GENERAL NOTES <br />1.CONTRACTOR'S RESPONSIBILITY TO VERIFY GRADES, DIMENSIONS, ELEVATIONS, <br />AND CONDITIONS PRIOR TO BIDDING AND CONSTRUCTION. NOTIFY ENGINEER AND <br />ARCHITECT OF DISCREPANCIES. <br />2.USE STRUCTURAL DRAWINGS IN CONJUNCTION WITH ALL OTHER RELATED <br />DRAWINGS. COORDINATE ALL WORK, INCLUDING SUB TRADES. <br />3.NOTIFY STRUCTURAL ENGINEER OF CONFLICTS FOUND BETWEEN <br />SPECIFICATIONS, NOTES, PLANS, AND DETAILS. <br />4.DO NOT SCALE DIMENSIONS FROM DRAWINGS. <br />5.WORKMANSHIP AND MATERIALS TO CONFORM TO CALIFORNIA BUILDING CODE <br />AND LOCAL ORDINANCES. <br />6.CONTRACTOR TO PROVIDE MEASURES FOR STRUCTURAL PROTECTION, BRACING, <br />AND SHORING DURING CONSTRUCTION. <br />7.WALLS, DOOR OPENINGS, AND WINDOW OPENINGS DETERMINED FROM <br />ARCHITECTURAL DRAWINGS. COORDINATE OTHER OPENINGS FOR MEP <br />REQUIREMENTS. <br />8.COORDINATE OPENINGS, SLEEVES, SLAB ELEVATIONS, ETC. BEFORE <br />CONSTRUCTION. STRUCTURAL MEMBERS NOT TO BE CUT OR NOTCHED UNLESS <br />DETAILED ON PLANS. <br />9.MATERIALS TO BE FURNISHED AS SHOWN, UNLESS APPROVED IN WRITING BY <br />ARCHITECT, OWNER, AND STRUCTURAL ENGINEER. <br />10."APPROVED" OR "APPROVAL" ARE DEFINED AS GENERAL ACCEPTANCE. <br />CONTRACTOR REMAINS LIABLE FOR REQUIRED MATERIALS AND LABOR <br />COORDINATION. <br />11.DETAILS AND SECTIONS APPLY TO LIKE CONDITIONS, TYPICAL DETAILS TO BE <br />USED UNLESS INDICATED OTHERWISE. <br />12.CONNECTIONS OF ITEMS SUPPORTED BY PRIMARY STRUCTURE TO BE <br />COORDINATED BY RESPECTIVE DISCIPLINES. <br />13.CONTRACTOR IS RESPONSIBLE FOR LOCATING AND PROTECTING EXISTING <br />UTILITIES. <br />14.VIBRATION EFFECTS OF EQUIPMENT NOT CONSIDERED BY STRUCTURAL <br />ENGINEER. <br />15.FLOOR SYSTEMS NOT DESIGNED FOR WATER BEDS, NOTIFY ENGINEER OF <br />RECORD IF ANTICIPATED. <br />16.CHANGES TO DRAWINGS AND SPECIFICATIONS REQUIRE CONSENT OF THE EOR. <br />FOUNDATIONS & SOILS <br />1.THE FOUNDATION DESIGN RELIES ON A GEOTECHNICAL REPORT OR MINIMUM <br />PRESUMPTIVE SOIL VALUES IN ACCORDANCE TO THE BUILDING CODE. WHEN A <br />SOILS REPORT HAS BEEN COMPLETED, IT SHALL BE MADE PART OF THE <br />CONTRACT DOCUMENTS. ADDITIONALLY, THE CONTRACTOR SHALL COMPLY WITH <br />ALL THE REPORT REQUIREMENTS AND SHALL KEEP A COPY AVAILABLE ON THE <br />CONSTRUCTION SITE AT ANYTIME DURING THE LENGTH OF THE CONSTRUCTION. <br />2.WHERE A GEOTECHNICAL ENGINEER IS ENGAGED & A SOILS REPORT IS PROVIDED <br />FOR THE PROJECT IN LIEW OF RELYING ON PRESUMPTIVE SOILS VALUES FOR THE <br />FOUNDATION, THE FOLLOW SHALL APPLY: <br />2.1.THE GEOTECHNICAL ENGINEER SHALL NOTIFY THE EOR OF ANY REVISIONS, <br />CHANGES, OR ALTERATIONS TO THE APPROVED SOILS REPORT. <br />2.2.THE GEOTECHNICAL ENGINEER SHALL INSPECT AND APPROVE THE <br />FOUNDATION TRENCHES PRIOR TO PLACEMENT OF REINFORCEMENT, <br />SCHEDULING A CITY OR COUNTY FOUNDATION INSPECTION, OR POURING <br />CONCRETE. <br />2.3.EXCAVATIONS, FILLING OR BACK FILLING, BUILDING PADS SHALL BE <br />INSPECTED AND APPROVED BY THE GEOTECHNICAL ENGINEER. <br />3.CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SHORING (RETAINING WALLS, <br />BUILDING FLOORS, WALLS, EXCAVATIONS, CONCRETE FORMS, ETC.). <br />4.FOOTINGS AND SLAB ON GRADES SHALL BEAR OVER APPROVED COMPACTED FILL <br />OR UNDISTURBED NATURAL GRADE. <br />5.ALL COMPACTED FILL SHALL BE PLACED AS REQUIRED BY THE GEOTECHNICAL <br />ENGINEER USING APPROVED METHODS AND HAVING ACHIEVED A MINIMUM <br />DENSITY OF 90% IN ACCORDANCE WITH ASTM D-1557. THE CONTRACTOR SHALL <br />SUPPLY THE BUILDING INSPECTOR ALL REQUIRED COMPACTION REPORTS WITH <br />WRITTEN APPROVAL FROM THE GEOTECHNICAL ENGINEER. <br />6.CORROSIVENESS OF THE SITE SOILS SHALL BE INVESTIGATED BY THE <br />GEOTECHNICAL ENGINEER. WHERE CORROSIVENESS IS ENCOUNTERED, THE <br />GEOTECHNICAL ENGINEER OR CORROSION ENGINEER SHALL PROVIDE <br />MITIGATION MEASURES FOR CORROSIVE SOILS. <br />7.RETAINING WALLS HAVE BEEN DESIGNED FOR DRAINED OR FREE DRAINING <br />CONDITIONS. BACK FILL AGAINST RETAINING WALLS SHALL BE MAINTAINED EVEN <br />ON EACH SIDE OF THE WALL UNTIL THE LOWER OF THE FINISH GRADES IS <br />ATTAINED. <br />8.DESIGN OF RETAINING WALL DRAINS, DRAINAGE SYSTEM, AND MAINTENANCE <br />PROGRAM IS BY OTHERS. UNLESS