My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3201 S Halladay St - Plan
PBA
>
Building
>
ProjectDox
>
H
>
Halladay St
>
3201 S Halladay St
>
3201 S Halladay St - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/13/2025 6:02:20 AM
Creation date
6/5/2025 7:32:47 AM
Metadata
Fields
Template:
Plan
Permit Number
20183890
30147713
40139478
101120672
101120687
Full Address
3201 S Halladay St
Street Number
3201
Street Direction
S
Street Name
Halladay
Street Suffix
St
Jump to thumbnail
< previous set
next set >
Text box
ID:
1
Creator:
Import Agent
Created:
6/5/2025 7:32 AM
Modified:
6/4/2025 3:12 PM
Text:
www.hilti.com
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
213
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
www.hilti.com <br />Hilti PROFIS Engineering 3.1.11 <br />Input data and results must be checked for conformity with the existing conditions and for plausibility! <br />PROFIS Engineering ( c ) 2003-2025 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan <br />5 <br />Company: <br />Address: <br />Phone I Fax: <br />Design: <br />Fastening point: <br /> | <br />Masonry - Mar 6, 2025 <br />Page: <br />Specifier: <br />E-Mail: <br />Date: <br />5 <br />3/6/2025 <br />4.4 Shear interaction <br />bV,|| = Vs,|| <br />Vt,|| <br />bV,^ = Vs,^ <br />Vt,^d Utilization bV [%]Status <br />0.303 0.000 1.000 31 OK <br />bV = bd <br />V,|| + bd <br />V,^ <= 1.0 <br />5 Combined tension and shear loads (Most utilized anchor 1) <br />bP = Ps <br />Pt <br />bV,|| = Vs,|| <br />Vt,|| <br />bV,^ = Vs,^ <br />Vt,^a Utilization bP,V [%]Status <br />0.298 0.303 0.000 1.000 61 OK <br />bP,V = ba <br />P + ba <br />V,|| + ba <br />V,^ <= 1.0 <br />6 Warnings <br />• The anchor design methods in PROFIS Engineering require rigid anchor plates per current regulations (AS 5216:2021, ETAG 001/Annex C, <br />EOTA TR029 etc.). This means load re-distribution on the anchors due to elastic deformations of the anchor plate are not considered - the <br />anchor plate is assumed to be sufficiently stiff, in order not to be deformed when subjected to the design loading. PROFIS Engineering calculates <br />the minimum required anchor plate thickness with CBFEM to limit the stress of the anchor plate based on the assumptions explained above. The <br />proof if the rigid anchor plate assumption is valid is not carried out by PROFIS Engineering. Input data and results must be checked for <br />agreement with the existing conditions and for plausibility! <br />• The equations presented in this report are based on imperial units. When inputs are displayed in metric units, the user should be aware that the <br />equations remain in their imperial format. <br />• Refer to the manufacturer's product literature for cleaning and installation instructions. <br />• The min. sizes of the bricks, the masonry compressive strength, the type / strength of the mortar and the grout (in case of fully grouted CMU <br />walls) has to fulfill the requirements given in the relevant ESR-approval or in the PTG. <br />• Only the local load transfer from the anchor(s) to the wall is considered, a further load transfer in the wall is not covered by PROFIS! <br />• Wall is assumed as being perfectly aligned vertically – checking required(!): Noncompliance can lead to significantly different distribution of forces <br />and higher tension loads than those calculated by PROFIS. Masonry wall must not have any damages (neither visible nor not visible)! While <br />installation, the positioning of the anchors needs to be maintained as in the design phase i.e. either relative to the brick or relative to the mortar <br />joints. <br />• The effect of the joints on the compressive stress distribution on the plate / bricks was not taken into consideration. <br />• If no significant resistance is felt over the entire depth of the hole when drilling (e.g. in unfilled butt joints), the anchor should not be set at this <br />position or the area should be assessed and reinforced. Hilti recommends the anchoring in masonry always with sieve sleeve. Anchors can only <br />be installed without sieve sleeves in solid bricks when it is guaranteed that it has not any hole or void. <br />• The accessories and installation remarks listed on this report are for the information of the user only. In any case, the instructions for use <br />provided with the product have to be followed to ensure a proper installation. <br />• The compliance with current standards (e.g. 2018, 2015, 2012, 2009 and 2006 IBC) is the responsibility of the user. <br />• Drilling method (hammer, rotary) to be in accordance with the approval! <br />• Masonry should be built according to industry standards. <br />Fastening meets the design criteria! <br />87 of 89 <br />3201 S Halladay St <br />5/5/2025
The URL can be used to link to this page
Your browser does not support the video tag.