Laserfiche WebLink
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E <br />Project Name:Residence Addition Calculation Date/Time:2024-09-17T21:29:56-07:00 (Page 7 of 11) <br />Calculation Description:Title 24 Analysis Input File Name:20197.ribd22x <br />Registration Number:Registration Date/Time:    HERS Provider: <br />CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 <br />Schema Version: rev 20220901 <br />Report Generated: 2024-09-17   21:30:19 <br />OPAQUE SURFACE CONSTRUCTIONS <br />01 02 03 04 05 06 07 08 <br />Construction Name Surface Type Construction Type Framing Total Cavity <br />R-value <br />Interior / Exterior <br />Continuous <br />R-value <br />U-factor Assembly Layers <br />R-13 Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O. C.R-13 None / None 0.101 <br />Inside Finish: Gypsum Board <br />Cavity / Frame: R-13 / 2x4 <br />Exterior Finish: 3 Coat Stucco <br />Attic RoofExisting 1st <br />floor Attic Roofs Wood Framed <br />Ceiling 2x4 @ 24 in. O. C.R-0 None / 0 0.644 <br />Roofing: Light Roof (Asphalt Shingle) <br />Roof Deck: Wood <br />Siding/sheathing/decking <br />Cavity / Frame: no insul. / 2x4 <br />Attic Roof1st Floor <br />Addition Attic Roofs Wood Framed <br />Ceiling 2x4 @ 24 in. O. C.R-15 None / 0 0.07 <br />Roofing: Light Roof (Asphalt Shingle) <br />Roof Deck: Wood <br />Siding/sheathing/decking <br />Cavity / Frame: R-13.0 / 2x4 <br />Around Roof Joists: R-2.0 insul. <br />R-0 Roof Attic Ceilings (below <br />attic) <br />Wood Framed <br />Ceiling 2x4 @ 24 in. O. C.R-0 None / None 0.481 Cavity / Frame: no insul. / 2x4 <br />Inside Finish: Gypsum Board <br />R-30 Roof Attic Ceilings (below <br />attic) <br />Wood Framed <br />Ceiling 2x8 @ 16 in. O. C.R-30 None / None 0.033 <br />Over Ceiling Joists: R-11.2 insul. <br />Cavity / Frame: R-18.9 / 2x8 <br />Inside Finish: Gypsum Board <br />copy of R-30 Roof Attic Ceilings (below <br />attic) <br />Wood Framed <br />Ceiling 2x10 @ 16 in. O. C.R-30 None / None 0.034 <br />Over Ceiling Joists: R-6.0 insul. <br />Cavity / Frame: R-24.1 / 2x10 <br />Inside Finish: Gypsum Board <br />BUILDING ENVELOPE - HERS VERIFICATION <br />01 02 03 04 05 <br />Quality Insulation Installation (QII)High R-value Spray Foam Insulation Building Envelope Air Leakage CFM50 CFM50 <br />Not Required Not Required N/A n/a n/a <br />424-P010216755A-000-000-0000000-0000 09/18/2024 08:05 CHEERS <br />NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, <br />and cannot guarantee, the accuracy or completeness of the information contained in this document. <br />2314 S Warbler St <br />ADDITION12/12/2024