Laserfiche WebLink
SYMBOL DESCRIPTION <br />@ AT <br />AB ANCHOR BOLT <br />ABV ABOVE <br />ACI AMERICAN CONCRETE INSTITUTE <br />AISC AMERICAN INSTITUTE OF STEEL CONSTRUCTION <br />ALT ALTERNATIVE / ALTERNATE <br />ARCH ARCHITECT / ARCHITECTURAL <br />ASTM AMERICAN STANDARD FOR TESTING AND MATERIALS <br />AWS AMERICAN WELDING SOCIETY <br />B, (B), BOT BOTTOM <br />BM BEAM <br />BN BOUNDARY NAIL <br />BLDG BUILDING <br />BLK BLOCKING <br />BRG BEARING <br />CANT CANTILIEVER <br />CB CEILING BEAM <br />CGS CENTEROID OF TENDON <br />CIP CAST IN PLACE <br />CBC CALIFORNIA BUILDING CODE <br />CJ CONSTRUCTION JOINT / CEILING JOIST <br />CL CENTERLINE <br />CLG CEILING <br />CLR CLEAR <br />CMU CONCRETE MASORNY UNIT <br />CONST CONSTRUCTION <br />CONT CONTINUOUS <br />CTR CENTER <br />DIA DIAMETER <br />DIM DIMENSION <br />DJ DECK JOIST <br />DL DEAD LOAD <br />DWG DRAWING(S) <br />EXIST, (E)EXISTING <br />EA EACH <br />EF EACH FACE <br />ELEV ELEVATION <br />ENGR ENGINEER <br />EQ EQUAL <br />EW EACH WAY <br />FF FINISH FLOOR <br />FLR FLOOR <br />FND FOUNDATION <br />FOB FACE OF BEAM <br />FOC FACE OF CONCRETE / FACE OF COLUMN <br />FOM FACE OF MASONRY <br />FOW FACE OF WALL <br />FTG FOOTING <br />GA GAUGE <br />GALV GALVANIZED <br />GB GRADE BEAM <br />GLB GLU LAM BEAM <br />HT HEIGHT <br />HD HOLD DOWN <br />HDR HEADER <br />HGR HANGER <br />HORIZ HORIZONTAL <br />H.P.HIGH POINT <br />HSS HOLLOW STRUCTURAL STEEL <br />ID INSIDE DIAMTER <br />IF INSIDE FACE <br />INT INTERIOR <br />JST JOIST <br />JT JOINT <br />K KIPS <br />KS KING STUD <br />LGS LIGHT GAUGE STUDS <br />LL LIVE LOAD <br />LP LOW POINT <br />LVL LAMINATED VENEER LUMBER <br />LSL TIMBERSTRAND <br />MANUF MANUFACTURER / MANUFACTURED <br />MAX MAXIMUM <br />MB MACHINE BOLT <br />MD MID-DEPTH <br />MECH MECHANICAL <br />MID MIDDLE <br />MIN MINIMUM <br />MISC MISCELLANEOUS <br />ML MICROLLAM <br />MULT MULTIPLE <br />N, (N)NEW <br />NA NATURAL AXIS <br />NO.,#NUMBER <br />NG NATURAL GRADE <br />NTS NOT TO SCALE <br />O/OVER <br />O.C.ON CENTER <br />OD OUTSIDE DIAMETER <br />OF OUTER FACE <br />OPP OPPOSITE <br />ORIG ORIGINAL <br />PERP PERPENDICULAR <br />PL PARALLAM / PLATE <br />PSL PARALLEL-STRAND LUMBER <br />PT POST-TENSION <br />PTDF PRESSURE TREATED DOUGLAS FIR <br />PLYWD PLYWOOD <br />RD ROOF DRAIN <br />RR ROOF RAFTER <br />REINF REINFORCEMENT <br />REQ REQUIRED / REQUIREMENT <br />SCHED SCHEDULE <br />SEL SELECT <br />SHTG SHEATHING <br />SIM SIMILAR <br />SOG SLAB-ON-GRADE <br />SPECS SPECIFICATIONS <br />SQ SQUARE <br />STAGG STAGGER(ED) <br />STD STANDARD <br />STL STEEL <br />STRUCT STRUCTURAL <br />SW SHEAR WALL <br />SWAB SHEAR WALL & ANCHOR BOLT SCHEDULE <br />SYM SYMMETERICAL <br />T TOP <br />T&G TONGUE AND GROOVE <br />TOC TOP OF CURB <br />TOS TOP OF SLAB OR TOP OF STEEL <br />TP TOP PLATES <br />TS TIMBERSTRAND <br />TYP TYPICAL <br />U.N.O.UNLESS NOTED OTHERWISE <br />VERT VERTICAL <br />VTR VENT TO ROOF <br />WD WOOD <br />WT WEIGHT <br />W/WITH <br />W/O WITHOUT <br />DESIGN INFORMATION (CBC 2022)GARFIELD RESTORATION / REMODEL <br />829 N. GARFIELD STREET <br />SANTA ANA, CA 92701 <br />GENERAL NOTESABBREVIATIONS DRAWING INDEX <br />DEAD LOADS <br />PROJECT TEAM <br />VICINITY MAP <br />N.T.S <br />WORK PERFORMED SHALL COMPLY WITH THE FOLLOWING GENERAL REQUIREMENTS UNLESS NOTED <br />ON PLANS OR SPECIFICATIONS: <br />1.BUILDING CODE - 2022 CALIFORNIA BUILDING CODE (CBC) & 2022 CALIFORNIA EXISTING BUILDING <br />CODE (CEBC) WITH APPLICABLE CITY AMENDMENTS. <br />2.ALL APPLICABLE LOCAL, STATE, AND FEDERAL CODES, ORDINANCES, LAWS, REGULATIONS AND <br />PROTECTIVE GOVERNING THE SITE OF WORK. <br />3.STANDARD SPECIFICATIONS OF ASTM AS NOTED HEREIN AND AS REQUIRED BY THE BUILDING <br />CODE. <br />4.ALL WORK NEEDS TO BE PERFORMED BY QUALIFIED AND EXPERIENCED CONTRACTORS <br />FAMILIAR WITH THIS TYPE OF PROJECT CONSTRUCTION. <br />5.IN CASE OF CONFLICT, THE MORE STRINGENT REQUIREMENT SHALL GOVERN. <br />6.ON SITE VERIFICATION OF ALL DIMENSIONS AND CONDITIONS SHALL BE THE RESPONSIBILITY OF <br />THE CONTRACTOR AND SUB-CONTRACTORS. REFER TO NOTED DIMENSIONS. DO NOT SCALE <br />DRAWINGS FOR DIMENSIONS. <br />7.ENGINEER OR ARCHITECT OF RECORD IS TO BE NOTIFIED IMMEDIATELY BY THE CONTRACTOR <br />SHOULD ANY QUESTION ARISE OR ANY DISCREPANCY BE FOUND PERTAINING TO THE WORKING <br />DRAWINGS AND/OR SPECIFICATIONS. <br />8.NO DEVIATIONS FROM THESE REQUIREMENTS AND STRUCTURAL DETAILS SHALL BE MADE <br />WITHOUT THE WRITTEN APPROVAL OF THE ENGINEER OF RECORD (EOR). APPROVAL BY THE <br />INSPECTOR DOES NOT CONSTITUTE AUTHORITY TO DEVIATE FROM THE PLANS AND <br />SPECIFICATIONS. <br />9.THE DESIGN, ADEQUACY, AND SAFETY OF ERECTION BRACING, SHORING, TEMPORARY <br />SUPPORTS, ETC., IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR, AND HAS NOT BEEN <br />CONSIDERED BY THE ARCHITECT OR ENGINEER. THE CONTRACTOR IS RESPONSIBLE FOR THE <br />STABILITY OF THE STRUCTURE PRIOR TO THE APPLICATION OF ALL SHEAR WALLS, ROOF AND <br />FLOOR DIAPHRAGMS, AND FINISH MATERIALS. THE CONTRACTOR SHALL PROVIDE THE <br />NECESSARY BRACING TO PROVIDE STABILITY PRIOR TO THE APPLICATION OF THE <br />AFOREMENTIONED MATERIALS. SITE VISITS PERTAINING TO STRUCTURAL OBSERVATIONS BY <br />THE ARCHITECT OR STRUCTURAL ENGINEER SHALL NOT IMPLY THE ASSUMPTION OF ANY <br />RESPONSIBILITY IN THIS REGARD. <br />10.SPECIAL INSPECTION PER CBC SECTION 1704 IS REQUIRED AND APPLIES TO THE TYPES OF <br />WORK INDICATED ON SHEET SN1.1 (NOTE SPECIAL INSPECTORS QUALIFICATIONS AND <br />RESPONSIBILITIES SHOULD COMPLY WITH CBC SECTION 1701 REQUIREMENTS). <br />11.STRUCTURAL ANALYSIS FOR THIS PROJECT IS DONE PER APPLICABLE BUILDING CODE AT THE <br />TIME