Project Name:VVS - 829 N Garfield St Engineer:Elie Sayegh, PE <br />Project No.:127 Date: <br />Project Name:VVS - 829 N Garfield St <br />Project Address:829 N Garfield St, Santa Ana <br />Local Jurisdiction Santa Ana, CA <br />Project #:127 <br />Project Engineer:Elie Sayegh, PE <br />Gov. Codes:CBC 2022 | ASCE 7-16 | ACI 318-19 | NDS 2018 <br />Risk Category:II <br />Bldg. Classification:Enclosed <br />Submittal Date: <br />Submittal Label:1st Building Department Submittal <br />Lateral Force System:Light Framed Wood Shear Walls <br />Stories:2 <br />Wind Site Parameters:SS 1.297 SMS 1.556 <br />Wind Exposure:B Fa 1.200 SDS 1.038 <br />Wind Speed:95.0 S1 0.462 SM1 NA <br />Seismic Site Parameters:Fv NA SD1 NA <br />Site Classification:D R:6.5 Cs:0.160 <br />Seismic Design Cat.D Ω:2.5 0.7 Cs:0.112 <br />Imp. Factor Ie:1.00 ρ:1.3 0.7 ρ Cs:0.145 <br />Geo Engineer:CBC Presumptive Values Allowable Bearing 1500 psf <br />Geo Report No.:NA Allowable Passive 100 pcf <br />Geo Report Date: NA Maximum Passive 1000 pcf <br />Fnd System:Conventional Spread Footings % of Passive 100% <br />Min, Req Depth:18 Coefficient of Friction 0.25 <br />Min Req. Width:15 <br />Min Req. Reinf:2 - #5 T&B <br />July 3, 2024 <br />7/3/2024 <br />A. Project Information <br />Summary Description <br />Structural engineering services for legalization of the ongoing restoration of the 2-story 10-unit apartment <br />building. Please see below project information as well as the basis of design. <br />Project Data <br />Site Specific Information <br />Soils Information <br />Page 4 <br />HOLD- 829 N <br />Garfield St1/15/2025