Laserfiche WebLink
3 PETERS CANYON RD. STE 110 <br />IRVINE, CA 92606 <br />D <br />G <br />ESI <br />N <br />| <br />ARCHITECTURE <br />H E S T I A A T E L I E R <br />SHEET NUMBER: <br />SHEET TITLE: <br />SCALE: AS SHOWN <br />STORE #: <br />PROJECT #: <br />PR <br />O <br />J <br />E <br />C <br />T <br /> <br />N <br />A <br />M <br />E <br />: <br />PR <br />O <br />J <br />E <br />C <br />T <br /> <br />A <br />D <br />D <br />R <br />E <br />S <br />S <br />: <br />C 2020 STARBUCKS COFFEE COMPANY <br />R <br />ISSUE DATE: <br />2401 UTAH AVENUE SOUTH <br />SEATTLE, WASHINGTON 98134 <br />(206) 318-1575 <br />THESE DRAWINGS AND THE PROJECT MANUAL <br />ARE CONFIDENTIAL AND SHALL REMAIN THE <br />SOLE PROPERTY OF STARBUCKS <br />CORPORATION, WHICH IS THE OWNER OF THE <br />COPYRIGHT IN THIS WORK. THEY SHALL NOT <br />BE REPRODUCED (IN WHOLE OR IN PART), <br />SHARED WITH THIRD PARTIES OR USED IN ANY <br />MANNER ON OTHER PROJECTS OR <br />EXTENSIONS TO THIS PROJECT WITHOUT THE <br />PRIOR WRITTEN CONSENT OF STARBUCKS <br />CORPORATION. THESE DRAWINGS AND <br />SPECIFICATIONS ARE INTENDED TO EXPRESS <br />DESIGN INTENT FOR A PROTOTYPICAL <br />STARBUCKS STORE (WHICH IS SUBJECT TO <br />CHANGE AT ANYTIME) AND DO NOT REFLECT <br />ACTUAL SITE CONDITIONS. NEITHER PARTY <br />SHALL HAVE ANY OBLIGATION NOR LIABILITY TO <br />THE OTHER (EXCEPT STATED ABOVE) UNTIL A <br />WRITTEN AGREEMENT IS FULLY EXECUTED BY <br />BOTH PARTIES. <br />STARBUCKS R <br />DESIGN MANAGER: <br />PRODUCTION DESIGNER: <br />CHECKED BY: <br />STARBUCKS TEMPLATE VERSION: i2021.04.23 <br />76085-018 <br /><XX-XX-XXXX> <br />TU <br />S <br />T <br />I <br />N <br /> <br />& <br /> <br />S <br />A <br />N <br />T <br />A <br />CL <br />A <br />R <br />A <br />23 <br />0 <br />1 <br /> <br />N <br /> <br />T <br />U <br />S <br />T <br />I <br />N <br /> <br />A <br />V <br />E <br />, <br /> <br />S <br />A <br />N <br />T <br />A <br />AN <br />A <br />, <br /> <br />C <br />A <br />, <br /> <br />9 <br />2 <br />7 <br />0 <br />5 <br />51969 <br />CHARLIE CHANG <br />AMY YANG <br />MAGED GERGES <br />1S <br />T <br /> <br />P <br />E <br />R <br />M <br />I <br />T <br /> <br />S <br />U <br />B <br />M <br />I <br />T <br />T <br />A <br />L <br /> <br />S <br />E <br />T <br /> <br />- <br /> <br />0 <br />4 <br />/ <br />1 <br />6 <br />/ <br />2 <br />0 <br />2 <br />4 <br />Revision Schedule <br />Rev Date By Description <br />E001 <br />ELECTRICAL <br />NOTES <br />SECURITY SYSTEM NOTES <br />A.STARBUCKS CONTRACTS DIRECTLY WITH SECURITY VENDOR TO SUPPLY AND <br />INSTALL THE SECURITY SYSTEM. CONTRACTOR TO SCHEDULE INSTALLATION OF <br />SECURITY SYSTEM FOR FOUR (4) TIMES; <br />1.MEET TO PLAN SECURITY CABLE PULL WITH SECURITY CABLE INSTALLER <br />PRIOR TO DRYWALL INSTALLATION. <br />2.SECURITY CABLE INSTALLER PULLS SECURITY CABLES, MOUNTS PANEL, <br />KEYPAD AND SENSORS. <br />3.SECURITY EQUIPMENT INSTALL OF CAMERA, NVR AND MONITOR. <br />4.SECURITY MONITORING COMPANY TO BRING SYSTEM ONLINE AND TRAIN <br />PARTNERS AFTER POS INSTALL <br />B.SECURITY VENDOR REQUIRES A MINIMUM TWO (2) WEEKS LEAD TIME FOR EACH <br />INSTALLATION. SECURITY VENDOR WILL COORDINATE REGIONAL INSTALLERS. ALL <br />ADDITIONAL EXPENSES INCURRED DUE TO THE CONTRACTOR'S FAILURE TO <br />SCHEDULE ACCORDINGLY WILL BE THE RESPONSIBILITY OF THE CONTRACTOR. <br />TELEPHONE SYSTEM NOTES <br />A.IF ADDITIONAL TELEPHONE LINES ARE REQUIRED BEYOND THE STANDARD SINGLE <br />LINE (SUCH AS FOR A FIRE ALARM) THE GENERAL CONTRACTOR SHALL CONTACT <br />STARBUCKS PRIOR TO BEGINNING CONSTRUCTION TO ORDER THE ADDITIONAL <br />TELEPHONE LINE(S). REPORT ANY TELEPHONE INSTALLATION ISSUES IMMEDIATELY <br />TO STARBUCKS. <br />B.CONFIRM PRIOR TO BEGINNING CONSTRUCTION THAT THERE ARE EXISTING, <br />WORKING TEL FACILITIES TO THE BUILDING OR THAT LANDLORD HAS FURNISHED <br />AND INSTALLED ONE (1) 2" (51MM) MIN. (ENTRANCE) CONDUIT INCLUDING PULL <br />STRING FROM TELCO STREET FEED LINE TO THE BUILDING AS IDENTIFIED BY THE <br />PHONE COMPANY. NOTIFY STARBUCKS CONSTRUCTION MANAGER IMMEDIATELY IF <br />FACILITIES OR CONDUIT AND PULL STRING ARE NOT INSTALLED. <br />C.GENERAL CONTRACTOR IS TO ENSURE THAT THERE IS A 2" (51MM) MIN. CONDUIT <br />WITH PULL STRING FROM THE DATA RACK TO THE DEMARC (TELCO TO CUSTOMER <br />HAND OFF EQUIPMENT) WHEN THE DEMARC IS MORE THAN 10' FROM THE DATA <br />RACK. DISTANCES LESS THAN 10' WILL NOT REQUIRE CONDUIT. <br />D.ALL TELEPHONE/NETWORK CABLING IS THE SCOPE OF WORK OF THE TELEPHONE/ <br />NETWORK CABLING VENDOR. <br />POS/ DATA LINE NOTES <br />A.STARBUCKS CONTRACTS DIRECTLY WITH THE DATA CABLING VENDOR TO SUPPLY <br />AND INSTALL CATEGORY 5e (CAT5e) LAN CABLE AND CONNECTORS FOR THE POINT <br />OF SALE (POS) SYSTEMS. CONTRACTOR TO SCHEDULE INSTALLATION OF DATA <br />CABLING WITH DATA CABLING VENDOR. DATA CABLING VENDOR REQUIRES A LEAD <br />TIME FOR INSTALLATION. DATA CABLING VENDOR