GENERAL <br />1. NOTES AND DETAILS ON THE STRUCTURAL DRAWINGS TAKE <br />PRECEDENCE OVER THESE STANDARD STRUCTURAL NOTES. <br />DETAILS NOTES AS "TYPICAL DETAILS" SHALL BE USED WHENEVER <br />APPLICABLE. REFER TO SPECIFICATIONS FOR INFORMATION NOT <br />COVERED BY THESE NOTES OR DRAWINGS. <br />2. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS, ELEVATIONS, <br />AND SITE CONDITIONS BEFORE STARTING WORK, AND THE <br />ENGINEER/ARCHITECT SHALL BE NOTIFIED IMMEDIATELY, IN WRITING, <br />OF ANY DISCREPANCIES. IN NO CASE SHALL DIMENSIONS BE SCALED <br />FROM PLANS, SECTIONS, OR DETAILS ON THE STRUCTURAL <br />DRAWINGS. <br />3. ALL OMISSIONS AND CONFLICTS BETWEEN THE VARIOUS ELEMENTS <br />OF THE STRUCTURAL DRAWINGS AND/OR SPECIFICATIONS SHALL BE <br />BROUGHT TO THE ATTENTION, AND RESOLVED WITH, THE ENGINEER <br />BEFORE PROCEEDING WITH ANY WORK SO INVOLVED. <br />4. WHERE A CONSTRUCTION DETAIL IS NOT SPECIFICALLY SHOWN OR <br />NOTES, THE DETAIL SHALL BE THE SAME AS FOR OTHER SIMILAR <br />WORK. <br />5. THE CONTRACTOR SHALL DETERMINE THE LOCATION OF UTILITY <br />SERVICES IN THE AREA TO BE EXCAVATED, BEFORE BEGINNING <br />EXCAVATION. <br />6. NO PIPES, DUCTS, SLEEVES, CHASES, ETC. SHALL BE PLACED IN OR <br />THROUGH SLABS, BEAMS, OR WALLS, NOR SHALL ANY STRUCTURAL <br />MEMBER BE CUT FOR PIPES, DUCTS, ETC. EXCEPT AS INDICATED ON <br />THE STRUCTURAL DRAWINGS. THE CONTRACTOR SHALL OBTAIN <br />PRIOR APPROVAL FOR INSTALLATION OF ANY ADDITIONAL PIPES, <br />DUCTS, ETC. <br />7. ALL MATERIALS AND WORKMANSHIP SHALL CONFORM TO THE <br />REQUIREMENTS OF THE 2022 CBC. <br />8. THE CONTRACTOR SHALL ASSUME SOLE AND COMPLETE <br />RESPONSIBILITY FOR THE JOB SITE CONDITIONS DURING THE <br />COURSE OF CONSTRUCTION OF THIS PROJECT, INCLUDING SAFETY <br />OF ALL PERSONS AND PROPERTY. THIS REQUIREMENT SHALL APPLY <br />CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS. <br />9. RETAIN A CALIFORNIA REGISTERED CIVIL ENGINEER TO DESIGN ALL <br />TEMPORARY BRACING, SHORING, AND SUPPORT REQUIRED DURING <br />CONSTRUCTION. <br />10. INCLUDE ENGINEERING FEES, ENGINEERING DESIGN TIME AND <br />BUILDING DEPARTMENT APPROVAL TIME IN THE COST OF PROPOSED <br />MATERIAL ALTERNATIVES. CONTACT ENGINEER FOR FEE AMOUNT. <br />SUBMIT MATERIAL ALTERNATIVE FOR REVIEW BEFORE <br />CONSTRUCTION. <br />DESIGN CRITERIA <br />1. VERTICAL LOADS (GRAVITY): <br />a) DEAD LOADS: <br />MASONRY WALL 12"..........124 PSF <br />MASONRY WALL 8"............78 PSF <br />METAL DOOR......................7 PSF <br />2. LATERAL LOADS: <br />a) EARTHQUAKE