My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
918 S Elliot Pl - Plan
PBA
>
Building
>
ProjectDox
>
E
>
Elliott Pl
>
918 S Elliott Pl
>
918 S Elliot Pl - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/1/2025 12:11:27 PM
Creation date
6/1/2025 12:11:15 PM
Metadata
Fields
Template:
Plan
Permit Number
20179759
101115262
Full Address
918 S Elliott Pl
Document Relationships
101115262 - Permit
(Permit - Plan)
Path:
\Building\Permits\E\Elliott Pl\918 S Elliott Pl
20179759 - Permit
(Permit - Plan)
Path:
\Building\Permits\E\Elliott Pl\918 S Elliott Pl
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
18
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
SCOPE OF WORK: <br />INSTALL (20) Q.CELLS Q.PEAK DUO BLK ML-G10+ 400 SOLAR ELECTRIC <br />MODULES AND (20) SOLAREDGE S440 DC POWER OPTIMIZERS ON THE EXISTING <br />1ST STORY COMPOSITION ROOF. INSTALL ASSOCIATED MOUNTING HARDWARE, <br />JUNCTION BOXES, CONDUIT, CONDUCTORS AND GROUNDING. INSTALL <br /> (1) SOLAREDGE SE7600H-US INVERTER WITH INTEGRATED DC DISCONNECT, <br /> (1) AC DISCONNECT, AND INSTALL OCPD IN MAIN SERVICE PANEL. <br />HOMEOWNER: TAYLOR GELVAN & NATALIE CONGHUYEN <br />PH: 949.701.9256 <br />ADDRESS: 918 S. ELLIOT PLACE <br />SANTA ANA, CA 92704 <br />DATE: 5/9/23DATE: 5/9/23 <br />SUN SOLAR US, INC. <br />16755 VON KARMAN AVENUE #200 <br />IRVINE, CA 92606 <br />PH: 949.242.0088 RONALD RHODES B, C10 - 975072 <br />SYSTEM SIGNAGESYSTEM SIGNAGE <br />ALL SIGNAGE SHALL BE REFLECTIVE, UV RESISTANT <br />PLASTIC, RED IN COLOR WITH WHITE LETTERING, AND <br />ATTACHED WITH WEATHERPROOF ADHESIVE OR <br />OTHER APPROVED METHOD. ALL LETTERS SHALL BE A <br />MINIMUM OF 38" HEIGHT AND ALL CAPITALIZED. <br />ALL CONDUIT, JUNCTION BOXES AND OTHER ENCLOSURES <br />SHALL BE MARKED AT 10' MAX INTERVALS AND AT ALL <br />BENDS, TERMINATIONS, SPLICES OR CONNECTIONS WITH <br />"WARNING: PHOTOVOLTAIC POWER SOURCE". <br />WARNING <br />ELECTRIC SHOCK HAZARD <br />DO NOT TOUCH TERMINALS <br />TERMINALS ON BOTH THE LINE <br />AND LOAD SIDES MAY BE ENERGIZED <br />IN THE OPEN POSITION <br />TO BE INSTALLED AT ALL SERVICEABLE PANELS <br />OR BOXES AND AT ALL DISCONNECTS: <br />WARNING <br />ELECTRIC SHOCK HAZARD <br />THE DC CONDUCTORS OF THIS <br />PHOTOVOLTAIC SYSTEM ARE <br />UNGROUNDED MAY BE ENERGIZED <br />SERVICE POINT & <br />UTILITY METERING <br />PV SYSTEM DISCONNECT <br />FOR UTILITY OPERATION SWITCH <br />CAUTION: <br />POWER TO THIS BUILDING IS ALSO <br />SUPPLIED FROM THE FOLLOWING SOURCES <br />WITH DISCONNECTS AS SHOWN. <br />ADDRESS: 918 S. ELLIOT PLACE, SANTA ANA, CA 92704 <br />SOLAR ARRAY <br />(ON ROOF)N <br />INVERTER & <br />DC DISCONNECT <br />TO BE INSTALLED ON THE OUTSIDE COVER <br />OF THE MAIN SERVICE DISCONNECT: <br />PV SOLAR DC DISCONNECT <br />MAXIMUM VOLTAGE = 480.00 V <br />MAXIMUM CIRCUIT CURRENT = 30.00 A <br />MAXIMUM RATED OUTPUT CURRENT OF THE <br />DC-TO-DC CONVERTER = 15.00 A <br />TO BE INSTALLED ON THE <br />FRONT OF THE DC DISCONNECT: <br />RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM <br />RATED AC OUTPUT CURRENT = 32.00 A <br />NOMINAL