1.THE CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR: <br />A.ALL CONTRACT DOCUMENTS. <br />B.OMISSIONS AND/OR CONFLICTS BETWEEN THE VARIOUS ELEMENTS OF THE CONTRACT DOCUMENTS. <br />C.ALL DIMENSIONS AND CONDITIONS AT THE SITE. <br />D.ANY CONDITION WHICH IN HIS OPINION MIGHT ENDANGER THE STABILITY OF THE STRUCTURE. <br />E.INSURING PROPER ALIGNMENT OF FINAL STRUCTURE. <br />THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THE ARCHITECT AND THE STRUCTURAL ENGINEER OF ANY DISCREPANCY <br />OR OMISSION BEFORE PROCEEDING WITH THE WORK. <br />2.ALL WORK SHALL CONFORM TO THE REQUIREMENTS OF ALL REGULATING AGENCIES EXERCISING AUTHORITY OVER <br />ANY PORTION OF THE WORK, I.E. STATE OF CALIFORNIA, DIVISION OF INDUSTRIAL SAFETY AND CAL/OSHA, ETC. AND <br />SHALL CONFORM TO THE CURRENT C.B.C. OR LOCAL CODES. <br />3.ALL WORK SHALL CONFORM TO THE BEST PRACTICE PREVAILING IN THE VARIOUS TRADES COMPRISING THE WORK. <br />4.ANY ASTM DESIGNATIONS SHALL BE AS AMENDED TO DATE. <br />5.THE CONTRACTOR SHALL PROVIDE TEMPORARY ERECTION BRACING AND SHORING FOR ALL STRUCTURAL MEMBERS <br />OR AS REQUIRED FOR STRUCTURAL STABILITY OF THE STRUCTURE DURING ALL PHASES OF CONSTRUCTION. <br />6.SPECIFIC NOTES AND DETAILS SHALL TAKE PRECEDENCE OVER GENERAL NOTES AND TYPICAL DETAILS. <br />7.CONTRACTOR SHALL GIVE DUE AND LEGAL NOTICE TO ADJACENT PROPERTY OWNERS REGARDING THE PROTECTION <br />OF THEIR PROPERTY AND STRUCTURES WHICH MAY BE NECESSARY DUE TO EXCAVATION AND CONSTRUCTION <br />INDICATED ON THESE DRAWINGS IN DUE TIME PRIOR TO START OF EXCAVATION. <br />1.ALL EXISTING FILL, NEAR SURFACE SOFT SOILS, VEGETATION, DEBRIS AND DISTURBED SOILS IN THE STRUCTURE, <br />SLAB, OR PAVEMENT AREAS SHALL BE EXCAVATED, THE EXCAVATED AREAS SHALL BE OBSERVED BY THE SOIL ENGINEER, <br />2. AREAS TO RECEIVE COMPACTED SILL SHALL BE SCARIFIED TO A DEPTH OF AT LEAST 6 INCHES AND MOISTENED, AS <br />REQUIRED TO OBTAIN OPTIMUM MOISTURE. THE SCARIFIED AREAS SHALL BE COMPACTED TO 90% OF THE MAXIMUM <br />LABORATORY DENSITY AS DETERMINED BYE THE ASTM D 1557-70 COMPACTION METHOD. <br />3. THE LOOSE POCKETS OF THE SOIL BELOW THE PROPOSED BOTTOMS OF THE EXCAVATION PLANES SHALL BE <br />EXCAVATED AND RE COMPACTED. THE EXCAVATED AREA SHALL BE INSPECTED AND APPROVED BY THE SOILS ENGINEER <br />PRIOR TO PLACING CONTROLLED, COMPACTED FILL. <br />4. FILL, CONSISTING OF THE SOIL APPROVED BY THE SOILS ENGINEER, SHALL BE PLACED IN CONTROLLED LAYERS WITH <br />APPROVED COMPACTION EQUIPMENT. EACH LAYER SHALL MATERIAL USED THE FIELD DENSITY SHALL BE DETERMINED <br />BY THE ASTM 1556-64 METHOD OR EQUIVALENT. <br />5. THE EXCAVATED, ON SITE CLEAN FILL MATERIAL IS CONSIDERED SATISFACTORY FOR REUSE IN THE CONTROLLED <br />FILL. ALL IMPORTED FILL SHALL BE NONEXPANSIVE AND