My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
HOLD- 829 N Garfield St - Plan
PBA
>
Building
>
ProjectDox
>
G
>
Garfield St
>
829 N Garfield St
>
HOLD- 829 N Garfield St - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/1/2025 12:11:36 PM
Creation date
6/1/2025 12:11:15 PM
Metadata
Fields
Template:
Plan
Permit Number
20583473
20583704
30547537
40539325
105120166
Full Address
829 N Garfield St
829 N Garfield St Unit# 1
Permit Number (Not in SAPIN)
20583408
20583409
20583410
20583411
20583412
20583413
20583414
20583416
20583417
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
93
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
(EXTG) 50-MIN. SAWN WOOD FLR./CLG. <br />SCALE: 1 1/2" = 1'-0" <br />16" O.C. MAX <br />(E) TONGUE & GROOVE 3/4" x 5.5" <br />STRUCT'L DIAPHRAGM <br /> (E) 2x12 WOOD JOISTS AT 16" O.C. <br />(E) 5/8" GYPSUM PLASTER <br />(E) 3/8" GYPSUM LATH <br />LOAD-BEARING <br />CONTRACTOR SHALL READ AND BE FAMILIAR WITH TEST REPORT AND RELATED SOUND <br />AND FIRE TEST REPORTS LISTED PRIOR TO ASSEMBLY INSTALLATION. <br />STC RATING: <br />- <br />STC TEST NUMBER: <br />- <br />FIRE RATING: <br />50 MIN. <br />EXISTING ASSEMBLY AS OBSERVED: <br />FLOOR: WOOD FINISH FLOORING O/ 3/4" THICK T&G FLOOR DIAPHRAGM O/ 2" X 10" <br />WOOD JOISTS; 16" O.C. <br />CEILING: 5/8" GYPSUM PLASTER O/ 3/8" GYPSUM LATH. <br />EXISTING CBC TIME ASSIGNMENT FROM INTERIOR SIDE: <br />WOOD FLOOR; 16 INCHES O.C.10 MINUTES <br />5/8" GYP. PLASTER O/ 3/8" GYP. LATH [CBC TABLE 722.2.1.4(2)]40 MINUTES <br />TOTAL 50 MINUTES <br />FIRE TEST NUMBER: <br />C.B.C. TABLE 722.2.1.4(2) <br />C.B.C. TABLE 722.6.2(2) <br />(PPSD) 1-HR SAWN WOOD FLR./CLG. <br />SCALE: 1 1/2" = 1'-0" <br />OPTIONAL VARIATIONS AS FOLLOWS: <br />CONTRACTOR SHALL READ AND BE FAMILIAR WITH TEST REPORT AND RELATED SOUND <br />AND FIRE TEST REPORTS LISTED PRIOR TO ASSEMBLY INSTALLATION. <br />STC / IIC RATING: <br />- <br />STC / IIC TEST NUMBER: <br />. <br />. <br />FIRE RATING: <br />1HR <br />FIRE TEST NUMBER: <br />CBC TABLE 721.1 (3): <br />ITEM NUMBER: 13-1.2 <br />16" O.C. MAX <br />CBC 721.1(3) ITEM 13-1.2: <br />DOUBLE WOOD STRUCTURAL PANELS: MINIMUM OF 15/32" WOOD STRUCTURAL PANELS <br />WITH EXTERIOR GLUE AND A MINIMUM OF 19/32" WOOD STRUCTURAL PANEL OR A <br />LAYER OF TYPE I GRADE M-1 PARTICLE BOARD NOT LESS THAN 5/8" THICK. WOOD <br />JOISTS SPACED AT A MAXIMUM OF 16" O.C. <br />(E) T&G STRUCT'L DIAPHRAGM IN LIEU OF 19/32" WOOD STRUCTURAL PANEL. <br />GYPSUM PLASTER: <br />CEMENT OR GYPSUM PLASTER ON METAL LATH. LATH FASTENED WITH 1-1/2" BY NO.11 <br />GAGE BY 7/16" HEAD BARBED SHANK ROOFING NAILS SPACED AT 5" O.C. PLASTER <br />MIXED 1:2 FOR SCRATCH AND 1:3 FOR BROWN COAT, BY WEIGHT, CEMENT TO SAND <br />AGGREGATE. MINIMUM OVERALL THICKNESS OF 5/8". <br />ADDED TO ASSEMBLY: <br />ABOVE: FINISH FLOORING <br />(2) LAYERS