SIMPLE ENGINEERING <br />Project:Warbler Street Residence Date:9/24/2024 <br />2314 S. Warbler Street <br />Santa Ana, CA 92704 <br />Description:New Kitchen & Master Bedroom Addition By:G. Hernandez <br />General: <br />Building Code: California Building Code, 2022 Edition <br />Risk Category: II <br />Wind Criteria: <br />Analysis Procedure: ASCE 7-16, Enclosed Simple Diaphragm Low Rise Building <br />Wind Speed (mph): 95 <br />Wind Exposure: C <br />Seismic Criteria: <br />Analysis Procedure: ASCE 7-16, Equivalent Lateral Force Procedure <br />Site Class: D - Default <br />Seismic Importance Factor, I E:1.0 <br />SS =1.299 S1 =0.465 <br />SDS =1.04 SD1 =0.569 <br />Seismic Design Category: D <br />Seismic Force Resisting System: Bearing Wall System, R= 6.5 <br />Light-frame (wood walls) sheathed w/ wood structural panels <br />R = 6.5 <br />Ωo =2.5 <br />Cd = 4.0 <br />Materials: <br />Masonry <br />ASTM C-90 Grade "N" <br />f'm =1500 psi <br />Mortar =1800 psi <br />Grout =2000 psi <br />Concrete <br />F'c=2500 psi for Slab-on-Grade & Footing <br />Reinforce Steel <br />ASTM A615 GR60 & GR40 <br />f'y =60 ksi <br />Foundation System: <br />Allowable Soil Bearing Pressure <br />F p =1500 psf <br />No Soils Report <br />Live Load: <br />Roof Live Load: 20 psf <br />Floor Live Load: 40 psf <br />Deck Live Load: 60 psf <br />Mapped Spectral Response <br />Accelerations: <br />Design Criteria <br />7 <br />2314 S Warbler St <br />ADDITION12/12/2024