Laserfiche WebLink
ELECTRICAL PLAN - GROUND FLOOR <br />3#10, <br />#10GND- <br />3/4"C <br />UP <br />UP <br />R3 NO <br />N <br />- <br />A <br />C <br />C <br />E <br />S <br />S <br />D <br />3 <br />S/C <br />SD VS <br />VSS S <br />D 3 <br />R1-23 <br />R1-23 <br />R1-23 <br />R1-23 <br />R1-23 <br />R1-23 <br />PANEL <br />"R1" <br />D3 <br />D 3 <br />D <br /> <br />D <br />VS SS <br />PANEL <br />"R2" <br />S <br />S/C <br />R3-23 <br />R3-23 <br />R3-23 <br />R3-23 <br />R3-23 <br />R3-23 <br />PANEL <br />"R3" <br />PANEL <br />"R4" <br />D <br />D <br /> <br />S <br />D <br />VS SS <br />S/C <br />D3 D3 <br />D 3 D 3S <br />R5-23 <br />R5-23 <br />R5-23 <br />R5-23 <br />R5-23 <br />R5-23 <br />R5-23 <br />HP-3 <br />PANEL <br />"R5" <br />UNIT#2 <br />REFER TO ELECTRICAL LAYOUT UNIT#1 <br />UNIT#4 <br />REFER TO ELECTRICAL LAYOUT UNIT#3 <br />UNIT#1 <br />UNIT#3 <br />UNIT#5 <br />S <br />R1-1/3 <br />R1-5 <br />S M <br />J <br />R1-18 <br />R1-13 <br />R1-17 <br />R1-19 <br />R1-20 <br />R1-6 <br />R1-2 <br />+8"CT <br />+8"CT <br />R1-4 <br />1-1 <br />FC <br />1-2 <br />FC <br />1-1 <br />FC <br />1-2 <br />FC <br />J <br />J <br />R1-14/16 <br />R1-14/16 <br />#10 <br />#10 <br />R3-6 <br />R3-19 <br />+8"CT <br />R3-17R3-2 <br />R3-13 <br />R3-1/3 <br />S M <br />J <br />R3-18 <br />S <br />R3-5 <br />+8"CT <br />+8"CT <br />+8"CT+8"CT <br />R3-4 <br />R3-22 <br />J <br />R4-14/16 <br />#10 <br />J <br />R4-14/16 <br />#10 <br />R5-2 <br />J <br />R5-14/16 <br />#10 J <br />R5-14/16 <br />#10 <br />R5-13R5-1/3 <br />S M <br />J <br />R5-18 <br />S <br />R5-5 <br />R5-17 <br />+8"CT <br />+8"CT <br />+8"CT+8"CT <br />R5-4 R5-8 <br />R5-6 <br />+8"CT <br />R5-19 <br />WP <br />HP-4 (TYP.) <br />WH-1 <br />WH-2 <br />HP-5 <br />HP-9 <br />HP-2 <br />"MS" <br />PANEL <br />"HP" <br />KEYED ELECTRICAL PLAN NOTES: <br />1.VERIFY/COORDINATE EXACT LOCATION FOR ELECTRICAL EQUIPMENTS AND <br />PROVIDE/MAINTAIN MINIMUM CLEARANCE. [2022 CEC 110.26] <br />2.VERIFY EXACT ELECTRICAL INSTALLATION REQUIREMENTS WITH <br />MANUFACTURER AND PROVIDE PER RECOMMENDATION. <br />3.WIRE THROUGH PHOTOCELL AND MOTION SENSOR OR ASTRONOMICAL TIME <br />CLOCK FOR ALL EXTERIOR LIGHT FIXTURES. [2022 CENC 130.2(C)]. <br />4.PROVIDE GFI/WATERPROOF/WEATHER RESISTANT RECEPTACLE WITHIN <br />25FT OF HEATING, AC, AND REFRIGERATION EQUIPMENT. <br />5.REFER TO MECHANICAL PLAN AND HVAC SYSTEM CONNECTION SCHEDULE <br />FOR EXACT LOCATIONS, SPECS AND INSTALLATION REQUIREMENTS. <br />6.AN ELECTRICAL DISCONNECT SWITCH LABEL SHALL BE PERMANENTLY <br />AFFIXED, OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT <br />INVOLVED, AND NOT HANDWRITTEN. CEC 100, 110.22, 404.14 & 408.4(B). <br /># <br />1 <br />2 <br />(TYP.) <br />R1-11 <br />R3-9 R5-9 <br />HP-1 <br />HP-1 <br />HP-1 <br />3 <br />3 <br />3 <br />(TIE) <br />HP-4 <br />(TIE) <br />#8 <br />#8 #8 <br />R1-7 <br />UNIT#2 <br />REFER TO GARAGE UNIT#1 <br />UNIT#3 <br />REFER TO GARAGE UNIT#1 <br />UNIT#4 <br />REFER TO GARAGE UNIT#1 <br />UNIT#5 <br />REFER TO GARAGE UNIT#1 <br />UNIT#6 <br />REFER TO GARAGE UNIT#1 <br />UNIT#7 <br />REFER TO GARAGE UNIT#1 <br />UNIT#8 <br />REFER TO GARAGE UNIT#1 <br />UNIT#9 <br />REFER TO GARAGE UNIT#1 <br />UNIT#10 <br />REFER TO GARAGE UNIT#1 <br />TYP. GARAGE DOOR <br />GENERAL NOTES: <br />NOTES: <br />REFER TO MECHANICAL PLAN FOR HVAC SYSTEM INFO. VERIFY INSTALLATION REQUIREMENTS <br />WITH MANUFACTURER AND PROVIDE PER RECOMMENDATION. <br />GENERAL NOTES: <br />1.SMOKE ALARMS SHALL BE INSTALLED IN THE FOLLOWING LOCATIONS: <br />A.IN EACH SLEEPING ROOM. [2022 CRC R314.3(1)] <br />B.OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE <br />BEDROOMS [2022 CRC R314.3(2)] <br />C.ON EACH ADDITIONAL STORY OF THE DWELLING, INCLUDING BASEMENTS AND <br />HABITABLE ATTICS. [2022 CRC R314.3(3)] <br />D.INSTALLATION NEAR BATHROOMS. SMOKE ALARMS SHALL BE INSTALLED NOT LESS <br />THAN A 3 FOOT HORIZONTAL DISTANCE FROM THE DOOR OR OPENING OF A <br />BATHROOM THAT CONTAINS A BATHTUB OR SHOWER. [2022 CRC R314.3(5)] <br />E.SMOKE ALARMS OR SMOKE DETECTORS SHALL BE INSTALLED A MINIMUM OF 20 <br />FEET HORIZONTAL DISTANCE FROM A PERMANENTLY INSTALLED COOKING <br />APPLIANCE. [2022 CRC R314.3.3, NFPA72 29.9.3.4(4)] <br />F.SMOKE ALARMS AND SMOKE DETECTORS SHALL NOT BE INSTALLED WITHIN A 36 IN. <br />HORIZONTAL PATH FROM THE SUPPLY REGISTERS OF A FORCED AIR HEATING OR <br />COOLING SYSTEM AND SHALL BE INSTALLED OUTSIDE OF THE DIRECT AIRFLOW <br />FROM THOSE REGISTERS. [2022 CRC R314.3.3, NFPA72 29.9.3.4(6)] <br />2.CARBON MONOXIDE ALARMS SHALL BE INSTALLED IN THE FOLLOWING LOCATIONS: <br />A.OUTSIDE OF EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE <br />BEDROOMS.[2022 CRC R315.3(1)] <br />B.ON EVERY OCCUPIABLE LEVEL OF A DWELLING UNIT, INCLUDING BASEMENTS. [2022 <br />CRC R315.3(2)] <br />C.WHERE A FUEL-BURNING APPLIANCE IS LOCATED WITHIN A BEDROOM OR ITS <br />ATTACHED BATHROOM, A CARBON MONOXIDE ALARM SHALL BE INSTALLED WITHIN <br />THE BEDROOM. [2022 CRC R315.3(3)] <br />3.WHERE MORE THAN ONE SMOKE ALARM OR CARBON MONOXIDE ALARM IS REQUIRED <br />TO BE INSTALLED WITHIN AN INDIVIDUAL DWELLING OR SLEEPING UNIT, THE ALARMS <br />SHALL BE INTERCONNECTED IN SUCH A MANNER THAT THE ACTIVATION OF ONE <br />ALARM WILL ACTIVATE ALL OF THE ALARMS IN THE INDIVIDUAL UNIT. [2022 CRC R314.4, <br />R315.5] <br />4.SMOKE ALARMS AND CARBON MONOXIDE ALARMS