OF PLYWOOD SHEATHING <br />REFER TO STRUCTURAL <br />FINISH FLOORING <br />2x WOOD JOISTS AT 16" O.C. <br />REFER TO STRUCTURAL <br />MIN. 5/8" GYPSUM PLASTER <br />ASSEMBLY OVER METAL LATH <br />1 <br />H <br />O <br />U <br />R <br /> <br />A <br />S <br />S <br />E <br />M <br />B <br />L <br />Y <br />W2e(EXTG) 1-HR INTERIOR WOOD STUD <br />SCALE: 1 1/2" = 1'-0" <br />LOAD-BEARING <br />OPTIONAL VARIATIONS AS FOLLOWS: <br />CONTRACTOR SHALL READ AND BE FAMILIAR WITH TEST REPORT AND RELATED SOUND <br />AND FIRE TEST REPORTS LISTED PRIOR TO ASSEMBLY INSTALLATION. <br />FIRE RATING: <br />1HR <br />PLYWOOD SHEATHING WHERE OCCURS <br />REFER TO STRUCTURAL DRAWINGS <br />5/8" TYPE X GYPSUM BOARD <br />16" O.C. MAX <br />WHERE EXISTING WALLS ARE REPLACED WITH NEW WALLS, <br />RESILIENT CHANNELS SHALL BE ADDED TO THIS ASSEMBLY <br />PER GA FILE NO. WP 3243 TO ACHIEVE A MIN. STC RTG. OF 50. <br />W2A <br />(PPSD) 1-HR INTERIOR WOOD STUD <br />SCALE: 1 1/2" = 1'-0" <br />STC RATING - NOT REQUIRED: <br />CBC TABLE 721.1(2) - 14-1.3: <br />EACH INTERIOR SIDE: ONE LAYER 5/8" TYPE X GYPSUM WALLBOARD APPLIED <br />VERTICALLY OR HORIZONTALLY NAILED WITH 6d COOLER OR WALLBOARD NAILS <br />AT 7" O.C. WITH END JOINTS ON NAILING MEMBERS. STAGGER JOINTS EACH SIDE. <br />CBC TABLE 722.6.2(5): <br />GLASS FIBER MINERAL WOOL BATT INSULATION ADDED TO ASSEMBLY. SPACES <br />BETWEEN THE STUDS SHALL BE COMPLETELY FILLED WITH GLASS FIBER MINERAL <br />WOOL BATT INSULATION WEIGHING NOT LESS THAN 2 POUNDS PER CUBIC FOOT. <br />FIRE-RESISTANCE RATING OF 15 MINUTES TIME ASSIGNED FOR ADDITIONAL <br />PROTECTION, PER TABLE 722.6.2(5). <br />(PPSD) CBC TIME ASSIGNMENT FROM INTERIOR SIDE: <br />WOOD STUDS 16 INCHES O.C.20 MINUTES <br />STUD CAVITIES COMPLETELY FILLED W/ GLASS 15 MINUTES <br />FIBER MINERAL WOOD BATT INSULATION <br />5/8" TYPE X GYPSUM BOARD 40 MINUTES <br />TOTAL (NOT MORE THAN 1-HR, PER CBC 722.6.1.1)60 MINUTES <br />WOOD STRUCTURAL PANELS SHALL BE PERMITTED TO BE INSTALLED BETWEEN THE <br />FIRE PROTECTION AND THE WOOD STUDS ON EITHER THE INTERIOR OR EXTERIOR SIDE <br />OF THE WOOD FRAME ASSEMBLIES IN CBC TABLE 721.1(2), PROVIDED THE LENGTH OF <br />THE FASTENERS USED TO ATTACH THE FIRE PROTECTION IS INCREASED BY AN <br />AMOUNT AT LEAST EQUAL TO THE THICKNESS OF THE WOOD STRUCTURAL PANEL. <br />FIRE TEST NUMBER: <br />C.B.C. TABLE 721.1(2) - ITEM: 14-1.3 <br />C.B.C. TABLE 722.6.2(5) <br />LOAD-BEARING <br />CONTRACTOR SHALL READ AND BE FAMILIAR WITH TEST REPORT AND RELATED SOUND <br />AND FIRE TEST REPORTS LISTED PRIOR TO ASSEMBLY INSTALLATION. <br />STC RATING: <br />- <br />STC TEST NUMBER: <br />- <br />FIRE RATING: <br />1HR <br />EXISTING ASSEMBLY: AS OBSERVED AT 829 N. GARFIELD ST, SANTA ANA, CA 92701: <br />2" X 4" STUD WALL; 16" O.C.; 5/8" GYPSUM PLASTER O/ 3/8" GYPSUM LATH ON BOTH <br />SIDES OF