NOTED OTHERWISE, RETAINING WALLS SHALL <br />NOT BE SURCHARGED BY ADJACENT FOOTINGS OR CONSTRUCTION EQUIPMENTS <br />9. <br />CONCRETE <br />1.PERFORM CONCRETE WORK IN COMPLIANCE WITH ACI 301. <br />2.PROVIDE NORMAL WEIGHT AGGREGATES OF NATURAL SAND AND ROCK COMPLYING <br />WITH ASTM C33. <br />3.PROVIDE PORTLAND CEMENT CONFORMING TO ASTM C150 TYPE II/V. <br />4.THE MAXIMUM WATER-CEMENT RATIO FOR ALL FOUNDATION IS AND SLABS ON GRADE <br />SHALL NOT EXCEED 0.45. <br />5.PROVIDE NORMAL WEIGHT CONCRETE (145 PCF) (U.N.O.) WITH PROVEN SHRINKAGE. <br />6.DESIGN IS BASED UPON CARBONATE AGGREGATE. CONTRACTOR TO NOTIFY <br />STRUCTURAL ENGINEER OR CLEARLY NOTE ON THE MIX DESIGN IF OTHER AGGREGATE <br />IS USED. <br />7.CHARACTERISTICS OF LESS THAN 0.055 PERCENT, ATTAINING MINIMUM COMPRESSIVE <br />STRENGTHS AT 28 DAYS (f'c) AS FOLLOWS, UNO: <br />7.1.RETAINING WALL FOOTINGS 2500 PSI <br />7.2.CONV. SOG & STEM WALL FOUNDATION (1 & 2-STORY)2500 PSI <br />7.3.CONV. SLAB ON GRADE FOUNDATION (3+ STORY)3000 PSI <br />7.4.MAT FOUNDATION 4000 PSI <br />7.5.COLUMNS 5000 PSI <br />7.6.SHEAR WALLS 5000 PSI <br />7.7.ELEVATED SLABS & BEAMS 5000 PSI <br />7.8.METAL DECK FILL 5000 PSI <br />8.THE NOMINAL MAXIMUM SIZE OF COURSE AGGREGATE SHALL NOT BE LARGER THAN: <br />8.1.1/5 THE NARROWEST DIMENSION BETWEEN SIDES OF FORMS; <br />8.2.1/3 THE DEPTH OF SLABS; <br />8.3.3/4 THE MINIMUM CLEAR SPACING BETWEEN INDIVIDUAL REINFORCING BARS OR <br />WIRES, BUNDLES OF BARS, INDIVIDUAL TENDONS, BUNDLED TENDONS, OR DUCTS; <br />8.4.THE CONCRETE COVER <br />9.SUBMIT CONCRETE DESIGN MIX DESIGN FOR EACH TYPE AND COMPRESSIVE <br />STRENGTH OF CONCRETE REQUIRED, SIGNED AND SEALED BY A REGISTERED CIVIL <br />ENGINEER. (STRUCTURAL ENGINEER). BASE DESIGN MIX ON FIELD EXPERIENCE OR <br />TRIAL MIXTURES AS STIPULATED IN THE CBC. <br />10.SUBMIT SHOP DRAWING TO THE EOR INDICATING LOCATIONS OF CONCRETE <br />CONSTRUCTION JOINTS (IF NOT ALREADY INDICATED ON THE STRUCTURAL PLANS) <br />PRIOR TO PLACING CONCRETE. LOCATE JOINTS AT LOCATIONS TO MINIMIZE EFFECTS <br />OF SHRINKAGE & NEAR POINTS OF LOW STRESSES. <br />11.SLUMP SHALL BE 4 INCHES. <br />12.DO NOT USE CONCRETE CONTAINING CHLORIDES. <br />13.DO NOT EMBED CONDUITS, PIPES, OR SLEEVES IN STRUCTURAL CONCRETE EXCEPT <br />WHERE SPECIFICALLY DETAILED OR ACCEPTED BY THE EOR. ELECTRICAL CONDUIT <br />DRAWINGS SHALL BE SUBMITTED FOR REVIEW BY THE EOR. <br />14.FORM EXPOSED CORNERS OF COLUMNS, BEAMS AND WALLS WITH 3/4 INCH CHAMFERS <br />UNLESS NOTED OTHERWISE. <br />15.PROVIDE KEYS IN CONSTRUCTION JOINTS UNLESS NOTED OTHERWISE. <br />16.THOROUGHLY CLEAN, REMOVE DIRT & DERBIES, WET, AND REMOVE STANDING WATER <br />IN CONSTRUCTION JOINTS BEFORE PLACING NEW CONCRETE. AT VERTICAL JOINTS, <br />SLUSH WITH A COAT OF NEAT CEMENT BEFORE PLACING NEW CONCRETE. <br />17.MAINTAIN CONCRETE ABOVE 50 DEGREES FAHRENHEIT AND IN A MOIST CONDITION FOR <br />A MINIMUM OF 7 DAYS AFTER PLACEMENT.STRUCTURAL STEEL <br />1.ALL MATERIAL, DETAILING, FABRICATION, WORKMANSHIP, AND ERECTION <br />SHALL CONFORM TO THE AISC MANUAL OF STEEL CONSTRUCTION & CODE OF <br />STANDARD PRACTICE. <br />2.STRUCTURAL STEEL DELIVERED TO THE JOB SITE SHALL BE FREE OF <br />EXCESSIVE RUST, MILL SCALE, GREASE, ETC. <br />3.STRUCTURAL STEEL MEMBERS SHALL CONFORM TO THE FOLLOWING <br />MATERIAL SPECIFICATIONS: <br />WIDE FLANGE MEMBERS A-992 <br />STRUCTURAL TUBES A-500, GRADE B <br />STRUCTURAL PIPES A-53, TYPE E OR S, GRADE B <br />ALL OTHER SHAPES A-36 <br />4.STRUCTURAL STEEL SHAPES & RODS SHALL CONFORM TO THE FOLLOWING <br />MATERIAL SPECIFICATIONS: <br />HOLD-DOWN RODS A-36 OR F-1554, GRADE 36 <br />HIGH STRENGTH HD RODS A-193 B7 OR F-1554, GRADE 105 <br />STANDARD STRENGTH BOLTS A-325 <br />HIGH STRENGTH BOLTS A-490 <br />MF BASE PLATES A-572 (fy=50 ksi) <br />5.STRUCTURAL STEEL DELIVERED TO THE JOB SITE SHALL NOT BE BENT OR <br />DAMAGED AND SHALL BE FREE OF EXCESSIVE RUST, MILL SCALE, GREASE, <br />ETC. <br />6.ALL STEEL FABRICATION SHALL BE PERFORMED IN A SHOP APPROVED BY THE <br />LOCAL JURISDICTION. SHOPDRAWINGS SHALL CONTAIN ALL INFORMATION <br />NECESSARY FOR ALL STRUCTURAL STEEL ERECTION INDEPENDENTLY OF & <br />WITHOUT RELIANCE ON THE STRUCTURAL PLANS & DETAIL. <br />7.USE NELSON STUDS FOR ALL STUD ANCHORS SHALL BE NELSON. INSTALL IN <br />ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. USE ½" Ø <br />STUDS AT 32" O.C. MAX WHERE REQUIRED FOR ARCHITECTURAL FINISHES / <br />NON-STRUCTURAL ELEMENTS ATTACHMENT. <br />8.INSTALLATION AND INSPECTION OF HIGH STRENGTH BOLTS SHALL CONFORM <br />TO THE REQUIREMENT OF THE AISC SPECIFICATIONS FOR STRUCTURAL <br />JOINTS. ASSEMBLE ALL ELEMENTS WITH HARDENED WASHERS UNDER THE <br />NUT OR BOLT HEAD. <br />9.WHERE HIGH STRENGTH BOLTS ARE USED, CONNECTIONS, HOLES, & <br />ELEMENTS SHALL BE FREE OF DIRT, SAND, BURRS, PITS, PAINT, OIL, LACQUER, <br />GALVANIZING, AND OTHER MATERIALS WHICH PREVENT ADEQUATE SEATING & <br />TIGHTENING. <br />10.ARCHITECTURALLY EXPOSED STRUCTURAL STEEL (AESS) SHALL CONFORM TO <br />THE AISC CODE OF STANDARD PRACTICE. REFER TO THE ARCHITECTURAL <br />DRAWINGS FOR LOCATIONS AND ADDITIONAL APPEARANCE AND TOLERANCE <br />REQUIREMENTS. <br />11.GRIND SMOOTH ALL EXPOSED WELDS AS APPROVED BY THE ARCHITECT & <br />REMOVE ALL TEMPORARY ERECTION CLIPS <br />12.ALL STEEL SHALL RECEIVE ONE COAT OF RUST INHIBITIVE PRIMER UNLESS <br />FIREPROOFED & INDICATED OTHERWISE ON THE ARCHITECTURAL DRAWINGS <br />OR SPECIFICATIONS. <br />13.ALL STEEL EXPOSED TO THE WEATHER SHALL BE HOT-DIPPED GALVANIZED <br />AFTER FABRICATION UNLESS ALTERNATE METHODS OF WEATHER PROOFING <br />ARE PROVIDED BY THE ARCHITECT. <br />14.PENETRATIONS ARE NOT ALLOWED IN STEEL MEMBERS UNLESS NOTED <br />OTHERWISE ON THE PLANS & APPROVED BY THE EOR. SHORE STEEL <br />MEMBERS WHEN PERMISSIBLE HOLES ARE CUT WITH A TORCH AFTER STEEL IS <br />ERECTED. SHORING SHALL REMAIN UNTIL STEEL TEMPERATURE HAS <br />RETURNED TO AIR TEMPERATURE. <br />15.ALL EXPOSED ENDS OF STEEL MEMBERS SHALL BE CAPPED WITH A ¼" END <br />PLATE UNLESS NOTED OTHERWISE ON THE ARCHITECTURAL DRAWINGS. <br />16.ALL GROUT UNDER BASE PLATES SHALL BE HIGH STRENGTH (5,000 PSI MIN) <br />SOLID DRY PACK OR NON-SHRINK GROUT PLACED AS DIRECTED BY THE <br />MANUFACTURER. <br />GLUE LAMINATED BEAMS - GLB <br />1.SHALL BE 24F-V4 FOR SIMPLE SPANS AND 24F V8 FOR BEAMS WITH CANTILEVERS <br />WITH THE FOLLOWING MINIMUM PROPERTIES: <br />Fb 2400 PSI <br />Fv 165 PSI <br />FC,perp 650 PSI <br />E 1,800 KSI <br />2.SHALL HAVE EXTERIOR GLUE AND WEATHER TREATMENT PRIOR TO INSTALLATION <br />3.SHALL BE FABRICATED BY AN APPROVED MANUF. <br />4.AN A.I.T.C. CERTIFICATE OF COMPLIANCE SHALL BE GIVEN TO THE BUILDING <br />INSPECTOR PRIOR TO INSTALLATION <br />5.SHALL HAVE FACTORY STANDARD CAMBER, EXCEPT WHERE NOTED OTHERWISE <br />ON THE PLANS <br />CONCRETE MASONRY <br />1.ALL MASONRY WORK SHALL BE CONTINUOUSLY INSPECTED. <br />2.MORTAR SHALL BE TYPE M OR S CONFORMING TO ASTM C270. <br />3.GROUT SHALL CONFORM TO ASTM C476 OR ASTM C1019. <br />4.CMU SHALL BE MEDIUM WEIGHT CONFORMING TO ASTM C90. <br />5.MIN. STRENGTH OF MASONRY UNITS, MORTAR AND GROUT AT 28 DAYS SHALL BE: <br />5.1.f'm 1,500 PSI <br />5.2.MASONRY UNIT 1,900 PSI <br />5.3.MORTAR (TYPE M OR S)2,500 PSI <br />5.4.GROUT 2,000 PSI <br />6.COMPLIANCE WITH THE REQUIREMENTS FOR MINIMUM STRENGTH OF MASONRY UNITS <br />SHALL BE IN ACCORDANCE WITH ASTM C90 UNIT STRENGTH METHOD USING FULL <br />STRESSES IN DESIGN AND COMPRESSIVE STRENGTH. ALTERNATIVELY, A PRISM TEST <br />METHOD OR PRISM TEST RECORD METHOD MAY BE USED PER ASTM C1314 AND <br />APPROVED BY THE EOR <br />7.WHERE f'm > 1500 PSI, MASONRY PRISM TESTING IS REQUIRED PER ASTM C1314. <br />8.PLASTIC CEMENT AND MASONRY CEMENT SHALL NOT BE USED IN ANY CMU WALL <br />ASSEMBLY MIX DESIGNS. <br />9.MORTAR SHALL BE TESTED IN ACCORDANCE WITH ASTM C270. <br />10.GROUT SHALL BE TESTED IN ACCORDANCE WITH ASTM C476. <br />11.GROUT MIX DESIGN SHALL BE PERFORMED BY A RECOGNIZED TESTING LAB AND <br />REVIEWED BY THE EOR PRIOR TO START CONSTRUCTION. <br />12.GROUT SHALL CONSIST OF MIXTURE OF CEMENTICIOUS MATERIALS AND AGGREGATE <br />TO WHICH POTABLE WATER IS ADDED SUCH THAT THE MIXTURE WILL FLOW WITHOUT <br />SEGREGATION OF THE CONSTITUENTS. <br />13.GROUT ALL CELLS WITH REINFORCEMENT AND BELOW GRADE, TYPICAL UNO. <br />14.VERTICAL CELLS TO BE REINFORCED AND OR GROUTED SHALL HAVE VERTICAL <br />ALIGNMENT AND SHALL BE CLEAR OF