Laserfiche WebLink
M <br />34 <br />' <br />- <br />9 <br />" <br />23 <br />' <br />- <br />2 <br />" <br />6'-11" <br />10'-4" <br />11 <br />6 <br />' <br />- <br />1 <br />1 <br />" <br />47'-11" <br />11 <br />6 <br />' <br />- <br />1 <br />1 <br />" <br /> <br />47'-11" <br />91 <br />7 <br /> <br />W <br /> <br />M <br />C <br />F <br />A <br />D <br />D <br />E <br />N <br /> <br />A <br />V <br />E <br /> R <br />E <br />S <br />I <br />D <br />E <br />N <br />C <br />E <br />91 <br />7 <br /> <br />W <br /> <br />M <br />C <br />F <br />A <br />D <br />D <br />E <br />N <br /> <br />A <br />V <br />E <br />, <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />7 <br />Project Name & <br />Address <br />Sheet Size <br />Sheet Number <br />ANSI B <br />11" X 17" <br />PV 0.0 <br />Sheet Name <br />DRAWN BY <br />AP <br />N <br />: <br /> <br />0 <br />1 <br />0 <br />2 <br />6 <br />3 <br />2 <br />5 <br />SHEET INDEX: <br />COVER SHEET <br />SCALE: NTS <br />2 SATELLITE VIEW <br />PV 0.0 <br />SCALE: NTS <br />3 VICINITY MAP <br />PV 0.0 SCALE: 1/16" = 1'-0" <br />1 PLOT PLAN <br />PV 0.0 <br />GENERAL NOTES: <br />a. INSTALLATION OF SOLAR <br />PHOTOVOLTAIC SYSTEM SHALL BE IN <br />ACCORDANCE WITH NEC ARTICLE <br />690, AND ALL OTHER APPLICABLE <br />NEC CODES WHERE NOTED OR <br />EXISTING. <br />b. PROPER ACCESS AND WORKING <br />CLEARANCE AROUND EXISTING AND <br />PROPOSED ELECTRICAL EQUIPMENT <br />WILL COMPLY WITH NEC ARTICLE 110. <br />c. ALL CONDUCTORS, INCLUDING THE <br />GROUNDING ELECTRODE <br />CONDUCTOR SHALL BE PROTECTED <br />FROM PHYSICAL DAMAGE IN <br />ACCORDANCE WITH NEC ARTICLE <br />250. <br />d. THE PV MODULES ARE CONSIDERED <br />NON-COMBUSTIBLE; THIS SYSTEM IS <br />UTILITY INTERACTIVE PER UL 1741 <br />AND ALSO INCLUDE STORAGE <br />BATTERIES OR OTHER ALTERNATIVE <br />STORAGE SOURCES. <br />e. ALL DC WIRES SHALL BE SIZED <br />ACCORDING TO [NEC 690.8] <br />f. DC CONDUCTORS SHALL BE WITHIN <br />PROTECTED RACEWAYS IN <br />ACCORDANCE WITH [NEC 690.31] <br />g. ALL SIGNAGE TO BE PLACED IN <br />ACCORDANCE WITH LOCAL <br />JURISDICTIONAL BUILDING CODE. <br />h. PV MODULES TO BE RATED UL 1703 <br />CLASS C FIRE RATING OR BETTER. <br />i. ALL EQUIPMENT TO BE CERTIFIED BY <br />A NATIONALLY RECOGNIZED TESTING <br />LABORATORY. <br />PROTECTION OF EMERGENCY RESPONDERS <br />ALL SHARP EDGES AND FASTENER TIPS SHALL BE COVERED OR <br />CRIMPED OVER TO ELIMINATE SHARP EDGES, TO MINIMIZE RISK <br />OF INJURY TO EMERGENCY RESPONDERS. <br />ALL ROOF MOUNTED CONDUITS, BOXES, AND EQUIPMENT <br />CROSSING PATHWAYS ARE TO BE CLEARLY IDENTIFIED BY A <br />RED/WHITE REFLECTIVE TAPE OR OTHER APPROVED MATERIAL. <br /> ROOF ACCESS POINT <br />ROOF ACCESS POINT SHALL NOT BE LOCATED IN <br />AREAS THAT DO NOT REQUIRE THE PLACEMENT <br />OF GROUND LADDERS OVER OPENINGS SUCH AS <br />WINDOWS OR DOORS, AND LOCATED AT STRONG <br />POINTS OF BUILDING CONSTRUCTION IN <br />LOCATIONS WHERE THE ACCESS POINT DOES NOT <br />CONFLICT WITH OVERHEAD OBSTRUCTIONS SUCH <br />AS TREE LIMBS, WIRES OR SIGNS. <br />SYSTEM SIZE: 11.520 kW DC <br />3.800 kW AC <br />MODULE TYPE & AMOUNT: (32) PANASONIC EVPV360PK 360W <br />MAIN SERVICE PANEL: EXISTING 100A BUS RATED MAIN PANEL <br />INVERTER: (01) SOLAREDGE ENERGY HUB SE3800H-USSNBBL14 [240V] <br />INTERCONNECTION METHOD: LOAD BREAKER <br />PHOTOVOLTAIC SYSTEM WORK SCOPE: <br />PHOTOVOLTAIC ROOF MOUNT SYSTEM <br />32 MODULES-ROOF MOUNTED - 11.520 kW DC, 3.800 kW AC, 917 W MCFADDEN AVE, SANTA ANA, CA 92707 <br />ROOF ACCESS POINT <br />GOVERNING CODES <br />ALL WORK SHALL CONFORM TO THE FOLLOWING CODES <br />· 2022 CALIFORNIA BUILDING CODE <br />· 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE <br />· 2022 CALIFORNIA EXISTING BUILDINGS CODE <br />· 2022 CALIFORNIA PLUMBING CODE <br />· 2022 CALIFORNIA FIRE CODE <br />· 2022 CALIFORNIA ENERGY CODE <br />· 2022 CALIFORNIA RESIDENTIAL CODE <br />· 2022 CALIFORNIA ELECTRIC CODE <br />· 2020 NATIONAL ELECTRIC CODE <br />EXISTING EXTERIOR MAIN <br />SERVICE PANEL TIED TO <br />EXTERIOR UTILITY METER <br />PV 0.0: COVER SHEET <br />PV 1.0: SITE PLAN <br />S 1.1: MOUNT DETAILS <br />E 1.1: 3-LINE DIAGRAM <br />E 1.2: NOTES <br />E 1.3: WARNING LABELS <br />- EQUIPMENT SPEC SHEET <br />ROOF #1 <br />(11) PANASONIC EVPV360PK 360W <br />SLOPE: 30° <br />AZIM.: 90° <br />GATE <br />MAIN HOUSE <br />FRONT OF HOUSE <br />W MCFADDEN AVE <br />PROPERTY LINE <br />PR <br />O <br />P <br />E <br />R <br />T <br />Y <br /> <br />L <br />I <br />N <br />E <br /> <br />PR <br />O <br />P <br />E <br />R <br />T <br />Y <br /> <br />L <br />I <br />N <br />E <br />PROPERTY LINE <br />DRIVEWAY <br />PA <br />T <br />H <br />W <br />A <br />Y <br />GARAGE <br />FENCE <br />ROOF #2 <br />(6) PANASONIC EVPV360PK 360W <br />SLOPE: 30° <br />AZIM.: 90° <br />ROOF #3 <br />(15) PANASONIC EVPV360PK 360W <br />SLOPE: 30° <br />AZIM.: 270° <br />www. Loyd W Martin .com <br />Solar Structures Engineering <br />#2024-0564 Structural Only <br />April 18, 2024 <br />The scope of the plans is for <br />the installation of the solar <br />photovoltaic system only and <br />the approval is subject to <br />compliance with all <br />applicable city and state <br />codes and regulations <br />regarding construction. The <br />approval of the plans does <br />not constitute any <br />certification of the accuracy, <br />completeness, or building <br />permit status of the existing <br />buildings and structures as <br />shown. <br />Bldg# 101119790 <br />Elec# 20183200 <br />917 W McFadden Ave - <br />101119790 & 201832007/2/2024