DESIGN DATA: <br />V = 0.15 W (ASD) (INCLUDES RHO = 1.3) <br />SEISMIC IMPORTANCE FACTOR..........1 <br />RISK CATEGORY.....................................II <br />MAPPED SPECTRAL RESPONSE ACCELERATIONS <br />Ss....................................................1.520 <br />S1....................................................0.590 <br />SITE CLASS..............................................D <br />SPECTRAL RESPONSE COEFFICIENTS <br />Sds..................................................1.170 <br />Sd1..................................................0.850 <br />ANALYSIS PROCEDURE: EQUIVALENT LATERAL FORCE <br />PROCEDURE <br />b) WIND: <br />BASIC WIND SPEED................................95 MPH <br />SITE EXPOSURE......................................C <br />IMPORTANCE FACTOR...........................1.0 <br />FOUNDATION <br />1. SOILS INFORMATION: <br />BEARING PRESSURE = 1500 PSF (13 INCREASE FOR WIND OR SEISMIC) <br />2. BOTTOM OF FOOTING SHALL BE AT LEAST 24 INCHES BELOW THE <br />LOWEST ADJACENT FINISHED GRADE INTO COMPETENT SOIL. <br />3. REFER TO AND CHECK WITH ARCHITECTURAL DRAWINGS FOR <br />VARIOUS FLOOR SLOPES, DROPPED SLABS, DEPRESSIONS, CURBS, <br />STEPS, WALKS DRAINS, DEPRESSED FLOOR, ETC. & DIMENSIONS NOT <br />SHOWN. <br />4. NO CONCRETE SHALL BE POURED IN ANY FOUNDATION UNTIL <br />EXCAVATION HAS BEEN INSPECTED, EXCAVATION SHALL BE KEPT <br />FREE OF LOOSE MATERIAL AND STANDING WATER. <br />5. ALL SLEEVES THROUGH FOUNDATION WALLS AND UNDER FOOTING <br />TO BE INSTALLED PRIOR TO FOUNDATION POUR. SEE TYPICAL <br />DETAILS. <br />6. NO SLEEVING OF ANY GRADE BEAM WILL BE PERMITTED UNLESS <br />SHOWN ON STRUCTURAL DRAWINGS APPROVED BY THE ENGINEER. <br />7. THE ENGINEER HAS NO CONTROL OR RESPONSIBILITY FOR THE <br />DESIGN OF TEMPORARY SHORING, SCAFFOLDING, FORMING, <br />UNDERPINNING, ETC., NOT DETAILED ON THESE PLANS. <br />8. ALL EXCAVATIONS SHALL BE PROPERLY BACKFILLED. DO NOT PLACE <br />BACKFILL BEHIND RETAINING WALLS BEFORE CONCRETE (OR <br />GROUT) HAS OBTAINED FULL DESIGN STRENGTH. CONTRACTOR <br />SHALL BRACE OR PROTECT ALL BUILDING AND PIT WALLS BELOW <br />GRADE FROM LATERAL LOADS UNTIL ATTACHING FLOORS ARE <br />COMPLETELY IN PLACE AND HAVE ATTAINED FULL STRENGTH. <br />CONTRACTOR SHALL PROVIDE FOR DESIGN, PERMITS, AND <br />INSTALLATION OF SUCH BRACING. <br />9. CONTRACTOR SHALL COORDINATE ALL DIMENSIONS AND <br />ELEVATIONS WITH ARCHITECTURAL DRAWINGS. NOTIFY <br />STRUCTURAL ENGINEER, PRIOR TO FABRICATION OR ERECTION, <br />WHEN DISCREPANCIES ARE FOUND. <br />REBAR <br />1. NO BRICK OR POROUS MATERIAL SHALL BE USED TO SUPPORT <br />FOOTING STEEL OFF THE GROUND. PRECAST CONCRETE ADOBES <br />ARE APPROVED. <br />2. BAR REINFORCEMENT SHALL BE ASTM A615, GRADE 60. <br />3. BAR REINFORCEMENT THAT IS NOT WELDED SHALL BE ASTM A706, <br />GRADE 60. WELDING OF REINFORCING BARS SHALL CONFORM TO <br />AWS D1.4-92 AND CBC STANDARDS 19-1. E90XX ELECTRODES SHALL <br />BE USED, SPECIAL INSPECTION IS REQUIRED FOR ALL FIELD <br />WELDING. <br />4. SPLICES IN REINFORCING STEEL SHALL LAP AS FOLLOWS, UNLESS <br />NOTES OTHERWISE: #3 THOUGH #6 =45 DIA., #7 TROUGH #11 = 56 DIA. <br />HORIZONTAL SPLICES SHALL BE STAGGERED. NON-CONTACT <br />SPLICES SHALL NOT BE SPACED TRANSVERSELY FARTHER APART 15THE REQUIRED LAP SPLICE LENGTH, OR 6 INCHES. <br />5. THE CLEAR DISTANCE BETWEEN PARALLEL BARS SHALL BE FOUR <br />BAR DIAMETERS BUT NO LESS THAN 112" U.O.N.. IN WALLS AND SLABS <br />OTHER THAN THE CONCRETE JOIST CONSTRUCTION, BARS SHALL BE <br />SPACED NOT FARTHER APART THAN THREE TIMES THE WALL OR <br />SLAB THICKNESS, NOR 18 INCHES. <br />6. REINFORCING STEEL SHALL HAVE A PROTECTED CONCRETE <br />COVERING AS FOLLOWS, U.O.N.: <br />WALL BARS BELOW GRADE: <br />ON DIRT SIDE WHEN POURED AGAINST DIRT..... =3" <br />ON DIRT SIDE WHEN FORMED.................... ........ =2" <br />WALL BARS ABOVE GRADE: <br />FOOTING PADS.................................... =3" <br />SLABS (ON EARTH)............................=2" <br />SLABS (LIGHT WEIGHT CONCRETE).... =34" <br />SLABS (HARD ROCK CONCRETE).......=1" <br />JOISTS (SIDES, TOPS, & SOFFITS)...=1" <br />COLUMNS (TO MAIN STEEL)..............=2" <br />BEAM, GIRDERS (SIDES, TOPS, & SOFFITS)...= 2" <br />IN ALL OTHER CASES........................=112" <br />7. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A185 AND SHALL <br />BE LAPPED 12 INCHES MINIMUM. <br />8. ALL WALLS SHALL BE DOWELED TO SUPPORTING FOOTINGS, BEAMS, <br />PADS, ETC., WITH BARS THE SAME SIZE AND SPACING AS VERTICAL <br />BARS IN THE WALL UNLESS OTHERWISE DETAILED. ANCHORAGE OF <br />DOWELS SHALL BE EQUIVALENT OF A BAR SPLICE. <br />9. DOWEL REINFORCED SLABS TO WALLS AND OTHER EDGE MEMBERS <br />PER TYPICAL DETAILS. <br />10. ALL REINFORCING STEEL IS TO BE PLACED IN A RELATIVE POSITION <br />SHOWN ON DRAWINGS. NO SPLICES IN ANY REINFORCING WILL BE <br />PERMITTED EXCEPT THOSE SHOWN ON THE STRUCTURAL <br />DRAWINGS. <br />11. REINFORCING DETAILING, BENDING, AND PLACING SHALL BE ION <br />ACCORDANCE WITH THE CONCRETE REINFORCING STEEL <br />INSTITUTES "MANUAL OF STANDARD PRACTICE", LATEST