November 21, 2024 <br />A401 <br />REVISIONS <br />GENERAL NOTES <br />SUBMIT DATE: <br />PROJECT NUMBER <br />RO <br />S <br />S <br /> <br />C <br />O <br />M <br />M <br />O <br />N <br /> <br />A <br />P <br />A <br />R <br />T <br />M <br />E <br />N <br />T <br /> <br />R <br />E <br />M <br />O <br />D <br />E <br />L <br />12 <br />2 <br />3 <br /> <br />N <br /> <br />R <br />O <br />S <br />S <br /> <br />S <br />T <br />, <br /> <br />S <br />A <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />1 <br />STAMP <br />Br <br />i <br />a <br />n <br /> <br />E <br />n <br />r <br />i <br />g <br />h <br />t <br /> <br />& <br />Ad <br />r <br />i <br />a <br />n <br /> <br />D <br />e <br />a <br />d <br />w <br />y <br />l <br />e <br />r <br />De <br />s <br />i <br />g <br />n <br /> <br />D <br />r <br />a <br />f <br />t <br />i <br />n <br />g <br />34 <br />7 <br />2 <br /> <br />M <br />e <br />a <br />d <br />e <br /> <br />A <br />v <br />e <br />Sa <br />n <br /> <br />D <br />i <br />e <br />g <br />o <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />1 <br />1 <br />6 <br />61 <br />9 <br />. <br />2 <br />6 <br />9 <br />. <br />6 <br />4 <br />6 <br />0 <br />DESIGNER SIGNATURE <br />DOCUMENT <br />SHEET DATE <br />BLDG. PERMIT <br />105119822 <br />20583229 <br />30547435 <br />40539238 <br />05-13-2024 <br />1.M.E.P. & <br />STRUCTURAL <br />10.01.24 <br />2.CSG & <br />ELECTRICAL <br />10.28.24 <br />LICENSED ARCHITECT <br />STATE O OFCALIFRNIAREN. 05-31-2025 <br />DONNAJ E A NBROWN <br />No. C18361 <br />DIGITAL STAMP <br />DESIGNER DIGITAL SIGNATURE <br /> 11/21/24 <br />DATE <br /> 11/21/2024 <br />1.VERIFY OR PROVIDE (1) LAYER 5 8" FIRE RATED GWB (TYPE X) (STAGGER BUTT JOINTS <br />PERP. TO STUDS) ENTIRE UNDER STAIR STORAGE CEILING AND (1) LAYER 1 2" FIRE RATED <br />GWB (TYPE X) ON ALL WALLS <br />2.VERIFY OR PROVIDE (1) LAYER 5 8" FIRE RATED GWB (TYPE X) (STAGGER BUTT JOINTS <br />PERP. TO STUDS) ENTIRE GARAGE CEILING AND (1) LAYER 1 2" FIRE RATED GWB (TYPE X) <br />ON ENTIRE WALL FLOOR TO ROOF SHEATHING ON GARAGE SIDE OF WALLS SEPARATING <br />GARAGE AND DWELLING UNIT <br />3.VERIFY OR PROVIDE (1) LAYER 5 8" FIRE RATED GWB (TYPE X) (STAGGER BUTT JOINTS <br />PERP. TO STUDS) ENTIRE SHAFT CEILING AND (1) LAYER 1 2" FIRE RATED GWB (TYPE X) <br />ON ENTIRE WALL FLOOR TO ROOF SHEATHING ON STORAGE SIDE OF WALLS <br />SEPARATING SHAFT AND DWELLING UNIT <br />4.* NO OPENINGS TO EXTERIOR - FIRE TAPE AND TREAT JOINTS AND INTERIOR OPENINGS <br />- AT LEAST 3 INCHES OF WOOD WHERE NO DRYWALL OCCURS, RIM JOIST, OUTSIDE <br />CORNERS, BLOCKING BETWEEN JOISTS OR RAFTERS <br />5.DOORS BETWEEN GARAGES & LIVING SPACES & ALL SHAFTS TO BE SELF-CLOSING AND <br />SELF-LATCHING: SOLID WOOD OF NOT LESS THAN 1-3/8" THICK, SOLID OR HONEYCOMB <br />CORE STEEL OF NOT LESS THAN 1-3/8" THICK OR A 20-MINUTE RATED FIRE DOOR. <br />6.DUCTS IN THE GARAGE/UNDER-STAIR AREA AND DUCTS PENETRATING THE WALLS OR <br />CEILINGS SEPARATING THE DWELLING FROM THE GARAGE/UNDER-STAIR AREA SHALL <br />BE CONSTRUCTED OF MIN NO. 26 GAUGE SHEET METAL OR OTHER APPROVED <br />MATERIAL AND SHALL HAVE NO OPENINGS INTO THE GARAGE. <br />7.FASTENERS FOR PRESERVATIVE TREATED AND FIRE-RETARDANT-TREATED WOOD <br />SHALL BE OF HOT DIPPED ZINC COATED GALVANIZED STEEL, STAINLESS STEEL, <br />SILICONE BRONZE, OR COPPER. <br />SPARK ARRESTORS: <br />ALL CHIMNEYS ATTACHED TO ANY APPLIANCE OR FIREPLACE THAT BURNS SOLID FUEL SHALL <br />BE EQUIPPED WITH AN APPROVED SPARK ARRESTER. WHERE A SPARK ARRESTOR IS <br />INSTALLED ON A MASONRY CHIMNEY, THE SPARK ARRESTOR SHALL MEET ALL OF THE <br />FOLLOWING REQUIREMENTS: <br />1.THE NET FREE AREA OF THE ARRESTOR SHALL BE NOT LESS THAN FOUR TIMES <br />2.THE NET FREE AREA OF THE OUTLET OF THE CHIMNEY FLUE IT SERVES. <br />3.THE ARRESTOR SCREEN SHALL HAVE HEAT AND CORROSION RESISTANCE EQUIVALENT <br />TO 12 GAGE WIRE, 19-GAGE GALVANIZED STEEL OR 24-GAGE STAINLESS STEEL. <br />4.OPENINGS SHALL NOT PERMIT THE PASSAGE OF SPHERES HAVING A DIAMETER <br />GREATER THAN 1/2 INCH (12.7 MM) NOR