My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
HOLD-2903 S Halladay St - Plan
PBA
>
Building
>
ProjectDox
>
H
>
Halladay St
>
2903 S Halladay St
>
HOLD-2903 S Halladay St - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/1/2025 12:11:22 PM
Creation date
6/1/2025 12:11:15 PM
Metadata
Fields
Template:
Plan
Permit Number
102122163
Full Address
2903 S Halladay St
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
9
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
HALLADAY ST. <br />2909 <br />2911 <br />2907 <br />29052903 <br />PARKING LOT <br />100' P.L <br />14 <br />0 <br />' <br /> <br />P <br />. <br />L <br />. <br />14 <br />0 <br />' <br /> <br />P <br />. <br />L <br />. <br />100' P.L <br />ELECTROMECHANICAL GATE <br />61'-1" <br />17'-0" <br />20 <br />' <br />- <br />2 <br />" <br />MAN DOOR EGRESS <br />20'-0" <br />17 <br />' <br />- <br />0 <br />" <br />9' <br />- <br />6 <br />" <br />(E) ADA <br />PARKING <br />SPACE <br />SIGNAGE <br />PA <br />TH <br /> <br />O <br />F <br />TR <br />A <br />VE <br />L <br />NO <br /> <br />P <br />A <br />R <br />K <br />I <br />N <br />G <br />NO PARKING <br />WORK IS LIMITED TO THIS AREA <br />25'-0" <br />FIRE HYDRANT <br />W/ PROTECTIVE <br />CURB <br />FIRE ACCESS ROADWAY <br />8' <br />- <br />6 <br />" <br />18'-0" <br />25 <br />' <br />- <br />0 <br />" <br /> <br />60 <br />" <br />12" <br />48 <br />" <br />CBC 11B-404.2.4 (Door/Gate <br />Maneuvering Clearances). <br />10. <br />9. <br />11. <br />1. <br />2. <br />3. <br />4. <br />5.72 <br />' <br />- <br />6 <br />" <br />6. <br />7. <br />8. <br />EXISTING <br />LINE <br />PROPERTY <br />BUILDING <br />JO <br />B <br /> <br />A <br />D <br />D <br />R <br />E <br />S <br />S <br />AS NOTED <br />a 12/16/20 BZ <br />b 2/26/25 BZ <br />DATE <br />SCALE <br />DRAWN <br />JOB <br />SHEET <br />REVISIONS BY <br />SHEET TITLE <br />PL <br />A <br />N <br /> <br />C <br />H <br />E <br />C <br />K <br /> <br />/ <br /> <br />P <br />E <br />R <br />M <br />I <br />T <br />29 <br />0 <br />3 <br /> <br />S <br /> <br />H <br />A <br />L <br />L <br />A <br />D <br />A <br />Y <br /> <br />S <br />T <br /> <br />Sa <br />n <br />t <br />a <br /> <br />A <br />n <br />a <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />5 <br />0000 <br />B.Z. <br />09.05.2024 <br />(714) 721 - 4067 <br />permitsync@gmail.com <br />PREPARED BY <br />BRYAN ZAMUDIO <br />09.01.2024 <br />LE <br />G <br />A <br />L <br /> <br />D <br />E <br />S <br />C <br />R <br />I <br />P <br />T <br />I <br />O <br />N <br />AP <br />N <br />: <br /> <br />TR <br />A <br />C <br />T <br />: <br /> <br />LO <br />T <br />: <br /> <br />41 <br />1 <br />- <br />0 <br />4 <br />1 <br />- <br />0 <br />4 <br /> 7 <br />1 <br />1 <br />BL <br />K <br />: <br />B <br />8 <br />/ <br /> <br />B <br />ENGINEERING <br />REGISTEREDPROFESSIONALENGINEER <br />STATEOF CALIFORNIA <br />JOHN L.TIONGCOC70915 <br />C I V IL <br />c 3/18/25 BZ <br />SCOPE OF WORK <br />DIRECTORY <br />PROPERTY <br />OWNER: <br />OCCUPANCY GROUP: <br />B, F-2, S-2 <br />USE : WAREHOUSE, <br />OFFICE, AND DISTRIBUTION <br />CENTER <br />CONSTRUCTION TYPE: V-B <br />NUMBER OF STORIES: 1 <br />HEIGHT OF BUILDING: <br />FIRE SPRINKLERED: <br />NO. OF PARKING SPACES: 10 <br />ADA PARKING SPACE: 1 <br />BUILDING DATA <br />ALL WORK SHALL COMPLY WITH: <br />2022 CALIFORNIA BUILDING CODE <br />2022 CALIFORNIA RESIDENTIAL CODE <br />2022 CALIFORNIA MECHANICAL CODE <br />2022 CALIFORNIA PLUMBING CODE <br />2022 CALIFORNIA ELECTRICAL CODE <br />2022 CALIFORNIA ENERGY CODE <br />2022 CALIFORNIA GREEN BUILDING CODE <br />2022 CALIFORNIA ENERGY STANDARDS <br />AND LOCAL ORDINANCES <br />SITE PLAN SCALE <br />1/16" = 1'-0" <br />LEGALIZING AS BUILT SLIDING GATE <br />AS PER: <br />1. Wall and fence requirements in the <br />industrial and commercial zones. <br /> SAMC 41-610.5 <br />ENGINEER: <br />THE DISCHARGE OF POLLUTANTS TO ANY STORM <br />DRAINAGE SYSTEM IS PROHIBITED. NO SOLID <br />WASTE, PETROLEUM BY-PRODUCTS, SOIL <br />PARTICULATE, CONSTRUCTION WASTE MATERIALS, <br />OR WASTEWATER GENERATED ON CONSTRUCTION <br />SITES OR BY CONSTRUCTION ACTIVITIES SHALL BE <br />PLACED, CONVEYED OR DISCHARGED INTO THE <br />STREET, GUTTER OR STORM DRAIN SYSTEM <br />TABLE OF CONTENTS <br />CONTENTS <br />1 <br />2 <br />SHEET <br />GATE ELEVATIONS <br />1 <br />CONTRACTOR: <br />ABBREVIATIONS <br />SITE PLAN <br />GENERAL NOTES <br />APPLICABLE CODES <br />PROPERTY AREA 14,000 Sq.Ft. <br />AREA SUMMARY <br />SITE PLAN <br />-Cardinal Investment Properties <br />– Halladay, LP. <br />David Seidner (GEN PTR) <br />2925 Bristol St. Costa Mesa, CA <br />92626 <br />Office: 714-557-1934 <br />N/A <br />ZONE M1 <br />A <br />COUNT <br />01 <br />02 <br />PROJECT <br />@ AT <br />ABV ABOVE <br />ALUM ALUMINUM <br />AFF ABOVE FIN FLOOR <br />BLDG BUILDING <br />BLK'G BLOCKING <br />BM. BEAM <br />B.N. BOUNDARY NAILING <br />CAB CABINET <br />CL CENTER LINE <br />CEIL CEILING <br />C.J. CEILING JOIST <br />CLR. CLEAR DIMENSION <br />CONC CONCRETE <br />CORR CORRIDOR <br />CONT CONTINUOUS <br />CONTR CONTRACTOR <br />CPT CARPET <br />DIM DIMENSION <br />DISP DISPENSER <br />DN DOWN <br />(E) EXISTING <br />E EAST <br />EA EACH <br />EA. WAY EACH WAY <br />ELEV ELEVATION <br />EXST'G EXISTING <br />F-E FIRE <br />EXTINGUISHER <br />FIXT FIXTURE <br />FLR. FLOOR <br />FLUO FLUORECENT <br />FOS FACE OF STUD <br />FOW FACE OF WALL <br />FTG FOOTING <br />FUT. FUTURE <br />GL GLASS OR GLAZING <br />GYP BD