Laserfiche WebLink
www.hilti.com <br />Hilti PROFIS Engineering 3.1.11 <br />Input data and results must be checked for conformity with the existing conditions and for plausibility! <br />PROFIS Engineering ( c ) 2003-2025 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan <br />3 <br />Company: <br />Address: <br />Phone I Fax: <br />Design: <br />Fastening point: <br /> | <br />Concrete - Mar 5, 2025 (1) <br />Page: <br />Specifier: <br />E-Mail: <br />Date: <br />3 <br />3/6/2025 <br />3.1 Steel Strength <br />Nsa = ESR value refer to ICC-ES ESR-3027 <br />f Nsa ³ Nua ACI 318-19 Table 17.5.2 <br />Variables <br />Ase,N [in.2]futa [psi] <br />0.09 106,225 <br />Calculations <br />Nsa [lb] <br />9,200 <br />Results <br />Nsa [lb]f steel f Nsa [lb]Nua [lb] <br />9,200 0.650 5,980 127 <br />3.2 Pullout Strength <br />Npn,f' <br />c <br />= Np,2500 l a (fc'/2500)0.5 refer to ICC-ES ESR-3027 <br />f Npn,f' <br />c <br />³Nua ACI 318-19 Table 17.5.2 <br />Variables <br />f' <br />c [psi]l a Np,2500 [lb] <br />3,000 1.000 728 <br />Calculations <br />(fc'/2500)0.5 <br />1.095 <br />Results <br />Npn,f' <br />c <br /> [lb]f concrete <br />f Npn,f' <br />c <br /> [lb]Nua [lb] <br />797 0.650 518 127 <br />24 of 89 <br />3201 S Halladay St <br />5/5/2025