BLOCK THE PASSAGE OF SPHERES HAVING A <br />DIAMETER LESS THAN 3/8 INCH (9.5 MM). <br />5.THE SPARK ARRESTOR SHALL BE ACCESSIBLE FOR CLEANING AND THE SCREEN OR <br />CHIMNEY CAP SHALL BE REMOVABLE TO ALLOW FOR CLEANING OF THE CHIMNEY FLUE. <br />1.LANDINGS @ EACH SIDE OF DOORS SHALL BE LEVEL. THE WIDTH OF EACH LANDING SHALL <br />BE NOT BE LESS THAN THE DOOR SERVED. <br />2.EVERY LANDING SHALL HAVE A MINIMUM DIMENSION OF 36" MEASURED IN THE DIRECTION <br />OF TRAVEL. <br />3.SLOPE TO DRAIN LANDING AWAY FROM STRUCTURE 1 <br />4"/FT MIM <br />4.LANDINGS @ IN-SWINGING DOORS SHALL MEASURE A MAXIMUM OF 1" BELOW THE TOP OF <br />THE THRESHOLD OF THE DOOR. <br />5.STEPS OR LANDINGS AT IN-SWINGING DOORS SHALL MEASURE NO MORE THAN 7" TO THE <br />TOP OF THE THRESHOLD OF THE DOOR. <br />6.SWITCHED MOTION-CONTROLLED ARTIFICIAL LIGHTING SOURCE REQUIRED AT ALL <br />LANDINGS (PHOTO-CONTROLLED AT EXTERIOR LOCATIONS). <br />2022 RESIDENTIAL - CALIFORNIA GREEN BUILDING STANDARDS CODE <br />ELECTRIC VEHICLE CHARGING <br />1.A LISTED RACEWAY TO FACILITATE FUTURE INSTALLATION OF ELECTRIC VEHICLE <br />CHARGER. <br />2.RACEWAY SHALL BE NOT LESS THAN TRADE SIZE 1 (NOMINAL 1-IN. DIAMETER) TO <br />ACCOMMODATE A DEDICATED 208/240-VOLT BRANCH CIRCUIT. <br />3.RACEWAY SHALL ORIGINATE AT THE MAIN SERVICE OR SUBPANEL AND TERMINATE INTO <br />A LISTED CABINET, BOX OR OTHER ENCLOSURE IN CLOSE PROXIMITY TO THE PROPOSED <br />LOCATION OF THE EV CHARGER. <br />4.RACEWAY SHALL BE CONTINUOUS AT ENCLOSED, INACCESSIBLE OR CONCEALED AREAS <br />AND SPACES. <br />5.THE SERVICE PANEL OR SUBPANEL SHALL PROVIDE CAPACITY TO INSTALL A 40-AMPRE <br />MINIMUM DEDICATED BRANCH CIRCUIT AND SPACE(S) RESERVED TO PERMIT <br />INSTALLATION OF A BRANCH CIRCUIT OVERCURRENT PROTECTIVE DEVICE. <br />6.THE SERVICE PANEL OR SUBPANEL CIRCUIT DIRECTORY SHALL IDENTIFY: <br />6.a.THE OVERCURRENT PROTECTIVE DEVICE SPACE(S) FOR FUTURE EV CHARGING AS <br />"EV CAPABLE" <br />6.b.THE RACEWAY TERMINATION LOCATION AS "EV CAPABLE” <br />GENERAL NOTES <br />1.NEW RESIDENTIAL DEVELOPMENTS WITH A LANDSCAPE AREA OVER 500 SQ. FT. SHALL <br />COMPLY WITH ONE OF THE FOLLOWING [CALGREEN 4.304.1]: <br />1.a.1) LOCAL WATER EFFICIENT LANDSCAPE ORDINANCE OR CURRENT CALIFORNIA <br />DEPARTMENT OF WATER RESOURCES' MODEL WATER EFFICIENT LANDSCAPE <br />ORDINANCE (MWELO). <br />1.b.2) LANDSCAPE AREAS LESS THAN 2500 SQ. FT. MAY COMPLY WITH MWELO'S <br />APPENDIX D PRESCRIPTIVE COMPLIANCE OPTION. <br />2.JOINTS AND OPENINGS, ANNULAR SPACES AROUND PIPES, ELECTRIC CABLES, <br />CONDUITS, OR OTHER OPENINGS IN PLATES AT EXTERIOR WALLS SHALL BE PROTECTED <br />AGAINST THE PASSAGE OF RODENTS BY CLOSING SUCH OPENINGS WITH CEMENT <br />MORTAR, CONCRETE MASONRY OR SIMILAR METHOD ACCEPTABLE TO THE ENFORCING <br />AGENCY. [CALGREEN 4.406.1]. <br />3.BEFORE FINAL INSPECTION, A COMPLETE OPERATION AND MAINTENANCE MANUAL <br />SHALL BE PLACED IN THE BUILDING. A SAMPLE OF THE MANUAL IS AVAILABLE ON THE <br />HOUSING AND COMMUNITY DEVELOPMENT (HCD) WEB SITE. THE MANUAL SHOULD <br />INCLUDE THE ITEMS LISTED IN 2022 CALGREEN 4.410.1. <br />4.PAINTS, STAINS, COATINGS, ADHESIVES, SEALANTS AND CAULKS SHALL COMPLY WITH <br />THE VOLATILE ORGANIC COMPOUND (VOC) LIMITS LISTED IN 2022 CALGREEN SECTION <br />4.504.2. <br />5.THE VOC CONTENT VERIFICATION SHALL BE MADE AVAILABLE TO THE CITY STAFF UPON <br />REQUEST. <br />6.ALL NEW AND CARPET CUSHIONS INSTALLED IN THE BUILDING INTERIOR SHALL MEET <br />THE TESTING AND PRODUCT REQUIREMENTS OF ONE OF THE FOLLOWING <br />6.a.1) CARPET AND RUG INSTITUTE'S GREEN LABEL PLUS PROGRAM <br />6.b.2) CALIFORNIA DEPARTMENT OF PUBLIC HEALTH'S SPECIFICATION 01350 <br />6.c.3) NSF/ANSI 140 AT THE GOLD LEVEL <br />6.d.4) SCIENTIFIC CERTIFICATION SYSTEMS INDOOR ADVANTAGETM GOLD <br />7.EIGHTY PERCENT OF THE FLOOR AREA RECEIVING RESILIENT FLOORING SHALL COMPLY <br />WITH ONE OR MORE OF THE FOLLOWING [CALGREEN 4.504.4]: <br />7.a.1) VOC EMISSION LIMITS DEFINED IN THE CHPS HIGH PERFORMANCE PRODUCTS <br />DATABASE <br />7.b.CERTIFIED UNDER UL GREENGUARD GOLD <br />7.c.CERTIFICATION