OF DESIGN CONSIDERING STANDARD OF CARE. <br />12.UPON COMPLETION OF ABOVE BY THE ENGINEER AND PRIOR TO START OF CONSTRUCTION, <br />CONTRACTOR IS RESPONSIBLE TO CHECK ALL DIMENSIONS, COORDINATE WITH THE WORK OF <br />OTHER CONSULTANTS AND OTHER TRADES TO ENSURE COMPLIANCE WITH HIS/HER <br />REQUIREMENTS. <br />13.EOR SHALL HAVE NO LIABILITY FOR WATERPROOFING OR MOISTURE TRANSMISSION ISSUES, <br />WHETHER RELATED TO CONCRETE SLABS, FOOTINGS, FOUNDATIONS, OR OTHERWISE. OWNER <br />AND CONTRACTOR SHALL BE ENTIRELY RESPONSIBLE FOR SUCH ISSUES, AND WILL DEFEND <br />AND INDEMNIFY EOR AGAINST ALL SUCH CLAIMS. <br />LEVEL LOAD DESCRIPTION <br />ROOF 12 PSF COMP. ROOFING W/ RE-ROOF 3 PSF MAX W/ DRYWALL AT CEILING. <br />LEVEL LOAD DESCRIPTION <br />ASCE 7-16 ROOF ROOF LIVE LOAD <br />LIVE LOADS <br />SEISMIC DATA <br />OCCUPANCY CATEGORY:II <br />IMPORTANCE CATEGORY:1.0 <br />SITE CLASS:D (DEFAULT) <br />SS:1.297 <br />S1:0.462 <br />SDS:1.037 <br />SMS:1.556 <br />SEISMIC DESIGN CATEGORY:D <br />SEISMIC FORCE RESISTING SYSTEM:LIGHT FRAME WALLS WITH <br />WOOD STRUCTURAL PANELS <br />RESPONSE MODIFICATION FACTOR - R:6.5 <br />SEISMIC FORCE AMPLIFICATION FACTOR - Ω:2.5 <br />SEISMIC RESPONSE COEFFICIENT - CS:0.160 (ASD 0.112) <br />ANALYSIS PROCEDURE:EQUIVALENT LATERAL FORCE <br />WIND DATA <br />WIND RISK CATEGORY:II <br />EXPOSURE CATEGORY:B <br />WIND SPEED:95 MPH <br />SOIL DATA (CODE MIN.) <br />ALLOWABLE BEARING PRESSURE:1500 PSF <br />ALLOWABLE PASSIVE PRESSURE:100 PCF <br />S-CS STRUCTURAL COVER SHEET <br />S101D EXISTING FOUNDATION & RAISED FLOOR PLAN <br />S101 PROPOSED FOUNDATION & RAISED FLOOR PLAN <br />S201D EXISTING 2ND FLOOR FRAMING PLAN <br />S201 PROPOSED 2ND FLOOR FRAMING PLAN <br />S301D EXISTING ROOF FRAMING PLAN <br />S301 PROPOSED ROOF FRAMING PLAN <br />SN0 STRUCTURAL NOTES <br />SD1 STRUCTURAL DETAILS <br />SD2 STRUCTURAL DETAILS <br />SD3 STRUCTURAL DETAILS <br />SPECIAL INSPECTIONS <br />1.SPECIAL INSPECTIONS ARE REQUIRED AS PER SECTION 1704 OF THE CALIFORNIA BUILDING CODE <br />(CBC), AND OTHER AREAS NEEDING SPECIAL INSPECTION SHOULD BE VERIFIED WITH THE <br />BUILDING OFFICIAL OF THE GOVERNING JURISDICTION. <br />2.INSPECTIONS MUST CONFORM TO CBC SECTIONS 110 AND 1704. <br />3.INSPECTIONS MUST BE CONDUCTED BY QUALIFIED INSPECTORS AND TESTING AGENCIES <br />RETAINED BY THE OWNER, AND NOT THE CONTRACTOR. INSPECTORS AND AGENCIES MUST BE <br />APPROVED BY THE GOVERNING JURISDICTION. <br />4.COPIES OF ALL INSPECTION REPORTS AND TEST RESULTS MUST BE PROVIDED TO THE OWNER, <br />BUILDING DEPARTMENT, ARCHITECT, AND ENGINEER. COPIES OF THESE REPORTS AND RESULTS <br />MUST ALSO BE KEPT AT THE JOB SITE. <br />5.A FINAL REPORT FOR ALL INSPECTIONS AND TESTING, STATING THAT THE WORK WAS COMPLETED <br />IN ACCORDANCE WITH THE APPROVED PLANS AND ALL APPLICABLE CODES AND STANDARDS, <br />MUST BE SUBMITTED TO THE OWNER, BUILDING DEPARTMENT, ARCHITECT, AND ENGINEER. <br />6.STRUCTURAL OBSERVATION MAY BE REQUIRED BY THE JURISDICTION, ENGINEER, OR OWNER, <br />BUT THIS DOES NOT REPLACE ANY OF THE REQUIRED INSPECTIONS BY DEPUTY INSPECTORS OR <br />THE LOCAL JURISDICTION. <br />7.SPECIAL INSPECTION IS REQUIRED FOR SPECIFIC TYPES OF WORK, INCLUDING: <br />CAST-IN-PLACE DRILLED PILES OR CAISSONS <br />FIELD WELDING, EPOXY, WELDING OF REINFORCING STEEL <br />HIGH STRENGTH BOLTING <br />REINFORCEMENT AND TENDON PLACEMENT IN CONCRETE OVER 2500 PSI <br />TITEN HD SCREW ANCHORS. <br />8.NOTE SPECIAL INSPECTION IS ALSO REQUIRED FOR CONCRETE WITH A COMPRESSIVE STRENGTH <br />(F'C) OVER 2500 PSI. EXCEPTION: WHERE HIGHER F'C IS USED FOR COMPLIANCE WITH SULFATE <br />EXPOSURE ONLY WHERE A SOILS REPORT IS NOT PROVIDED. <br />9.ADDITIONAL ITEMS REQUIRING SPECIAL INSPECTION MAY BE NOTED ON THE PLANS. <br />10.IT IS IMPORTANT TO ADHERE TO THESE REQUIREMENTS AND WORK WITH QUALIFIED INSPECTORS <br />AND TESTING AGENCIES TO ENSURE COMPLIANCE WITH THE CBC AND ENSURE THE QUALITY AND <br />SAFETY OF THE CONSTRUCTION PROJECT. <br />ROOF 20 PSF <br />OWNER: <br />VVS ESTATES LLC (ATTN: VANITA SONI PURI) <br />829 N. GARFIELD STREET <br />SANTA ANA, CA 92701 <br />ARCHITECT: <br />ZOHRABIANS ART OF DESIGN <br />700 PALM DRIVE, SUITE 106 <br />GLENDALE, CA 91202 <br />ZARTOFDESIGN.COM <br />818.300.9420 <br />STRUCTURAL ENGINEERING: <br />ELIE SAYEGH STRUCTURAL ENGINEERING, INC. <br />947 E FAIRWAY DR, <br />ORANGE, CA 92866 <br />(714) 400-5584 <br />STRUCTURAL OBSERVATIONS <br />1.THE OWNER SHALL EMPLOY THE ENGINEER OF RECORD OR AN APPROVED <br />REPRESENTATIVE TO COMPLETE STRUCTURAL OBSERVATIONS. <br />2.A STRUCTURAL OBSERVATION DOES NOT WAVE THE BUILDING CODE SPECIAL <br />INSPECTION REQUIREMENTS. <br />3.A STRUCTURAL OBSERVATION CONSISTS OF THE VISUAL OBSERVATION OF THE <br />STRUCTURAL SYSTEMS AT VARIOUS SIGNIFICANT CONSTRUCTION MILESTONES. <br />4.A STRUCTURAL OBSERVATION SCOPE IS LIMITED TO THE CONSTRUCTION'S GENERAL <br />CONFORMANCE WITH THE APPROVED PLANS. <br />5.OWNER OR CONTRACTOR SHALL NOTIFY THE ENGINEER A MINIMUM OF 3 WORKING <br />DAYS PRIOR TO SCHEDULING A STRUCTURAL OBSERVATION. SCHEDULING IS THE SOLE <br />RESPONSIBILITY OF THE OWNER/CONTRACTOR. <br />6.FOR THIS PROJECT, STRUCTURAL OBSERVATIONS ARE REQUIRED AT THE FOLLOWING <br />MILESTONES: <br />A.FOUNDATION OBSERVATION TO BE COMPLETED PRIOR TO CONCRETE. <br />B.WALLS, FLOORS, AND ROOFS FRAMING PRIOR TO INSTALLATION OF INTERIOR OR <br />EXTERIOR FINISHES (INCLUDING INSULATION) <br />2ND FLR 16 PSF VINYL, 12" SHTG, 1X DIAG, 2X12, W/DRYWALL AT CEILING <br />SUB FLR 14 PSF VINYL, 12" SHTG, 1X DIAG, 2X6, W/DRYWALL AT CEILING <br />ASCE 7-16 ROOF RESIDENTIAL LIVE LOAD2ND FLR 40 PSF <br />ASCE 7-16 ROOF RESIDENTIAL LIVE LOADSUB FLR 40 