Laserfiche WebLink
SITE PLAN <br />SCALE : 1/8" = 1' <br /> October 28, 2024 <br />A101 <br />PROJECT INFO <br />SITE PLAN <br />RO <br />S <br />S <br /> <br />C <br />O <br />M <br />M <br />O <br />N <br /> <br />A <br />P <br />A <br />R <br />T <br />M <br />E <br />N <br />T <br /> <br />R <br />E <br />M <br />O <br />D <br />E <br />L <br />12 <br />2 <br />3 <br /> <br />N <br /> <br />R <br />O <br />S <br />S <br /> <br />S <br />T <br />, <br /> <br />S <br />A <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />1 <br /> <br />DIGITAL STAMP <br />Br <br />i <br />a <br />n <br /> <br />E <br />n <br />r <br />i <br />g <br />h <br />t <br /> <br />& <br />Ad <br />r <br />i <br />a <br />n <br /> <br />D <br />e <br />a <br />d <br />w <br />y <br />l <br />e <br />r <br />De <br />s <br />i <br />g <br />n <br /> <br />D <br />r <br />a <br />f <br />t <br />i <br />n <br />g <br />34 <br />7 <br />2 <br /> <br />M <br />e <br />a <br />d <br />e <br /> <br />A <br />v <br />e <br />Sa <br />n <br /> <br />D <br />i <br />e <br />g <br />o <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />1 <br />1 <br />6 <br />61 <br />9 <br />. <br />2 <br />6 <br />9 <br />. <br />6 <br />4 <br />6 <br />0 <br />DESIGNER DIGITAL SIGNATURE <br />DOCUMENT <br />SHEET DATE <br />BLDG. PERMIT <br />PHOTO SURVEY <br />SEE SITE PLAN <br />LICENSED ARCHITECT <br />STATE O OFCALIFRNIAREN. 05-31-2025 <br />DONNAJ EANBROWN <br />No. C18361 <br />ENGINEER <br /> 10/28/24 <br />DATE <br /> 10/28/2024 <br />REVISIONS <br />SUBMIT DATE: <br />PROJECT NUMBER <br />105119822 <br />20583229 <br />30547435 <br />40539238 <br />05-13-2024 <br />1. M.E.P. & <br />STRUCTURAL <br />10.01.24 <br />2. CSG & <br />ELECTRICAL <br />10.28.24 <br />6' <br />- <br />9 <br />" <br />1223 N ROSS ST, SANTA ANA, CA 92701 <br />EXIST. BUILDING <br />N. <br /> <br />R <br />O <br />S <br />S <br /> <br />S <br />T <br />. <br />52 <br />' <br />- <br />7 <br />" <br />16 <br />' <br />- <br />1 <br />0 <br />" <br /> <br />20 <br />' <br />- <br />2 <br />" <br /> <br />28'-4" 91'-6" <br />119'-10"14'-0" <br />132'-0" <br />NO WORK PROPOSED <br />IN RIGHT-OF-WAY <br />20 <br />' <br />- <br />0 <br />" <br /> <br />10 <br />' <br />- <br />3 <br />" <br /> <br />℄ ALLEY <br />P1 <br />P2 P3 P4 <br />P6 <br />P7 <br />26 <br />' <br />- <br />9 <br />" <br /> <br />P8 <br />P5 <br />A <br />C <br />C <br />B <br />C <br />C <br />UP <br />UP <br />F <br />G <br />J <br />D <br />6' <br />- <br />2 <br />" <br />42 <br />' <br />- <br />8 <br />" <br /> <br />20 <br />' <br />- <br />2 <br />" <br /> <br />10 <br />' <br />- <br />3 <br />" <br /> <br />12'-2" <br />K <br />E I <br />I <br />I <br />M <br />K <br />3' <br />- <br />8 <br />" <br />16'-0" <br />L <br />L <br />H <br />H <br />N <br />O <br />TA <br />B <br />L <br />E <br />TA <br />B <br />L <br />E <br />2022 CALIFORNIA BUILDING CODE <br />2022 CALIFORNIA ELECTRICAL CODE <br />2022 CALIFORNIA MECHANICAL CODE <br />2022 CALIFORNIA PLUMBING CODE <br />2022 CALIFORNIA ENERGY CODE <br />2022 CALIFORNIA FIRE CODE <br />2022 CALIFORNIA HISTORICAL BUILDING CODE <br />2022 CALIFORNIA EXISTING BUILDING CODE <br />2022 CALIFORNIA GREEN BUILDING CODE <br />SANTA ANA MUNICIPAL CODE <br />PROJECT INFORMATION <br />VICINITY MAP <br />PLANS DRAWN BY: <br />PROJECT DATA ----------------------------------------------------------------------------------- <br />PROJECT ADDRESS:1223 N ROSS ST, SANTA ANA, CA 92701 <br />LEGAL DESCRIPTION:A TR HALESWORTHS ADD BLK LOT 10 <br />HALESWORTHS ADD LOT 10 ALL EX E 48 FT- <br />A.P.N.:398-541-04 <br />ZONING:P <br />OCCUPANCY:U, R-2 MUTI-FAMILY (5 OR MORE UNITS) <br />EXIST. BLDG. USE:12-UNIT APT. w/DETACHED GARAGES <br />YEAR BUILT:1961 <br />SPRINKLERED:NO <br />STORES:2-STORY <br />HISTORIC:NO <br />FLOOD ZONE:X-0602320163J <br />SCHOOL ZONE:SANTA ANA UNIFIED <br />SERVICES:NATURAL GAS, CITY WATER/SEWER <br />LOT SIZE:15,464 S.F. <br />F.A.R. EXISTING:7,853 S.F. / 15,464 S.F. = 51% (NO CHANGE) <br />EXISTING 1ST FLOOR 3,937 S.F. <br />EXISTING 2ND FLOOR 3,916 S.F. <br />BUILDING FOOTPRINT(S):7,163 S.F. / 15,464 S.F. = 46% (NO CHANGE) <br />EXIST. BUILDING 4,037 S.F. <br />EXIST. BALCONY 464 S.F. <br />EXIST. DETACHED GARAGE 2,662 S.F. <br />PROJECT DESCRIPTION ---------------------------------------------------------------------------- <br />1. CODE ENFORCEMENT: CORRECT TO CODE AND INSPECT ALL INTERIOR AND <br />EXTERIOR REMODEL WORK DONE TO THE APARTMENT BUILDING AND DETACHED <br />MULTI-GARAGE BUILDING WITHOUT A PERMIT. <br />2. APARTMENT BUILDING REMODEL INCLUDES: <br />2.1. RE-ROOF OF ENTIRE BUILDING <br />2.2. ALL WINDOWS, AND DOORS ARE NEW AND WILL MAINTAIN THE SAME SIZE, <br />OPERATION TYPE, AND SILL HEIGHT. <br />2.3. NEW WOOD SIDING ADDED TO EXTERIOR. <br />2.4. NEW 20 S.F. METAL AWNING ADDED OVER DOOR OF UNIT #1. <br />2.5. ADD GUTTERS TO NORTH SIDE OF BUILDING <br />2.6. NEW BALCONY RAILING AND STAIR RAILING. <br />2.7. ALL ELECTRICAL TO BE BROUGHT UP TO CURRENT CODE . <br />2.8. NEW EXTERIOR AND INTERIOR LIGHTING, SWITCHES, RECEPTACLES AND <br />DEDICATED CIRCUITS. <br />2.9. UPGRADE ALL ELECTRIC PANELS IN UNITS AND HOUSE PANEL TO PROVIDE <br />SPACE FOR FUTURE UPGRADES. <br />2.10. UPGRADE MAIN ELECTRICAL METER FROM 400A TO 600A. <br />2.11. NEW MINI-SPLIT SYSTEM FOR EACH UNIT. <br />2.12. ALL MECHANICAL TO BE BROUGHT UP TO CURRENT CODE. <br />2.13. ALL PLUMBING TO BE BROUGHT UP TO CURRENT CODE. <br />2.14. CAP OFF OLD WALL MOUNT GAS HEATER LINES. <br />2.15. INSTALL NEW LAUNDRY PLUMBING LINES IN EACH UNIT. <br />2.16. ALL WATER FIXTURES AND APPLIANCES ARE NEW. <br />2.17. REMOVAL OF KITCHEN PARTITION WALL TO CREATE AN OPEN CONCEPT . <br />2.18. VERIFY FIRE SEPARATION BETWEEN ADJOINING WALLS AND CEILING IN UNITS <br />3. DETACHED GARAGE REMODEL INCLUDES: <br />3.1. NEW EXTERIOR WOOD SIDING ON WEST SIDE OF BUILDING <br />3.2. NEW EXTERIOR LIGHTING <br />3.3. NEW INTERIOR SWITCHES, RECEPTACLES, AND GARAGE DOOR OPENERS IN <br />EACH GARAGE <br />3.4. NEW METAL GARAGE DOORS <br />3.5. REPLACE WATER DAMAGED WOOD FRAMING IN KIND. <br />3.6. RE-ROOF GARAGE <br />4. NEW OUTDOOR BBQ GRILL AND GAS PLUMBING LINES IN COURTYARD. <br />5. PREVIOUS EXPIRED PERMIT REFERENCE: # 102102495 <br />6. OBTAIN FRONT YARD FENCE PERMIT FOR EXISTING FENCE. <br />DESIGNER/PROJECT MANAGER <br />ADRIAN DEADWYLER <br />909.559.0774 <br />ADEADWYLER@GMAIL.COM <br />PROPERTY OWNER(S): <br />MICHAEL CHEN <br />408.544.0927 <br />MICHAEL@CAPEROBBIN.COM <br />GOVERNING CODES UNDERGROUND SERVICE ALERT <br />CALL 811 <br />TWO WORKING DAYS BEFORE YOU DIG <br />SECTION 4216/4217 OF THE GOVERNMENT <br />CODE REQUIRES A DIG ALERT IDENTIFICATION <br />NUMBER BE ISSUED BEFORE A PERMIT TO <br />EXCAVATE WILL BE VALID. FOR YOUR DIG <br />ALERT IDENTIFICATION NUMBER CALL <br />1. ALL EXISTING CONDITIONS INDICATED ON THESE DRAWINGS, INCLUDING BUT NOT <br />LIMITED TO SIZES AND LOCATIONS OF FOOTINGS, BEAMS, HEADERS, RAFTERS, JOISTS, <br />TRUSSES, ETC, ARE BASED UPON INFORMATION PROVIDED BY THE CONTRACTOR <br />AND/OR PROPERTY OWNER OR NONDESTRUCTIVE FIELD SURVEY. THESE EXISTING <br />CONDITIONS MUST BE VERIFIED! <br />2. CONTRACTOR/OWNER TO NOTIFY BRIAN ENRIGHT & ADRIAN DEADWYLER DESIGN <br />AND/OR INSPECTOR IMMEDIATELY IF DURING CONSTRUCTION, PRE-EXISTING OR <br />UNFORESEEN CONDITIONS OCCUR THAT DIFFER FROM THE CONSTRUCTION <br />DOCUMENTATION AND THAT MAY AFFECT CONSTRUCTION AND OR THE PERMITTED <br />SCOPE OF WORK. <br />3. WALK THRU AND VERIFY PLUMBING AND ELECTRICAL LAYOUT WITH OWNER. CURRENT <br />PLAN LAYOUT MAY VARY. <br />EXISTING CONDITIONS <br />SOME PRE-EXISTING CONDITION CANNOT BE VERIFIED BY VISUAL INSPECTION IN THE DESIGN <br />PHASE OF CONSTRUCTION. FINAL FLOOR PLAN LAYOUTS MAY DIFFER DUE TO EXISTING <br />CONDITIONS OR BY OWNER REQUEST. <br />ARCHITECT <br />DONNA J. BROWN <br />206.949.9939 <br />DONNA@DJBARCHITECT.COM <br />DEFERRED SUBMITTAL <br />ITEMS BELOW WILL BE WILL BE PROCESSED AS A DEFERRED SUBMITTAL. NOTE, THE <br />SUBMITTAL PROCESS MUST BE COMPLETED IN ORDER TO OBTAIN A FINAL INSPECTION. <br />1. LANDSCAPE PLAN: PURSUANT SAMC 41-609 (NS-3038), NEW LANDSCAPE PROJECTS WITH <br />AN AGGREGATE LANDSCAPE AREA OF 500 SQUARE FEET OR MORE OR REHABILITATED <br />LANDSCAPE PROJECTS WITH AN AGGREGATE LANDSCAPE AREA EQUAL TO OR GREATER <br />THAN 2,500 SQUARE FEET ARE SUBJECT TO