My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2314 S Warbler Street - Plan
PBA
>
Building
>
ProjectDox
>
W
>
Warbler St
>
2314 S Warbler St
>
2314 S Warbler Street - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/13/2025 4:11:22 AM
Creation date
6/5/2025 7:32:55 AM
Metadata
Fields
Template:
Plan
Permit Number
101120069
Full Address
2314 S Warbler St
Street Number
2314
Street Direction
S
Street Name
Warbler
Street Suffix
St
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
87
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
5%#.'Ä <br /><br />0(.1142.#0 <br /><br />'$'&411/ <br /><br />'$'&411/<br />'$'&411/ <br /><br />')#4#)' <br /><br />'.+8+0)4/ <br />$#6* <br /><br />0-+6%*'0 <br /><br />'%. <br /><br />0/$ <br /><br />0/#56'4 <br />$'&411/ <br /><br />'%. <br /><br />' <br /><br />0 <br />9+% <br /><br />0 <br />95 <br /><br />0 <br />2#0 <br />+5.#0& <br />5& <br />%1 <br />.')'0& <br />RECESSED LIGHT <br />ARC FAULT CIRCUIT INTERRUPTER <br />GROUND FAULT CIRCUIT INTERRUPTER <br />SWITCH <br />SMOKE DETECTOR <br />CARBON MONOXIDE ALARM <br />FAN/LIGHT <br />CEILING MOUNTED LIGHT <br />GFCI <br />AFCI <br />VACANCY SENSOR SWITCH <br />'.'%64+%#.)'0'4#.016'5 <br />1. ALL RECEPTACLES IN BATHROOMS, GARAGES, ACCESSORY BUILDINGS, OUTDOORS, KIT- <br />CHENS, LAUNDRY, UTILITY ROOMS, WET BAR SINKS ( WITHIN 6' OF THE EDGE OF THE SINK) <br />SHALL HAVE GROUND-FAULT CIRCUIT INTERRUPTER (GFCI) PROTECTION. [CEC 210.8]. <br />2. ALL BRANCH CIRCUITS SUPPLYING 120V 15-AMPERE AND 20-AMPERE OUTLETS IN FAMILY <br />ROOMS, DINING ROOMS, LIVING ROOMS, LIBRARIES, DENS, BEDROOMS, RECREATION ROOMS <br />CLOSETS, HALLWAYS AND SIMILAR ROOMS OR AREAS SHALL BE PROTECTED BY A LISTED ARC- <br />FAULT CIRCUIT INTERRUPTER (AFCI). [CEC 210.12(B)]. <br />3. NO POINT ALONG THE WALL SHALL BE FURTHER THAN 6 FEET FROM AN OUTLET MEASURED <br />HORIZONTALLY. [CEC 210.52(A)]. <br />4. COUNTERTOPS 12" OR WIDER IN KITCHENS, PANTRIES, BREAKFAST ROOMS, DINING ROOMS <br />AND SIMILAR AREAS SHALL HAVE RECEPTACLES INSTALLED SUCH THAT NO POINT ALONG THE <br />WALL IS MORE THAN 2' FROM A RECEPTACLE. RECEPTACLES OUTLETS SHALL BE LOCATED ABO- <br />VE BUT NOT MORE THAN 20" ABOVE THE COUNTERTOP AND SHALL BE READY ACCESSIBLE. <br />[CEC 210.52(C)]. <br />5. IN BATHROOMS, AT LEAST ONE RECEPTACLES SHALL BE INSTALLED WITHIN 3' OF THE OUT- <br />SIDE EDGE OF EACH BASIN. AT LEAST ONE 20-AMPERE BRANCH SHALL BE PROVIDED TO SU- <br />PLY BATHROOM RECPTACLE OUTLETS. THE CIRCUIT SHALL HAVE NO OTHER OUTLET. [CEC 210 <br />.11(C)(3)]. <br />6. AT LEAST ONE RECEPTACLE THAT IS SUPPLIED BY ST LEAST ONE ADDITIONAL 20-AMPERE <br />CIRCUIT SHALL BE INSTALLED FOR THE LAUNDRY. [CEC 210.52(F)] <br />7. IN CLOSETS, ALL LUMINAIRES SHALL BE SURFACES-MOUNTED INCADESCENT OR LED LUMI- <br />NAIRES WITH COMPLETELY ENCLOSED LIGHTS, AND SHALL BE INSTALLED SO THAT THE MINI- <br />MUM CLEARANCE BETWEEN THE LUMINAIRES AND THE NEAREST POINT OF STORAGE SPACE <br />WILL BE 12". [CEC 410.16]. <br />8. ELECTRICAL BOXES SHALL HAVE DRYWALL, PLASTER, OR PLASTERBOARD SURFACES FINI- <br />SHED SO THERE WILL BE