OVERHANGING MORTAR, DEBRIS OR OTHER <br />OBSTRUCTIONS. <br />15.ALL HORIZONTAL REINFORCING BARS SHALL BE PLACED IN BOND BEAM UNITS. <br />16.PROVIDE 1/2" MINIMUM CLEAR SPACE BETWEEN REINFORCING BARS AND THE <br />MASONRY UNIT WALLS. <br />17.COLD JOINTS IN CMU WALLS NOT PERMITTED EXCEPT WHERE SPECIFIED. <br />18.HEIGHT OF GROUT POURS SHALL NOT EXCEED THAT SHOWN IN THE TMS <br />SPECIFICATION. <br />19.A HORIZONTAL CONSTRUCTION JOINT SHALL BE FORMED BETWEEN GROUT POURS BY <br />STOPPING GROUT A MINIMUM OF 1.5" BELOW A MORTAR JOINT, WHERE BOND BEAMS <br />OCCUR. GROUT POUR SHALL BE STOPPED A MINIMUM OF 1/2" BELOW THE TOP OF <br />MASONRY WEBS. <br />20.DURING PLACING, GROUT SHALL BE CONSOLIDATED BY MECHANICAL VIBRATIONS <br />BEFORE LOSS OF PLASTICITY SUCH AS TO FILL THE GROUT SPACE AND SHALL BE <br />RE-CONSOLIDATED BY MECHANICAL VIBRATION AFTER INITIAL WATER LOSS AND <br />SETTLEMENT HAS OCCURRED. <br />21.REFER TO ARCHITECTURAL DRAWINGS FOR MASONRY UNITS, JOINT TYPE, AND LAYING <br />PATTERN. <br />22.CONSTRUCTION SHALL COMPLY WITH SECTION 2104 OF 2022 CBC. <br />(A) REINFORCEMENT SHALL BE SECURED USING WIRE GUIDES (POSITIONING DEVICE) <br />TO PREVENT DISPLACEMENT DUE TO CONSTRUCTION LOADS OR BY GROUT/MORTAR <br />PLACEMENT. <br />(B) CLEANOUTS SHALL BE PROVIDED FOR ALL GROUT POURS OVER 5'-4". <br />(C) GROUT LIFTS SHALL NOT EXCEED 5'-4". <br />23.QUALITY ASSURANCE MEASURES, SHALL COMPLY WITH TMS /ACI /ASCE. <br />(A) FIVE MASONRY PRISM TESTS SHALL BE BUILT AND TESTED PRIOR TO <br />CONSTRUCTION. <br />(B) 3 MASONRY PRISM TESTS (PER 5000 SQ FT OF FLOOR AREA,3 MIN) SHALL BE BUILT <br />& TESTED DURING CONST. WHEN FULL STRESSES ARE USED IN DESIGN. <br />REINFORCING STEEL <br />1.REINFORCING STEEL FOR #4 BARS AND LARGER SHALL CONFORM TO ASTM A615 <br />OR ASTM A706 (GRADE 60). <br />2.REINFORCEMENT IN SHEAR WALLS AND MOMENT FRAMES SHALL COMPLY WITH <br />ASTM A706. ASTM A615 (GRADE 60) SHALL BE PERMITTED IN THESE MEMBERS <br />ONLY IF: <br />2.1.MINIMUM ELONGATIONS IN 8 INCHES IS AT LEAST 14% FOR BAR SIZES #3 <br />THROUGH #6, AT LEAST 12% FOR BAR SIZES #7 THROUGH #11, AND AT LEAST <br />10 % FOR BAR SIZES #14 OR LARGER. <br />2.2.ACTUAL YIELD STRENGTH BASED ON MILL TESTS DOES NOT EXCEED 78,000 <br />PSI WITH RETESTS NOT EXCEEDING 81,000 PSI. <br />3.WELDED WIRE MESH / FABRIC SHALL CONFORM TO ASTM A1064 (GRADE 65) AND <br />BE LAPPED 1.5 SPACES (12" MINIMUM) FOR PLAIN WIRE AND ASTM A1064 (GRADE <br />75) FOR DEFORMED BAR. <br />4.REINFORCING STEEL TO BE WELDED SHALL CONFORM TO ASTM A706 (GRADE 60). <br />5.CHAIRS OR SPACERS FOR REINFORCING SHALL BE PLASTIC OR PLASTIC COATED <br />WHEN RESTING ON EXPOSED SURFACES. <br />WOOD FRAMING <br />1.ALL STRUCTURAL FRAMING LUMBER SHALL CONFORM TO GRADES AS SET BY THE <br />W.C.L.I.B & THE CALIFORNIA BUILDING CODE & SHALL HAVE GRADE STAMP MARKED <br />BY AN APPROVED TESTING AGENCY. <br />2.ALL LUMBER SHALL HAVE 19% MAXIMUM MOISTURE CONTENT PRIOR ENCLOSING <br />THE FRAMING SYSTEMS (ROOFS, FLOORS, WALLS, ETC.). <br />3.All STRUCTURAL SAWN LUMBER SHALL BE DOUGLAS FIR-LARCH OF THE FOLLOWING <br />GRADES, UNLESS NOTED OTHERWISE: <br />2X SILL PLATES PRESSURE TREATED DOUG FIR (P.T.D.F.) <br />3X SILL PLATES PRESSURE TREATED DOUG FIR (P.T.D.F.) <br />2X4 STUDS DF NO. 2 <br />3X STUDS DF NO. 2 <br />2X6 TO 2X14 DF NO. 2 <br />4X12 AND SMALLER DF NO. 2 <br />4X14 & LARGER DF NO. 1 <br />6X & 8X DF NO. 1 <br />4.ALL STRUCTURAL SHEATHING, PLYWOOD OR OSB, SHALL BE IDENTIFIED WITH THE <br />GRADE TRADEMARK OF APA AND SHALL MEET THE PRODUCT STANDARD PS 1-09, <br />PS2-10, OR APA PRP 108. <br />5.ALL STRUCTURAL SHEATHING FULLY OR PARTIALLY EXPOSED TO WEATHER <br />PERMANENTLY SHALL BE EXTERIOR TYPE. <br />6.SHEATHING SPAN RATING SHALL EQUAL OR EXCEED THE SPACING OF THE <br />SUPPORTING FRAMING MEMBERS. <br />7.DO NOT UTILIZE PANELS WITH EITHER DIMENSION LESS THAN 24" FOR STRUCTURAL. <br />8.TYPICAL FLOOR/DECK SHEATHING (SEE 15/SD4 FOR ADDITIONAL REQUIREMENTS): <br />23 32" APA RATED STURD-I-FLOOR T&G EXP I WITH MINIMUM SPAN RATING OF 24" O.C. <br />REFER TO NER 108 FOR INSTALLATION AND CONDITIONS OF USE. USE 10d COMMON <br />NAILS OR 10d RING SHANK/SCREW SHANK AND GLUE SHEATHING TO FRAMING USING <br />ADHESIVES