THE WATER EFFICIENCY LANDSCAPE <br />ORDINANCE AND REQUIRE PLANS DRAFTED AND STAMPED BY A CERTIFIED LANDSCAPE <br />PROFESSIONAL AND PERMITS. <br />1.1. TOTAL REHABILITATED LANDSCAPE AREA EQUALS 3,974. <br />A101 PROJECT INFO / SITE PLAN <br />A102 AC AUTHORIZATION LETTERS <br />A201 EXIST. DEMO FLOOR PLANS <br />A202 PROP. FLOOR PLAN <br />A203 GARAGE FLOOR PLAN <br />A204 ROOF PLAN <br />A301 APARTMENT ELEVATIONS <br />A302 GARAGE ELEVATIONS <br />A401 GENERAL NOTES <br />SN1 STRUCTURAL NOTES <br />S1 STRUCTURAL FLOOR FRAMING PLAN <br />S2 STRUCTURAL ROOF FRAMING PLAN <br />S3 STRUCTURAL ROOF FRAMING GARAGE <br />SD1 FRAMING DETAILS <br />M001 MECHANICAL SCHEDULES & NOTES <br />M002 MECHANICAL DETAILS <br />M101 MECHANICAL PLAN, 1ST FLOOR <br />M102 MECHANICAL PLAN, 2ND FLOOR <br />M103 MECHANICAL ROOF PLAN <br />M104 MECHANICAL PLAN, GARAGE <br />MT01 TITLE-24, MECH PART 1 <br />MT02 TITLE-24, MECH PART 2 <br />MT03 TITLE-24, MECH PART 3 <br />MT04 TITLE-24, MECH PART 4 <br />SHEET INDEX <br />1. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND ALL CONDITIONS AT JOB SITE <br />INCLUDING BUILDING AND SITE CONDITIONS BEFORE COMMENCING WORK AND BE <br />RESPONSIBLE FOR SAME. ALL DISCREPANCIES SHALL BE REPORTED TO BRIAN ENRIGHT & <br />ADRIAN DEADWYLER DESIGN. UNLESS EXPRESSLY STIPULATED, NO ADDITIONAL <br />ALLOWANCE WILL BE MADE IN THE CONTRACTOR AND/OR MANUFACTURER'S FAVOR BY <br />VIRTU OF ERRORS, AMBIGUITIES AND/OR OMISSIONS WHICH SHOULD HAVE BEEN <br />DISCOVERED DURING THE PREPARATION OF THE BID ESTIMATE AND DIRECTED TO THE <br />ATTENTION OF BRIAN ENRIGHT & ADRIAN DEADWYLER DESIGN IN A TIMELY MANNER. ANY <br />ERRORS, AMBIGUITIES AN/OR OMISSIONS IN THE DRAWINGS OR SPECIFICATIONS SHALL <br />BE REPORTED TO BRIAN ENRIGHT & ADRIAN DEADWYLER DESIGN IMMEDIATELY. NO WORK <br />IS TO BE STARTED BEFORE CORRECTION(S) ARE MADE, UNLESS OTHERWISE DIRECTED BY <br />BRIAN ENRIGHT DESIGN. THE CONTRACTOR SHALL PROVIDE TEMPORARY BRACING AS <br />REQUIRED UNTIL ALL PERMANENT CORRECTIONS AND STIFFENERS HAVE BEEN <br />INSTALLED. <br />2. THE CONTRACTOR SHALL COORDINATE WITH THE BUILDING DEPARTMENT FOR ALL <br />BUILDING DIMENSIONS. THE DETAILS SHOWN ARE TYPICAL AND SHALL BE USED FOR LIKE <br />OR SIMILAR CONDITIONS NOT SHOWN. VARIATIONS AND MODIFICATIONS TO WORK ON <br />THESE DRAWINGS SHALL NOT BE CARRIED OUT WITHOUT WRITTEN PERMISSION FROM <br />BRIAN ENRIGHT & ADRIAN DEADWYLER DESIGN. <br />3. PLAN DIMENSIONS ARE TO FACE OF FINISHED WALL OR FACE OF CONCRETE, U.O.N. <br />4. CONTRACTOR SHALL BE RESPONSIBLE FOR REPLACING ANY LANDSCAPE ELEMENTS <br />INDICATED TO REMAIN IF THEY ARE DAMAGED BY CONSTRUCTION. <br />5. DO NOT SCALE DRAWINGS FOR DIMENSIONS. WHERE THERE IS A DISCREPANCY BETWEEN <br />WRITTEN DIMENSIONS AND ACTUAL DIMENSIONS OR CONDITIONS, CONTACT