Laserfiche WebLink
www.hilti.com <br />Hilti PROFIS Engineering 3.1.11 <br />Input data and results must be checked for conformity with the existing conditions and for plausibility! <br />PROFIS Engineering ( c ) 2003-2025 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan <br />5 <br />Company: <br />Address: <br />Phone I Fax: <br />Design: <br />Fastening point: <br /> | <br />Concrete - Mar 5, 2025 (1) <br />Page: <br />Specifier: <br />E-Mail: <br />Date: <br />5 <br />3/6/2025 <br />4 Shear load <br />Load Vua [lb]Capacity f Vn [lb]Utilization bV = Vua/f Vn Status <br /> Steel Strength*50 2,202 3 OK <br /> Steel failure (with lever arm)*N/A N/A N/A N/A <br /> Pryout Strength**101 367 28 OK <br /> Concrete edge failure in direction y-**101 2,828 4 OK <br />* highest loaded anchor **anchor group (relevant anchors) <br />When the input edge distance is set to "infinity", edge breakout verification is not performed in that direction <br />4.1 Steel Strength <br />Vsa = ESR value refer to ICC-ES ESR-3027 <br />f Vsteel ³ Vua ACI 318-19 Table 17.5.2 <br />Variables <br />Ase,V [in.2]futa [psi] <br />0.09 106,225 <br />Calculations <br />Vsa [lb] <br />3,670 <br />Results <br />Vsa [lb]f steel f Vsa [lb]Vua [lb] <br />3,670 0.600 2,202 50 <br />26 of 89 <br />3201 S Halladay St <br />5/5/2025