MEETING APA SPECIFICATION AFG-01 OR ASTM D3498. APPLY GLUE IN <br />ACCORDANCE WITH MANUFACTURERS'S SPECIFICATIONS. #8 X 2" LONG WOOD <br />SCREWS (2.5" AT 118" SHEATHING) IN ACCORDANCE WITH ER-5053 BY QUICK DRIVE <br />USE, INC. MAY BE SUBSTITUTED FOR THE 10d COMMON NAILS. <br />BOUNDARY NAIL (BN) 10d COMMON NAILS AT 6" O.C. <br />EDGE NAILING (EN)10d COMMON NAILS AT 6" O.C. <br />FIELD NAILING (FN) 10d COMMON NAILS AT 12" O.C. <br />9.TYPICAL ROOF SHEATHING (SEE 15/SD4 FOR ADDITIONAL REQUIREMENTS): <br />15 32" APA RATED SHEATHING EXP I WITH MINIMUM PANEL INDEX OF 32/16. REFER TO <br />NER 108 FOR INSTALLATION AND CONDITIONS OF USE. USE 8d COMMON NAILS U.N.O. <br />USE 10d AT BLOCKED ROOF DIAPHRAGMS. ALL EDGES TO BE BLOCKED ROOFS <br />WHERE SLOPE < 1:12. <br />BOUNDARY NAIL (BN) 8d COMMON NAILS AT 6" O.C. <br />EDGE NAILING (EN)8d COMMON NAILS AT 6" O.C. <br />FIELD NAILING (FN) 8d COMMON NAILS AT 12" O.C. <br />10.PROVIDE 18" GAP BETWEEN PANEL EDGES. <br />11.ALL MACHINE BOLTS SHALL CONFORM TO ASTM A307. HOLES FOR BOLTS SHOULD BE <br />DRILLED 116" LARGER THAN BOLT DIAMETER. <br />12.FOR NON-SHEAR WALL APPLICATION, ROUND WASHERS SHALL BE USED ON ALL <br />BOLTS AND SHOULD CONFORM WITH ANSI/ASME B 18.22.1 USE MIN 1 3 8"Ø X 7 64" THICK <br />WASHER FOR 12"Ø BOLT, 1 3 4"Ø X 9 64" THICK WASHER FOR 5 8"Ø BOLT <br />AND 2 12"Ø X 1164" THICK WASHER 1"Ø BOLT, U.N.O. <br />13.ALL NAILS SHALL BE SINKERS AND STAGGERED U.N.O., EXCEPT AS SHOWN ON <br />NAILING SCHEDULE. <br />14.ADHESIVE USED TO ATTACH FLOOR SHEATHING TO FRAMING ELEMENTS SHALL <br />CONFORM WITH APA SPECIFICATION AFG-01. <br />15.MANUFACTURED HARDWARE SPECIFIED ON THE DRAWINGS ARE TO BE SIMPSON <br />STRONG TIE (UNLESS SPECIFICALLY AUTHORIZED IN WRITING BY EOR). FOLLOW ALL <br />MANUFACTURER'S REQUIREMENTS AND RECOMMENDATIONS FOR INSTALLATION <br />AND HANDLING OF THE PRODUCT. <br />16.ALL FRAMING, BRACING, NAILING, NOTCHING, DRILLING OR BORING SHALL BE IN <br />ACCORDANCE WITH BUILDING CODES UNLESS MORE STRINGENT REQUIREMENTS <br />ARE SPECIFIED OR REQUIRED BY THE LOCAL JURISDICTION. <br />17.FABRICATION AND HANDLING OF GLU-LAM BEAMS SHALL BE PER ANSI/AITC A 190.1. <br />STANDARD BEAMS TO BEAR LEGIBLE APA-ENS OR AITC GRADE STAMP. AN APA- EWS <br />CRAN AITC CERTIFICATE OF CONFORMANCE FOR GLUE-LAMINATED MEMBERS <br />SHOULD BE SUBMITTED TO THE FIELD INSPECTOR PRIOR TO INSTALLATION AND <br />GLU-LAM MEMBERS SHALL BE 25F-V4, DF/DF WITH THE STANDARD CAMBER ON ROOF <br />BEAMS EXCEPT CANTILEVER END, U.N.O. ALL CANTILEVER ENDS AND FLOOR BEAMS <br />SHALL HAVE NO CAMBER U.N.O. ALL BEAMS SHALL BE FABRICATED WITH <br />WATERPROOF GLUE. <br />18.FASTENERS IN CONTACT WITH PRESERVATIVE TREATED LUMBER AND FIRE <br />RETARDANT TREATED WOOD SHALL BE OF HOT DIPPED ZINC-COATED GALVANIZED <br />STEEL, STAINLESS STEEL, SILICON BRONZE OR COPPER. EXCEPTION: PLAIN CARBON <br />STEEL FASTENERS IN SBX/DOT AND ZINC BORATE PRESERVATIVE-TREATED WOOD IN <br />AN INTERIOR, DRY ENVIRONMENT SHALL BE PERMITTED. <br />19.STUD WALLS PERPENDICULAR TO A CONCRETE OR MASONRY WALL SHALL BE <br />BOLTED TO THE CONCRETE OR MASONRY WALL WITH 5 8"Ø X 8" A307 BOLTS AT <br />TOP, MID-HEIGHT AND BOTTOM. <br />20.STRUCTURAL INFORMATION SHOWN ON FRAMING PLANS IS FOR THE MAIN <br />STRUCTURAL ELEMENTS. NON-STRUCTURAL ELEMENTS SHALL BE CONSTRUCTED <br />PER APPROVED CODE REQUIREMENTS. <br />21.CONVENTIONAL LIGHT FRAMED CONSTRUCTION REQUIREMENTS OF CHAPTER 23 <br />SHOULD BE FOLLOWED AS REQUIRED. <br />22.TOP PLATES OF ALL WOOD STUD WALLS TO CONSIST OF (2) 2X'S THE SAME WIDTH AS <br />THE STUDS, UNO. TOP PLATES SHALL LAP A MINIMUM OF 48" AND BE SPLICED WITH <br />NOT LESS THAN 6-16d NAILS SPACED NOT MORE THAN 12" O.C. <br />23.ALL SHEAR PANELS SHALL HAVE CONTINUOUS SHEATHING MATERIAL FROM ONE END <br />TO THE OTHER AND FROM PLATE TO PLATE AS SPECIFIED ON THE DRAWINGS. <br />CONTRACTOR SHALL COORDINATE FRAMING SUCH THAT CONTINUITY OF SHEAR <br />PANELS IS ASSURED. <br />24.ALL SHEAR TRANSFER NAILING SHALL BE PER PLAN, AND CONTRACTOR SHALL <br />PROVIDE PROPER NOTIFICATION FOR INSPECTIONS TO REVIEW THE SAME. <br />25.PROVIDE POST/MULTIPLE STUDS AT LOWER FLOOR UNDER POST/MULTIPLE STUDS <br />ABOVE. EACH POST/STUD SHALL BE