BRIAN <br />ENRIGHT & ADRIAN DEADWYLER DESIGN FOR INTERPRETATION PRIOR TO <br />COMMENCEMENT OF WORK. <br />6. ALL OUTDOOR LIGHTING SHALL COMPLY WITH THE CITY AND/OR COUNTY LIGHTING AND <br />POLLUTION ORDINANCE <br />7. DURING CONSTRUCTION, AT LEAST ONE EXTINGUISHER SHALL BE PROVIDE ON EACH <br />FLOOR LEVEL AT EACH STAIRWAY, IN ALL STORAGE AND CONSTRUCTION SHEDS, IN <br />LOCATIONS WHERE FLAMMABLE OR COMBUSTIBLE LIQUIDS ARE STORED OR USED, AND <br />WHERE OTHER SPECIAL HAZARDS ARE PRESENT PER CFC SECTION 3315.1 <br />8. BUILDINGS UNDERGOING CONSTRUCTION, ALTERATION, OR DEMOLITION SHALL CONFORM <br />TO CFC CHAPTER 33. WELDING, CUTTING, AND OTHER HOT WORK SHALL BE IN <br />CONFORMANCE WITH CFC CHAPTER 35. <br />GENERAL NOTES <br />HERS VERIFICATION SUMMARY <br />REQUIRED SPECIAL FEATURES: <br />THE FOLLOWING ARE FEATURES THAT MUST BE INSTALLED AS CONDITION FOR MEETING <br />THE MODELED ENERGY PERFORMANCE <br />· DUCTS WITH HIGH LEVEL OF INSULATION <br />· CEILING WITH HIGH LEVEL OF INSULATION <br />HERS FEATURE SUMMARY: <br />BUILDING-LEVEL VERIFICATIONS: <br />· KITCHEN RANGE HOOD <br />COOLING SYSTEM VERIFICATIONS: <br />· -- NONE -- <br />HEATING SYSTEM VERIFICATIONS: <br />· VERIFIED HEAT PUMP RATED HEATING CAPACITY <br />HVAC DISTRIBUTION SYSTEM VERIFICATIONS: <br />· -- NONE -- <br />DOMESTIC HOT WATER SYSTEM VERIFICATIONS: <br />· -- NONE -- <br />1. PROPERLY COMPLETED AND SIGNED CERTIFICATES OF INSTALLATION (CF2R <br />FORMS) SHALL BE PROVIDED TO THE INSPECTOR IN THE FIELD. FOR PROJECTS <br />REQUIRING HERS VERIFICATION, THE CF2R FORMS SHALL BE REGISTERED WITH A <br />CALIFORNIA-APPROVED HERS PROVIDER DATA REGISTRY.” CF2R FORMS ARE <br />AVAILABLE AT <br />2. PROPERLY COMPLETED CERTIFICATES OF VERIFICATION (CF3R FORMS) SHALL BE <br />PROVIDED TO THE INSPECTOR IN THE FIELD FOR ITEMS REQUIRING HERS <br />VERIFICATION. CF3R FORMS SHALL BE REGISTERED WITH A <br />CALIFORNIA-APPROVED HERS PROVIDER DATA REGISTRY.” <br />1. STRUCTURAL ENGINEER - <br />LAMAR ENGINEERING INC. <br />··PRINCIPLE ENGINEER: LUIS LABRADA <br />··619.370.9515 | LLABRADA@LAMARENG.COM <br />··809 BOWSPRIT ROAD, SUITE 105 <br />CHULA VISTA, CA 91914 <br />2. MECHANICAL, ELECTRICAL, PLUMBING ENGINEERs: <br />PRO ENGINEERING CONSULTING INC. <br />··PROJECT MANAGER: MOHAN S <br />··888.776.1691 | MOHAN@PROENGC.COM <br />··2712 LOKER AVE WEST, #1063 <br />CARLSBAD, CA. 92010 <br />ENGINEER OF RECORD <br />SEE SHEET MT01 <br />1 <br />2 <br />E001 NON-RESIDENTIAL SCHEDULES, <br />NOTES & DETAILS <br />E002 RESIDENTIAL SCHEDULES, <br />NOTES & DETAILS <br />E003 PANEL SCHEDULES & 1-LINE <br />E004 PANEL SCHEDULES <br />E005 PANEL SCHEDULES <br />E006 TITLE-24 LTS, PART 1 <br />E007 TITLE-24 LTS, PART 2 <br />E100 ELECTRICAL SITE PLAN <br />E101 LIGHTING PLAN, GARAGE <br />E102 