Laserfiche WebLink
Table of Contents <br />Parameters 2 <br />Components and Specifications 3 <br />Loads and Distributions 5 <br />Basic Load Combinations 11 <br />Longitudinal Analysis 13 <br />Column & Backer Analysis 15 <br />Beam Analysis 19 <br />Beam to Column Analysis 25 <br />Bracing Analysis 27 <br />Anchor Analysis 31 <br />Overturning Analysis 37 <br />Baseplate Analysis 39 <br />Slab and Soil Analysis 43 <br />Parameters 45 <br />Components and Specifications 46 <br />Loads and Distributions 48 <br />Basic Load Combinations 54 <br />Longitudinal Analysis 56 <br />Column & Backer Analysis 58 <br />Beam Analysis 62 <br />Beam to Column Analysis 68 <br />Bracing Analysis 70 <br />Anchor Analysis 74 <br />Overturning Analysis 80 <br />Baseplate Analysis 82 <br />Slab and Soil Analysis 86 <br />Scope: <br />This storage system analysis is intended to determine its compliance with appropriate building codes <br />with respect to static and seismic forces. <br />The storage racks are prefabricated and are to be field assembled only, with no field welding. <br />PROJECT: <br />FOR: <br />ADDRESS: <br />SHEET#: <br />CALCULATED BY: <br />DATE: <br />Power Distribution Inc <br />Aztec_steve peterson <br />4011 W. CARRAIGE D <br />SANTA ANA, CA <br />1 <br />kelvira <br />6/19/2024 <br /> TEL:(909)869-0989 <br /> 1130 E. CYPRESS ST, COVINA, CA 91724 <br />PN:20240103_2 <br />4011 W Carriage Dr <br />9/11/2024