WALL. EXISTING CONDITION AT LOCATIONS OBSERVED INCLUDES 1/8" OF <br />GYPSUM PLASTER ON BOTH SIDES OF WALL IN ADDITION TO SIMILAR TESTED <br />ASSEMBLIES BELOW. <br />SIMILAR ASSEMBLY 1: CEBC RESOURCE A TABLE 1.3.2 ITEM CODES W-5-W-89: <br />2" X 4" STUD WALL; 16" O.C.; 1/2" OF 1:2; 1:2 GYPSUM PLASTER O/ 3/8" GYPSUM LATH ON <br />BOTH SIDES OF WALL. RATED FOR 1-HR FIRE-RESISTANCE. <br />SIMILAR ASSEMBLY 2: CBC TABLE 721.1(2) - 12-1.3: <br />2" X 4" STUD WALL; 16" O.C.; 3/8" PERFORATED OR PLAIN GYPSUM LATH AND 1/2" <br />GYPSUM PLASTER EACH SIDE. LATH NAILED WITH 1-1/8" BY NO. 13 GAGE BY 19/64" HEAD <br />PLASTERBOARD BLUE NAILS, 4" ON CENTER. PLASTER MIXED 1:2 BY WEIGHT, GYPSUM <br />TO SAND AGGREGATE. <br />FIRE TEST NUMBER: <br />C.E.B.C. RES.A TABLE 1.3.2 ITEM W-5-W-89 <br />C.B.C. TABLE 721.1(2) ITEM 12-1.3 <br />(E) STRUCT'L CROSS BRACING, <br />WHERE OCCURS <br />(E) 5/8" GYPSUM PLASTER <br />(E) 5/8" GYPSUM PLASTER <br />(E) 2x4 WOOD STUDS <br />AT 16" O.C. <br />(E) 3/8" GYPSUM LATH <br />16" O.C. <br />(E) 3/8" GYPSUM LATH <br />STC RATING - REQUIRED: <br />GA FILE NO. WP 3243: <br />RESILIENT CHANNELS 24" O.C. ATTACHED AT RIGHT ANGLES TO ONE SIDE OF 2x4 WOOD <br />STUDS 24" O.C. WITH 1-1/4" TYPE S DRYWALL SCREWS. ONE LAYER 5/8" TYPE X GYPSUM <br />WALLBOARD OR GYPSUM VENEER BASE APPLIED AT RIGHT ANGLES TO CHANNELS <br />WITH 1" TYPE S DRYWALL SCREWS 8" O.C. WITH VERTICAL JOINTS LOCATED MIDWAY <br />BETWEEN STUDS. 3" MINERAL OR GLASS FIBER INSULATION IN STUD SPACE. <br />(GREATER STUD SIZES (DEPTH) SHALL BE PERMITTED). <br />OPPOSITE SIDE: ONE LAYER 5/8" TYPE X GYPSUM WALLBOARD OR GYPSUM VENEER <br />BASE APPLIED AT PARALLEL OR RIGHT ANGLES TO STUDS WITH 6d CEMENT COATED <br />NAILS, 1-7/8" LONG, 0.0915" SHANK, 15/64" HEADS, 7" O.C. <br />VERTICAL JOINTS STAGGERED 24" O.C. ON OPPOSITE SIDES. (LOAD BEARING) <br />DO NOT INSTALL R.C. OVER PLYWOOD SHEATHING. <br />STC RATING: <br />50 - 54 <br />STC TEST NUMBER: <br />GA FILE NO.: <br />WP 3243 <br />FILL STUD CAVITY DEPTH WITH <br />GLASS FIBER INSULATION <br />5/8" TYPE X GYPSUM BOARD <br />2x4 WOOD STUDS AT 16" O.C. MAX <br />RESILIENT CHANNELS AT 24" O.C. <br />WHERE REQ. SEE VARIATION 'W2A' BELOW. <br />W2 <br />5/8" TYPE X GYPSUM BOARD <br />2x4 WOOD STUDS AT 16" O.C. <br />(EXTG) 1-HR EXTERIOR WOOD STUD <br />SCALE: 1 1/2" = 1'-0" <br />LOAD-BEARING <br />OPTIONAL VARIATIONS AS FOLLOWS: <br />CONTRACTOR SHALL READ AND BE FAMILIAR WITH TEST REPORT AND RELATED SOUND <br />AND FIRE TEST REPORTS LISTED PRIOR TO ASSEMBLY INSTALLATION. <br />STC RATING: <br />- <br />STC TEST NUMBER: <br />- <br />FIRE RATING: <br />1HR <br />16" O.C. MAX <br />(PPSD) 1-HR EXTERIOR WOOD STUD <br />SCALE: 1 1/2" = 1'-0" <br />CBC TABLE 721.1(2) - 15-1.3: <br />EXTERIOR SIDE: 2x4 WOOD STUD WALL 16" O.C. WITH 7/8" CEMENT PLASTER <br />(MEASURED FROM THE FACE OF