SHALL RECEIVE THEIR PRIMARY <br />POWER FROM THE BUILDING WIRING AND SHALL BE EQUIPPED WITH A BATTERY <br />BACKUP. WIRING SHALL BE PERMANENT AND WITHOUT A DISCONNECTING SWITCH <br />OTHER THAN AS REQUIRED FOR OVERCURRENT PROTECTION. [2022 CRC R314.6, <br />R315.6] <br />5.SMOKE ALARMS AND CARBON MONOXIDE ALARMS SHALL BE LISTED IN ACCORDANCE <br />WITH UL 217. COMBINATION SMOKE AND CARBON MONOXIDE ALARMS SHALL BE <br />LISTED IN ACCORDANCE WITH UL 217 AND UL 2034. [2022 CRC R314.1.1, R315.1.1] <br />6.AFCI PROTECTION: ALL 120-VOLT, SINGLE-PHASE, 15- AND 20-AMPERE BRANCH <br />CIRCUITS SUPPLYING OUTLETS OR DEVICES INSTALLED IN DWELLING UNIT KITCHENS, <br />FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, BEDROOMS, <br />CLOSETS, HALLWAYS, LAUNDRY AREAS, OR SIMILAR ROOMS OR AREAS SHALL BE AFCI <br />PROTECTED. [2022 CEC 210.12(A)] <br />7.GFCI PROTECTION: ALL 125-VOLT THROUGH 250-VOLT RECEPTACLES INSTALLED IN <br />THE FOLLWOING LOCATIONS AND SUPPLIED BY SINGLE-PHASE BRANCH CIRCUITS <br />RATED 150 VOLTS OR LESS TO GROUND SHALL HAVE GROUND-FAULT <br />CIRCUIT-INTERRUPTER PROTECTION FOR PERSONNEL. [2022 CEC 210.8(A)] <br />A.BATHROOMS <br />B.GARAGES AND ACCESSORY BUILDINGS THAT HAVE A FLOOR LOCATED AT OR <br />BELOW GRADE LEVEL NOT INTENDED AS HABITABLE ROOMS AND LIMITED TO <br />STORAGE AREAS, WORK AREAS, AND SIMILAR <br />C.OUTDOORS <br />D.BASEMENTS <br />E.KITCHENS <br />F.LAUNDRY AREAS <br />G.INDOOR DAMP AND WET LOCATIONS <br />8.PROVIDE LISTED TAMPER-RESISTANT RECEPTACLES IN ALL AREAS EXCEPT <br />RECEPTACLES LOCATED MORE THAN 5 1/2 FT ABOVE THE FLOOR AND A SINGLE <br />RECEPTACLE, OR A DUPLEX RECEPTACLE FOR TWO APPLIANCES, LOCATED WITHIN <br />THE DEDICATED SPACE FOR EACH APPLIANCE. [2022CEC 406.12] <br />9.RECEPTACLE LOCATION AND SPACING BETWEEN ADJACENT RECEPTACLE SHALL BE <br />PER [2022 CEC 210.52]. <br />10.ALL WORK TO COMPLY WITH THE [2022 CEC]. <br />11.ELECTRICAL EQUIPMENT SHALL BE LISTED BY A CITY RECOGNIZED ELECTRICAL <br />TESTING LABORATORY OR APPROVED BY THE CITY DEPARTMENT. <br />12.LIGHTS AND PANELS SHALL NOT BE RECESSED IN FIRE RATED ASSEMBLIES UNLESS <br />BOXED WITH EQUIVALENT CONSTRUCTION. <br />13.PANEL CIRCUIT DIRECTORY TO COMPLY WITH [2022 CEC 408.4] . <br />14.ALL ATTIC ACCESSES SHALL BE PROVIDED WITH A SWITCHED LIGHT AND 120 VOLT <br />OUTLET AT OR NEAR THE FORCED AIR UNIT. [2022 CEC 210.70(C)] <br />15.RECEPTACLES/PARTS OF CORD-CONNECTED LUMINAIRES SHALL NOT BE INSTALLED <br />AND LIGHTING FIXTURES SHALL BE LISTED FOR A WET LOCATION WITHIN A ZONE <br />MEASURED 3FT HORIZONTALLY AND 8 FT VERTICALLY FROM THE TOP OF THE <br />BATHTUB RIM OR SHOWER STALL. [2022 CEC 406.9(C), 410.10(D)] <br />16.BATHROOM EXHAUST FAN MUST BE