UNDER THE RESILIENT FLOOR COVERING INSTITUTE (RFCI) <br />FLOORSCORE PROGRAM <br />7.d.MEET THE CALIFORNIA DEPARTMENT OF PUBLIC HEALTH'S SPECIFICATION 01350 <br />8.NEW HARDWOOD PLYWOOD, PARTICLE BOARD, AND MEDIUM DENSITY FIBERBOARD <br />(MDF) COMPOSITE WOOD PRODUCT USED IN THE BUILDING SHALL MEET THE <br />FORMALDEHYDE LIMITS LISTED IN 2022 CALGREEN TABLE 4.504.5. <br />9.BUILDING MATERIALS WITH VISIBLE SIGNS OF WATER DAMAGE SHALL NOT BE INSTALLED. <br />WALLS AND FLOORS FRAMING SHALL NOT BE ENCLOSED WHEN FRAMING MEMBERS <br />EXCEED 19% MOISTURE CONTENT. [CALGREEN 4.505.3]. <br />2022 RESIDENTIAL - CALIFORNIA ENERGY CODE <br />LIGHTING <br />1.LIGHTING IN BATHROOMS SHALL HAVE ALL HIGH EFFICACY LUMINAIRE AND AT LEAST <br />ONE LUMINAIRE MUST BE CONTROLLED BY A VACANCY SENSOR. <br />2.ALL THE INSTALLED WATTAGE OF LUMINAIRES IN KITCHENS SHALL BE HIGH EFFICACY <br />AND SHALL HAVE A MANUAL ON/OFF IN ADDITION TO A VACANCY SENSOR OR DIMMER. <br />UNDER CABINET LIGHTING SHALL BE SWITCHED SEPARATELY. <br />3.LIGHTING IN GARAGES, LAUNDRY ROOMS AND UTILITY ROOMS: ALL LUMINAIRES SHALL <br />BE HIGH EFFICACY AND AT LEAST ONE LUMINAIRE IN EACH OF THESE SPACES SHALL BE <br />CONTROLLED BY A VACANCY SENSOR. <br />4.ALL LUMINAIRES SHALL BE HIGH EFFICACY AND SHALL HAVE A MANUAL ON/OFF IN <br />ADDITION TO A VACANCY SENSOR OR DIMMER. <br />5.OUTDOOR LIGHTING: ALL LUMINAIRES MOUNTED TO THE BUILDING OR TO OTHER <br />BUILDINGS ON THE SAME LOT SHALL BE HIGH EFFICACY LUMINAIRES AND MUST BE <br />CONTROLLED BY A MANUAL ON AND OFF SWITCH, AND CONTROLLED BY ONE OF THESE <br />AUTOMATIC CONTROL TYPES: PHOTOCONTROL AND A MOTION SENSOR, OR <br />ASTRONOMICAL TIME CLOCK OR ENERGY MANAGEMENT CONTROL SYSTEM (EMCS). <br />6.PROVIDE AN EXTERIOR LIGHT AT NEW EXTERIOR EXITS. FOR DWELLING UNITS, <br />ATTACHED GARAGES, AND DETACHED GARAGES WITH ELECTRIC POWER, AT LEAST ONE <br />WALL SWITCH-CONTROLLED LIGHTING OUTLET SHALL BE INSTALLED TO PROVIDE <br />ILLUMINATION ON THE EXTERIOR SIDE OF OUTDOOR ENTRANCES OR EXITS WITH GRADE <br />LEVEL ACCESS. A VEHICLE DOOR IN A GARAGE SHALL NOT BE CONSIDERED AS AN <br />OUTDOOR ENTRANCE OR EXIT. EXCEPTION: REMOTE, CENTRAL, OR AUTOMATIC <br />CONTROL OF LIGHTING SHALL BE PERMITTED. <br />2022 RESIDENTIAL - MECHANICAL / PLUMBING <br />MECHANICAL NOTES <br />1.ATTIC/UNDERFLOOR INSTALLATION MUST COMPLY WITH SECTIONS 904, 908, AND 909 OF <br />THE CALIFORNIA MECHANICAL CODE (CMC). <br />2.WHEN A WATER HEATER COMPARTMENT IS OPENABLE TO AND IS ACCESSIBLE FROM A <br />BEDROOM OR BATHROOM, FUEL BURNING WATER HEATERS SHALL BE SEPARATED IN A <br />CLOSET PROTECTED WITH A LISTED, GASKETED SELF-CLOSING DOOR ASSEMBLY <br />INSTALLED WITH A THRESHOLD/BOTTOM SEAL COMPLYING WITH SECTION 504.1.1 AND <br />504.1.2 OF THE CALIFORNIA PLUMBING CODE. COMBUSTION AIR SHALL BE SUPPLIED TO <br />THE CLOSET FROM THE EXTERIOR IN ACCORDANCE WITH SECTION 506.4 OF THE CPC & <br />THE WATER HEATER SHALL BE DIRECT VENTING. THE CLOSET SHALL BE USED <br />EXCLUSIVELY FOR THE WATER HEATER. CPC 504.1 <br />3.WHEN A CENTRAL HEATING FURNACE COMPARTMENT IS OPENABLE TO AND IS <br />ACCESSIBLE FROM A SLEEPING ROOM SUCH AS A BEDROOM OR A BATHROOM THEY <br />SHALL BE SEPARATED FROM BEDROOM IN A CLOSET PROTECTED WITH A LISTED, <br />GASKETED SELF-CLOSING DOOR ASSEMBLY COMPLYING WITH SECTION 904.1.1 AND <br />904.1.2 OF THE CALIFORNIA MECHANICAL CODE. COMBUSTION AIR SHALL BE SUPPLIED <br />TO THE CLOSET FROM THE EXTERIOR IN ACCORDANCE WITH SECTION 506.4 OF THE CPC. <br />THE CLOSET SHALL BE USED EXCLUSIVELY FOR THE FURNACE. THE FURNACE SHALL BE <br />OF THE DIRECT VENT TYPE. CMC 904.1 <br />WATER METER/RESIDENTIAL FIRE SPRINKLER <br />1.WATER METERS FOR COMBINED DOMESTIC WATER AND FIRE SPRINKLER SYSTEMS <br />SHALL NOT BE INSTALLED UNTIL THE FIRE SPRINKLER SYSTEM HAS BEEN SUBMITTED <br />AND APPROVED BY THE BUILDING OFFICIAL. <br />2.AFTER THE BUILDING PERMIT HAS BEEN ISSUED, THE OWNER SHALL BE RESPONSIBLE <br />FOR ANY COSTS INCURRED AS A RESULT OF CHANGES TO THE DESIGN OF THE FIRE <br />SPRINKLER SYSTEM WHICH PRODUCE A HIGHER