POWER & EQUIPMENT PLAN, GARAGE <br />E201 LIGHTING PLAN, FIRST FLOOR <br />E202 POWER PLAN, FIRST FLOOR <br />E203 EQUIPMENT PLAN, FIRST FLOOR <br />E301 LIGHTING PLAN, SECOND FLOOR <br />E302 POWER PLAN, SECOND FLOOR <br />E303 EQUIPMENT PLAN, SECOND FLOOR <br />P001 PLUMBING SCHEDULES & NOTES <br />P002 PLUMBING DETAILS <br />P003 PLUMBING DETAILS <br />P100 PLUMBING SITE PLAN <br />P101 WASTE & VENT PLAN, 1ST & 2ND FLOOR <br />P102 WASTE & VENT PLAN, ISOMETRICS <br />P201 HW & CW PLAN, 1ST & 2ND FLOOR <br />P202 HW & CW PLAN, ISOMETRICS <br />P301 GAS PLAN, 1ST & 2ND FLOOR <br />P302 GAS PLAN, ISOMETRICS <br />P401 ROOF PLUMBING <br />GN1 CAL-GREEN GENERAL NOTES <br />2 <br />PHOTO P1 PHOTO P2 PHOTO P3 PHOTO P4 <br />PHOTO P5 PHOTO P6 PHOTO P7 <br />PHOTO P8 <br />· ALL STORM WATER RUNOFF FROM EXISTING, PROPOSED, AND/OR REPLACED <br />IMPERVIOUS AREAS SHALL BE ROUTED TO PERVIOUS SURFACES OR <br />LANDSCAPING PRIOR TO REACHING THE PUBLIC DRAIN SYSTEM. <br />A. EXISTING APARTMENT BUILDING: 12 UNITS - 7,853 S.F. <br />B. EXISTING GARAGE - 2,662 S.F. <br />C. SIDEWALK / WALKWAY / PAVERS <br />D. ELECTRIC METER BOX - 13 PANELS <br />E. GAS METER <br />F. EXISTING 7' HT SECURITY GATED ENTRY <br />G. 3' HT WOOD FENCE PER FRONT YARD FENCE APPLICATION <br />H. EXISTING 6'-8" HT BLOCK WALL <br />I. EXISTING 6'-8" HT WOOD FENCE <br />J. EXIST. 1 1 2" WATER METER <br />K. DRIVEWAY(S) <br />L. POWER LINE POLE <br />M. NEW GAS LINE TO BBQ GRILL <br />N. FIRE HYDRANT <br />O. FIRE EXTINGUISHER / BOX <br />A = SEE SITE PLAN SITE PLAN KEYNOTES <br />SITE ID IMPERVIOUS ITEM DIMENSIONS <br />NEW OR <br />REPLACED AREA <br />(S.F.) <br />EXISTING AREA <br />(S.F.) <br />1 APARTMENT BLDG VARIOUS 4,037 S.F. <br />REP. FULL ROOF 4,037 S.F. <br />2 BALCONY VARIOUS 50S.F. <br />REP. RAILING 464 S.F. <br />3 DET. GARAGE 20'-2"x132'-0"0 S.F.2,662 S.F. <br />4 CONC. WALKWAYS VARIOUS 0 S.F.1,904 S.F. <br />5 DRIVEWAY(S) 10'-0"x132'-0"0 S.F.1,320 S.F. <br />IMPERVIOUS AREA TABLE <br />LAND DISTURBANCE: 50 S.F. <br />LOT SIZE: 15,464 S.F. <br />TOTAL IMPERVIOUS AREA: 10,387 S.F. <br />TOTAL PERVIOUS AREA: 5,077 S.F. <br />AREA OF WORK <br />DIRT - PERVIOUS <br />FRONT YARD FENCE ELEVATION <br />GROUND LINE <br />3' <br />- <br />0 <br />" <br />WOOD FENCE NOT TO SCALE <br />4" <br /> <br />M <br />A <br />X <br /> <br />W <br />I <br />D <br />T <br />H <br />4" <br /> <br />M <br />I <br />N <br />. <br /> <br />S <br />P <br />A <br />C <br />I <br />N <br />G <br />EQ. <br />4' MAX SPACING <br />EQ. <br />4' MAX SPACING <br />1 <br />Bldg #105119822 <br />Elect # 20583229 <br />Mech # 40539238 <br />Plumb # 30547435 <br />APPROVALS: <br /> <br />PLNG - C. Santana <br />BLDG - CSG <br />ELECT - M. Smith <br />PLUMB/MECH - T. Luka <br />HOLD - 1223 N Ross <br />St3/4/2025