CONTROLLED BY A HUMIDISTAT WHICH SHALL BE <br />READILY ACCESSIBLE. [2022 CALGREEN 4.506.1] <br />17.AT LEAST ONE READILY ACCESSIBLE OUTDOOR RECEPTACLE FROM GRADE SHALL BE <br />INSTALLED FOR EACH DWELLING UNIT OF A MULTIFAMILY DWELLING, AND EVERY <br />BALCONIES/DECKS WITH WEATHER PROOF COVER OF EXTERIOR OUTLETS. [2022 CEC <br />210.52 (E), 406.9(B)(2)] <br />18.ALL LIGHTING SHALL BE HIGH EFFICACY. [2022 CENC 150.0(K), TABLE 150.0-A] <br />19.IN BATHROOMS, GARAGES, LAUNDRY ROOMS, UTILITY ROOMS, AND WALK-IN CLOSETS, <br />AT LEAST ONE INSTALLED LUMINAIRE SHALL BE CONTROLLED BY AN OCCUPANCY OR <br />VACANCY SENSOR PROVIDING AUTOMATIC-OFF FUNCTIONALITY. [2022 CENC <br />150.0(K)(2)(E)] <br />20.LIGHTING IN HABITABLE SPACES, INCLUDING BUT NOT LIMITED TO LIVING ROOMS, <br />DINING ROOMS, KITCHENS, AND BEDROOMS, SHALL HAVE READILY ACCESSIBLE <br />WALL-MOUNTED DIMMING CONTROLS EXCEPT LUMINAIRES CONNECTED TO A CIRCUIT <br />WITH CONTROLLED LIGHTING POWER LESS THAN 20 WATTS OR CONTROLLED BY AN <br />OCCUPANCY/VACANCY SENSOR. [2022 CENC 150.0(K)(2)(F), EXCEPTION 2] <br />21.OUTDOOR LIGHTING CONNECTED TO A BUILDING MUST BE CONTROLLED WITH A <br />MANUAL ON/OFF SWITCH PLUS AN ASTRONOMICAL TIMECLOCK, OR PHOTOCELL AND <br />EITHER MOTION SENSOR OR AUTOMATIC AND TIME SWITCH. [2022 CENC 150.0(K)(3)(A)] <br />22.AT LEAST ONE READILY ACCESSIBLE OUTDOOR RECEPTACLE FROM GRADE SHALL BE <br />INSTALLED FOR EACH DWELLING UNIT OF A MULTIFAMILY DWELLING, AND EVERY <br />BALCONIES/DECKS WITH WEATHER PROOF COVER OF EXTERIOR OUTLETS. [2022 CEC <br />210.52 (E), 406.9(B)(2)] <br />23.NEW OR REPLACEMENT GARAGES SHALL HAVE BATTERY BACK-UP INSTALLED FOR <br />ANY GARAGE DOOR OPENERS. [SB969]. <br />UNIT#1 <br />GARAGE <br />1-2 <br />FC <br />1-1 <br />FC <br />1 <br />HP <br />1 <br />HP <br />1 <br />HP <br />1 <br />HP 1 <br />HP <br />1 <br />HP <br />1 <br />HP <br />1 <br />HP <br />1 <br />HP <br />HP-6F <br />R1-14/16 <br />3#10, <br />#10GND- <br />3/4"C <br />F25AF/30AS <br />/2P/WP <br />R3-14/16 <br />25AF/30AS <br />/2P/WP <br />(UNIT 1) <br />3#10, <br />#10GND- <br />3/4"C <br />F25AF/30AS <br />/2P/WP <br />R4-14/16 <br />3#10, <br />#10GND- <br />3/4"C <br />F25AF/30AS <br />/2P/WP <br />R5-14/16 <br />3#10, <br />#10GND- <br />3/4"C <br />F25AF/30AS <br />/2P/WP <br />R6-14/16 <br />3#10, <br />#10GND- <br />3/4"C <br />F25AF/30AS <br />/2P/WP <br />R7-14/16 <br />3#10, <br />#10GND- <br />3/4"C <br />F25AF/30AS <br />/2P/WP <br />R8-14/16 <br />3#10, <br />#10GND- <br />3/4"C <br />F25AF/30AS <br />/2P/WP <br />R9-14/16 <br />3#10, <br />#10GND- <br />3/4"C <br />F25AF/30AS <br />/2P/WP <br />R10-14/16 <br />(UNIT 2)(UNIT 5)(UNIT 7)(UNIT 9)(UNIT 4)(UNIT 6)(UNIT 8)(UNIT 