STUDS) ON THE EXTERIOR SURFACE. PLASTER MIX 1:4 <br />FOR SCRATCH COAT AND 1:5 FOR BROWN COAT, BY VOLUME, CEMENT TO SAND. <br />(GREATER STUD SIZES (DEPTH) SHALL BE PERMITTED). <br />CBC TABLE 721.1(2) - 14-1.3: <br />INTERIOR SIDE: ONE LAYER 5/8" TYPE X GYPSUM WALLBOARD APPLIED VERTICALLY OR <br />HORIZONTALLY NAILED WITH 6d COOLER OR WALLBOARD NAILS AT 7" O.C. WITH END <br />JOINTS ON NAILING MEMBERS. STAGGER JOINTS EACH SIDE. <br />CBC TABLE 722.6.2(5): <br />GLASS FIBER MINERAL WOOL BATT INSULATION ADDED TO ASSEMBLY. SPACES <br />BETWEEN THE STUDS SHALL BE COMPLETELY FILLED WITH GLASS FIBER MINERAL <br />WOOL BATT INSULATION WEIGHING NOT LESS THAN 2 POUNDS PER CUBIC FOOT. <br />FIRE-RESISTANCE RATING OF 15 MINUTES TIME ASSIGNED FOR ADDITIONAL <br />PROTECTION, PER TABLE 722.6.2(5). <br />(PPSD) CBC TIME ASSIGNMENT FROM INTERIOR SIDE: <br />WOOD STUDS 16 INCHES O.C.20 MINUTES <br />STUD CAVITIES COMPLETELY FILLED W/ GLASS 15 MINUTES <br />FIBER MINERAL WOOD BATT INSULATION <br />5/8" TYPE X GYPSUM BOARD 40 MINUTES <br />TOTAL (NOT MORE THAN 1-HR, PER CBC 722.6.1.1)60 MINUTES <br />WOOD STRUCTURAL PANELS SHALL BE PERMITTED TO BE INSTALLED BETWEEN THE <br />FIRE PROTECTION AND THE WOOD STUDS ON EITHER THE INTERIOR OR EXTERIOR SIDE <br />OF THE WOOD FRAME ASSEMBLIES IN CBC TABLE 721.1(2), PROVIDED THE LENGTH OF <br />THE FASTENERS USED TO ATTACH THE FIRE PROTECTION IS INCREASED BY AN <br />AMOUNT AT LEAST EQUAL TO THE THICKNESS OF THE WOOD STRUCTURAL PANEL. <br />FIRE TEST NUMBER: <br />C.B.C. TABLE 721.1(2) - ITEMS: 14-1.3 & 15-1.3 <br />C.B.C. TABLE 722.6.2(5) <br />FILL STUD CAVITY DEPTH WITH GLASS FIBER INSULATION. <br />REFER TO TM00 - TM01 OF MECH. DWGS. <br />LOAD-BEARING <br />CONTRACTOR SHALL READ AND BE FAMILIAR WITH TEST REPORT AND RELATED SOUND <br />AND FIRE TEST REPORTS LISTED PRIOR TO ASSEMBLY INSTALLATION. <br />STC RATING: <br />- <br />STC TEST NUMBER: <br />- <br />FIRE RATING: <br />1HR <br />EXISTING ASSEMBLY: AS OBSERVED AT 829 N. GARFIELD ST, SANTA ANA, CA 92701: <br />STRUCTURE: 2" X 4" STUD WALL; 16" O.C. <br />INTERIOR SIDE: 5/8" GYPSUM PLASTER O/ 3/8" GYPSUM LATH. EXISTING CONDITION AT <br />LOCATIONS OBSERVED INCLUDES 1/8" OF GYPSUM PLASTER IN ADDITION TO SIMILAR <br />TESTED ASSEMBLIES IN DETAIL W2e / - . <br />EXTERIOR SIDE: EXTERIOR CEMENT PLASTER (STUCCO) FINISH, THICKNESS OF <br />ASSEMBLY UNKNOWN. <br />(E) CBC TIME ASSIGNMENT FROM INTERIOR SIDE: <br />WOOD STUDS 16 INCHES O.C.20 MINUTES <br />5/8" GYP. PLASTER O/ 3/8" GYP. LATH [CBC TABLE 722.2.1.4(2)]40 MINUTES <br />TOTAL 60 MINUTES <br />(E) STRUCT'L CROSS BRACING, <br />WHERE OCCURS <br />(E) 5/8" GYPSUM PLASTER <br />(E) 2x4 WOOD STUDS <br />AT 16" O.C. <br />(E) 3/8" GYPSUM LATH <br />16" O.C. <br />7/8" THICK 3 COAT EXTERIOR CEMENT PLASTER <br />ASSEMBLY OVER SELF-FURRING EXTERIOR METAL LATH <br />OVER WEATHER