EDITION. <br />12. ALL REINFORCING STEEL, ANCHOR BOLTS, DOWELS, AND INSERTS <br />SHALL BE WELL SECURED IN THE POSITION WITH THE WIRE <br />POSITIONERS BEFORE PLACING CONCRETE OR GROUT. VERTICAL <br />BARS IN THE MASONRY WALLS SHALL BE TIED IN POSITION AT THE <br />TOP AND BOTTOM AND INTERVALS NOT EXCEEDING 200 BAR <br />DIAMETERS. <br />CONCRETE <br />1. CEMENT SHALL CONFORM TO ASTM C150, TYPE II. <br />2. AGGREGATES FOR NORMAL WEIGHT CONCRETE SHALL CONFORM TO <br />ASTM C33. <br />3. CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF <br />2,500 PSI AT 28 DAYS: (4"MAX. SLUMP FOR FLATWORK). <br />MIN. COMPRESSIVE STRENGTH FOR WALLS TO BE 3,000 PSI <br />MIN. COMPRESSIVE STRENGTH FOR GRADE BEAMS TO BE 3,000 PSI <br />MIN. COMPRESSIVE STRENGTH FOR CAISSON TO BE 3,000 PSI <br />4. ADMIXTURES MAY BE USED WITH PRIOR APPROVAL OF THE <br />ENGINEER. ADMIXTURES SHALL COMPLY WITH ASTM C494 & C107 <br />AND BE OF A TYPE THAT INCREASES THE WORKABILITY OF THE <br />CONCRETE, BUT SHALL NOT BE CONSIDERED TO REDUCE THE <br />SPECIFIED MINIMUM CEMENT CONTENT (CALCIUM CHLORIDE SHALL <br />NOT BE USED). <br />5. NO CONDUIT PLACED IN A CONCRETE SLAB SHALL HAVE AN OUTSIDE <br />DIAMETER GREATER THAN 13 THE THICKNESS OF THE SLAB. NO <br />CONDUIT SHALL BE EMBEDDED IN A SLAB THAT IS LESS THAN 312" <br />THICK. EXCEPT FOR LOCAL OFFSETS, MINIMUM CLEAR DISTANCE <br />BETWEEN CONDUITS SHALL BE THREE DIAMETERS ON CENTER <br />(EXCEPT IF THE CONDUIT IS PASSING THROUGH). <br />6. PROJECTING CORNERS OF SLABS, BEAMS, WALLS, COLUMNS, ETC., <br />SHALL BE FORMED WITH 34" CHAMFERS. <br />7. REFER TO DRAWINGS OF OTHER DISCIPLINES FOR MOLDS, <br />GROOVES, CLIPS, ORNAMENTS, OR GROUNDS REQUIRED TO BE CAST <br />IN CONCRETE. <br />8. ALL SLABS ON GRADE SHALL HAVE CONTROL JOINTS INSTALLED TO <br />PROVIDE APPROXIMATELY 15 FOOT SQUARES UNLESS DETAILED <br />OTHERWISE ON THE PLANS. WHERE CONCRETE POURS ARE <br />STOPPED, THE JOINTS SHALL BE FORMED. SEE "TYPICAL <br />SLAB-ON-GRADE JOINT DETAIL". <br />STRUCTURAL WOOD <br />1. ALL FRAMING LUMBER SHALL BE DOUGLAS FIR-LARCH GRADE <br />MARKED BY A RECOGNIZED GRADING AGENCY (WCLIB 0R WWPA), <br />VOLUNTARY STANDARD DOC PS20-25. <br />LIGHT FRAMING....................CONSTRUCTION <br />JOISTS & PLANKS.................No. 2 <br />BEAMS & STRINGERS...........No. 1 <br />POST AND TIMBERS..............No. 1 <br />PARALLAM (PSL)....................2.0E WS (2900 Fb) <br />MICROLLAM (LVL)..................2.0E WS (2900 Fb) <br />VERTICAL STUDS: <br />2x4 STUDS, 8'-0" LONG..........CONSTRUCTION GRADE <br />2x4 