Laserfiche WebLink
VICINITY MAP <br />SCALE: NTS <br />PV SOLAR SYSTEM DETAILS <br />MAIN SERVICE PANEL BUS SIZE: <br />MAIN SERVICE BREAKER SIZE: <br />BUILDING INFORMATION: <br />CONSTRUCTION TYPE: V-B <br />OCCUPANCY: R <br />ROOF: <br />SYSTEM SIZE: DC STC: KW <br />SYSTEM SIZE: AC CEC: KW <br />SOLAR MODULES: ( ) <br />ROOF PLAN <br />SINGLE LINE DIAGRAM <br />ATTACHMENT LAYOUT <br />SIGNAGE <br />ECB DATA SHEET <br />INVERTER DATA SHEET <br />1 <br />INDEX <br />2 <br />3.1 <br />4 <br />5 <br />6 <br />7 <br />8 <br />9 <br />10 <br />SITE PLAN <br />MODULE DATA SHEET <br />SATELLITE VIEW <br />SCALE: NTS <br />RACKING DATA SHEET <br />ATTACHMENT DATA SHEET <br />COVER PAGE0 <br />MAIN <br />3. ALL METALLIC EQUIPMENT SHALL BE GROUNDED <br />4. CONTRACTOR SHALL OBTAIN ELECTRICAL PERMITS PRIOR TO <br />INSTALLATION AND SHALL COORDINATE ALL INSPECTIONS, TESTING <br />COMMISSIONING AND ACCEPTANCE WITH THE CLIENT, <br />UTILITY CO. AND CITY INSPECTORS AS NEEDED. <br />5. THE ELECTRICAL CONTRACTOR SHALL VERIFY THE EXACT LOCATIONS OF <br />SERVICE POINTS AND SERVICE SIZES WITH THE SERVING UTILITY COMPANY <br />AND COMPLY WITH ALL UTILITY COMPANIES REQUIREMENTS. <br />6. DRAWINGS ARE DIAGRAMMATIC ONLY, ROUTING OF RACEWAYS SHALL <br />BE OPTION OF THE CONTRACTOR UNLESS OTHERWISE NOTED AND SHALL <br />BE COORDINATED WITH OTHER TRADES. <br />7. IF THE ROOF MATERIAL OR ROOF STRUCTURE NOT ADEQUATE FOR PV <br />INSTALLATION, CALL ENGINEER PRIOR TO INSTALL. THE CONTRACTOR IS <br />RESPONSIBLE TO VERIFY THAT THE ROOF IS CAPABLE OF WITHSTANDING <br />THE EXTRA WEIGHT. <br />8. IF THE DISTANCES FOR CABLE RUNS ARE DIFFERENT THAN SHOWN, THE <br />CONTRACTOR SHALL NOTIFY THE ELECTRICAL ENGINEER TO VALIDATE THE <br />WIRE SIZE. FINAL DRAWINGS WILL BE RED-LINED AND UPDATED AS <br />APPROPRIATE. <br />9. WHENEVER A DISCREPANCY IN QUALITY OF EQUIPMENT ARISES ON THE <br />DRAWING OR SPECIFICATIONS, THE CONTRACTOR SHALL BE RESPONSIBLE <br />FOR PROVIDING AND INSTALLING ALL MATERIAL AND SERVICES REQUIRED <br />BY THE STRICTEST CONDITIONS NOTED ON THE DRAWINGS OR IN THE <br />SPECIFICATIONS TO ENSURE COMPLETE COMPLIANCE AND LONGEVITY OF <br />THE OPERABLE SYSTEM REQUIRED BY THE ARCHITECT/ENGINEERS. <br />10. ALL BROCHURES, OPERATION MANUALS, CATALOGS, SHOP DRAWINGS, <br />ETC. SHALL BE HANDED OVER TO OWNER'S REPRESENTATIVE AT THE <br />COMPLETION OF WORK <br />PHOTOVOLTAIC NOTES: <br />1. ROOFTOP MOUNTED PHOTOVOLTAIC PANELS AND MODULES SHALL <br />BE TESTED, LISTED AND IDENTIFIED BY RECOGNIZED ELECTRICAL <br />TESTING LABORATORY <br />2. SOLAR SYSTEM SHALL NOT COVER ANY PLUMBING OR MECHANICAL <br />VENTS <br />3. MODULES AND SUPPORT STRUCTURES SHALL BE GROUNDED. <br />5. REMOVAL OF AN INTERACTIVE INVERTER OR OTHER EQUIPMENT SHALL <br />NOT DISCONNECT THE BONDING CONNECTION BETWEEN THE GROUNDING <br />ELECTRODE CONDUCTOR AND THE PHOTOVOLTAIC SOURCE AND/OR <br />OUTPUT CIRCUIT GROUNDED CONDUCTORS. <br />4. SOLAR INVERTER SHALL BE LISTED TO UL1741. <br />6. ALL PV MODULES AND ASSOCIATED EQUIPMENT AND WIRING <br />SHALL BE PROTECTED FROM PHYSICAL DAMAGE. <br />7. LIVE PARTS OF PV SOURCE CIRCUITS AND PV OUTPUT CIRCUITS <br />OVER 150V TO GROUND SHALL NOT BE <br />ACCESSIBLE TO OTHER THAN QUALIFIED PERSONS WHILE <br />ENERGIZED. <br />8. INVERTER IS EQUIPED WITH INTEGRATED GFDI, THUS PROVIDING <br />GROUND FAULT PROTECTION <br />9. ALL CONDUCTORS SHALL BE COPPER AND 90 DEG RATED <br />10. ALL ELECTRICAL EQUIPMENT SHALL BE LISTED BY A <br />RECOGNIZED ELECTRICAL