FASTENED BY GYPSUM WALL BOARD WITH 5d <br />COOLER NAILS AT 6" O.C., U.N.O. ON PLAN. PROVIDE FULL WIDTH AND DEPTH <br />COMPRESSION BLOCK BETWEEN FLOORS AT SUCH LOCATIONS. <br />26.IF DOUBLE SILL PLATE IS USED AS LIGHT-WEIGHT CONCRETE FLOORING, THEN THE <br />FRAMING CONTRACTOR SHALL APPLY SILL PLATE NAILING TO BOTH SILL PLATES, AT <br />16" O.C. MAX. OR AS SPECIFIED PER SCHEDULE. <br />HANGERS <br />1.HANGERS SHALL BE AS SPECIFIED BELOW, UNO ON THE FRAMING PLANS. <br />1.1.FOR I-JOIST TO BEAM/LEDGER/RIM CONNX: USE ITS HANGERS OR EQUIVALENT. <br />BEND TABS DOWN TO TOP OF BOTTOM CHORD WHERE APPLICABLE. <br />1.2.FOR 2X JOIST TO BEAM/LEDGER/RIM CONNX: USE LUS FULL DEPTH HANGERS. <br />1.3.FOR BEAM TO BEAM CONNX: USE HU MAX FULL DEPTH HANGERS. <br />1.4.FOR 2X JOIST OR ROOF TRUSSES AT 24" O.C. (OR LESS) TO BEAM/LEDGER/RIM <br />CONNECTIONS USE HANGERS PER TABLE BELOW: <br />SPAN HANGER <br />LESS THAN 15'LUS 26 <br />LESS THAN 20'LUS 28 <br />LESS THAN 30'HUS 26 <br />TABLE ABOVE DO NOT USE ON GIRDER TRUSS. REFER TO TRUSS MANUF. <br />PLACEMENT PLAN. <br />2.AT ALL HANGERS, FILL ALL NAIL HOLES, INCLUDING TRIANGULAR HOLES. <br />3.USE SKEWED HANGERS WHERE JOISTS OR BEAM ARE NOT PERPENDICULAR TO <br />SUPPORTING MEMBER. <br />ENGINEERED LUMBER <br />LSL - LAMINATED STRAND LUMBER <br />1.11 <br />2" LSL RIM BOARD SHALL HAVE THE FOLLOWING MIN. PROPERTIES: <br />Fb 1,700 PSI <br />Fv 425 PSI <br />FC,perp 710 PSI <br />E 1,300 KSI <br />2.13 <br />4 " LSL MEMBERS SHALL HAVE THE FOLLOWING MIN. PROPERTIES: <br />Fb 2,325 PSI <br />Fv 310 PSI <br />FC,perp 900 PSI <br />E 1,550 KSI <br />3.SHALL BE FABRICATED BY AN APPROVED MANUF.: TRUSJOIST (ICC ESR 1387). <br />4.SHALL BE, WHEN COMPRISED OF MULTIPLE MEMBERS, CONNECTED WITH 16d <br />NAILS OR STRUCTURAL SCREWS IN ACCORDANCE WITH THE MANUFACTURER'S <br />SPECIFICATIONS OR STRUCTURAL DETAILS. <br />LVL - LAMINATED VENEER LUMBER <br />5.SHALL BE 13 <br />4" MIN. WIDTH WITH THE FOLLOWING MIN. PROPERTIES: <br />Fb 2600 PSI <br />Fv 285 PSI <br />FCperp 750 PSI <br />E 1,900 KS <br />6.SHALL BE FABRICATED BY AN APPROVED MANUF.: TRUSJOIST (ICC ESR 1387), <br />BOISE CASCADE (ICC ESR 1040), OR LOUISIANA PACIFIC (ICC ESR 1254) <br />7.SHALL BE, WHEN COMPRISED OF MULTIPLE MEMBERS, CONNECTED WITH 16d <br />NAILS OR STRUCTURAL SCREWS IN ACCORDANCE WITH THE MANUFACTURER'S <br />SPECIFICATIONS OR STRUCTURAL DETAILS. <br />PSL - PARALLEL STRAND LUMBER <br />8.SHALL BE 31 <br />2" MIN. WIDTH WITH THE FOLLOWING MIN. PROPERTIES: <br />Fb 2900 PSI <br />Fv 290 PSI <br />Fcperp 750 PSI <br />E 2,200 KSI <br />9.SHALL BE FABRICATED BY AN APPROVED MANUF.: TRUSJOIST (ICC ESR 1387) <br />NAILING SCHEDULE 2022 CBC TABLE 2304.10.1 <br />DESCRIPTION OF BUILDING ELEMENTS NUMBER AND TYPE OF FASTENER <br />ROOF <br />3-8d common (21/2″ × 0.131″); <br />or 3-10d box (3″ × 0.128″); <br />or 3-3″ × 0.131″ nails; <br />or 3-3″14 gage staples, 7/16″ crown <br />2-8d common (21/2″ × 0.131″) <br />Each end, toenail <br />2-3″ × 0.131″ nails 2-3″ 14 gage staples <br />2-16 d common (31/2″ × 0.162″) <br />End nail <br />3-3″ × 0.131″ nails 3-3″ 14 gage staples <br />16d common (31/2″ × 0.162″) @ 6″ o.c. <br />3″ × 0.131″ nails @ 6″ o.c. 3″ × 14 gage staples @ 6″ o.c <br />3-8d common (21/2″ × 0.131″); or <br />3-10d box (3″ × 0.128″); or 3-3″ × 0.131″ nails; or <br />3-3″ 14 gage staples, 7/16″ crown <br />3-16d common (31/2″ × 0.162″); or <br />4-10d box (3″ × 0.128″); or 4-3″ × 0.131″ nails; or <br />4-3″ 14 gage staples, 7/16″ crown <br />Per Table 2308.7.3.1 <br />3-10d common (3″ × 0.148″); or <br />4-10d box (3″ × 0.128″); or 4-3″ × 0.131″ nails; or <br />4-3″ 14 gage staples, 7/16″ crown <br />3-10 common (3″ × 0.148″); <br />or 3-16d box (31/2″ × 0.135″); <br />or 4-10d box (3″ × 0.128″); <br />or 4-3″ × 0.131 nails; <br />or 4-3″ 14 gage staples, 7/16″ crown <br />2-16d common (31/2″ × 0.162″); <br />or 3-10d box (3″ × 0.128″); <br />or 3-3″ × 0.131″ nails; <br />or 3-3″ 14 gage staples, 7/16″ crown; or <br />3-10d common (3″ × 0.148″); <br />or 4-16d box (31/2″ × 0.135″); <br />or 4-10d box (3″ × 0.128″); or 4-3″ × 0.131″ nails; <br />or 4-3″ 14 gage staples, 7/16″ crown <br />WALL <br />16d common (31/2″ × 0.162″); <br />10d box (3″ × 0.128″); or <br />4-10d box (3″ × 0.128″) <br />16d common (31/2″ × 0.162″); or <br />10d box (3″ × 0.128″); or <br />3″ × 0.131″ nails; or 3″ 14 gage staples, 7/16″ crown <br />8-16d common (31/2″ × 0.162″); or <br />12-10d box (3″ × 0.128″); or 12-3″ × 0.131″ nails; or <br />12-3″ 14 gage staples, 7/16″ crown <br />16d common (31/2″ × 0.162″); or <br />16d box (31/2″ × 0.135″); or <br />3″ × 0.131″ nails; or 3″ 14 gage staples, 7/16″ crown <br />2-16d common (31/2″ × 0.162″); or <br />3-16d box (31/2″ × 0.135″); or 4-3″ × 0.131″ nails; or <br />4-3″ 14 gage staples, 7/16″ crown <br />4-8d common (21/2″ × 0.131″); or <br />4-10d box (3″ × 0.128″); or 4-3″ × 0.131″ nails; or <br />4-3″ 14 gage staples, 7/16″ crown; or <br />2-16d common (31/2″ × 0.162″); or <br />3-10d box (3″ × 0.128″); or 3-3″ × 0.131″ nails; or <br />3-3″ 14 gage staples, 7/16″ crown <br />2-16d common (31/2″ × 0.162″); or <br />3-10d box (3″ × 0.128″); or 3-3″ × 0.131″ nails; or <br />3-3″ 14 gage staples, 7/16″ crown <br />2-8d common (21/2″ × 0.131″); or <br />2-10d box (3″ × 0.128″); or 2-3″ × 0.131″ nails; or <br />2-3″ 14 gage staples, 7/16″ crown <br />2-8d common (21/2″ × 0.131″); or <br />2-10d box (3″ × 0.128″) <br />3-8d common (21/2″ × 0.131″); or <br />3-10d box (3″ × 0.128″) <br />FLOOR <br />3-8d common (21/2″ × 0.131″); or floor <br />3-10d box (3″ × 0.128″); or3-3″ × 0.131″ nails; or <br />3-3″ 14 gage staples, 7/16″ crown <br />8d common (21/2″ × 0.131″); or <br />10d box (3″ × 0.128″); or 3″ × 0.131″ nails; or <br />3″ 14 gage staples, 7/16″ crown <br />2-8d common (21/2″ × 0.131″); or <br />2-10d box (3″ × 0.128″) <br />2-16d common (31/2″ × 0.162″) <br />2-16d common (31/2″ × 0.162″) <br />20d common (4″ × 0.192″) <br />10d box (3″ × 0.128″); or <br />3″ × 0.131″ nails; or 3″ 14 gage staples, 7/16″ crown <br />And: <br />2-20d common (4″ × 0.192″); or 3-10d box (3″ × 0.128″); or <br />3-3″ × 0.131″ nails; or 3-3″ 14 gage staples, 7/16″ crown <br />3-16d common (31/2″ × 0.162″); or <br />4-10d box (3″ × 0.128″); or 4-3″ × 0.131″ nails; or <br />4-3″ 14 gage staples, 7/16″ crown <br />3-16d common (31/2″ × 0.162″); or <br />4-10d box (3″ × 0.128″); or 4-3″ × 0.131″ nails; or <br />4-3″ 14 gage staples, 7/16″ crown <br />2-8d common (21/2″ × 0.131″); or <br />2-10d box (3″ × 0.128″); or 2-3″ × 0.131″ nails; or <br />2-3″ 14 gage staples, 7/16″ crown <br />Toenail <br />Face nail <br />Face nail <br />3″ × 0.131″ nails; or 3-3″ 14 gage staples, 7/16″ crown <br />16d common (31/2″ × 0.162″); or <br />16d box (31/2″ × 0.135″); or <br />3″ × 0.131″ nails; or <br />3-3″ 14 gage staples, 7/16″ crown <br />16d common (31/2″ × 0.162″); or <br />16d box (31/2″ × 0.135″) <br />4-8d common (21/2″ × 0.131″); or <br />Toenail <br />16″ o.c. face nail <br />12″ o.c. face nail <br />Each side of end joint, face nail (minimum <br />24" lap splice length each side of end <br />joint) <br />16″ o.c. face nail <br />12″ o.c. face nail <br />24″ o.c. face nail <br />16″ o.c. face nail <br />12″ o.c. face nail <br />12″ o.c. face nail <br />16″ o.c. each edge, face nail <br />12″ o.c. each edge, face nail <br />Face nail <br />SPACING AND LOCATION <br />Each end, toenail <br />Each joist, toenail <br />Face nail <br />Face nail <br />Face nail <br />Toenailc <br />End nail <br />Toenail <br />16″ o.c. face nail <br />Toenail <br />End nail <br />Face nail <br />Face nail <br />6″ o.c., toenail <br />Face nail <br />Face nail <br />Each bearing, face nail <br />32″ o.c., face nail at top and bottom <br />staggered on opposite sides <br />24″ o.c. face nail at top and bottom <br />staggered on opposite sides <br />Ends and at each splice, face nail <br />Each joist or rafter, face nail <br />End nail <br />Each end, toenail <br />1.Blocking between ceiling joists, rafters or trusses to <br />top plate or other framing below <br />3.Ceiling joist not attached to parallel rafter,laps <br />over partitions (no thrust) [see Section <br />2308.7.3.1, Table 2308.7.3.1] <br />4.Ceiling joist attached to parallel rafter (heel joint) [see <br />Section 2308.7.3.1, Table 2308.7.3.1] <br />6.Rafter or roof truss to top plate [see Section <br />2308.7.5, Table 