GYPSUM BOARD <br />HDR HEADER <br />HDWRE HARDWARE <br />HDCP HANDICAPPED <br />HR HOUR <br />i P.L. IMAGINARY <br />PROPERTY LINE <br />MFR MANUFACTURER <br />(N) NEW <br />N NORTH <br />NIC NOT IN CONTRACT <br />NTS NOT TO SCALE <br />oc ON CENTER <br />P.L. PROPERTY LINE <br />PLAS PLASTER <br />R.R. ROOF RAFTER <br />RPL'C REPLACE <br />RMVE'D REMOVED <br />REV REVISION <br />S SOUTH <br />SHLVS SHELVES <br />SHT'G SHEATHING <br />SIM SIMILAR <br />Sq.Ft. SQUARE FEET <br />TYP TYPICAL <br />UNO UNLESS NOTED <br />OTHERWISE <br />V.I.F. VERIFY IN FIELD <br />W WEST <br />W/ WITH <br />LEGEND <br />1'-0" <br />1'-0" <br />2' <br />- <br />0" <br />1 1/ <br />4 <br />" <br /> <br />2" <br /> <br />2" <br /> <br />3" <br /> <br />3" <br /> <br />8" <br />1 1/ <br />4 <br />" <br />3/ <br />4" <br /> <br />1/ <br />2 <br />" <br />1/ <br />2 <br />" <br /> <br />3/ <br />4 <br />" <br />70 SQUARE INCHES <br />MINIMUM <br />60" A.F.F MIN. MEASURE TO THE <br />BOTTOM OF THE SIGN(S) (80" A.F.F. MIN. <br />IF LOCATED WITHIN A CIRCULATION <br />PATH). EQUAL FOR ALL STALL SIGNS <br />R7-8B(CA) <br />R99B(CA) <br />R99C <br />(CA) <br />R99 <br />(CA) <br />2' <br />- <br />0 <br />" <br />2' <br />- <br />0" <br /> <br />3" <br />2' <br />- <br />0" <br />2" <br /> <br />2" <br /> <br />1" <br /> <br />2" <br /> <br />2" <br /> <br />1 1/ <br />2 <br />" <br /> <br />NOTE: PROVIDE THE WORDS <br />"VAN ACCESSIBLE" BELOW THE <br />ISA WHERE OCCURS. <br />ALTERNATIVELY AN ADDITIONAL <br />VAN ACCESSIBLE SIGN MAY BE <br />ADDED BELOW <br />OR <br />ADA PARKING SIGNAGE <br />1) A REMOTE OPENING DEVICE IS REQUIRED. THE REMOTE GATE OPENING <br />DEVICE THAT WILL BE INSTALLED IS : 3M OPTICOM <br />2) IN THE EVENT OF LOSS OF NORMAL POWER TO THE GATE OPERATING <br />MECHANISM, IT SHALL BE <br />AUTOMATICALLY TRANSFERRED TO A FAIL-SAFE MODE ALLOWING THE GATE TO BE <br />PUSHED OPEN BY A <br />SINGLE FIREFIGHTER WITHOUT ANY OTHER ACTIONS, KNOWLEDGE, OR <br />MANIPULATION OF THE OPERATING <br />MECHANISM BEING NECESSARY. <br />a) A BATTERY MAY ONLY BE USED IN PLACE OF FAIL-SAFE MANUAL OPERATION <br />WHEN THE GATE <br />OPERATOR HAS A FAIL-OPEN MODE THAT WILL AUTOMATICALLY, IMMEDIATELY, AND <br />COMPLETELY <br />OPEN THE GATE AND KEEP IT OPEN UPON REACHING A LOW POWER THRESHOLD, <br />REGARDLESS OF THE <br />PRESENCE OF NORMAL POWER. <br />b) SHOULD THE GATE BE TOO LARGE OR HEAVY FOR A SINGLE FIREFIGHTER TO <br />OPEN MANUALLY, A <br />SECONDARY SOURCE OF RELIABLE POWER BY MEANS OF AN EMERGENCY <br />GENERATOR OR A CAPACITOR <br />WITH ENOUGH RESERVE TO AUTOMATICALLY, IMMEDIATELY, AND COMPLETELY <br />OPEN THE GATE UPON <br />LOSS OF PRIMARY POWER SHALL BE PROVIDED FOR FAIL-OPEN OPERATION. <br />3) IN ADDITION TO THE REMOTE OPERATOR, THE GATE