NO GAPS OR OPEN SPACES GREATER THAN 1/8" AT THE EDGE OF <br />THE BOX PER CEC 314.21. IN WALLS OR CEILINGS BOXES SHALL BE INSTALLED SO THAT THE <br />FRONT ADGE OF THE BOX OR PLASTER RING SHALL NOT BE RECESSED MORE THAN 1/4" FROM <br />NON-COMBUSTIBLE FINISH SURFACE AND SHALL BE FLUSHED WITH A COMBUSTIBLE SURFACE <br />PER CEC 314.20 <br />9. PERMANENT LIGHTING SHALL COMPLY WITH THE APPLICABLE HIGH EFFICACY REQUIREMENTS <br />OF THE CALIFORNIA TITLE 24 PART 6 SECTION 150: <br /> - KITCHENS. AT LEAST HALF THE INSTALLED WATTAGE OF LUMINAIRES IN KITCHEN SHALL BE <br />HIGH EFFICACY AND THE ONES THAT ARE NOT MUST BE SWITCHED SEPARATELY. <br /> - LIGHTING IN BATHROOMS, GARAGES, LAUNDRY ROOMS AND UTILITY ROOMS. ALL LUMINAI- <br />RES SHALL EITHER BE HIGH EFFICACY OR SHALL BE CONTROLLED BY AN OCCUPANT SENSOR. <br /> - OTHERS ROOMS. ALL LUMINAIRES SHALL EITHER BE HIGH EFFICACY OR SHALL BE CONTRO- <br /> LLED BY AN OCCUPANT SENSOR OR DIMMER. CLOSETS THAT ARE LESS THAN 10 SQUARE <br />FEET ARE EXEMPT FROM THIS REQUIREMENTS. <br />- OUTDOOR LIGHTING. ALL LUMINAIRES MOUNTED TO THE BUILDING OR TO OTHER BUILDINGS <br />ON THE SAME LOT SHALL BE HIGH EFFICACY LUMINAIRES OR SHALL BE CONTROLLED BY A <br />PHOTOCONTROL/MOTION SENSOR COMBINATION. <br />11. NEW BOXES USED AT LUMINAIRE OR LANPHOLDER OUTLETS IN A CEILING SHALL BE RE- <br /> QUIRED TO SUPPORT A LUMINAIRE WEIGHING A MIN. OF 50 LBS. BOXES USED AT LUMINAIRE <br /> OUTLETS IN WALLS SHALL BE DESIGNED FOR THE PURPOSE AND SHALL BE MARKED ON THE <br /> INTERIOR INDICATING THE MAX. WEIGHT OF THE LUMINAIRE PERMITTED IF OTHER THAN 50 <br /> LBS. OUTLET BOXES OR SYSTEMS USED AS THE SOLE SUPPORT OF CEILING FANS SHALL BE <br /> LISTED AND MARKED BY THE MANUFACTURER AS SUITABLE FOR THIS PURPOSE. CEC 314.27 <br />12. DRIVEN GROUNDING ELECTRODES SHALL BE STAINLESS STEEL, A MIN. OF 5/8" DIAMETER, <br />AND A MIN. OF 8' DRIVEN INTO THE SOIL. THE GROUNDING ELECTRODE CONDUCTOR CONNEC- <br />TOR TO A DRIVEN ELECTRODES SHALL BE LISTED FOR THIS PURPOSE. [CEC 250.70]. <br />13. ANY FIXED APPLIANCE SUCH AS DISPOSAL, DISHWASHER, CLOTHES WASHER, DRYER, BU- <br />ILT-IN HEATERS, OR ANY OTHER FIXED APPLIANCE WITH 1/4 H.P. MOTOR OR LARGER, SHALL <br />BE ON A SEPARATE #12 AWG WIRE BRANCH CIRCUIT. EACH DWELLING UNIT SHALL HAVE INS- <br />TALLED THEREIN AN INDIVIDUAL DISPOSAL CIRCUIT SUPPLIED WITH MINIMUM #12 AWG WIRE <br />AND A 15 AMP INDICATING-TYPE SWITCH. <br />14. SMOKE ALARMS ARE REQUIRED OUTSIDE EACH SLEEPING AREA IN THE IMMEDIATE VICI- <br />NITY OF BEDROOMS, IN EACH ROOM USED FOR SLEEPING PURPOSES, IN EACH STORY INCLU- <br />DING BASEMENT IN CLOSE PROXIMITY TO STAIRWAYS. ALARMS SHALL BE INTERCONNECTED <br />SUCH THAT THE ACTIVATION OF ONE ALARM SHALL ACTIVATE ALL ALARMS. ALARMS SHALL BE <br />HARD-WIRED WITH BATTERY BACKUP. [CRC R314.3] <br />15. APPROVED CARBON MONOXIDE ALARMS ARE REQUIRED OUTSIDE EACH SLEEPING AREA <br />IN THE IMMEDIATE VICINITY OF BEDROOMS AND IN EACH STORY INCLUDING BASEMENT IN <br />CLOSE PROXIMITY TO STAIRWAYS. ALARMS SHALL BE INTERCONNECTED SUCH THAT THE AC- <br />TIVATION OF ONE ALARM SHALL ACTIVATE