2308.7.5] <br />7.Roof rafters to ridge valley or hip rafters; or roof rafter <br />to 2-inch ridge beam <br />9.Stud to stud and abutting studs at intersecting <br />wall corners (at braced wall panels) <br />29.Bridging or blocking to joist, rafter or truss <br />28.Joist to band joist or rim joist <br />27.Ledger strip supporting joists or rafters <br />26.Built-up girders and beams, 2″ lumber layers <br />2.Ceiling joists to top plate <br />Flat blocking to truss and web filler <br />8.Stud to stud (not at braced wall panels) <br />10.Built-up header (2″ to 2″ header) <br />11.Continuous header to stud <br />12.Top plate to top plate <br />13.Top plate to top plate, at end joints <br />14.Bottom plate to joist, rim joist, band joist or <br />blocking (not at braced wall panels) <br />15.Bottom plate to joist, rim joist, band joist or blocking <br />at braced wall panels <br />16.Stud to top or bottom plate <br />17.Top plates, laps at corners and intersections <br />18.1″ brace to each stud and plate <br />19.1″ × 6″ sheathing to each bearing <br />20.1″ × 8″ and wider sheathing to each bearing <br />21.Joist to sill, top plate, or girder <br />22.Rim joist, band joist, or blocking to top plate, sill <br />or other framing below <br />23.1″ × 6″ subfloor or less to each joist <br />24.2 subfloor to joist or girder <br />25.2″ planks (plank & beam – floor & roof) <br />Blocking between rafters or truss not at the wall top plate, <br />to rafter or truss <br />5.Collar tie to rafter <br />FASTNERS <br />NAILS <br />1.NAILS SHALL BE "COMMON" NAILS UNLESS NOTED OTHERWISE (UNO). <br />2.NAILS SHALL NOT BE DRIVEN CLOSER THAN 12 THEIR LENGTH TO ANOTHER NAIL <br />NOR CLOSER THAN 14 OF THEIR LENGTH TO THE EDGE OR END OF A MEMBER, <br />EXCEPT FOR SHEATHING. <br />3.NAILS SHALL BE INSTALLED IN PRE-DRILLED LEAD HOLES IF NECESSARY TO <br />AVOID SPLITTING. <br />4.NAILS IN CONTACT WITH PRESERVATIVE-TREATED WOOD SHALL BE HOT-DIPPED <br />ZINC GALVANIZED OR STAINLESS STEEL. <br />5.ALL NAILING SHALL CONFORM TO 2022 CBC TABLE 2304.10.1 ABOVE <br />LAG SCREWS <br />6.LAG SCREWS SHALL BE INSTALLED INTO PRE-DRILLED LEAD HOLES. LUBRICANT <br />(OR SOAP) SHALL BE USED TO FACILITATE INSTALLATION AND PREVENT DAMAGE <br />TO THE SCREWS. <br />7.LAG SCREWS IN CONTACT WITH PRESERVATIVE-TREATED WOOD SHALL BE <br />HOT-DIPPED ZINC GALVANIZED OR STAINLESS STEEL. <br />BOLTS <br />8.BOLTS SHALL CONFORM TO ASTM F1554 GRADE 36 UNLESS NOTED OTHERWISE <br />(UNO) ON PLANS AND DETAILS. <br />9.BOLTS SHALL BE INSTALLED IN PRE-DRILLED HOLES WITH A MAXIMUM DIAMETER <br />OF 1/16” LARGER THAN THE SPECIFIED BOLT DIAMETER. <br />10.WHEN INSTALLED AGAINST WOOD SURFACES, BOLTS SHALL HAVE STANDARD <br />WASHERS UNDER THE HEADS AND NUTS. <br />11.BOLTS IN CONTACT WITH PRESERVATIVE-TREATED WOOD SHALL BE HOT-DIPPED <br />ZINC GALVANIZED OR STAINLESS STEEL. <br />ALL DRAWINGS & WRITTEN MATERIAL HEREIN CONSTITUTES THE <br />ENGINEER'S ORIGINAL WORK. THE SAME SHALL NOT BE DUPLICATED, <br />USED, OR SHARED WITHOUT THE EXPRESS WRITTEN CONSENT OF THE <br />ENGINEER. ESSE'S ALL RIGHTS RESERVED <br />947 E. FAIRWAY DRIVE, <br />ORANGE, CA 92866 <br />(714) 400 - 5584 <br />NO.DATE ISSUE <br />SHEET NO. <br />GA <br />R <br />F <br />I <br />E <br />L <br />D <br /> <br />R <br />E <br />S <br />T <br />O <br />R <br />A <br />T <br />I <br />O <br />N <br /> <br />/ <br /> <br />R <br />E <br />M <br />O <br />D <br />E <br />L <br />VV <br />S <br /> <br />E <br />S <br />T <br />A <br />T <br />E <br />S <br /> <br />L <br />L <br />C <br />82 <br />9 <br /> <br />N <br />. <br /> <br />G <br />A <br />R <br />F <br />I <br />E <br />L <br />D <br /> <br />S <br />T <br />R <br />E <br />E <br />T <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />1 <br />07-09-2024 <br />ELIE SAYEGH, PE <br />0127 <br /> <br /> <br />DOCUMENTS ORIGINAL ISSUE DATE: <br />PROJECT ENGINEER: <br />PROJECT NO. <br />1S <br />T <br /> <br />S <br />U <br />B <br />M <br />I <br />T <br />T <br />A <br />L <br />SN0 <br />ST <br />R <br />U <br />C <br />T <br />U <br />R <br />A <br />L <br /> <br />N <br />O <br />T <br />E <br />S <br />07/09/2024 <br />HOLD- 829 N <br />Garfield St1/15/2025