STUDS, 8'-1" TO 14'-0".....No. 1 <br />2x6 STUDS..............................No. 2 <br />ALL OTHER LUMBER..............No. 1 STRUCTURAL LIGHT FRAMING <br />2. ALL SILL PLATES RESTING ON CONCRETE OR MASONRY, WHICH IS IN <br />CONTACT WITH EARTH OR RESTING ON FOUNDATIONS SHALL BE <br />PRESSURE TREATED DOUGLAS FIR (PT.D.F.). ALL FASTENERS SUCH <br />AS NAILS, BOLTS, SCREWS, ANCHOR BOLTS, ETC., ATTACHING <br />P.T.D.F. OR FIRE-RETARDANT TREADED WOOD SHALL BE HOT-DIPPED <br />ZINC COATED GALVANIZED OR STAINLESS STEEL (ASTM A153). <br />3. WHERE STUD PARTITIONS JOIN CONCRETE OR MASONRY WALLS, <br />THE END STUD WALL SHALL BE ANCHORED THERETO WITH 12" (BOLTS <br />NEAR THE TOP & BOTTOM AND AT EACH ROW OF TIRE BLOCKING. <br />SUCH BOLTS SHALL BE EMBEDDED IN TH EWALL NOT LESS THAN 23 OF <br />THE WALL THICKNESS OR 8" MAX). <br />4. CUTTING, NOTCHING, OR BORING OF STUDS SHALL BE PERMITTED <br />ONLY AS DETAILED OR APPROVED BY ENGINEER AND/OR PER 2022 <br />CBC TABLE 2308.5.9 OR 2308.5.10. <br />5. ALL NAILING SHALL CONFORM TO 2022 CBC TABLE 2304.10.1, AND <br />SHALL BE COMMON NAILS, UNLESS NOTED OTHERWISE ON PLANS <br />AND DETAILS. <br />6. ALL BOLY HEADS AND NUTS BEARING ON WOOD SHALL HAVE <br />STANDARD CUT WASHERS. HOLES FOR BOLTS SHALL BE BORED 116" <br />LARGER THAN THE NOMINAL DIAMETER. BOLTS IN THE WOOD SHALL <br />NOT BE LESS THAN 7 DIAMETERS FROM THE END AND 4 DIAMETERS <br />FROM THE EDGE OF THE MEMBER, <br />7. TOP PLATES OF ALL WOOD STUD WALLS TO BE 2-2x MINIMUM (SAME <br />WIDTH AS STUDS), LAP 48" MIN. WITH NOT LESS THAN 6-16d NAILS AT <br />EACH LAP AND NOT MORE THAN 12" BETWEEN NAILS. <br />8. PLYWOOD SHALL BE APA STRUCTURAL I RATED SHEATHING WITH <br />EXTERIOR GLUE, PER DOC PS1 OR DOC PS2. <br />9. PROVIDE DOUBLED JOISTS UNDER ALL PARALLEL PARTITIONS. <br />10. ALL LAG SCREWS TO BE PREDRILLED, DRILL DIAMETER TO BE 40 TO <br />70 PERCENT OF THREADED SHANK DIAMETER AND FULL DIAMETER <br />FOR SMOOTH SHANK PORTION. <br />11. RE-TIGHTEN ALL ANCHOR BOLTS JUST BEFORE CLOSING IN. <br />12. ALL FRAMING ANCHORS, POST CAPS, BASES, HANGERS, STRAPS, <br />ETC. SHALL BE AS MANUFACTURED BY "SIMPSON COMPANY" OR <br />ENGINEER APPROVED EQUAL. <br />13. PROVIDE BLOCKING OR BRIDGING PER 2021 NDS SECTION 4.4.1 & <br />2022 CBC SECTION 2308.4.6 AND SECTION 2308.5.7. <br />14. MOISTURE CONTENT OF WOOD AT TIME OF PLACING SHALL NOT <br />EXCEED 19 PERCENT. <br />15. MACHINE BOLTS SHALL BE GRADE-A CONFORMING TO ASTM A307. <br />ANCHOR BOLTS SHALL BE ASTM F1554, GRADE 36. NUTS FOR <br />MACHINE BOLTS AND ANCHOR BOLTS SHALL