My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2805 N Olive Ln - Plan
PBA
>
Building
>
ProjectDox
>
O
>
Olive Ln
>
2805 N Olive Ln
>
2805 N Olive Ln - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/5/2025 7:33:02 AM
Creation date
6/5/2025 7:32:50 AM
Metadata
Fields
Template:
Plan
Permit Number
101119827
Full Address
2805 N Olive Ln
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
55
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
A.WALK-IN CLOSET WITH AN AREA GREATER THAN 70 FT² WILL BE PROVIDED WITH <br />DIMMER SWITCHES FOR LIGHTING [CRnC 150.0(k)J]. <br />B.OUTDOOR LUMINARIES SHALL BE CONTROLLED BY PHOTOCELL AND MOTION <br />SENSOR, OR OTHER METHOD AS PERMITTED BY [CEnC 150.0(k)3A]. <br />C.CEILING RECESSED LED DOWNLIGHTS SHALL BE REQUIRED TO BE APPENDIX JA8 <br />COMPLIANT [CEnC 150.0(k)1]. <br />D.ALL 120-VOLT, SINGLE-PHASE, 15- AND 20-AMPERE BRANCH CIRCUITS SUPPLYING <br />OUTLETS OR DEVICES INSTALLED IN DWELLING UNIT KITCHENS, LIVING ROOMS, <br />BEDROOMS, CLOSETS, LAUNDRY AREAS, OR SIMILAR ROOMS OR AREAS SHALL BE <br />AFCI PROTECTED BY ANY OF THE MEANS DESCRIBED IN 210.12(A)(1) THROUGH (6). <br />E.IN EACH ATTACHED GARAGE WITH ELECTRIC POWER, AT LEAST ONE RECEPTACLE <br />OUTLET SHALL BE INSTALLED IN EACH VEHICLE BAY AND NOT MORE THAN 1.7 M (5 <br />½ FT.) ABOVE THE FLOOR. CEC 210.52 (G) (1) <br />F.ELECTRICAL RECEPTACLE OUTLETS, SWITCHES AND CONTROLS INTENDED TO BE <br />USED BY OCCUPANTS SHALL BE LOCATED NO MORE THAN 48” MEASURED FROM <br />THE TOP OF THE OUTLET BOX AND NOT LESS THAN 15” MEASURED FROM THE <br />BOTTOM OF THE OUTLET BOX ABOVE THE FINISH FLOOR. <br />G.DOORBELL CONTROLS TO NOT EXCEED 48” ABOVE EXTERIOR FLOOR, MEASURED <br />FROM THE TOP OF THE DOORBELL BUTTON ASSEMBLY. <br />H.ALL LIGHTING TO BE HIGH EFFICACY. CENERGYC 150.0(K)1(A). <br />I.IN BATHROOMS, GARAGES, LAUNDRY ROOMS, AND UTILITY ROOMS, AT LEAST ONE <br />LUMINAIRE IN EACH OF THESE SPACES MUST BE CONTROLLED BY AN OCCUPANCY <br />OR VACANCY SENSOR. CENC §150.0(K)2I. <br />J.LUMINAIRES THAT ARE OR CONTAIN LIGHT SOURCES THAT MEET REFERENCE JOINT <br />APPENDIX JA8 REQUIREMENTS FOR DIMMING, AND THAT ARE NOT CONTROLLED BY <br />OCCUPANCY OR VACANCY SENSORS MUST HAVE DIMMING CONTROLS EXCEPT IN <br />CLOSETS LESS THAN 70 SQUARE FEET OR HALLWAYS. CENC §150.0(K)2J. <br />K.FOR SINGLE-FAMILY RESIDENTIAL BUILDINGS, OUTDOOR LIGHTING PERMANENTLY <br />MOUNTED TO A RESIDENTIAL BUILDING OR TO OTHER BUILDINGS ON THE SAME LOT <br />MUST MEET THE REQUIREMENT IN ITEM A AND THE REQUIREMENTS IN ITEM A AND <br />THE REQUIREMENTS IN EITHER ITEM B OR ITEM C: <br />1.CONTROLLED BY A MANUAL ON AND OFF SWITCH THAT PERMITS THE <br />AUTOMATIC ACTIONS OF ITEMS B OR C BELOW; AND <br />2.CONTROLLED BY PHOTOCELL AND EITHER A MOTION SENSOR OR AN AUTOMATIC <br />TIME SWITCH; OR <br />3.CONTROLLED BY AN ASTRONOMICAL TIME CLOCK CONTROL. CENC §150.0(K)3A. <br />L.IN ADDITION TO THE LOCAL EXHAUST FANS IN THE BATHROOMS AND KITCHENS, AN <br />EXHAUST FAN SHALL BE SIZED TO