OPERATING AC VOLTAGE = 240 V <br />TO BE INSTALLED ON THE <br />FRONT OF THE AC DISCONNECT: <br />WARNING <br />POWER SOURCE OUTPUT CONNECTION - <br />DO NOT RELOCATE THIS OVERCURRENT DEVICE <br />TO BE INSTALLED AT THE BACKFED <br />BREAKER SERVING THE PV SOLAR SYSTEM: <br />TURN RAPID SHUTDOWN <br />SWITCH TO THE <br />"OFF" POSITION TO <br />SHUT DOWN PV SYSTEM <br />AND REDUCE <br />SHOCK HAZARD <br />IN THE ARRAY <br />SOLAR ELECTRIC <br />PV PANELS <br />SOLAR PV SYSTEM EQUIPPED <br />WITH RAPID SHUTDOWN <br />TO BE INSTALLED ON THE FRONT OF THE MAIN SERVICE DISCONNECT: <br />"SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN" SHALL BE <br />BLACK LETTERING ON YELLOW BACKGROUND. THE REMAINDER OF <br />THE SIGN SHALL BE BLACK LETTERING ON WHITE BACKGROUND. <br />SHEET <br />NOTICE: <br />ANY CHANGES TO OR USES OF THESE <br />DOCUMENTS/DRAWINGS WITHOUT THE <br />WRITTEN CONSENT OF JENNIFER KEMME OR <br />SCOTT HARRIS ARE STRICTLY PROHIBITED. <br />4 OF 4 <br />PLANS PREPARED BY: <br />JENNIFER KEMME <br />PH: 909.748.1300 <br />SYSTEM CALCULATIONS: <br />MODULE POWER = 400 W <br />NUMBER OF MODULES IN LONGEST STRING = 10 <br />(10) 400 W = 4000 W <br />OPTIMIZER MAX POWER PER STRING = 6000 W <br />4000 W < 6000 W, OK <br />OPERATING CURRENT = <br />POWER RATING/OPERATING VOLTAGE = <br />4000 W/400 V = 10.00 A <br />OPTIMIZER TO INVERTER TARGET <br />VOLTAGE/OPERATING VOLTAGE = 400 V <br />MAX SYSTEM VOLTAGE (Voc) CONTROLLED BY <br />INVERTER = 480 V <br />SHORT-CIRCUIT CURRENT (Isc) CONTROLLED BY <br />OPTIMIZER = 15.00 A <br />INVERTER MAX OUTPUT CURRENT = 32.00 A <br />32.00 A (1.25) = 40.00 A [Ic], USE 40 A BREAKER <br />MAIN SERVICE PANEL BUS RATING = 200 A <br />MAIN SERVICE PANEL MAIN OCPD = 200 A <br />200 A + 40 A SOLAR OCPD = 240 A <br />200 A BUS (1.2) = 240 A <br />240 A = 240 A, OK WIRE CALCULATIONS: <br />FROM OPTIMIZERS TO INVERTER/DC DISCONNECT: <br />AMBIENT TEMPERATURE = 34°C <br />TEMPERATURE ADDER FOR CONDUIT NOT OFFSET FROM ROOF = 33°C <br />ADJUSTMENT FACTOR PER TABLE 310.15(B)(2)(a) FOR 90°C INSULATED CONDUCTOR AT <br />34°C + 33°C = 67°C = 0.58 <br />Isc = 15.00 A <br />15.00 A/0.58 = 25.86 A <br />NUMBER OF CURRENT CARRYING CONDUCTORS IN CONDUIT = 4 <br />ADJUSTMENT FACTOR PER TABLE 310.15(B)(3)(a) FOR CONDUIT FILL (4-6 CONDUCTORS IN <br />CONDUIT) = 0.80 <br />25.86 A/0.80 = 32.33 A <br />SELECT WIRE SIZE WITH AMPACITY GREATER THAN 32.33 A, USE 10 AWG THWN-2 COPPER <br />WIRE WITH AN AMPACITY OF 40 A <br />SELECT CONDUIT FOR (4) 10 AWG THWN-2 & (1) 8 AWG GROUND = 34" EMT CONDUIT <br />FROM THE INVERTER TO THE MAIN SERVICE PANEL: <br />ADJUSTMENT FACTOR PER TABLE 310.15(B)(2)(a) FOR 90°C INSULATED CONDUCTOR AT <br />34°C = 0.96 <br />Ic = 40.00 A <br />40.00 A/0.96 = 41.67 A <br />SELECT WIRE SIZE WITH AMPACITY GREATER THAN 41.67 A, USE 8 AWG THWN-2 COPPER <br />WIRE WITH AN AMPACITY OF 55 A <br />SELECT CONDUIT FOR (3) 8 AWG THWN-2 & (1) 8 AWG GROUND = 34" EMT CONDUIT <br />74430PV <br />918 S Elliot Pl <br />06/02/23
The URL can be used to link to this page
Your browser does not support the video tag.