My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
HOLD - 1223 N Ross St - Plan
PBA
>
Building
>
ProjectDox
>
R
>
Ross St
>
1223 N Ross St
>
HOLD - 1223 N Ross St - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/1/2025 12:11:32 PM
Creation date
6/1/2025 12:11:13 PM
Metadata
Fields
Template:
Plan
Permit Number
20583229
30547435
40539238
105119822
Full Address
1223 N Ross St
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
77
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
2022 RESIDENTIAL MANDATORY MEASURES <br />TABLE 4.303.2 FIXTURE FLOW RATES <br />MAXIMUM FLOW RATE AT 20 percent REDUCTION <br />FIXTURE TYPE <br />Showerheads 1.8 gpm @ 80 psi <br />Lavatory faucets, residential 1.2 gpm @ 60 psi2 <br />Kitchen faucets 1.8 gpm @ 60 psi <br />Gravity tank-type water closets 1.28 gallons/flush1 <br />Flushometer tank water closets 1.28 gallons/flush1 <br />Flushometer valve water closets 1.28 gallons/flush1 <br />Electromechanical hydraulic water closet 1.28 gallons/flush1 <br />Urinals .5 gallon/flush <br />Includes single and dual flush water closets with an effective flush of 1.28 gallons or less. Single flush <br />toilets—The effective flush volume shall not exceed 1.28 gallons (4.8liters).The effective flush volume is the <br />average flush volume when tested in accordance with ASME A112.19.233.2. <br />Dual flush toilets—The effective flush volume shall not exceed 1.28 gallons (4.8 liters). The effective flush <br />volume is defined as the composite, average flush volume of two reduced flushes and one full flush. Flush <br />volumes will be tested in accordance with ASME A112.19.2 and ASME A112.19.14. <br />Lavatory faucets shall not have a flow rate less than 0.8 gpm at 20 psi. <br />PLUMBING WASTE & VENT SIZE CHART <br />PIPE SIZING PER CPC 2022, 703.2 <br />PIPE SIZE MAX. UNIT (WASTE)MAX. UNIT (VENT) <br />1 1/2"1 8 <br />2"8 24 <br />2 1/2"14 48 <br />3"35 84 <br />4"216 256 <br />CLEANOUT SIZING PERC CPC 2022, TABLE 707.1 <br />PIPE SIZE SIZE OF CLEANOUT THREADS PER INCH <br />1 1/2"1 1/2"11 1/2" <br />2"1 1/2"11 1/2" <br />2 1/2"2 1/2"8 <br />3"2 1/2"8 <br />4" & LARGER 3 1/2"8 <br />PROJECT INFORMATION <br />PLANS DRAWN BY: <br />PROJECT DATA ----------------------------------------------------------------------------------- <br />PROJECT ADDRESS:1223 N ROSS ST, SANTA ANA, CA 92701 <br />LEGAL DESCRIPTION: A TR HALESWORTHS ADD BLK LOT 10 <br />HALESWORTHS ADD LOT 10 ALL EX E 48 FT- <br />A.P.N.: 398-541-04 <br />ZONING:P <br />OCCUPANCY:U, R-2 MUTI-FAMILY (5 OR MORE UNITS) <br />EXIST. BLDG. USE:12-UNIT APT. w/DETACHED GARAGES <br />YEAR BUILT:1961 <br />SPRINKLERED: NO <br />STORES:2-STORY <br />HISTORIC:NO <br />FLOOD ZONE:X-0602320163J <br />SCHOOL ZONE:SANTA ANA UNIFIED <br />SERVICES:NATURAL GAS, CITY WATER/SEWER <br />LOT SIZE:15,464 S.F. <br />F.A.R. EXISTING:7,853 S.F. / 15,464 S.F. = 51% (NO CHANGE) <br />EXISTING 1ST FLOOR 3,937 S.F. <br />EXISTING 2ND FLOOR 3,916 S.F. <br />BUILDING FOOTPRINT(S):7,163 S.F. / 15,464 S.F. = 46% (NO CHANGE) <br />EXIST. BUILDING 4,037 S.F. <br />EXIST. BALCONY 464 S.F. <br />EXIST. DETACHED GARAGE 2,662 S.F. <br />PROJECT DESCRIPTION ---------------------------------------------------------------------------- <br />1.CODE ENFORCEMENT: CORRECT TO CODE AND INSPECT ALL INTERIOR AND <br />EXTERIOR REMODEL WORK DONE TO THE APARTMENT BUILDING AND DETACHED <br />MULTI-GARAGE BUILDING WITHOUT A PERMIT. <br />2.APARTMENT BUILDING REMODEL INCLUDES: <br />2.1.RE-ROOF OF ENTIRE BUILDING <br />2.2.ALL WINDOWS, AND DOORS