LARGER THAN 6 INCHES IN DIAMETER SHALL NOT BE USED. <br />UNLESS THEY AREA SUFFICIENTLY BROKEN DOWN. <br />6. OBSERVATION AND FIELD TESTS SHALL BE CARRIED ON DURING GRADING BY THE SOIL ENGINEER TO ASSIST THE <br />CONTRACTOR IN OBTAINING THE REQUIRED DEGREE OF COMPACTION AND THE PROPER MOISTURE CONTENT. WHERE <br />COMPACTION OF LESS THAN 90% IS INDICATED, ADDITIONAL COMPACTIVE EFFORT SHALL BE MADE WITH ADJUSTMENT <br />AND/OR TESTED BYE THE ENGINEERING GEOLOGIST AND/OR REPRESENTATIVE OF: <br />A.PLACEMENT AND COMPACTION OF ANY STRUCTURAL COMPACTED FILL. <br />B.RETAINING WALL BACKDRAIN AND BACKFILL, AND UTILITY TRENCH BACKFILL. <br />C.BOTTOM OF THE EXCAVATION AFTER REMOVAL OF UNSUITABLE MATERIALS. <br />D.FOUNDATION EXCAVATION PRIOR TO FORMING AND POURING. <br />E.TEMPORARY EXCAVATION; AND <br />F.OTHER GEOTECHNICALLY RELATED SITE OPERATIONS. <br />GENERAL SPEC. FOR SITE GRADING & EXCAVATION <br />1.CONCRETE USED IN THE JOB SITE HAVE THE FOLLOWING COMPRESSIVE STRENGHT AT AGE 28 DAYS: <br />LOCATION IN METHOD OF ULTIMATE <br />STRUCTURE PROPORTIONING STRENGTH <br />A. SLAB ON GRADE STANDARD 2500PSI <br />B. WALL FOOTINGS STANDARD 2500PSI <br />C. POST OR COLUMN FOOTINGS STANDARD 2500PSI <br />NOTE: NO INSPECTION REQUIRED ON ALL OF THE ABOVE. <br />2. ALL CONCRETE SHALL BE STONE CONCRETE UTILIZING AGGREGATE CONFORMING TO ASTM C33. CEMENT SHALL BE <br />TYPE 1 OR 11 CONFORMING TO ASTM C 150. <br />3. CONCRETE COVER REINFORCING STEEL SHALL BE AS FOLLOWS, U.N.O.: <br />A. CONCRETE AGAINST EARTH (UNFORMED) ........3" <br />B. CONCRETE AGAINST EARTH (UNFORMED) .........2" <br />4. BEFORE CONCRETE IS PLACED TH ECONTRACTOR SHALL COORDINATE AND CHECK WITH ALL TRADES TO ENSURE <br />THE PROPER PLACEMENT OF ALL OPENINGS, SLEEVES, INSERTS, CURBS, DEPRESSIONS, ETC., RELATING TO THE WORK, <br />AS SHOWN IN THE DRAWINGS. ANY CHANGE OR DISCREPANCY SHALL BE APPROVED BY THE STRUCTURAL ENGINEER <br />AND THE LOCAL BUILDING AGENCY PRIOR TO PLACING OF CONCRETE. <br />5. ALL CONCRETE WITH A COMPRESSIVE STRENGTH IN EXCESS OF 2500 PSI AT 28 DAYS SHALL BE PLACED UNDER THE <br />SUPERVISION OF A DEPUTY-INSPECTOR LICENSED BYE THE LOCAL BUILDING OFFICIAL. <br />6. PLACEMENT DRAWINGS FOR REINFORCING STEEL SHALL BE PROVIDED AT THE JOB SITE A MINIMUM OF ONE WORKING <br />DAY PRIOR TO PLACING OF REINFORCING STEEL. <br />7. CONCRETE QUALITY, INSPECTION AND TESTS SHALL CONFORM TO THE LOCAL BUILDING CODE REQUIREMENTS FOR <br />CONCRETE DESIGNED BYE ULTIMATE STRENGTH METHOD. <br />8. ALL CONCRETE MIXES SHALL CONFORM TO THE PROPORTIONS ESTABLISHED BYE CODE FOR THE VARIOUS CONCRETE <br />STRENGTHS REQUIRED FOR THE WORK. CONTRACTOR SHALL ENGAGE A CERTIFIED INDEPENDENT TESTING <br />LABORATORY TO PREPARE MIX DESIGNS FOR THE WORK. COPIES OF SUCH MIX DESIGN, AS