CONFORM TO ASTM <br />A563, HEX GRADE-A. THREADED RODS SHALL CONFORM TO ASTM <br />A36. THREADED AND NUTTED ANCHOR BOLTS SHALL BE ASTM F1554, <br />GRADE 36. ROUNDS WASHERS SHALL CONFORM TO ASTM F436. <br />CONCRETE MASONRY <br />1. CONCRETE MASONRY WALL SHALL HAVE A MINIMUM 28 DAY <br />COMPRESSIVE STRENGTH OF f'm = 1,500 PSI. <br />2. CONCRETE MASONRY UNITS SHALL BE MEDIUM WEIGHT UNITS <br />CONFORMING TO ASTM C90, GRADE N-I, WITH MAXIMUM LINEAR <br />SHRINKAGE OF 0.06% (1,900 PSI MIN). <br />3. MORTAR SHALL BE TYPE S, CONFORMING ASTM C270 (MINIMUM 1,900 <br />PSI AT 28 DAYS). <br />4. GROUT SHALL BE COURSE GROUT AS DEFINES IN ASTM C476 WITH 38" <br />MAXIMUM AGGREGATE SIZE (MIN COMPRESSIVE STRENGTH OF 2,000 <br />PSI AT 28 DAYS). <br />5. FILL ALL CELLS WITH GROUT. ALL GROUT SHALL BE CONSOLIDATED <br />WITH A MECHANICAL VIBRATOR. <br />6. HIGH LIFT GROUTED CONSTRUCTION SHALL CONFORM TO TMS <br />602/ACI 530.1/ASCE 6 SECTION 3.5 TABLE 7. SPECIAL SHALL BE <br />PROVIDED FOR HIGH-LIFT CONSTRUCTION. <br />7. WHEN GROUTING IS STOPPED FOR ONE HOUR OR LONGER, HORIZ. <br />CONSTRUCTION JOINTS SHALL BE FORMED BY STOPPING THE <br />GROUT POUR 112" BELOW TOP OF THE UPPER MOST UNIT. <br />8. VERTICAL REINFORCEMENTS SHALL BE CONTINUOUS FROM FLOOR <br />TO ROOF, UNLESS SHOWN OTHERWISE. <br />9. ALL HORIZONTAL REINFORCEMENTS SHALL BE PLACED IN BOND <br />BEAM OR LINTEL BEAM UNITS. ALL BOND BEAM BLOCKS SHALL BE <br />DEEP CUT UNITS. <br />10. ANCHOR BOLTS MUST BE SET WITH TEMPLATES AND HELD IN PLACE <br />PRIOR TO GROUTING, PROVIDE AT LEAST ONE INCH OF GROUT <br />BETWEEN ANCHOR BOLTS AND MASONRY. <br />11. COMPRESSIVE STRENGTH OF MASONRY MUST BE VERIFIED BY PRISM <br />TESTING PRIOR TO AND DURING CONSTRUCTION AS SPECIFIED IN <br />CBC SECTION 2105.2.2.2. <br /> 4 <br />6 <br />2 <br />1 <br /> <br />W <br />E <br />S <br />T <br /> <br />1 <br />S <br />T <br /> <br />S <br />T <br />R <br />E <br />E <br />T <br />NE <br />W <br /> <br />F <br />E <br />N <br />C <br />E <br />46 <br />2 <br />1 <br /> <br />W <br />E <br />S <br />T <br /> <br />1 <br />S <br />T <br /> <br />S <br />T <br />R <br />E <br />E <br />T <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />3 <br />JOSE RAMIREZ, PE <br />jose@ramirezstructural.com <br />(562) 519-6045 <br />ig: @ramirezstructural <br />www.ramirezstructural.com <br />REVISION DESCRIPTION DATE <br />A <br />B <br />C <br />PROJECT NO.23-101 <br />DATE:1/18/24 <br />RAMIREZSTRUCTURAL INC <br />STRUCTURAL <br />NOTES <br />S1.0 <br />HOLD- 4621 W First <br />St12/19/2024