RESISTIVE BARRIER <br />PLYWOOD SHEATHING; WHERE OCCURS <br />REFER TO STRUCTURAL DRAWINGS <br /> (E) EXTERIOR CEMENT PLASTER ASSEMBLY <br />OVER WEATHER RESISTIVE BARRIER <br />FIRE TEST NUMBER: <br />C.E.B.C. RES.A TABLE 1.3.2 ITEM W-5-W-89 <br />C.B.C. TABLE 721.1(2) ITEM 12-1.3 <br />W1e <br />W1 <br />FCe <br />FC1 <br />FC2(PPSD) 1-HR SAWN WOOD FLR./CLG. <br />SCALE: 1 1/2" = 1'-0" <br />OPTIONAL VARIATIONS AS FOLLOWS: <br />CONTRACTOR SHALL READ AND BE FAMILIAR WITH TEST REPORT AND RELATED SOUND <br />AND FIRE TEST REPORTS LISTED PRIOR TO ASSEMBLY INSTALLATION. <br />STC / IIC RATING: <br />- <br />STC / IIC TEST NUMBER: <br />- <br />FIRE RATING: <br />1HR <br />FIRE TEST NUMBER: <br />CBC TABLE 722.6.2 (1, 2, 4 & 5) <br />. <br />CBC TABLE 722.6.2(4): <br />FLOOR: RESILIENT FLOORING O/ 1/2" PLYWOOD OR 3/4" THICK T&G SOFTWOOD <br />CBC TABLE 722.6.2(2): <br />WOOD FRAME: 2" X 12" WOOD JOISTS; 16" O.C. <br />CBC TABLE 722.6.2(1): <br />WALLBOARD MEMBRANE AT CEILING: 5/8" TYPE 'X' GYPSUM BOARD <br />CBC TABLE 722.6.2(5): <br />ADDITIONAL PROTECTION: GLASS FIBER MINERAL WOOL BATT INSULATION ADDED TO <br />ASSEMBLY. SPACES BETWEEN THE STUDS SHALL BE COMPLETELY FILLED WITH GLASS <br />FIBER MINERAL WOOL BATT INSULATION WEIGHING NOT LESS THAN 2 POUNDS PER <br />CUBIC FOOT. FIRE-RESISTANCE RATING OF 15 MINUTES TIME ASSIGNED FOR <br />ADDITIONAL PROTECTION, PER TABLE 722.6.2(5). <br />ADDED TO ASSEMBLY: <br />ABOVE: FINISH FLOORING <br />(PPSD) CBC TIME ASSIGNMENT FROM CEILING SIDE: <br />WOOD FLOOR; 16 INCHES O.C.10 MINUTES <br />STUD CAVITIES COMPLETELY FILLED W/ GLASS 15 MINUTES <br />FIBER MINERAL WOOD BATT INSULATION <br />5/8" TYPE X GYPSUM BOARD 40 MINUTES <br />TOTAL (NOT MORE THAN 1-HR, PER CBC 722.6.1.1)60 MINUTES <br />FINISH FLOORING <br />MIN. 1/2" PLYWOOD SHEATHING <br />REFER TO STRUCTURAL <br />2x WOOD JOISTS AT 16" O.C. <br />REFER TO STRUCTURAL <br />5/8" TYPE X GYPSUM BOARD <br />1 <br />H <br />O <br />U <br />R <br /> <br />A <br />S <br />S <br />E <br />M <br />B <br />L <br />Y <br />STUD CAVITIES COMPLETELY FILLED W/ <br />GLASS FIBER MINERAL WOOD BATT INSULATION <br />16" O.C. MAX <br />(PPSD) 1-HR SAWN WOOD FLR./CLG. <br />SCALE: 1 1/2" = 1'-0" <br />OPTIONAL VARIATIONS AS FOLLOWS: <br />CONTRACTOR SHALL READ AND BE FAMILIAR WITH TEST REPORT AND RELATED SOUND <br />AND FIRE TEST REPORTS LISTED PRIOR TO ASSEMBLY INSTALLATION. <br />STC / IIC RATING: <br />- <br />STC / IIC TEST NUMBER: <br />. <br />. <br />FIRE RATING: <br />1HR <br />FIRE TEST NUMBER: <br />CBC TABLE 721.1 (3): <br />ITEM NUMBER: 21-1.1 <br />24" O.C. MAX <br />CBC 721.1(3) ITEM 21-1.1: <br />WOOD JOISTS OR WOOD I-JOISTS OR FLOOR TRUSSES OR FLAT OR PITCHED ROOF <br />TRUSSES SPACED AT A MAXIMUM OF 24" O.C. WITH MIN. 1/2" WOOD STRUCTURAL <br />PANELS WITH EXTERIOR GLUE APPLIED AT RIGHT ANGLES TO TOP OF JOIST OR