CONTROL SHALL BE <br />OPERABLE BY A KNOX EMERGENCY <br />OVERRIDE KEY SWITCH EQUIPPED WITH A DUST COVER. UPON ACTIVATION OF THE <br />KEY SWITCH, THE GATE <br />SHALL OPEN AND REMAIN OPEN UNTIL RETURNED TO NORMAL OPERATION BY <br />MEANS OF THE KEY SWITCH. <br />WHERE A GATE CONSISTS OF TWO LEAVES, THE KEY SWITCH SHALL OPEN BOTH <br />SIMULTANEOUSLY IF <br />OPERATION OF A SINGLE LEAF ON THE INGRESS SIDE DOES NOT PROVIDE FOR THE <br />WIDTH, TURNING RADII, <br />OR SETBACKS NECESSARY FOR FIRE APPARATUS TO NAVIGATE THE VEHICLE <br />ENTRY POINT. <br />4) THE KEY SWITCH SHALL BE PLACED BETWEEN 42” AND 48” ABOVE THE <br />ROADWAY SURFACE AT THE <br />RIGHT SIDE OF THE ACCESS GATE WITHIN TWO FEET OF THE EDGE OF THE <br />ROADWAY. IN IRVINE, THE <br />SWITCH SHALL BE ON THE LEFT SIDE IN ACCORDANCE WITH IRVINE’S UNIFORM <br />SECURITY ORDINANCE. <br />5) THE KEY SWITCH SHALL BE READILY VISIBLE AND UNOBSTRUCTED FROM THE <br />FIRE LANE LEADING TO THE <br />GATE. <br />6) THE KEY SWITCH SHALL BE LABELED WITH A PERMANENT RED SIGN WITH NOT <br />LESS THAN ½” CONTRASTING <br />LETTERS READING “FIRE DEPT” OR WITH A “KNOX” DECAL. <br />OCFA NOTES FOR ELECTRIC VEHICLE GATES <br />TABULATION <br />PARKING <br />USE TYPE: Sec. 41-1391. Warehouses <br />and distribution and wholesale uses. <br />(a) The minimum off-street parking <br />requirements for warehouses and <br />distribution and wholesale uses are as <br />follows: <br /> One (1) space for each one thousand <br />(1,000) square feet of gross floor area. <br />3 GATE SPECIFICATIONS 03 <br />GROSS FLOOR AREAB 8,260 Sq.Ft. <br />UNIT # <br />G.F.A <br />PARKING <br />RATIO <br />REQUIRED <br />SPACES <br />EXISTING <br />SPACES <br />1:1000 <br />SQ. FT <br />#2909 <br />1600 Sq.Ft <br />2 <br />NO PLANNED REDUCTION OF SPACES <br />USE <br />1:1000 <br />SQ. FT <br />#2911 <br />880 Sq.Ft <br />1 <br />1:1000 <br />SQ. FT <br />#2907 <br />480 Sq.Ft <br />1 <br />1:1000 <br />SQ. FT <br />#2905 <br />3050 Sq.Ft <br />4 11 <br />#2903 <br />2250 Sq.Ft <br />3 <br /> DRAFTING: <br />(714) 721 - 4067 <br />Bryan Zamudio <br />Permit Sync Architecture <br />Santa Ana, CA 92704 <br />2614 W Orion Ave <br />permitsync@gmail.com <br />c <br />VACANT <br />DISTRIB. <br />WAREH. <br />11 <br />11 <br />11 <br />11 <br />DISTRIB. <br />WAREH. <br />DISTRIB. <br />WAREH. <br />DISTRIB. <br />WAREH. <br />TOTALS 11 11 <br />N/A <br />b <br />b <br />THERE IS A PARKING SURPLUS OF +0 <br />PARKING SPACES NUMBERED <br />24" <br />Bldg #102122163 <br /> <br />APPROVALS: <br />PLNG - C. Santana <br />BLDG - T. Le <br />POLICE - B. Martin <br />PUBLIC WORKS - Y. Soto <br />HOLD-2903 S <br />Halladay St4/14/2025
The URL can be used to link to this page
Your browser does not support the video tag.