GPM AND A LARGER METER SIZE <br />REQUIREMENT: <br />OWNER SIGNATURE: ___NOT APPLICABLE___________________ <br />2022 RESIDENTIAL - GENERAL BUILDING / STRUCTURAL <br />GENERAL/ SPECIAL SUBJECTS <br />PROP D/ COASTAL HEIGHT LIMITATION OVERLAY ZONE (IF APPLICABLE TO PROJECT) <br />1.THE HIGHEST POINT OF THE ROOF, EQUIPMENT, OR ANY VENT, PIPE, ANTENNA OR <br />OTHER PROJECTION SHALL NOT EXCEED 30 FEET ABOVE BASE OF MEASUREMENT <br />(REFERENCE DATUM). <br />2.A PRE-CONSTRUCTION INSPECTION IS REQUIRED DUE TO THE HEIGHT OF THE <br />PROPOSED STRUCTURE BEING WITHIN ONE FOOT OF THE MAXIMUM HEIGHT ALLOWED IN <br />THE COASTAL HEIGHT LIMIT OVERLAY ZONE (PROPOSITION D). <br />FAA PART 77 NOTIFICATION (IF APPLICABLE TO PROJECT) <br />1.FAA SELF CERTIFICATION OPTION: <br />THE CITY WILL NOT REQUIRE NOTIFICATION TO THE FAA IF A PROFESSIONAL, LICENSED <br />BY THE STATE OF CALIFORNIA TO PREPARE CONSTRUCTION DOCUMENTS, PROVIDES <br />THE FOLLOWING CERTIFICATION ON THEIR PLANS, ALONG WITH THEIR SIGNATURE AND <br />REGISTRATION STAMP: <br />"I ___________________________DO HEREBY CERTIFY THAT THE STRUCTURE(S) OR <br />MODIFICATION TO EXISTING STRUCTURE(S) SHOWN ON THESE PLANS DO NOT <br />REQUIRE FEDERAL AVIATION ADMINISTRATION NOTIFICATION BECAUSE PER <br />SECTION 77.15 (A) OF TITLE 14 OF THE CODE OF FEDERAL REGULATIONS CFR PART 77, <br />NOTIFICATION IS NOT REQUIRED." <br />2.A PRE-CONSTRUCTION INSPECTION IS REQUIRED DUE TO THE HEIGHT OF THE <br />PROPOSED STRUCTURE IN RELATION TO THE FAA PART 77 NOTIFICATION SURFACE <br />REQUIREMENTS. THE PRE-CONSTRUCTION INSPECTION MUST BE SCHEDULED AND <br />CLEARED BY THE FIELD INSPECTOR BEFORE ANY SUBSEQUENT INSPECTIONS CAN BE <br />SCHEDULED. CALL (858) 581-7111 TO SCHEDULE THE PRE-CONSTRUCTION INSPECTION. <br />CONTACT THE INSPECTION SERVICES OFFICE AT (858) 492-5070, IF YOU HAVE ANY <br />QUESTIONS PERTAINING TO THE PRE-CONSTRUCTION INSPECTION. <br />DEFERRED SUBMITTAL (GENERAL) <br />1.PLANS FOR THE DEFERRED SUBMITTAL ITEMS SHALL BE SUBMITTED IN A TIMELY <br />MANNER BUT NOT LESS THAN 30 BUSINESS DAYS PRIOR TO INSTALLATION FOR CITY <br />REVIEW AND APPROVAL. <br />2.THE DEFERRED SUBMITTAL ITEMS SHALL NOT BE INSTALLED UNTIL THEIR DESIGN AND <br />SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING OFFICIAL. <br />3.THE REGISTERED AND RESPONSIBLE DESIGN PROFESSIONAL SHALL REVIEW THE <br />DEFERRED SUBMITTAL DOCUMENTS AND SUBMIT THEM TO THE BUILDING OFFICIAL, WITH <br />ANNOTATION INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE BEEN <br />REVIEWED AND FOUND TO BE IN GENERAL CONFORMANCE TO THE DESIGN OF THE <br />BUILDING. <br /> DEFERRED SUBMITTAL (NFPA 13D FIRE SPRINKLER) <br />1.THE SUBMITTAL OF RESIDENTIAL FIRE SPRINKLER PLANS REQUIRED BY CALIFORNIA <br />RESIDENTIAL CODE SECTION R313 HAS BEEN DEFERRED. <br />2.TO AVOID DELAYS IN CONSTRUCTION, PLANS FOR FIRE SPRINKLER PLANS SHALL BE <br />SUBMITTED NOT LESS THAN 30 CALENDAR DAYS PRIOR TO INSTALLATION OR PRIOR TO <br />REQUESTING A FOUNDATION INSPECTION. A FRAMING/ROUGH INSPECTION SHALL NOT <br />BE REQUESTED PRIOR TO APPROVAL OF THE FIRE SPRINKLER PLANS. <br />SPECIAL INSPECTIONS (IF APPLICABLE TO PROJECT) <br />1.NOTICE TO THE APPLICANT/OWNER/ OWNER'S AGENT/ARCHITECT OR ENGINEER OF <br />RECORD: BY USING THIS PERMITTED CONSTRUCTION DRAWINGS FOR <br />CONSTRUCTION/INSTALLATION OF THE WORK SPECIFIED HEREIN, YOU AGREE TO <br />COMPLY WITH THE REQUIREMENTS OF THE CITY'S JURISDICTIONS FOR SPECIAL <br />INSPECTIONS, STRUCTURAL OBSERVATIONS, CONSTRUCTION MATERIAL TESTING AND <br />OFF-SITE FABRICATION OF BUILDING COMPONENTS, CONTAINED IN THE STATEMENT OF <br />SPECIAL INSPECTIONS AND, AS REQUIRED BY THE CALIFORNIA CONSTRUCTION CODES. <br />2.NOTICE TO THE CONTRACTOR/BUILDER/INSTALLER/SUB-CONTRACTOR/OWNER-BUILDER: <br />BY USING THIS PERMITTED CONSTRUCTION DRAWINGS FOR <br />CONSTRUCTION/INSTALLATION OF THE WORK SPECIFIED HEREIN, YOU ACKNOWLEDGE <br />AND ARE AWARE OF, THE REQUIREMENTS CONTAINED IN THE STATEMENT OF SPECIAL <br />INSPECTIONS. YOU AGREE TO COMPLY WITH THE REQUIREMENTS OF THE CITY FOR <br />SPECIAL INSPECTIONS, STRUCTURAL OBSERVATIONS, CONSTRUCTION MATERIAL <br />TESTING AND OFF-SITE FABRICATION OF BUILDING COMPONENTS, CONTAINED IN THE <br />STATEMENT OF SPECIAL INSPECTIONS AND, AS REQUIRED BY THE CALIFORNIA <br />CONSTRUCTION CODES. <br />3.THE SPECIAL INSPECTOR MUST BE REGISTERED BY THE CITY'S JURISDICTION, <br />DEVELOPMENT SERVICES, IN THE CATEGORY OF WORK REQUIRED TO HAVE SPECIAL <br />INSPECTION. <br />4.THE SPECIAL INSPECTIONS IDENTIFIED ON PLANS ARE, IN ADDITION TO, AND NOT A <br />SUBSTITUTE FOR, THOSE INSPECTIONS REQUIRED TO BE PERFORMED BY A CITY'S <br />BUILDING INSPECTOR. <br />5.THE CONSTRUCTION MATERIALS TESTING LABORATORY MUST BE APPROVED BY THE <br />CITY'S DEVELOPMENT SERVICES, FOR TESTING OF MATERIALS, SYSTEMS, COMPONENTS <br />AND, EQUIPMENT. <br />6.OFFSITE FABRICATOR MUST BE APPROVED BY THE CITY'S DEVELOPMENT SERVICES FOR <br />THE FABRICATION OF MEMBERS AND ASSEMBLIES ON THE PREMISES OF THE <br />FABRICATOR'S SHOP. <br />7.OFFSITE FABRICATOR SHALL SUBMIT AN 'APPLICATION TO PERFORM OFF-SITE <br />FABRICATION' TO THE INSPECTION SERVICES DIVISION FOR APPROVAL PRIOR TO <br />COMMENCEMENT OF FABRICATION. <br />8.OFFSITE FABRICATOR SHALL SUBMIT A 'CERTIFICATE OF COMPLIANCE FOR OFF-SITE <br />FABRICATION' TO THE INSPECTION SERVICES DIVISION PRIOR TO ERECTION OF <br />FABRICATED ITEMS AND ASSEMBLIES. <br />SOILS AND FOUNDATION <br />1.WHEN NO GEOTECHNICAL INVESTIGATION REPORT IS PROVIDED: <br />THE STRUCTURE(S) WILL BE LOCATED ENTIRELY ON UNDISTURBED NATIVE SOIL. <br />SIGNATURE ___SEE STRUCTURAL_____OWNER/LICENSED ENGINEER OR ARCHITECT <br />2.WHEN NO GEOTECHNICAL INVESTIGATION REPORT IS PROVIDED: <br />AS A CALIFORNIA LICENSED ARCHITECT/ENGINEER, I HAVE CLASSIFIED THE <br />UNDISTURBED NATIVE SOILS TO BE ___________ AND PER TABLE 1806.2 OF THE 2022 CBC <br />I HAVE ASSIGNED A FOUNDATION PRESSURE OF ___________ PSF. FOR THE DESIGN OF <br />FOUNDATIONS RELATED TO THIS PROJECT. <br />SIGNATURE ______SEE STRUCTURAL________OF LICENSED ARCHITECT/ENGINEER <br />3.IF THE BUILDING INSPECTOR SUSPECTS FILL, EXPANSIVE SOILS OR ANY GEOLOGIC <br />INSTABILITY BASED UPON OBSERVATION OF THE FOUNDATION EXCAVATION, A SOILS OR <br />GEOLOGICAL REPORT, AND RESUBMITTAL OF PLANS TO PLAN CHECK TO VERIFY THAT <br />REPORT RECOMMENDATIONS HAVE BEEN INCORPORATED, MAY BE REQUIRED. <br />FIRE NOTES <br />1.DURING CONSTRUCTION, AT LEAST ONE EXTINGUISHER SHALL BE PROVIDED ON EACH <br />FLOOR LEVEL AT EACH STAIRWAY, IN ALL STORAGE AND CONSTRUCTION SHEDS, IN <br />LOCATIONS WHERE FLAMMABLE OR COMBUSTIBLE LIQUIDS ARE STORED OR USED, AND <br />WHERE OTHER SPECIAL HAZARDS ARE PRESENT PER CFC 3315.1. <br />2.BUILDINGS UNDERGOING CONSTRUCTION, ALTERATION, OR DEMOLITION SHALL <br />CONFORM TO CFC CHAPTER 33. WELDING, CUTTING, AND OTHER HOT WORK SHALL BE IN <br />CONFORMANCE WITH CFC CHAPTER 35. <br />CALIFORNIA RESIDENTIAL CODE <br />1.DUCTS IN THE GARAGE AND DUCTS PENETRATING WALLS OR CEILINGS SEPARATING THE <br />DWELLING FROM THE GARAGE SHALL BE CONSTRUCTED OF MINIMUM NO. 26 GAUGE <br />SHEET STEEL OR OTHER APPROVED MATERIAL AND SHALL HAVE NO OPENINGS INTO <br />THE GARAGE. <br />2.SHOWER COMPARTMENTS AND BATHTUBS WITH INSTALLED SHOWER HEADS SHALL BE <br />FINISHED WITH A NONABSORBENT SURFACE THAT EXTENDS TO A HEIGHT OF NOT LESS <br />THAN 6 FEET ABOVE THE FLOOR. <br />3.SMOKE ALARMS AND SMOKE DETECTORS SHALL BE INSTALLED A MINIMUM OF 20 FEET <br />HORIZONTAL DISTANCE FROM A PERMANENTLY INSTALLED COOKING APPLIANCE. <br />4.SMOKE ALARMS SHALL BE INSTALLED NOT LESS THAN A 3-FOOT HORIZONTAL DISTANCE <br />FROM THE DOOR OR OPENING OF A BATHROOM THAT CONTAINS A BATHTUB OR <br />SHOWER UNLESS THIS WOULD PREVENT PLACEMENT OF A SMOKE ALARM REQUIRED BY <br />OTHER SECTIONS OF THE CBC. <br />5.SMOKE ALARMS AND SMOKE DETECTORS SHALL NOT BE INSTALLED WITHIN A 36-INCH <br />HORIZONTAL PATH FROM THE SUPPLY REGISTERS OF A FORCED AIR HEATING OR <br />COOLING SYSTEM AND SHALL BE INSTALLED OUTSIDE OF THE DIRECT AIRFLOW OF <br />THOSE REGISTERS. <br />6.SMOKE ALARMS SHALL BE INTERCONNECTED SO THAT ACTUATION OF ONE ALARM