PSF <br />REMODEL & CONTRACTOR NOTES <br />1.THE CONTRACTOR SHALL TAKE ALL NECESSARY MEASURES TO PROTECT THE WORKFORCE, <br />OTHER PERSONEL, AND THE STRUCTURE ITESELF DURING CONSTRUCTION. <br />2.TEMPORARY SHORING OR BRACING OF WALLS, FLOORS, OR ROOF IS THE RESPONSIBILITY OF <br />THE CONTRACTOR. <br />3.THE CONTRACTOR SHALL LOCATE ALL UTILITIES WHERE WORK IS TO BE CONDUCTED & <br />PROTECT FROM ANY DAMAGE. <br />4.THE ENGINEER OF RECORD HAD MADE EFFORTS TO ASCERTAIN THE EXISTING FRAMING & <br />FOUNDATION CONDITIONS, HOWEVER NOT ALL SUPPORT CONDITIONS WERE UNCOVERED AND <br />EXISTING CONDITIONS MAY DIFFER FROM WHAT IS SHOWN ON THE DRAWINGS. REMOVAL OF <br />CEILING FINISHES TO DETERMINE FRAMING ABOVE, OR FLOOR FINISHES TO DETERMINE <br />FOUNDATION CONDITIONS IS RECOMENDED. <br />5.THE CONTRACT COMPLETING THE WORK SHALL REVIEW THE FRAMING & FOUNDATION PLANS <br />AND CONFIRM THEY ARE FAMILIAR WITH HTIS TYPE WORK. <br />6.CARE SHALL BE TAKEN DURING THE DEMO PHASE AND TEMPORARY SHORING & SUPPORT SHALL <br />BE PROVIDED WHERE NECESSARY. <br />7.IF THERE ARE ANY LOCATIONS WHERE EXISTING SUPPORTS ARE TO BE REMOVED & THE <br />STRUCTURAL PLANS DOE NOT SHOW NEW FRAMING OR NEW SUPPORT, CONTACT THE EOR <br />IMMEDIATELY. <br />REVISION HISTORY <br />2ND PLAN CHECK SUBMITTAL <br />09 - 13 - 20241 <br />ALL DRAWINGS & WRITTEN MATERIAL HEREIN CONSTITUTES THE <br />ENGINEER'S ORIGINAL WORK. THE SAME SHALL NOT BE DUPLICATED, <br />USED, OR SHARED WITHOUT THE EXPRESS WRITTEN CONSENT OF THE <br />ENGINEER. ESSE'S ALL RIGHTS RESERVED <br />947 E. FAIRWAY DRIVE, <br />ORANGE, CA 92866 <br />(714) 400 - 5584 <br />NO.DATE ISSUE <br />SHEET NO. <br />GA <br />R <br />F <br />I <br />E <br />L <br />D <br /> <br />R <br />E <br />S <br />T <br />O <br />R <br />A <br />T <br />I <br />O <br />N <br /> <br />/ <br /> <br />R <br />E <br />M <br />O <br />D <br />E <br />L <br />VV <br />S <br /> <br />E <br />S <br />T <br />A <br />T <br />E <br />S <br /> <br />L <br />L <br />C <br />82 <br />9 <br /> <br />N <br />. <br /> <br />G <br />A <br />R <br />F <br />I <br />E <br />L <br />D <br /> <br />S <br />T <br />R <br />E <br />E <br />T <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />1 <br />07-09-2024 <br />ELIE SAYEGH, PE <br />0127 <br /> <br /> <br />DOCUMENTS ORIGINAL ISSUE DATE: <br />PROJECT ENGINEER: <br />PROJECT NO. <br />2N <br />D <br /> <br />P <br />L <br />A <br />N <br /> <br />C <br />H <br />E <br />C <br />K <br /> <br />S <br />U <br />B <br />M <br />I <br />T <br />T <br />A <br />L <br />2ND PLAN CHECK <br />SUBMITTAL109-13-2024 <br />S-CS <br />ST <br />R <br />U <br />C <br />T <br />U <br />R <br />A <br />L <br /> <br />C <br />O <br />V <br />E <br />R <br /> <br />S <br />H <br />E <br />E <br />T <br />07/01/202409/13/2024 <br />HOLD- 829 N <br />Garfield St1/15/2025