ALL ALARMS. ALARMS SHALL BE HARD-WIRED WITH <br />BATTERY BACKUP. [CRC R315.1] <br />16. APPOVED COMBINED SMOKE AND CARBON MONOXIDE ALARMS SHALL BE ACCEPTABLE. <br />17. A MIN. 1" ELECTRICAL CONDUIT SHALL BE INSTALLED FROM THE ELECTRICAL SERVICES PA- <br />NEL TO AN ACCESSIBLE LOCATION IN THE ATTIC FOR FUTURE ACCESS FOR A PHOTOVOLTAIC <br />SYSTEM. <br />BATHROOM EXHAUST FAN <br />SD <br />CO <br />#$$4'8+#6+105 <br />ARC FAULT CIRCUIT INTERRUPTER <br />GROUND FAULT CIRCUIT INTERRUPTER <br />SWITCH <br />SMOKE DETECTOR <br />CARBON MONOXIDE ALARM <br />GFCI <br />AFCI <br />VACANCY SENSOR SWITCH <br />S <br />WS <br />PAN <br />WORK STATION <br />PANTRY <br />WIC WALK IN CLOSET <br />MB MASTER BATHROOM <br />CL CLOSET <br />E EXISTING <br />+5.#0& <br />MIN. 50 CFM <br />EXHAUST <br />FAN <br />'0'4);%1&'4'37+4'/'065 <br />$7+.&+0)'0'4);'((+%+'0%;56#0&5 <br />C%'P%<br />U <br />D%'P%<br />V <br />E%'P%<br />W <br />F%'P%<br />X <br />'0'4);%1&'4'37+4'/'065 <br />$7+.&+0)'0'4);'((+%+'0%;56#0&5 <br />Ä) <br />(146*'-+6%*'0*11&2.'#5'2418+&'#4#0)'*11&+0%1/2.+#0%' <br />9+6*6*'6#$.'$'.19 <br />(+:674'55*#../''66*'(1..19+0)4'37+4'/'065 <br />(20) -CIRCUITS SHARING A GROUNDED CONDUCTOR (NEUTRAL) WITH TWO UNGROUNDED <br />(HOT) CONDUCTORS MUST USE A TWO-POLE CIRCUIT BREAKER OR AN IDENTIFIED <br />HANDLE TIE. (CEC 210.4(B)) GROUP NONCABLE CIRCUITS IN PANEL (CEC 210.4(D)) <br />(21) -THE RECEPTACLES OUTLETS THAT SERVE KITCHEN COUNTER TOPS, DINING ROOM, <br />BREAKFAST AREA, AND PANTRY, MUST HAVE A MIN OF 2 DEDICATED 20-AMP CIR- <br />CUITS. (CEC 210.52 (B)(1)). <br />(27) -PROVIDE 20-amp RECEPTACLE CIRCUIT FOR LAUNDRY AREA (CEC 210.11(C) (2)0. <br />(28) -PROVIDE 120V RECEPTACLE WITHIN 3 FEET OF WATER HEATER. (CAL ENERGY CODE <br />150.0 (N) 1 A.) <br />(25)- THE SPACING FOR GENERAL RECEPTACLE OUTLETS MUST BE LOCATED SO THAT <br />NO POINT ON ANY WALL, FIXED GLASS, OR CABINETS IS OVER 6 FEET FROM A RECEP- <br />TACLE. (CEC 210.52(A)(1)) <br />A. FANS SHALL BE ENERGY STAR COMPLIANT AND BE DUCTED TO TERMINATE OUTSIDE THE HOUSE <br />B. UNLESS FUNCTIONING AS A COMPONENT OF A WHOLE HOUSE VENTILATION SYSTEM, FANS <br /> MUST BE CONTROLLED BY A HUMIDITY CONTROL. <br /> I. HUMIDITY CONTROLS SHALL BE CAPABLE OF ADJUSTMENT BETWEEN A RELATIVELY HUMI- <br /> DITY RANGE OF LESS OR EQUAL TO 50% TO A MAXIMUM OF 80%. A HUMIDITY CONTROL <br /> MAY UTILIZE MANUAL OR AUTOMATIC MEANS OF ADJUSTMENT. <br /> II. A HUMIDITY CONTROL MAY BE A SEPARATE COMPONENT TO THE EXHAUST FAN AND IS <br /> NOT REQUIRED TO BE INTEGRAL (i.e.built-in). <br />':*#756(#0016' <br />(MINIMUM 50 CFM) <br />5& <br />5& <br />%1 <br />%1 <br />5& <br />5& <br />5& <br />5& <br />%1 <br />%1 <br />%1 <br />ALL RECEPTACLES FOR <br />KITCHEN COUNTER TOP <br />INCLUDING ISLAND TO BE <br />GFCI <br />05-E-1 <br />ELECTRICAL PLAN <br />SHEETSOF <br />CHECKED BY: <br />DATE: <br />DRAWN BY: <br />JOB NO: <br />SCALE: <br />SHEET NO.: <br />9-17-24 ENP1 <br />10-30-24 ENP2 <br />2314 S Warbler St <br />ADDITION12/12/2024
The URL can be used to link to this page
Your browser does not support the video tag.