WILL <br />ACTIVATE ALL THE ALARMS WITHIN THE INDIVIDUAL DWELLING UNIT. IN NEW <br />CONSTRUCTION SMOKE ALARMS SHALL RECEIVE THEIR PRIMARY POWER SOURCE FROM <br />THE BUILDING WIRING AND SHALL BE EQUIPPED WITH BATTERY BACKUP AND LOW <br />BATTERY SIGNAL. <br />7.SMOKE ALARMS SHALL COMPLY WITH NFPA 72 AND SHALL BE LISTED IN ACCORDANCE <br />WITH UL 217. <br />8.COMBINATION SMOKE AND CARBON MONOXIDE ALARMS SHALL BE LISTED IN <br />ACCORDANCE WITH UL 217 AND UL 2034. <br />9.SMOKE ALARM SYSTEMS AND COMPONENTS SHALL BE CALIFORNIA STATE FIRE <br />MARSHAL LISTED AND APPROVED IN ACCORDANCE WITH CALIFORNIA CODE OF <br />REGULATIONS, TITLE 19, DIVISION 1 FOR THE PURPOSE FOR WHICH THEY ARE <br />INSTALLED. <br />10.WINDOW OPENING CONTROL DEVICES SERVING EMERGENCY ESCAPE AND RESCUE <br />OPENINGS SHALL COMPLY WITH ASTM F2090. <br />11.ADD NOTE ON PLANS: "WINDOW FALL CONTROL DEVICE SHALL COMPLY WITH ASTM <br />F2090. AT THE EMERGENCY ESCAPE WINDOWS, THE DEVICE AFTER OPERATION SHOULD <br />RELEASE THE CONTROL DEVICE ALLOWING THE WINDOWS TO FULLY OPEN PROVIDING <br />THE CLEAR NET OPENING AREA REQUIRED FOR EMERGENCY ESCAPE WINDOW IN <br />ACCORDANCE WITH CBC <br />PLUMBING/MECHANICAL <br />1.A PLUMBING FIXTURE CERTIFICATION MUST BE COMPLETED AND SIGNED BY EITHER A <br />LICENSED GENERAL CONTRACTOR, A PLUMBING SUBCONTRACTOR, OR THE BUILDING <br />OWNER CERTIFYING THE FLOW RATE OF THE FIXTURES INSTALLED. A COPY OF THE <br />CERTIFICATION CAN BE OBTAINED FROM THE DEVELOPMENT SERVICES DEPARTMENT. <br />2.ALL PLUMBING FIXTURES AND FITTINGS WILL BE WATER CONSERVING AND WILL COMPLY <br />WITH THE 2022 CGBSC <br />3.PER 2022 CGBSC, PLUMBING FIXTURES (WATER CLOSETS AND URINALS) AND FITTINGS <br />(FAUCETS AND SHOWERHEADS) SHALL BE INSTALLED IN ACCORDANCE WITH THE <br />CALIFORNIA PLUMBING CODE (CPC). <br />4.PROVIDE LAVATORY FAUCETS WITH A MAXIMUM FLOW OF 1.2 GALLONS PER MINUTE <br />(GPM). <br />5.PROVIDE KITCHEN FAUCETS WITH A MAXIMUM FLOW OF 1.8 GALLONS PER MINUTE (GPM). <br />6.PROVIDE WATER CLOSETS WITH A MAXIMUM FLOW OF 1.28 GALLONS FLUSH (GPF). <br />7.PROVIDE SHOWER HEADS WITH A MAXIMUM FLOW OF 1.8 GALLONS PER MINUTE (GPM). <br />8.WHEN A SHOWER IS SERVED BY MORE THAN ONE SHOWERHEAD, THE COMBINED FLOW <br />RATE OF ALL SHOWERHEADS AND/OR OTHER SHOWER OUTLETS CONTROLLED BY A <br />SINGLE VALVE SHALL NOT EXCEED 2.0 GALLONS PER MINUTE AT 80 PSI, OR THE SHOWER <br />SHALL BE DESIGNED TO ONLY ALLOW ONE SHOWER OUTLET TO BE IN OPERATION AT A <br />TIME. HANDHELD SHOWERS ARE CONSIDERED SHOWERHEADS. <br />9.PERMANENT VACUUM BREAKERS SHALL BE INCLUDED WITH ALL NEW HOSE BIBBS. <br />10.PLUMBING FIXTURES (WATER CLOSETS AND URINALS) AND FITTINGS (FAUCETS AND <br />SHOWERHEADS) SHALL BE INSTALLED IN ACCORDANCE WITH THE CALIFORNIA <br />PLUMBING CODE (CPC). <br />11.ANY INSTALLED GAS FIREPLACE SHALL BE A DIRECT-VENT SEALED-COMBUSTION TYPE. <br />ANY INSTALLED WOODSTOVE OR PELLET STOVE SHALL COMPLY WITH U.S. EPA PHASE II <br />EMISSION LIMITS WHERE APPLICABLE. WOODSTOVES, PELLET STOVES AND FIREPLACES <br />SHALL ALSO COMPLY WITH APPLICABLE LOCAL ORDINANCES. <br />12.MECHANICAL EXHAUST FANS WHICH EXHAUST DIRECTLY FROM BATHROOMS SHALL <br />COMPLY WITH THE FOLLOWING: <br />12.a.1) FANS SHALL BE ENERGY STAR COMPLIANT AND BE DUCTED TO TERMINATE <br />OUTSIDE THE BUILDING. <br />12.b.2) UNLESS FUNCTIONING AS A COMPONENT OF A WHOLE HOUSE VENTILATION <br />SYSTEM, FANS MUST BE CONTROLLED BY A HUMIDISTAT WHICH SHALL BE READILY <br />ACCESSIBLE. HUMIDISTAT CONTROLS SHALL BE CAPABLE OF ADJUSTMENT <br />BETWEEN A RELATIVE HUMIDITY RANGE OF 50 TO 80 PERCENT. <br />13.HEATING AND AIR CONDITIONERS SHALL BE SIZED, DESIGNED AND HAVE THEIR <br />EQUIPMENT SELECTED USING THE FOLLOWING METHODS: <br />13.a.1. THE HEAT LOSS AND HEAT GAIN IS ESTABLISHED ACCORDING TO ANSI/ACCA 2 <br />MANUAL J - 2004 (RESIDENTIAL LOAD CALCULATION), ASHRAE HANDBOOKS OR <br />OTHER EQUIVALENT DESIGN SOFTWARE OR METHODS. <br />13.b.2. DUCT SYSTEMS ARE SIZED ACCORDING TO ANSI/ACCA 1 MANUAL D - 2009 <br />(RESIDENTIAL DUCT SYSTEMS), ASHRAE HANDBOOKS OR OTHER EQUIVALENT <br />DESIGN SOFTWARE OR METHODS. <br />13.c.3. SELECT HEATING AND COOLING EQUIPMENT ACCORDING TO ANSI/ACCA 3 <br />MANUAL S - 2004 (RESIDENTIAL EQUIPMENT SELECTION). <br />14.ALL DUCT AND OTHER RELATED AIR DISTRIBUTION COMPONENT OPENINGS SHALL BE <br />COVERED DURING WITH TAPE, PLASTIC, OR SHEET METAL UNTIL THE FINAL STARTUP OF <br />THE HEATING COOLING, AND VENTILATION EQUIPMENT. [CALGREEN 4.504.1]. <br />15.NEWLY INSTALLED BATHROOM EXHAUST FANS SHALL BE ENERGY STAR COMPLIANT AND <br />BE DUCTED TO TERMINATE OUTSIDE OF THE BUILDING. UNLESS FUNCTIONING AS A <br />COMPONENT OF A WHOLE HOUSE VENTILATION SYSTEM, FANS MUST BE CONTROLLED <br />BY A HUMIDISTAT WHICH CAN ADJUST BETWEEN 50 TO 80 PERCENT. [CALGREEN 4.506.1]. <br />OUTDOOR SHOWERS <br />1.OUTDOOR SHOWER DRAINS AND SINKS ARE NOT PERMITTED TO CONNECT TO THE <br />PUBLIC SEWER SYSTEM UNLESS EQUIPPED WITH AN APPROVED COVER. COLD WATER <br />CONNECTION ONLY. <br />2.STORM/RAINWATER IS NOT PERMITTED IN THE PUBLIC SEWER CONVEYANCE SYSTEM <br />2022 RESIDENTIAL - VERY HIGH FIRE HAZARD ZONE SEVERITY ZONE <br />1.ROOF GUTTERS SHALL BE PROVIDED WITH THE MEANS TO PREVENT THE <br />ACCUMULATION OF LEAVES AND DEBRIS IN THE GUTTER. ALL ROOF GUTTERS AND <br />DOWNSPOUTS SHALL BE CONSTRUCTED OF NON-COMBUSTIBLE MATERIALS. <br />2.DRIP EDGE FLASHING USED AT THE FREE EDGES OF ROOFING MATERIALS SHALL BE <br />NON-COMBUSTIBLE. <br />3.VALLEY FLASHINGS SHALL BE NOT LESS THAN 0.019-INCH (NO. 26 GALVANIZED SHEET <br />GAGE) CORROSION-RESISTANT METAL INSTALLED OVER A MINIMUM 36-INCH-WIDE <br />UNDERLAYMENT CONSISTING OF ONE LAYER OF NO. 72 ASTM CAP SHEET RUNNING THE <br />FULL LENGTH OF THE VALLEY. <br />4.CHIMNEYS, FLUES OR STOVEPIPES ATTACHED TO ANY FIREPLACE, STOVE, BARBEQUE <br />OR OTHER SOLID OR LIQUID FUEL BURNING EQUIPMENT OR DEVICE SHALL BE EQUIPPED <br />WITH AN APPROVES SPARK ARRESTOR. <br />5.TURBINE ATTIC VENTS SHALL BE EQUIPPED TO ALLOW ONE-WAY DIRECTION ROTATION <br />ONLY AND SHALL NOT FREE SPIN IN BOTH DIRECTIONS. <br />6.GLAZING FRAMES MADE OF VINYL MATERIALS SHALL HAVE WELDED CORNERS, METAL <br />REINFORCEMENT IN THE INTERLOCK AREA, AND BE CERTIFIED TO THE MOST CURRENT <br />EDITION OF ANSI/AAMA/NWWDA 101/I.S.2 STRUCTURAL REQUIREMENTS. <br />1.REINFORCEMENT FOR GRAB BARS <br />1.1.AT LEAST ONE BATHROOM ON THE ENTRY LEVEL SHALL BE PROVIDED WITH <br />REINFORCEMENT INSTALLED IN ACCORDANCE WITH THIS SECTION. WHERE <br />THERE IS NO BATHROOM ON THE ENTRY LEVEL, AT LEAST ONE BATHROOM ON <br />THE SECOND OR THIRD FLOOR OF THE DWELLING SHALL COMPLY WITH THIS <br />SECTION. <br />1.2.PROVIDE 2X8 MINIMUM BLOCKING BETWEEN 32" AND 39-1/4" INCHES ABOVE THE <br />FINISHED FLOOR FLUSH WITH THE WALL FRAMING. <br />1.3.WATER CLOSET REINFORCEMENT SHALL BE INSTALLED ON BOTH SIDE WALLS OF <br />THE FIXTURE, OR ONE SIDE WALL AND THE BACK WALL. <br />1.4.SHOWER REINFORCEMENT SHALL BE CONTINUOUS WHERE WALL FRAMING IS <br />PROVIDED. <br />1.5.BATHTUB AND COMBINATION BATHTUB/SHOWER REINFORCEMENT SHALL BE <br />CONTINUOUS ON EACH END OF THE BATHTUB AND THE BACK WALL. <br />ADDITIONALLY, BACK WALL REINFORCEMENT FOR A LOWER GRAB BAR SHALL BE <br />PROVIDED WITH THE BOTTOM EDGE LOCATED NO MORE THAN 6" ABOVE THE <br />BATHTUB RIM. <br />2.EXCEPTIONS TO PROVIDING REINFORCED FRAMING <br />2.1.PROVIDE 2X8 BLOCKING IN FLOOR FRAMING FOR FLOOR-MOUNTED, FOLDAWAY <br />OR SIMILAR ALTERNATE GRAB BAR REINFORCEMENTS <br />2.2.PRE-FABRICATED SHOWER ENCLOSURES AND BATHTUB WALL PANELS WITH <br />INTEGRAL FACTORY- INSTALLED GRAB BARS OR WHEN FACTORY-INSTALLED <br />REINFORCEMENT FOR GRAB BARS IS PROVIDED. <br />2.3.REINFORCEMENT OF FLOORS SHALL NOT BE REQUIRED FOR BATHTUBS AND <br />WATER CLOSETS INSTALLED ON CONCRETE SLAB FLOORS. <br />3.ELECTRICAL RECEPTACLE OUTLET, SWITCH AND CONTROL HEIGHTS <br />3.1.ELECTRICAL RECEPTACLE OUTLETS, SWITCHES AND CONTROLS (INCLUDING <br />CONTROLS FOR HEATING, VENTILATION AND AIR CONDITIONING) INTENDED TO BE <br />USED BY OCCUPANTS SHALL BE LOCATED NO MORE THAN 48" MEASURED FROM <br />THE TOP OF THE OUTLET BOX AND NOT LESS THAN 15" MEASURED FROM