETER @ <br />7/8" MAXIMUM @ 2X4 STUDS <br />1 3/8" MAXIMUM @ 2X6 STUDS <br />40% MAXIMUM NOTCH <br />25% MAXIMUM NOTCH <br />1 3/8" MAXIMUM @ 2X4 STUDS <br />2 1/8" MAXIMUM @ 2X6 STUDS <br />2X6 STUDS <br />EXTERI0R & BEARING STUDS <br />NOTE: NOTCH AND BORING <br />NOT TO OCCUR IN SAME <br />STUD SECTION <br />5/8" MINIMUM EDGE DISTANCE <br />2X4 STUDS, 3 1/4" DIAMETER <br />40% MAXIMUM STUD WIDTH. <br />1 3/8" DIAMETER MAXIMUM <br />@ 2X4 STUDS, 2 1/4" <br />DIAMETER MAXIMUM @ <br />@ 2X6 STUDS <br />TYPICAL ALL STUDS <br />NON-BEARING STUDS <br />60% MAXIMUM <br />STUD WIDTH <br />DIAMETER OF <br />WHERE SHOWN ON DRAWINGS. <br />2" DIAMETER MAXIMUM @ <br />60% MAXIMUM STUD WIDTH <br />2X4 STUDS. 3 1/4" DIAMETER <br />MAXIMUM @ 2X6 STUDS <br />DOUBLE STUDS <br />1 1/2"1 1/2" <br />NOTCHING NOT PERMITTED EXCEPT <br />NOTE: <br />DRILL 1"Ø HOLE <br />BEFORE CUTTING <br />NOTCH IN WOOD <br />JOIST OR RAFTER <br />TYP. PIPING/ELECTRICAL THRU PLATES <br />NOTCH <br />IN PLATE <br />(6) 16d NAILS <br />EACH END <br />0.058" THICK BY 1.5" WIDE <br />(MIN. SIZE) METAL STRAP <br />TYPICAL AT EACH PLATE CUT <br />PLATES <br />PLUMBING PIPE <br />NOTCH <br />IN PLATE <br />(6) 16d NAILS <br />EACH END <br />0.058" THICK BY 1.5" WIDE <br />(MIN. SIZE) METAL STRAP <br />TYPICAL AT EACH PLATE CUT <br />PLATES <br />ELECTRICAL WIRE <br />EXISTING <br />EXISTING <br />EXISTING <br />EXISTING <br />EXISTING <br />EXISTING <br />EXISTING <br />EXISTING <br />EXISTING <br />EXISTING <br />EXISTING <br />EXISTING <br />EXISTING <br />EXISTING <br />EXISTING <br />RI <br />V <br />E <br />R <br />S <br />I <br />D <br />E <br />, <br /> <br />C <br />A <br />L <br />I <br />F <br />O <br />R <br />N <br />I <br />A <br />JO <br />S <br />E <br /> <br />A <br />. <br /> <br />V <br />E <br />G <br />A <br />AS <br />S <br />I <br />S <br />T <br />A <br />N <br />T <br /> <br />C <br />I <br />V <br />I <br />L <br /> <br />E <br />N <br />G <br />. <br />DATE <br />SCALE <br />SHEET NO. <br />SHEET TITLE <br />08/01/2024 <br />1/4" = 1' <br />S-N <br />STRUCTURAL NOTES <br />& <br />REQUIREMENTS <br />CI <br />T <br />Y <br /> <br />O <br />F <br /> <br />S <br />A <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />12 <br />2 <br /> <br />N <br />O <br />R <br />T <br />H <br /> <br />B <br />E <br />W <br />L <br />E <br />Y <br /> <br />S <br />T <br />R <br />E <br />E <br />T <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br />L <br />I <br />F <br />O <br />R <br />N <br />I <br />A <br />, <br /> <br />9 <br />2 <br />7 <br />0 <br />3 <br />12 <br />2 <br /> <br />N <br />O <br />R <br />T <br />H <br /> <br />B <br />E <br />W <br />L <br />E <br />Y <br /> <br />S <br />T <br />R <br />E <br />E <br />T <br />NE <br />W <br /> <br />A <br />D <br />D <br />I <br />T <br />I <br />O <br />N <br /> <br />T <br />O <br /> <br />S <br />I <br />N <br />G <br />L <br />E <br /> <br />F <br />A <br />M <br />I <br />L <br />Y <br /> <br />R <br />E <br />S <br />I <br />D <br />E <br />N <br />C <br />E <br />LA <br />W <br />R <br />E <br />N <br />C <br />E <br /> <br />V <br /> <br />R <br />E <br />Y <br />HOLD - 122 N <br />Bewley St9/24/2024