WELL AS 7 DAY AND 28 DAY <br />CYLINDERS TEST RESULTS SHALL BE SENT TO THE STRUCTURAL ENGINEER AND THE METHOD II US REQUIRED OPTIONAL <br />FOR OTHERS. <br />1.FOUNDATION ENGINEER SHALL INSPECT FOOTING EXCAVATIONS TO VERIFY DEPTHS <br />PRIOR TO PLACEMENT OF FORMS AND/OR REINFORCING STEEL. <br />2. ALL BACKFILL SHALL BE RECOMPACTED UNDER THE SUPERVISION OF THE FOUNDATION ENGINEER TO 90% OF <br />MAXIMUM DENSITY. <br />3. FOR SOUL INFORMATION, WHICH IS PART OF THE CONTRACT DOCUMENTS, REFER TO SOIL REPORT, IF APPLICABLE, AS <br />REQUIRED FOR RECOMMENDATIONS. <br />4. ALLOWABLE BEARING PRESSURE = 1000 PSF <br />FOUNDATIONS <br />1.CONCRETE BLOCK UNITS SHALL BE MEDIUM WEIGHT GRADE "N" UNITS ("OPEN END" BLOCKS) CONFORMING TO ASTM <br />C90. REFER TO ARCHITECTURAL DRAWINGS AND/OR SPECIFICATIONS FOR BLOCK SIZE, FACE, COLOR, JOINTING, ETC. <br />(f'm=1500psi) <br />2. BLOCK UNITS SHALL BE SUFFICIENTLY MOIST AT TIME OF LIVING TO PREVENT DEHYDRATION OF MORTAR AND GROUT <br />AND SHALL BE FREE OF ALL SUBSTANCES WHICH MIGHT IMPAIR THE BOND OF THE UNITS TO MORTAR AND GROUT. <br />3. MORTAR SHALL BE MACHINE MIXED TYPE "S" MIX CONSISTING OF, BY VOLUME 1 PART CEMENT, 1 <br />4 PART TO 1 <br />2 LIME <br />PUTTY, AND DAMP LOOSE AGGREGATE NOT LESS THAN 2-1/4 NOR MORE THAN 3 TIMES THE SUM OF THE VOLUMES OF <br />CEMENT AND LIME PUTTY USED. <br />4. GROUT SHALL BE MACHINE MIXED BY VOLUME AND CONSIST OF 1 PART CEMENT, 2 TO 3 PARTS SAND WITH 1 <br />10 PART <br />LIME PUTTY. GROUT SPACE MORE THAN 4 INCHES IN WIDTH MAY HAVE IN ADDITION TO THE SAME NOT MORE THAN 2 <br />PARTS PEA GRAVEL. <br />5. CEMENT FOR MORTAR AND GROUT SHALL BE LOW ALKALI TYPE CONFORMING TO ASTM C150. <br />6. MORTAR AND GROUT SHALL HAVE AN ULTIMATE COMPRESSIVE STRENGTH AT AGE 28 DAYS OF: <br /> MORTAR 1800 PSI <br /> GROUT 2000 PSI <br />7. CONTINUOUS INSPECTIONS IS NOT REQUIRED FOR ALL CONCRETE BLOCK WALLS UNLESS NOTED ON DRAWINGS. <br />8. GROUT SOLID ALL CORES WITH REINFORCING TYPICAL. SOLID GROUT CALLED OUT ON PLANS IF REQUIRED. <br />CONCRETE MASONRY UNITS <br />1.ALL LUMBER SHALL BE STRESS GRADE DOUGLAS FIR (COAST REGION) UNLESS OTHERWISE NOTED. <br />A. 2x4 & 3x4 STUDS............................................................................................................................ STUD GRADE <br />B. ROOF JOIST & 2x6 STUDS .....................................D.F. NO. 2 J&P...............................................900 PSI <br />C. ROOF JOIST & 2x6 STUDS .....................................D.F. NO.2 J&P .............................................1000 PSI <br />D. ALL BEAMS ..............................................................D.F. NO.1 J&P .............................................1000 PSI <br />E. BEAMS GRATER THAN 5" THICK .........SELECT STRUCT, B & S ...............................................1450 PSI <br />F. POSTS ......................................................................D.F. NO.1 P&T ................................................925 PSI <br />2. ALL WOOD IN DIRECT CONTACT WITH THE GROUND, MASONRY OR CONCRETE SHALL BE TREATED WITH A <br />PRESERVATIVE, OR SHALL BE DECAY RESISTENT WOOD AS PRESCRIBED IN DIVISION 31 (WOOD PRESERVATIVE). <br />3. ALL WALLS SHALL BE BOLTED TO FOUNDATION (CONCRETE OR CONCRETE BLOCK) WITH 5 <br />8" Ø ANCHOR BOLTS WITHIN <br />12" OF THE ENDS OF EACH WALL PANEL AND NOT MORE THAN 6'-0" O.C. WITH 3" x 3" x 1 <br />4" PLATE WASHERS OR 7 <br />32" Ø <br />SHOT PINS AT 3'-0" O.C., EXCEPT AS CALLED OUT FOR SHEAR WALLS. <br />4. A DOUBLE PLATE MADE OF TWO MEMBERS OF THE SAME WIDTH AS THE STUDS SHALL BE PLACED AT THE TOP OF <br />EVERY BEARING PARTITION OR EXTERIOR WALL. SUCH DOUBLE PLATES SHALL BE LAPPED AT CORNER, AND JOINTS, IN <br />UPPER AND LOWER MEMBERS, SHALL BE AT LEAST FOUR FEET APART, EXCEPT AT CORNERS. <br />5. EXTERIOR WALLS AND BEARING PARTITIONS SHALL BE FRAMED OF 2x4 STUDS @ 16" O.C. WHEN SUPPORTING LOADS <br />FORM ROOF AND A MAXIMUM OF ONE FLOOR ABOVE AND SHALL BE FRAMED OF 3X4 OR 2x6 STUDS @ 16" O.C. WHEN <br />SUPPORTING LOADS FROM ROOF AND TWO OR MORE FLOORS ABOVE UNLESS OTHERWISE NOTED ON DRAWING. AT <br />STAGGERED STUD WALLS USE 2x4 @16" EA. SIDE TYPICAL @ ALL FLOORS UNLESS NOTED OTHERWISE (SEE PLANS). <br />6. EVERY WOOD STUD BEARING WALL OR BEARING PARTITION SHALL BE BRACED AT EACH END OR AS NEAR AS <br />POSSIBLE, AN AT LEAST EVERY 25 FEET OF ITS LENGTH. THE TYPE OF BRACING SHALL MEET THE CODE REQUIREMENTS <br />FOR THIS PURPOSE. <br />7. FLOOR JOIST SHALL BE DOUBLED UNDER PARTITIONS RUNNING PARALLEL TO THE JOIST. USE DOUBLE STUDS OR <br />4X4 POSTS UNDER DOUBLE JOISTS OR 4x BEAMS, UNLESS OTHERWISE CALLED FOR ON FRAMING PLANS. <br />8. ALL NAILING SHALL BE DONE IN ACCORDANCE WITH THE MINIMUM REQUIREMENTS (TABLE 2304.10.1) LOCAL BUILDING <br />CODE, EXCEPT AS OTHERWISE SHOWN, AND SHALL BE DONE WITH COMMON WIRE NAILS UNLESS OTHER TYPE OF NAIL IS <br />ALLOWED BY THE 2022 CBC (SEE ALSO PLYWOOD NOTES.) <br />9. BOLTS SHALL BE UNFINISHED BOLTS CONFORMING TO ASTM A-307. <br />10. PLYWOOD SHALL BE INTERIOR TYPE WITH EXTERIOR GLUE CONFORMING TO "PSI-1-09/PS 2-10" OF GRADE CALLED FOR BELOW. <br />LAID WITH FACE GRAIN PERPENDICULAR TO SUPPORTS, USE COMMON NAILS ONLY UNLESS OTHERWISE APPROVED BY <br />THE STRUCTURAL ENGINEER AND LOCAL BUILDING OFFICIAL. <br />A. ROOF SHEATHING SHALL BE: 1 <br />2" PLYWOOD, STRUCT. I NAILED WITH 8d NAILS @ 6" O.C. AT ALL DIAPHRAGM AND <br />WALL BOUNDARIES. CONTINUOUS PANEL EDGES ARE NOT BLOCKED, 8d NAILS 6" O.C. AT PLYWOOD PANEL EDGES AND 8d <br />NAILS @ 12" O.C. TO INTERMEDIATE SUPPORTS. INDEX #24/0. <br />B. FLOOR SHEATHING SHALL BE 5/8" PLYWOOD, (T&G), NAILED WITH 10d NAILS AT 6" O.C. AT ALL DIAPHRAGM AND WALL <br />BOUNDARIES. CONTINUOUS PANEL EDGES ARE NOT BLOCKED, 10d NAILS @ 6" O.C. AT PLYWOOD PANEL EDGES AND 10d <br />NAILS @10" O.C. TO INTERMEDIATE SUPPORTS. INDEX #32/16. <br />C. PLYWOOD SHEATHING SHALL BE INSPECTED AND APPROVED BY BUILDING INSPECTOR PRIOR TO COVERING WITH <br />FLOOR OR ROOF MATERIAL. <br />D. SOLID BLOCKING AT EDGES REQUIRED FOR PLYWOOD ONLY WHERE CALLED FOR N DRAWING. <br />WOOD FRAMING <br />1.STRUCTURAL STEEL ROLLED SECTIONS AND PLATE USED IN THE WORK SHALL CONFORM TO ASTM A36. <br />2.PIPE COLUMNS SHALL BE WELDED SEAMLESS PIPE CONFORMING TO ASTM 153 FOR GRADE "B" PIPE. <br />3.SQUARE OR RECTANGULAR TUBES SHALL BE WELDED SEAMLESS SECTIONS MADE OF STEEL CONFORMING TO ASTM <br />A500 GR "B". <br />4. ALL FABRICATION SHALL BE DONE IN THE SHOP OF A FABRICATOR LICENSED BYE IR ACCEPTABLE TO THE CITY OF <br />OR UNDER THE CONTINUOUS INSPECTION OF A REGISTERED DEPUTY INSPECTOR LICENSED BY THE SAME BODY. <br />5. ALL STRUCTURAL STEEL EXCEPT THAT PORTION TO BE EMBEDDED IN CONCRETE SHALL RECEIVE ONE SHOP COAT OF <br />PAINT AS DESCRIBED IN THE SPECIFICATIONS. <br />6. SHOP DRAWINGS SHALL BE SUBMITTED TO THE ARCHITECT AND STRUCTURAL ENGINEER FOR APPROVAL PRIOR TO <br />FABRICATION. ANY FABRICATION DONE PRIOR TO RECEIPT OF APPROVED SHOP DRAWINGS SHALL BE DONE AT THE CONTRACTOR'S <br />OWN RISK. <br />7. BOLTED CONNECTIONS USED IN THE WORK SHALL CONSIST OF UNFINISHED BOLTS CONFORMING TO ASTM A307. <br />8. CONTRACTOR SHALL PROVIDE BRACING AS REQUIRED TO MAINTAIN THE ALIGNMENT OF THE BUILDING FRAME UNTIL <br />ALL WELDING IS COMPLETED AND/OR SLABS AND WALLS AREA POURED. <br />STRUCTURAL STEEL <br />1.ALL WELDING SHALL BE PERFORMED BY WELDERS HOLDING CURRENT CERTIFICATES FROM THE CITY OF <br />ALL WELDING SHALL BE PERFORMED USING THE ELECTRICAL ARC PROCESS IN ACCORDANCE WITH APPLICABLE PORTIONS OF THE <br />"CODE <br />FOR ARC AND AS WELDING IN BUILDING CONSTRUCTION OF THE AMERICAN WELDING SOCIETY". <br />2. CONTINUOUS INSPECTION IS REQUIRED FOR FIELD WELDING OF STRUCTURAL STEEL. <br />3. CONTINUOUS INSPECTION IS REQUIRED FOR WELDING OF REINFORCING STEEL. <br />4. ELECTRODES SHALL BE E70XX. <br />WELDING <br />1. GLUED LAMINATED BEAMS SHALL BE FABRICATED IN THE SHOP OF A FABRICATOR LICENCED BY THE LOCAL BUILDING <br />OFFICIAL. EACH BEAM SHALL HAVE AN IDENTIFYING NUMBER AND SHALL BE ACCOMPANIED BYE A CERTIFICATE OF <br />INSPECTION ISSUED BYE AN APPROVED INSPECTION OR TESTING AGENCY. <br />2. REFER TO ARCHITECTURAL DRAWINGS FOR APPEARANCE GRADE. FINISH, ETC. <br />3. ALL GLUED LAMINATED BEAMS SHALL BE FABRICATED OF STRESS GRACED DOUGLAS FIR LUMBER