ARE NEW AND WILL MAINTAIN THE SAME SIZE, <br />OPERATION TYPE, AND SILL HEIGHT. <br />2.3.NEW WOOD SIDING ADDED TO EXTERIOR. <br />2.4.NEW 20 S.F. METAL AWNING ADDED OVER DOOR OF UNIT #1. <br />2.5.ADD GUTTERS TO NORTH SIDE OF BUILDING <br />2.6.NEW BALCONY RAILING AND STAIR RAILING. <br />2.7.ALL ELECTRICAL TO BE BROUGHT UP TO CURRENT CODE . <br />2.8.NEW EXTERIOR AND INTERIOR LIGHTING, SWITCHES, RECEPTACLES AND <br />DEDICATED CIRCUITS. <br />2.9.UPGRADE ALL ELECTRIC PANELS IN UNITS AND HOUSE PANEL TO PROVIDE <br />SPACE FOR FUTURE UPGRADES. <br />2.10.UPGRADE MAIN ELECTRICAL METER FROM 400A TO 600A. <br />2.11.NEW MINI-SPLIT SYSTEM FOR EACH UNIT. <br />2.12.ALL MECHANICAL TO BE BROUGHT UP TO CURRENT CODE. <br />2.13.ALL PLUMBING TO BE BROUGHT UP TO CURRENT CODE. <br />2.14.CAP OFF OLD WALL MOUNT GAS HEATER LINES. <br />2.15.INSTALL NEW LAUNDRY PLUMBING LINES IN EACH UNIT. <br />2.16.ALL WATER FIXTURES AND APPLIANCES ARE NEW. <br />2.17.REMOVAL OF KITCHEN PARTITION WALL TO CREATE AN OPEN CONCEPT . <br />2.18.VERIFY FIRE SEPARATION BETWEEN ADJOINING WALLS AND CEILING IN UNITS <br />3.DETACHED GARAGE REMODEL INCLUDES: <br />3.1.NEW EXTERIOR WOOD SIDING ON WEST SIDE OF BUILDING <br />3.2.NEW EXTERIOR LIGHTING <br />3.3.NEW INTERIOR SWITCHES, RECEPTACLES, AND GARAGE DOOR OPENERS IN <br />EACH GARAGE <br />3.4.NEW METAL GARAGE DOORS <br />3.5.REPLACE WATER DAMAGED WOOD FRAMING IN KIND. <br />3.6.RE-ROOF GARAGE <br />4.NEW OUTDOOR BBQ GRILL AND GAS PLUMBING LINES IN COURTYARD. <br />5.PREVIOUS EXPIRED PERMIT REFERENCE: # 102102495 <br />6.OBTAIN FRONT YARD FENCE PERMIT FOR EXISTING FENCE. <br />DESIGNER/PROJECT MANAGER <br />ADRIAN DEADWYLER <br />909.559.0774 <br />ADEADWYLER@GMAIL.COM <br />PROPERTY OWNER(S): <br />MICHAEL CHEN <br />408.544.0927 <br />MICHAEL@CAPEROBBIN.COM <br />ARCHITECT <br />DONNA J. BROWN <br />206.949.9939 <br />DONNA@DJBARCHITECT.COM <br />1 <br />1 <br />REVISIONS <br />SHEET TITLE: <br />SUBMIT DATE: <br />PROJECT NUMBER <br />RO <br />S <br />S <br /> <br />C <br />O <br />M <br />M <br />O <br />N <br /> <br />A <br />P <br />A <br />R <br />T <br />M <br />E <br />N <br />T <br /> <br />R <br />E <br />M <br />O <br />D <br />E <br />L <br />12 <br />2 <br />3 <br /> <br />N <br /> <br />R <br />O <br />S <br />S <br /> <br />S <br />T <br />, <br /> <br />S <br />A <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />1 <br />Br <br />i <br />a <br />n <br /> <br />E <br />n <br />r <br />i <br />g <br />h <br />t <br /> <br />& <br />Ad <br />r <br />i <br />a <br />n <br /> <br />D <br />e <br />a <br />d <br />w <br />y <br />l <br />e <br />r <br />De <br />s <br />i <br />g <br />n <br /> <br />D <br />r <br />a <br />f <br />t <br />i <br />n <br />g <br />34 <br />7 <br />2 <br /> <br />M <br />e <br />a <br />d <br />e <br /> <br />A <br />v <br />e <br />Sa <br />n <br /> <br />D <br />i <br />e <br />g <br />o <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />1 <br />1 <br />6 <br />61 <br />9 <br />. <br />2 <br />6 <br />9 <br />. <br />6 <br />4 <br />6 <br />0 <br />DESIGNER SIGNATURE <br />DOCUMENT <br />JOB NO.: 23-515 <br />WINDOW PERMIT <br />---------- <br />00-00-2023 <br /> 1 PLAN CHECK 09302024 <br />SHEET NO.: <br />PLOT DATE: 09-30-24 <br />CHECKED BY: RP <br />SCALE: <br />CONSULTANT: <br /> NONE <br />PLUMBING <br />SCHEDULES & <br />NOTES <br />SCALE: NONE <br />P001PLUMBING SCHEDULES & NOTES <br />HOLD - 1223 N Ross <br />St3/4/2025
The URL can be used to link to this page
Your browser does not support the video tag.