TOP <br />CHORD OF TRUSSES WITH 8d NAILS. THE WOOD STRUCTURAL PANEL THICKNESS <br />SHALL NOT BE LESS THAN NOMINAL 1/2" NOR LESS THAN REQUIRED BY CHAPTER 23. <br />GYPSUM BOARD: <br />BASE LAYER 5/8" TYPE X GYPSUM BOARD APPLIED AT RIGHT ANGLES TO JOISTS OR <br />TRUSSES 24" O.C. WITH 1-1/4" TYPE S OR TYPE W DRYWALL SCREWS 24" O.C. FACE <br />LAYER 5/8" TYPE X GYPSUM BOARD OR VENEER BASE APPLIED AT RIGHT ANGLES TO <br />JOISTS OR TRUSSES THROUGH BASE LAYER WITH 1-7/8" TYPE S OR TYPE W DRYWALL <br />SCREWS 12" O.C. AT JOINTS AND INTERMEDIATE JOISTS OR TRUSS. FACE LAYER TYPE <br />G DRYWALL SCREWS PLACED 2" BACK ON EITHER SIDE OF FACE LAYER END JOINTS 12" <br />O.C. <br />ADDED TO ASSEMBLY: <br />ABOVE: FINISH FLOORING <br />MIN. 1/2" PLYWOOD SHEATHING <br />REFER TO STRUCTURAL <br />FINISH FLOORING <br />2x WOOD JOISTS AT 24" O.C. <br />REFER TO STRUCTURAL <br />(2) LAYERS 5/8" TYPE X GYPSUM BOARD <br />1 <br />H <br />O <br />U <br />R <br /> <br />A <br />S <br />S <br />E <br />M <br />B <br />L <br />Y <br />FC3 <br />CCOPYRIGHT <br />It is the clients responsibility prior to or during construction to notify the architect in writing <br />of any perceived errors or omissions in the plans and specifications of which a contractor <br />thoroughly knowledgeable with the building codes and methods of construction should <br />reasonably be aware. Written instructions addressing such perceived errors or omissions <br />shall be received from the architect prior to the client or clients subcontractors proceeding <br />with the work. The client will be responsible for any defects in construction if these <br />procedures are not followed. <br />Zohrabians Art of Design <br />700 Palm Drive, Suite 106 <br />Glendale, CA 91202 <br />zartofdesign.com <br />818.300.9420 <br />4t <br />h <br /> <br />P <br />l <br />a <br />n <br /> <br />C <br />h <br />e <br />c <br />k <br /> <br />S <br />u <br />b <br />m <br />i <br />t <br />t <br />a <br />l <br />No.Date Description <br />06/05/2024 100% DD SET <br />06/14/2024 50% CD PROGRESS SET <br />06/21/2024 75% CD PROGRESS SET <br />07/02/2024 NEIGHBORHOOD REVIEW <br />07/10/2024 1ST PLAN CHECK SUBMITTAL <br />09/13/2024 2ND PLAN CHECK SUBMITTAL <br />11/07/2024 3RD PLAN CHECK SUBMITTAL <br />12/18/2024 4TH PLAN CHECK SUBMITTAL <br />82 <br />9 <br /> <br />N <br />. <br /> <br />G <br />A <br />R <br />F <br />I <br />E <br />L <br />D <br /> <br />S <br />T <br />R <br />E <br />E <br />T <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />1 <br />Santa Ana, CA 92701 <br />829 N. Garfield Street <br />Name: <br />Project Contact: <br />Phone: <br />Email: <br /> <br />Principal: <br />Z.AOD Project No:2024-02 <br />Arthur Zohrabians <br />818.300.9420 <br />Arthur Zohrabians <br />info@zartofdesign.com <br />Phone No.:949.922.7075 <br />Email:vanitapuri@gmail.com <br />Owner <br />GA <br />R <br />F <br />I <br />E <br />L <br />D <br /> <br />R <br />E <br />S <br />T <br />O <br />R <br />A <br />T <br />I <br />O <br />N <br /> <br />/ <br /> <br />R <br />E <br />M <br />O <br />D <br />E <br />L <br />Address: <br />Ren.11/30/25 <br />A <br />No. C37490 <br />A <br />A FOILOFC <br />R <br />INTA <br />S <br />ET <br />TC <br />A RCHITE <br />DESNECIL <br />RTHUR <br />HAMAYAK ZOHRABI <br />A <br />SN <br />VVS Estates, LLC <br />1 <br />Vanita Soni PuriAttn: <br />2 <br />3 <br />FIRE-RESISTANCE <br />RATED ASSEMBLY <br />DETAILS <br />A900 <br />EXISTING FLOOR / CEILING ASSEMBLYPROPOSED FLOOR / CEILING ASSEMBLY <br />PROPOSED FLOOR / CEILING ASSEMBLY PROPOSED FLOOR / CEILING ASSEMBLY <br />EXISTING WALL ASSEMBLY <br />PROPOSED WALL ASSEMBLY <br />EXISTING WALL ASSEMBLY <br />PROPOSED <br />WALL <br />ASSEMBLY <br />PROPOSED WALL ASSEMBLYPROPOSED WALL ASSEMBLY <br />PROPOSED WALL ASSEMBLY <br />W3 <br />W4W6 <br />(2) LAYERS 5/8" TYPE X GYPSUM BOARD <br />2x4 WOOD STUDS AT 16" O.C. <br />2-HR INTERIOR WOOD STUD <br />SCALE: 1 1/2" = 1'-0" <br />LOAD-BEARING <br />OPTIONAL VARIATIONS AS FOLLOWS: <br />CONTRACTOR SHALL READ AND BE FAMILIAR WITH TEST REPORT AND RELATED SOUND <br />AND FIRE TEST REPORTS LISTED PRIOR TO ASSEMBLY INSTALLATION. <br />STC RATING: <br />- <br />STC TEST NUMBER: <br />- <br />FIRE RATING: <br />2HR <br />FIRE TEST NUMBER: <br />GA FILE NO.: <br />WP 4135 <br />PLYWOOD SHEATHING WHERE OCCURS <br />REFER TO STRUCTURAL DRAWINGS <br />(2) LAYERS 5/8" TYPE X GYPSUM BOARD <br />16" O.C. <br />(24" MAX) <br />GA FILE NO. WP 4135: <br />BASE LAYER 5/8" TYPE X GYPSUM WALLBOARD OR GYPSUM VENEER BASE APPLIED AT <br />RIGHT ANGLES TO EACH SIDE OF 2x4 WOOD STUDS 24" O.C. WITH 6d COATED NAILS, <br />1-7/8" LONG, 0.085" SHANK, 1/4" HEADS, 24" O.C. FACE LAYER 5/8" TYPE X GYPSUM <br />WALLBOARD OR GYPSUM VENEER BASE APPLIED AT RIGHT ANGLES TO EACH SIDE WITH <br />8d COATED NAILS, 2-3/8" LONG, 0.100" SHANK, 1/4" HEADS, 8" O.C. JOINTS STAGGERED <br />24" EACH SIDE. (GREATER STUD SIZES (DEPTH) SHALL BE PERMITTED). <br />WOOD STRUCTURAL PANELS SHALL BE PERMITTED TO BE INSTALLED BETWEEN THE <br />FIRE PROTECTION AND THE WOOD STUDS ON EITHER THE INTERIOR OR EXTERIOR SIDE <br />OF THE WOOD FRAME ASSEMBLIES, PROVIDED THE LENGTH OF THE FASTENERS USED <br />TO ATTACH THE FIRE PROTECTION IS INCREASED BY AN AMOUNT AT LEAST EQUAL TO <br />THE THICKNESS OF THE WOOD STRUCTURAL PANEL. <br />1" SHAFT LINER GYPSUM BOARD <br />2-1/2" STEEL "C-H", "C-T" OR "I" STUDS <br />AT 24" O.C. <br />(2) LAYERS 5/8" TYPE X GYPSUM BOARD <br />2-1/2" STEEL "E" STUDS AT END WALL <br />CONDITION <br />1-1/2" GLASS FIBER INSULATION <br />PROPRIETARY <br />GA FILE NO. WP 7060: <br />ONE LAYER 1" x 24" PROPRIETARY TYPE X GYPSUM PANELS INSERTED BETWEEN 2-1/2" <br />FLOOR AND