UTILIZING <br />COMBINATION "24F-V8 DF/DF." (2400 PSI). <br />4. GLUE SHALL BE EXTERIOR TYPE CONFORMING TO FEDERAL SPECIFICATION MIL A 397B OR MIL A-5534A. <br />5. REFER TO DRAWING FOR CAMBERS. <br />6. CONTRACTORS SHALL SUBMIT SHOP DRAWINGS OF GLUED LAMINATED BEAMS FOR APPROVAL PRIOR TO <br />FABRICATION. <br />7. THE MAX. MOISTURE CONTENT OF THE WOOD AT THE TIME OF GLUING SHALL NOT EXCEED 14% NOR LESS THAN 7%. <br />8. BEAM SHALL BE "INDUSTRIAL" APPEARANCE GRADE. <br />9. MATERIALS MANUFACTURE AND QUALITY CONTROL SHALL BE IN CONFORMANCE WITH COMMERCIAL STANDARD, <br />CS-253" STRUCTURAL GLUED LAMINATED TIMBER". <br />GLUED LAMINATED BEAMS <br />1. LARR#25202 (ICC-ESR-1387) <br />2. LATERAL SUPPORT IS REQUIRED AT ALL BEARING, POINT AND ALONG <br />COMPRESSION EDGE AT INTERVALS OF 24" O.C. OR CLOSER. <br />3. E = 2.0 x 10 psi (u.o.n) Fb=2,900 psi Fc=650 psi FcH=2,900 psi <br />4. PSL ARE MADE WITHOUT CAMBER, IN ADDITION TO COMPLYING WITH <br />THE DEFLECTION LIMITS OF THE APPLICABLE BLDG. CODE. (2022 CBC) <br />PARALLAM (PSL) - - / TRUSS JOIST MAC MILLAM <br />1. A. ALL REINFORCING STEEL SHALL BE NEW STOCK DEFORMED BARS CONFORMING TO ASTM A615, GRADE 40, UNLESS <br />NOTED OTHERWISE ON DRAWINGS. <br />2. ALL BARS SHALL BE FREE OF RUST. GREASE, MILL SCALE OR ANY MATERIAL WHICH MIGHT AFFECT ITS BOND TO <br />CONCRETE. <br />3. ALL BAR BLENDS SHALL BE MADE COLD. <br />4. BAR LAPS SHALL BE MADE AWAY FROM POINTS OF MAXIMUM STRESS OR AT LOCATIONS SHOWN ON THE DRAWINGS <br />AND AS INDICATED BELOW. THE MINIMUM AMOUNT OF ANY LAP SHALL BE 2 FEET FOR CONCRETE AND 40 DIAMETERS FOR <br />CONCRETE BLOCK MASONRY UNLESS NOTED OTHERWISE. <br />5. ALL TESTING OF REINFORCING STEEL SHALL BE AS REQUIRED BY LOCAL BUILDING CODE OR AS OTHERWISE NOTED IN <br />THE SPECIFICATIONS. <br />6. PRIOR WELDING PROCEDURE APPROVAL IS REQUIRED FOR WELDING OF GRADE 60 REINFORCING STEEL. <br />REINFORCING STEEL <br />STRUCTURAL NOTES <br />GENERAL: <br />CONCRETE <br />SHEET: <br />JOB No: <br />DATE: <br />DRAWN BY: <br />PLAN: <br />PHONE: <br />JOB SITE: <br />PROJECT NAME: <br />REVISION:BY: <br />GALIDO <br />RESIDENCE <br />23-074 <br />08-12-2024 <br />R.B. <br />310-658-2071 <br />2805 N OLIVE LN, <br />SANTA ANA CA 92706 <br />APPROVED BY :O.V. <br />d e s i g n e r <br />O s c a r V e g a <br />S-1 <br />STRUCTURAL <br />NOTES <br />STRUCTURAL PLANS BY: <br />NEWPORT <br />E & C INC. <br />ANDREW KASHE <br />17011 INDEPENDENCE WAY <br />YORBA LINDA, CA 92886 <br />CELL: 909-610-5409 <br />C I V I L <br />SIGNED: 05 / 28 / 24 <br />EXP. 12-31-24 <br />ANDREW KASHE <br />R <br />E <br />G <br />I <br />STERED PRO F E S S IONAL ENG <br />I <br />N <br />E <br />E <br />R <br />STATE OF C A L IFORNIA <br />C94117 <br />2805 N Olive Ln <br />11/18/2024