10) <br />WP <br />(TYP.) <br />WP <br />(TYP.) <br />6 5 <br />(TYP.) <br />6 5 <br />(TYP.)44 <br />RE <br />V <br />I <br />S <br />I <br />O <br />N <br />SHEET TITLE: <br />DATE: SCALE: <br />GA <br />R <br />F <br />I <br />E <br />L <br />D <br /> <br />R <br />E <br />S <br />T <br />O <br />R <br />A <br />T <br />I <br />O <br />N <br /> <br />/ <br /> <br />R <br />E <br />M <br />O <br />D <br />E <br />L <br />03/05/2023 <br />PLOT DATE: 9/12/2024 5:11:28 PM <br />CD <br />I <br /> <br />Ci <br />r <br />c <br />a <br /> <br />D <br />o <br />m <br />i <br />n <br />i <br /> <br />I <br />n <br />t <br />e <br />r <br />n <br />a <br />t <br />i <br />o <br />n <br />a <br />l <br />, <br /> <br />I <br />n <br />c <br />. <br />En <br />g <br />i <br />n <br />e <br />e <br />r <br />i <br />n <br />g <br /> <br />- <br /> <br />C <br />o <br />n <br />s <br />u <br />l <br />t <br />i <br />n <br />g <br />98 <br />9 <br />0 <br /> <br />R <br />e <br />s <br />e <br />a <br />r <br />c <br />h <br /> <br />D <br />r <br />. <br /> <br />S <br />u <br />i <br />t <br />e <br /> <br />1 <br />0 <br />0 <br />, <br /> <br />I <br />r <br />v <br />i <br />n <br />e <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />6 <br />1 <br />8 <br />Ph <br />o <br />n <br />e <br /> <br />( <br />9 <br />4 <br />9 <br />) <br /> <br />5 <br />3 <br />3 <br />- <br />4 <br />1 <br />1 <br />7 <br /> <br />| <br /> <br />d <br />k <br />a <br />n <br />g <br />@ <br />c <br />d <br />i <br />e <br />n <br />g <br />. <br />c <br />o <br />m <br />82 <br />9 <br /> <br />N <br /> <br />G <br />A <br />R <br />F <br />I <br />E <br />L <br />D <br /> <br />S <br />T <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />1 <br />DRAWN: CHECKED: <br />PL <br />A <br />N <br /> <br />C <br />H <br />E <br />C <br />K <br /> <br />R <br />E <br />V <br />. <br /> <br />0 <br />4 <br />/ <br />2 <br />7 <br />/ <br />2 <br />0 <br />2 <br />3 <br />PL <br />A <br />N <br /> <br />C <br />H <br />E <br />C <br />K <br /> <br />R <br />E <br />V <br />. <br /> <br />0 <br />9 <br />/ <br />2 <br />8 <br />/ <br />2 <br />0 <br />2 <br />3 <br />IN <br />S <br />P <br />E <br />C <br />T <br />I <br />O <br />N <br /> <br />R <br />E <br />V <br />. <br /> <br />0 <br />6 <br />/ <br />1 <br />9 <br />/ <br />2 <br />0 <br />2 <br />4 <br />PL <br />A <br />N <br /> <br />C <br />H <br />E <br />C <br />K <br /> <br />R <br />E <br />V <br />. <br /> <br />0 <br />9 <br />/ <br />0 <br />4 <br />/ <br />2 <br />0 <br />2 <br />4 <br />E100 <br />1/4" = 1'-0" <br />ELECTRICAL <br />PLAN - GROUND <br />FLOOR <br />J.L.L.N. <br />HOLD- 829 N <br />Garfield St1/15/2025