CEILING J RUNNERS WITH TAB FLANGE SECTION OF 2-1/2" STEEL C-H, C-T, <br />OR I STUDS BETWEEN PANELS. <br />OPPOSITE SIDE: BASE LAYER 5/8" PROPRIETARY TYPE X GYPSUM WALLBOARD OR <br />GYPSUM VENEER BASE APPLIED PARALLEL TO STUDS WITH 1" TYPE S DRYWALL <br />SCREWS 24" O.C. FACE LAYER 5/8" PROPRIETARY TYPE X GYPSUM WALLBOARD OR <br />GYPSUM VENEER BASE APPLIED PARALLEL TO STUDS WITH 1-5/8" TYPE S DRYWALL <br />SCREWS 12" O.C. (GREATER STUD SIZES (DEPTH) AND HEAVIER GAGE SHALL BE <br />PERMITTED). <br />PROPRIETARY GYPSUM BOARD: <br />NATIONAL GYPSUM COMPANY <br />5/8" GOLD BOND BRAND FIRE-SHIELD GYPSUM WALLBOARD <br />1" GOLD BOND BRAND FIRE-SHIELD SHAFTLINER <br />HORIZONTAL SHAFT WALLS: ALLOWED PER P.E.I. REPORT AER-09038 WITH ADDED 5/8" <br />PROPRIETARY TYPE X GYPSUM WALLBOARD OR GYPSUM VENEER AT OPPOSITE SIDE <br />OF 1" GYPSUM PANEL. <br />2-HR INTERIOR STEEL STUD SHAFT <br />SCALE: 1 1/2" = 1'-0" <br />NON-LOAD-BEARING <br />OPTIONAL VARIATIONS AS FOLLOWS: <br />CONTRACTOR SHALL READ AND BE FAMILIAR WITH TEST REPORT AND RELATED SOUND <br />AND FIRE TEST REPORTS LISTED PRIOR TO ASSEMBLY INSTALLATION. <br />STC RATING: <br />- <br />STC TEST NUMBER: <br />- <br />FIRE RATING: <br />2HR <br />FIRE TEST NUMBER: <br />GA FILE NO.: <br />WP 7060 <br />24" O.C. MAX <br />5/8" GYPSUM BOARD <br />2x4 WOOD STUDS AT 16" O.C. <br />OPTIONAL VARIATIONS AS FOLLOWS: <br />CONTRACTOR SHALL READ AND BE FAMILIAR WITH TEST REPORT AND RELATED SOUND <br />AND FIRE TEST REPORTS LISTED PRIOR TO ASSEMBLY INSTALLATION. <br />STC RATING: <br />- <br />STC TEST NUMBER: <br />- <br />FIRE RATING: <br />0-HR <br />16" O.C. MAX <br />(PPSD) NON-RATED EXT. WOOD STUD <br />SCALE: 1 1/2" = 1'-0" <br />FIRE TEST NUMBER: <br />- <br />FILL STUD CAVITY DEPTH WITH GLASS FIBER INSULATION. <br />REFER TO TM00 - TM01 OF MECH. DWGS. <br />7/8" THICK 3 COAT EXTERIOR CEMENT PLASTER <br />ASSEMBLY OVER SELF-FURRING EXTERIOR METAL LATH <br />OVER WEATHER RESISTIVE BARRIER <br />PLYWOOD SHEATHING; WHERE OCCURS <br />REFER TO STRUCTURAL DRAWINGS <br />1 1 <br />1 <br />PROPOSED WALL ASSEMBLY <br />5/8" GYPSUM BOARD <br />2x4 WOOD STUDS AT 16" O.C. <br />OPTIONAL VARIATIONS AS FOLLOWS: <br />CONTRACTOR SHALL READ AND BE FAMILIAR WITH TEST REPORT AND RELATED SOUND <br />AND FIRE TEST REPORTS LISTED PRIOR TO ASSEMBLY INSTALLATION. <br />STC RATING: <br />- <br />STC TEST NUMBER: <br />- <br />FIRE RATING: <br />0HR <br />PLYWOOD SHEATHING WHERE OCCURS <br />REFER TO STRUCTURAL DRAWINGS <br />5/8" GYPSUM BOARD <br />16" O.C. MAX <br />(PPSD) NON-RATED INT. WOOD STUD <br />SCALE: 1 1/2" = 1'-0" <br />FIRE TEST NUMBER: <br />- <br />FILL STUD CAVITY DEPTH WITH GLASS <br />FIBER INSULATION, WHERE OCCURS <br />W5 <br />1 3 <br />HOLD- 829 N <br />Garfield St1/15/2025
The URL can be used to link to this page
Your browser does not support the video tag.