PROVIDE VENTILATION FOR THE WHOLE HOUSE. <br />THE MINIMUM VENTILATION RATE FOR THE IAQ FAN SHALL BE CALCULATED <br />ACCORDING TO ASHRAE STANDARD 62.2 AND 150.0(o)C / 160.2. ONE OF THE <br />LOCAL EXHAUST FAN IN THE BATHROOMS OF KITCHENS MAY BE USED TO MEET THE <br />WHOLE-BUILDING VENTILATION, PROVIDED THE EXHAUST FAN MEETS THE MINIMUM <br />VENTILATION RATED FOR BOTH THE LOCAL EXHAUST AND IAQ REQUIREMENTS. THE <br />DUCTING FOR THE WHOLE BUILDING EXHAUST FAN SHALL BE SIZED ACCORDING TO <br />TABLE 150.0-H / 160.2-H, AND THIS EXHAUST FAN SHALL OPERATE CONTINUOUSLY. <br />ELECTRICAL LEGEND <br />ELECTRICAL & MECHANICAL NOTES: <br />NEW OUTDOOR CEILING FAN <br />NEW DUPLEX RECEPTACLE WITH GFCI PROTECTION <br />NEW SWITCH <br />"UL LISTED " NEW LED RECESSED LIGHT (HIGH-EFFICACY) <br />NEW LED PENDANT LIGHT (HIGH-EFFICACY) <br />NEW SWITCH W/ OCCUPANCY SENSOR <br />NEW AFCI DUPLEX RECEPTACLE OUTLET <br />NEW SWITCH 3 WAY <br />NEW EXTERIOR WATER PROOF OUTLET <br />OS <br />GFCI <br />AFCI <br />3 <br />WP <br />S <br />S <br />S <br />P <br />NEW LED WALL MOUNT LIGHT WITH PHOTOCELL SENSOR (HIGH-EFFICACY) <br />SUITABLE FOR WET LOCATIONS. <br />NEW SWITCH W/DIMMERD <br />NEW LED WALL MOUNT LIGHT <br />(HIGH-EFFICACY) <br />NEW SWITCH W/ MOTION SENSORMS <br />S <br />PS <br />NEW LED WALL MOUNT LIGHT WITH MOTION SENSOR (HIGH-EFFICACY) <br />SUITABLE FOR WET LOCATIONS. <br />S <br />MS <br />NOTE:RECESSED LUMINARIES SHALL FIXTURES BE LISTED <br />FOR ZERO CLEARANCE INSULATION CONTACT (IC) <br />NEW LED RECESSED LIGHT (HIGH-EFFICACY) <br />SUITABLE FOR WET LOCATIONS <br />DUCTLESS MINI-SPLIT AIR CONDITIONER INDOOR UNIT WALL MOUNTED <br />CAPABLE OF MAINTAINING A ROOM TEMPERATURE OF 68° F <br />SEE ADDITIONAL SPECIFICATION IN TITLE REPORT <br />SYMBOL LEGEND <br />WHOLE-BUILDING IAQ VENTILATION EXHAUST FAN THAT WILL OPERATE <br />CONTINUOUSLY AND IS REQUIRED TO BE RATED FOR SOUND AT A <br />MAXIMUM OF 1 SONE. THIS EXHAUST FAN CAN BE CONTROLLED BY A <br />STANDARD ON/OFF SWITCH BUT THE SWITCH MUST BE LABELED <br />CLEARLY DISPLAYING THE FOLLOWING TEXT, OR EQUIVALENT: "THIS <br />SWITCH CONTROLS THE INDOOR AIR QUALITY VENTILATION FOR THE <br />HOME. LEAVE SWITCH IN THE 'ON' POSITION AT ALL TIMES UNLESS THE <br />OUTDOOR AIR QUALITY IS VERY POOR." [150.0(O)J]. <br />CFM SHALL BE : 80 (PER ENERGY REPORT) <br />ELECTRICAL PLAN1 <br />SCALE: 1/4" = 1'-0" <br />(E)2-CAR GARAGE <br />FI <br />R <br />E <br />P <br />L <br />A <br />C <br />E <br />VA <br />U <br />L <br />T <br />E <br />D <br />CE <br />I <br />L <br />I <br />N <br />G <br />CE <br />I <br />L <br />I <br />N <br />G <br />HT <br />. <br /> <br />8 <br />' <br />- <br />0 <br />" <br />PR <br />O <br />P <br />E <br />R <br />T <br />Y <br /> <br />L <br />I <br />N <br />E <br />N <br />AD <br />D <br />I <br />T <br />I <br />O <br />N <br />EX <br />I <br />S <br />T <br />I <br />N <br />G <br />AD <br />D <br />I <br />T <br />I <br />O <br />N <br />EX <br />I <br />S <br />T <br />I <br />N <br />G <br />LED STRIP LIGHT <br />PR <br />O <br />P <br />E <br />R <br />T <br />Y <br /> <br />L <br />I <br />N <br />E <br />LE <br />D <br /> <br />S <br />T <br />R <br />I <br />P <br /> <br />L <br />I <br />G <br />H <br />T <br />P <br />EF <br />SD <br />SD <br />EF <br />RH <br />3/ <br />D <br />S <br />3/ <br />D <br />S <br />3S <br />3S <br />S <br />S S <br />PS <br />PS <br />S <br />SS <br />3S <br />S <br />3S3S <br />3S <br />S <br />SSS <br />GFCI <br />AF <br />C <br />I <br />WP <br />WP <br />AFCI AFCI <br />AF <br />C <br />I <br />AF <br />C <br />I <br />AF <br />C <br />I <br />AFCI <br />AFCI AFCI <br />AF <br />C <br />I <br />AF <br />C <br />I <br />AFCI <br />GFCI <br />GF <br />C <br />I <br />GF <br />C <br />I <br />AF <br />C <br />I <br />AF <br />C <br />I <br />AF <br />C <br />I <br />AFCI <br />GFCI <br />GF <br />C <br />I <br />GF <br />C <br />I <br />GF <br />C <br />I <br />GF <br />C <br />I <br />GF <br />C <br />I <br />GFCI <br />EXHAUST DUCT TERMINATION <br />AIR DUCTS SHALL EXHAUST 3’-0” FROM <br />PROPERTY LINE AND 3’-0” FROM OPENINGS <br />INTO THE BUILDING. CMC 504.5 <br />DUCTING FOR EXHAUST FAN SHALL BE <br />SIZED ACCORDING TO ASHRAE STANDARD <br />62.2 TABLE 7.1 <br />EXHAUST DUCT TERMINATION. <br />AIR DUCTS SHALL EXHAUST 3’-0” FROM <br />PROPERTY LINE AND 3’-0” FROM OPENINGS <br />INTO THE BUILDING. CMC 504.5 <br />EXHAUST DUCT TERMINATION. <br />AIR DUCTS SHALL EXHAUST 3’-0” FROM <br />PROPERTY LINE AND 3’-0” FROM OPENINGS <br />INTO THE BUILDING. CMC 504.5 <br />SD CM <br />SD <br />OS <br />OS <br />OS <br />A.ADDS AUTO-OFF CONTROLS FOR LIGHTING IN DRAWERS AND CABINETS <br />B.UNDERSHELF. DISPLAY CABINETS, SWITCHED OUTLETS CONTROLLED SEPARATE <br />FROM CEILING LIGHTING <br />C.LIGHTING IN HABITABLE SPACE SHALL HAVE ACCESSIBLE WALL-MOUNTED DIMMING <br />CONTROLS <br />INDOOR LIGHTING CONTROL NOTES: <br />NA <br />T <br />U <br />R <br />A <br />L <br /> <br />G <br />A <br />S <br /> <br />R <br />A <br />N <br />G <br />E <br />+ <br />H <br />O <br />O <br />D <br /> <br />( <br />1 <br />8 <br />0 <br /> <br />c <br />f <br />m <br />) <br />HOOD SYSTEM VENTED TO OUTDOORS <br />TABLE 150.0-G: <br />DWELLING UNIT <br />FLOOR AREA (ft²) <br />>1500 <br />HOOD OVER <br />ELECTRIC RANGE <br />HOOD OVER NATURAL <br />GAS RANGE <br />>1000-1500 <br />750-1000 <br /><750 <br />110 cfm <br />110 cfm <br />130 cfm <br />160 cfm <br />180 cfm <br />250 cfm <br />280 cfm <br />280 cfm <br />SHEET: <br />JOB No: <br />DATE: <br />DRAWN BY: <br />PLAN: <br />PHONE: <br />JOB SITE: <br />PROJECT NAME: <br />REVISION:BY: <br />GALIDO <br />RESIDENCE <br />23-074 <br />08-12-2024 <br />R.B. <br />310-658-2071 <br />2805 N OLIVE LN, <br />SANTA ANA CA 92706 <br />APPROVED BY :O.V. <br />d e s i g n e r <br />O s c a r V e g a <br />A-2.5 <br />PROPOSED ROOF <br />PLAN <br />2805 N Olive Ln <br />11/18/2024
The URL can be used to link to this page
Your browser does not support the video tag.