TESTING LABORATORY. <br />11. A SINGLE CONDUCTOR SHALL BE PERMITTED TO BE USED TO <br />PERFORM THE MULTIPLE FUNCTIONS OF DC GROUNDING, AC <br />GROUNDING AND BONDING BETWEEN AC AND DC SYSTEMS. <br />12. NON-CURRENT CARRYING METAL PARTS OF EQUIPMENT SHALL <br />BE EFFECTIVELY BONDED TOGETHER. BOND BOTH ENDS OF <br />RACEWAYS. <br />GENERAL NOTES <br />1. ALL ELECTRICAL MATERIALS SHALL BE NEW AND LISTED BY RECOGNIZED <br />ELECTRICAL TESTING LABORATORY <br />CUSTOM MADE EQUIPMENT SHALL HAVE COMPLETE TEST DATA SUBMITTED <br />BY THE MANUFACTURER ATTESTING TO ITS SAFETY <br />2. OUTDOOR EQUIPMENT SHALL BE NEMA 3R RATED OR BETTER <br />FLAT TILE <br />03/21/2024DATE: <br />Project Name: <br />Alexandra Alejo <br />Property address: <br />2321 W St Anne Pl, <br />Santa Ana, CA 92704 <br />8.200 <br />5.800 <br />COVER PAGE0 <br />THE INSTALLATION OF SOLAR ARRAYS AND <br />PHOTOVOLTAIC POWER SYSTEMS SHALL COMPLY WITH <br />THE FOLLOWING CODES: <br />2020 NATIONAL ELECTRICAL CODE <br />2022 CALIFORNIA BUILDING CODE <br />2022 CALIFORNIA RESIDENTIAL CODE <br />2022 CALIFORNIA GREEN BUILDING STANDARD CODE <br />2022 CALIFORNIA PLUMBING CODE <br />2022 CALIFORNIA MECHANICAL CODE <br />2022 CALIFORNIA ELECTRICAL CODE <br />2022 CALIFORNIA FIRE CODE <br />2022 CALIFORNIA ENERGY CODE <br />2016 INTERNATIONAL PROPERTY MAINTENANCE CODE <br />ALL OTHER ORDINANCE ADOPTED BY THE LOCAL <br />GOVERNING AGENCIES <br />MOUNTING SYSTEM: <br />225A <br />200A <br />EXISTING <br />HANWHA 410 WATT <br />IRONRIDGE XR10 RAIL <br />ELECTRICAL INFORMATION: <br />11 <br />BATTERY: (2) Enphase IQ Battery 5P <br />NUMBER OF ESS UNITS: 2 <br />ESS UNIT SIZE (KWH): 3.84 KVA <br />ESS TOTAL SYSTEM SIZE: 2 UNITS AT 7.68 KVA <br />LACoFD NOTES <br />1. All work shall be in compliance with the most current Los <br />Angeles County FireCode. <br />2. When ESS is installed inside garage - any planned or <br />existing attached garage shall comply with all applicalbe coces <br />and standards, and with the manufacturer'sinstallation <br />manual(s) to which the equipment has been listed, including <br />requirements pertaining to fire protective features (eg gypsum <br />board, doors, andducts), and to alarm/detector devices. <br />SCOPE OF WORK <br />ESS System <br />Number and type ESS Units: New (2) Existing (0) <br />ESS units capacity (kwh/unit): 5.0 kWh/unit <br />Outdoor in Exterior Walls: (2) <br />Disconnects <br />Minimum number of disconnects required to turn off all power <br />feeding the home: (2) <br />(a) main panel - main breaker <br />(b) AC disconnect <br />MICROINVERTER: ( ) Enphase IQ8+ Microinverter <br />RSD DATA SHEET <br />12 <br />20 <br />20 <br />: 2 X 4 @ 24" O.C.RAFTER <br />BATTERY DATA SHEET <br />SIGNAGE3.2 <br />13 BATTERY MOUNTING DETAIL <br />14 EQUIPMENT ELEVATION <br />PEAK POWER SOLUTIONS <br />360 E 1ST STREET #947, <br />TUSTIN, CA 92780 <br />Phone: 714-258-3900 <br />License # 973253 C10 <br />-219 <br />The scope of the plans is for the installation of the solar photovoltaic <br />system only and the approval is subject to compliance with all <br />applicable city and state codes and regulations regarding construction. <br />The approval of the plans does not constitute any certification of the <br />accuracy, completeness, or building permit status of the existing <br />buildings and structures as shown. <br />Bldg# 101118766 <br />Elec# 20182453 <br /> <br />APPROVALS: <br />ELEC - MSmith <br />2321 W St Anne Pl - <br />201824535/23/2024