THE <br />BOTTOM OF THE OUTLET BOX ABOVE THE FINISH FLOOR. <br />4.INTERIOR DOORS <br />4.1.AT LEAST ONE BATHROOM AND ONE BEDROOM ON THE ENTRY LEVEL SHALL <br />PROVIDE A DOORWAY WITH A NET CLEAR OPENING OF NOT LESS THAN 32" <br />MEASURED WITH THE DOOR POSITIONED AT AN ANGLE OF 90 DEGREES FROM <br />THE CLOSED POSITION; OR, IN THE CASE OF A TWO- OR THREE-STORY SINGLE <br />FAMILY DWELLING, ON THE SECOND OR THIRD FLOOR OF THE DWELLING IF A <br />BATHROOM OR BEDROOM IS NOT LOCATED ON THE ENTRY LEVEL. <br />5.DOORBELL BUTTONS <br />5.1.DOORBELL BUTTONS OR CONTROLS SHALL NOT EXCEED 48" ABOVE EXTERIOR <br />FLOOR OR LANDING, MEASURED FROM THE TOP OF THE DOORBELL BUTTON <br />ASSEMBLY. <br />1.GLAZING IN DOORS: <br />1.1.GLAZING IN ALL FIXED AND OPERABLE PANELS OF SWINGING, SLIDING, AND BI-FOLD <br />DOORS SHALL BE CONSIDERED A HAZARDOUS LOCATION <br />1.2.EXCEPTIONS: <br />1.2.1.GLAZED OPENINGS OF A SIZE THROUGH WHICH A 3" Ø SPHERE IS UNABLE TO <br />PASS <br />1.2.2.DECORATIVE GLAZING <br />2.GLAZING ADJACENT DOORS: <br />2.1.GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE PANEL ADJACENT TO A DOOR SHALL <br />BE CONSIDERED TO BE HAZARDOUS LOCATION WHERE THE BOTTOM EDGE OF THE <br />GLAZING IS LESS THAN 60" ABOVE THE FLOOR AND MEETS EITHER OF THE FOLLOWING <br />CONDITIONS: <br />2.1.1.WHERE GLAZING IS WITHIN 24" OF EITHER SIDE OF THE DOOR IN A CLOSED <br />POSITION <br />2.1.2.WHERE THE GLAZING IS PERPENDICULAR TO THE PLANE OF THE DOOR IN A <br />CLOSED POSITION AND WITHIN 24" OF THE HINGE SIDE OF AN IN-SWINGING DOOR <br />2.1.3.EXCEPTIONS: <br />2.1.3.1.DECORATIVE GLAZING <br />2.1.3.2.WHEN THERE IS AN INTERVENING WALL OR OTHER PERMANENT BARRIER <br />BETWEEN THE DOOR AND GLAZING <br />2.1.3.3.WHERE ACCESS THROUGH THE DOOR IS TO A CLOSET OR STORAGE AREA 3' <br />OR LESS IN DEPTH. GLAZING HERE SHALL COMPLY WITH NOTE #3 BELOW <br />2.1.3.4.GLAZING THAT IS ADJACENT TO THE FIXED PANEL OF PATIO DOORS <br />3.GLAZING IN WINDOWS: <br />3.1.GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE PANEL THAT MEETS ALL OF THE <br />FOLLOWING CONDITIONS: <br />3.1.1.THE EXPOSED AREA OF AN INDIVIDUAL PANE IS LARGER THAN 9 SQUARE FEET <br />3.1.2.THE BOTTOM EDGE OF GLAZING IS LESS THAN 18" ABOVE THE FLOOR <br />3.1.3.THE TOP EDGE OF THE GLAZING IS MORE THAN 36" ABOVE THE FLOOR <br />3.1.4.ONE OR MORE WALKING SURFACES ARE WITHIN 36", MEASURED HORIZONTALLY <br />AND IN A STRAIGHT LINE, OF THE GLAZING <br />3.1.5.EXCEPTIONS: <br />3.1.5.1.DECORATIVE GLAZING <br />3.1.5.2.WHERE A HORIZONTAL RAIL IS INSTALLED 34" TO 38" <br />4.GLAZING AND WET SURFACES: <br />4.1.GLAZING IN WALLS, ENCLOSURES OR FENCES, CONTAINING OR FACING HOT TUBS, <br />SPAS, WHIRLPOOLS, SAUNAS, STEAM ROOMS, BATHTUBS, INDOOR AND OUTDOOR <br />SWIMMING POOLS WHERE THE BOTTOM OF THE GLAZING IS LESS THAN 60" MEASURED <br />VERTICALLY ABOVE ANY STANDING OR WALKING SURFACE. THIS SHALL APPLY TO <br />SINGLE GLAZING AND EACH PANE IN MULTIPLE GLAZING <br />4.2.EXCEPTION: <br />4.2.1.GLAZING THAT IS MORE THAN 60" MEASURED HORIZONTALLY, FROM THE WATER’S <br />EDGE OF A BATHTUB, HOT TUB, WHIRLPOOL, SWIMMING POOL, SHOWER, SAUNA, <br />OR STEAM ROOM <br />5.GLAZING ADJACENT TO STAIRS AND RAMPS: <br />5.1.GLAZING WHERE THE BOTTOM EXPOSED EDGE OF THE GLAZING IS LESS THAN 36" <br />ABOVE THE PLANE OF THE ADJACENT WALKING SURFACE OF STAIRWAYS, LANDING <br />BETWEEN FLIGHTS OF STAIRS AND RAMPS <br />5.2.EXCEPTIONS: <br />5.2.1.WHERE GLAZING IS ADJACENT TO A WALING SURFACE AND A HORIZONTAL RAIL IS <br />INSTALLED AT 34" TO 38" ABOVE THE WALKING SURFACE <br />5.2.2.GLAZING 36" OR MORE MEASURED HORIZONTALLY FROM THE WALKING SURFACE <br />6.GLAZING ADJACENT TO BOTTOM STAIR LANDING: <br />6.1.GLAZING ADJACENT TO THE LANDING AT THE BOTTOM OF A STAIRWAYS WITHIN 60" <br />HORIZONTALLY OF THE BOTTOM TREAD OF A STAIRWAY IN ANY DIRECTION WHEN THE <br />EXPOSED SURFACE OF THE GLAZING IS LESS THAN 36" ABOVE THE LANDING <br />AGING-IN-PLACE & FALL PREVENTION <br />SAFETY GLAZING <br />LANDINGS <br />FIRE SEPARATION AND PREVENTION <br />HOLD - 1223 N Ross <br />St3/4/2025