My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
403 N Susan St Bldg# E - Plan
PBA
>
Building
>
ProjectDox
>
S
>
Susan St
>
403 N Susan St Bldg# E
>
403 N Susan St Bldg# E - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/5/2025 7:31:27 AM
Creation date
6/5/2025 7:31:18 AM
Metadata
Fields
Template:
Plan
Permit Number
20183212
101119805
Full Address
403 N Susan St Bldg# E
Text box
ID:
1
Creator:
Import Agent
Created:
6/5/2025 7:31 AM
Modified:
6/4/2025 3:22 PM
Text:
403 N SUSAN ST BLDG #E SANTA ANA, CA 92703
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
36
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
ENERGY STORAGE <br />SYSTEM DISCONNECT <br />CODE REFERENCE: NEC 706.15(C) <br />LOCATION: ON ACCESSIBLE ESS DISCONNECT <br />BACKUP LOAD CENTER <br />CODE REFERENCE: NEC 408.4 <br />LOCATION: PLACE ON BACKUP LOAD CENTER <br />CAUTION <br />TRI POWER SOURCE. <br />SECOND SOURCE IS PHOTOVOLTAIC SYSTEM <br />THIRD SOURCE IS ENERGY STORAGE SYSTEM <br />CODE REFERENCE: NEC 705.12(B)(3) <br />LOCATION: PLACE ON MAIN PANEL IF PV <br />SYSTEM IS ALSO CONNECTED TO PANEL <br />WARNING! <br />FUEL CELL POWER SYSTEM <br />CONTAINS ENERGY <br />STORAGE DEVICES <br />CODE REFERENCE: NEC 692.56 <br />LOCATION: ON ACCESSIBLE ESS DISCONNECT <br />CAUTION <br />DO NOT ADD NEW LOADS <br />CODE REFERENCE: NEC 220 <br />LOCATION: PLACE ON BACKUP LOAD CENTER <br />CAUTION <br />THIS PANEL HAS SPLICED FEED- <br />THROUGH CONDUCTORS. <br />LOCATION OF DISCONNECT AT ENERGY <br />STORAGE BACK UP LOAD PANEL. <br />CODE REFERENCE: NEC 312.8(3) <br />LOCATION: PLACE ON MAIN PANEL IF POINT <br />OF INTERCONNECTION IS SUPPLY SIDE <br />BATTERY BACKUP PLACARDS <br />ENERGY STORAGE SYSTEM ON SITE <br />LOCATED WITHIN LINE OF SIGHT <br /> SELECT APPLICABLE STICKER <br />LOCATION: ON MAIN PANEL IF <br />ESS IS IN LINE OF SIGHT <br />ENERGY STORAGE SYSTEM ON SITE <br />LOCATED WITHIN LINE OF SIGHT <br />LOCATION: ON MAIN PANEL IF <br />ESS IS IN LINE OF SIGHT <br />ENERGY STORAGE SYSTEM ON SITE <br />LOCATED WITHIN LINE OF SIGHT <br />LOCATION: ON MAIN PANEL IF <br />ESS IS IN LINE OF SIGHT <br />ENERGY STORAGE SYSTEM ON SITE <br />LOCATED WITHIN LINE OF SIGHT <br />LOCATION: ON MAIN PANEL IF <br />ESS IS IN LINE OF SIGHT <br />WARNING! <br />DO NOT UPSIZE MAIN BREAKER <br />LOCATION: ON MAIN ELECTRICAL PANEL <br />BREAKER WAS DOWNSIZED <br />TO 175A FOR PV SYSTEM <br />WARNING <br />ELECTRIC SHOCK HAZARD <br />TERMINALS ON BOTH LINE AND <br />LOAD SIDES MAY BE ENERGIZED <br />IN THE OPEN POSITION <br />WARNING! <br />POWER SOURCE OUTPUT <br />CONNECTION. DO NOT <br />RELOCATE THIS <br />OVERCURRENT DEVICE <br />CODE REFERENCE: NEC 690.5(C) <br />LOCATION: PLACE ON ALL <br />DISCONNECTING MEANS WHERE <br />ENERGIZED IN AN OPEN POSITION <br />CODE REFERENCE: NEC 705.12(B)(3)(2) <br />LOCATION: AT P.O.C. TO SERVICE <br />DISTRIBUTION EQUIPMENT (I.E. MAIN <br />PANEL AND SUB PANEL IF APPLICABLE) <br />WARNING <br />THIS EQUIPMENT FED BY <br />MULTIPLE SOURCES: <br />TOTAL RATING OF ALL OVERCURRRENT <br />DEVICES, EXCLUDING MAIN SUPPLY <br />OVERCURRENT DEVICE, SHALL NOT <br />EXCEED AMPACITY OF BUSBAR <br />CODE REFERENCE: NEC 705.12(B)(3)(3) <br />LOCATION: AT P.O.C. TO SERVICE <br />DISTRIBUTION EQUIPMENT (I.E. MAIN <br />PANEL AND SUB PANEL IF APPLICABLE) <br />WARNING DUAL POWER SOURCE <br />SECOND SOURCE IS PHOTOVOLTAIC SYSTEM <br />CODE REFERENCE: NEC 690.64(B)(4) <br />LOCATION: ALL EQUIPMENT CONTAINING <br />OVERCURRENT DEVICES IN CIRCUITS <br />SUPPLYING POWER TO A BUSBAR OR <br />CONDUCTORS SUPPLIED FROM <br />MULTIPLE SOURCES <br />PHOTOVOLTAIC POWER SOURCE <br />CODE REFERENCE: NEC 690.31(D)(2) <br />LOCATION: AT EXPOSED RACEWAYS, <br />CABLE TRAYS, AND OTHER WIRING <br />METHODS; SPACED A MAX. 10 FT <br />SECTIONS OR WHERE SEPARATED BY <br />ENCLOSURES, WALLS, PARTITIONS, <br />CEILINGS, OR FLOORS. <br />AC DISCONNECT <br />AC PHOTOVOLTAIC POWER SOURCE <br />MAX AC OPERATING CURRENT: <br />AC OPERATING VOLTAGE: <br /> MAX <br /> VAC240 <br />62.35A <br />CODE REFERENCE: NEC 690.54 <br />LOCATION: AT P.O.C. TO SERVICE <br />DISTRIBUTION EQUIPMENT (I.E. MAIN <br />PANEL AND SUB PANEL IF APPLICABLE) <br />WARNING! <br />PHOTOVOLTAIC SYSTEM <br />COMBINER PANEL <br />DO NOT ADD LOADS. <br />LOCATION: AT PV COMBINER PANEL <br />(IF APPLICABLE) <br />PHOTOVOLTAIC <br />AC DISCONNECT <br />CODE REFERENCE: NEC 690.13(B) <br />LOCATION: AT P.O.C. TO SERVICE DISTRIBUTION <br />EQUIPMENT / AC DISCONNECTS / BREAKERS <br />TURN RAPID SHUTDOWN <br />SWITCH TO THE <br />"OFF" POSITION TO <br />SHUT DOWN PV SYSTEM <br />AND REDUCE <br />SHOCK HAZARD <br />IN THE ARRAY <br />SOLAR ELECTRIC <br />PV PANELS <br />SOLAR PV SYSTEM EQUIPPED <br />WITH RAPID SHUTDOWN <br />CODE REFERENCE: NEC 690.56 <br />LOCATION: SIGN TO BE LOCATED ON OR NO MORE THAN 3 <br />FT AWAY FROM SERVICE DISCONNECTING MEANS TO <br />WHICH THE PV SYSTEMS ARE CONNECTED AND SHALL <br />INDICATE THE LOCATION OF ALL IDENTIFIED RAPID <br />SHUTDOWN SWITCHES IF NOT AT THE SAME LOCATION. <br />RAPID SHUTDOWN SWITCH <br />FOR SOLAR PV SYSTEM <br />CODE REFERENCE: NEC 690.56 (C)(2) <br />LOCATION: TO BE LOCATED ON OR NO <br />MORE THAN 3 FT AWAY FROM RSD <br />INITIATION DEVICE <br />! <br />! <br />! <br />FORMAT <br />1. WHITE LETTERING ON A RED BACKGROUND <br />2. MINIMUM 3/8 INCHES LETTER HEIGHT <br />3. ALL LETTERS SHALL BE CAPITALIZED <br />4. ARIAL OR SIMILAR FONT (NON-BOLD) <br />MATERIAL <br />REFLECTIVE, WEATHER RESISTANT MATERIAL <br />SUITABLE FOR THE ENVIRONMENT <br />(USE UL-969 AS STANDARD FOR WEATHER <br />RATING). DURABLE ADHESIVE MATERIALS. <br />01 <br />02 <br />03 <br />04 <br />05 <br />06 <br />07 <br />08 <br />09 <br />10 <br />INFINITY SOLAR, INC. <br />749 N MAIN ST. <br />ORANGE, CA 92868 <br />PHONE: (714) 880-8089 <br />LIC NO.: C10 - 824287 <br />TIM POLUJANCEWICZ <br />LABELS PV.06 <br />ADDITIONAL NOTES <br />DRAWN BY: <br />PAPER: 11X17 (ANSI B)DATE: <br />DESIGN LEAD: <br />DESIGNED BY SOLAR DEPLOYED, LLC. <br />931 10TH ST #114, MODESTO, CA 95354 <br />209-671-2001 | HELLO@SOLARDEPLOYED.COM <br />SIGNATURE: <br />CHECKED BY: <br />5/23/2024 <br />T.M. <br />C.B.T.M. <br />SHEET NAME: <br />NEW PV SYSTEM <br /> 18.275 kW DC (STC-DC) | 16.642 kW (CEC-AC) <br />SARAH HAMMARSTROM <br />421 N SUSAN ST, <br />SANTA ANA, CA 92703 <br />APN: 198-261-34 <br />SHEET NO.: <br />ENGINEER OF RECORD <br />403 N Susan St Bldg# E - <br />101119805 & 201832129/23/2024