WILL COORDINATE REGIONAL <br />INSTALLERS. <br />B.AT THE START OF CONSTRUCTION, STARBUCKS CONSTRUCTION MANAGER <br />SCHEDULES DELIVER OF CASH REGISTER/MANAGER'S WORKSTATION EQUIPMENT <br />AND INSTALLATION BY A POS INSTALL TECHNICIAN FOR ONE (1) MONTH PRIOR TO <br />STORE OPEN. CONTRACTOR TO VERIFY DELIVERY SCHEDULE TWO (2) WEEKS PRIOR <br />TO DELIVERY AND INSTALLATION DATE. EQUIPMENT IS SHIPPED DIRECTLY TO THE <br />STORE. CONTRACTOR TO ACCEPT POS EQUIPMENT DELIVERY. DO NOT REFUSE <br />DELIVERY. <br />C.DATA CABLING TECHNICIAN TO PROVIDE ALL CAT5e LAN CABLING AND <br />CONNECTORS FROM ALL DESIGNED AND FUTURE CASH REGISTER LOCATIONS, <br />MANAGER'S WORKSTATION, ALL OTHER NETWORKED EQUIPMENT (CUP LABELERS, <br />CLOVER, BUMP BAR, ETC...) AND WIRELESS ACCESS POINT TO THE DATA RACK <br />AREA. CONTRACTOR IS TO HAVE CONDUIT WITH PULL STRING IN PLACE FOR ALL <br />CABLE RUNS PRIOR TO CABLE INSTALL DATE. <br />D.STARBUCKS NEW STORE GROUP IS RESPONSIBLE FOR COORDINATING STARBUCKS <br />POS SYSTEMS DELIVERY AND INSTALLATION WITH THE POS VENDOR. THIS GROUP <br />MAY BE CONTACTED AT: NEWSTORES@STARBUCKS.COM. <br />COMMUNICATION SYSTEM NOTES <br />A.CONFIRM PRIOR TO BEGINNING CONSTRUCTION THAT THE LANDLORD HAS <br />FURNISHED AND INSTALLED ONE (1) ADDITIONAL 2" (51MM) (ENTRANCE) CONDUIT <br />INCLUDING PULL STRING (FOR A TOTAL OF TWO (2)) FROM THE STREET FEED TO <br />THE BUILDING AS IDENTIFIED BY THE INTERNET SERVICE PROVIDER. <br />FIRE ALARM SYSTEM NOTES <br />A.IF STARBUCKS IS REQUIRED TO PROVIDE A FIRE ALARM AND/OR FIRE ALARM <br />MONITORING AND/OR PHONE LINES FOR A FIRE ALARM, AS SPECIFIED IN THE LEASE <br />AGREEMENT, THE CONTRACTOR IS TO NOTIFY GNOC IMMEDIATELY THAT FIRE <br />ALARM LINES ARE NEEDED. STARBUCKS PREFERRED FIRE ALARM SERVICE <br />PROVIDER, STANLEY, IS TO BE CONTACTED BY THE CONSTRUCTION MANAGER TO <br />INSTALL FIRE ALARM PANEL AND/OR MONITORING SERVICE AS REQUIRED. <br />WIRELESS NETWORK NOTES <br />A.CABLING FOR INTERNET SERVICE SHALL BE FURNISHED AND INSTALLED BY THE <br />VENDOR FOR FIBER OR BROADBAND CONNECTIONS. T1 AND ETHERNET EXTENSION <br />CABLING IS PROVIDED BY THE STARBUCKS (TELEPHONE/ NETWORK) CABLING <br />VENDOR. COORDINATE WITH STARBUCKS. <br />MUSIC SYSTEM NOTES <br />A.PROVIDE AND INSTALL A COMPLETE WIRING SYSTEM FOR ALL SPEAKERS. <br />CONNECT ALL SPEAKERS TO THE OWNER PROVIDED MUSIC SYSTEM. <br />MOUNT OWNER FURNISHED SPEAKERS WHERE SHOWN ON INTERIOR <br />REFLECTED CEILING PLAN AND IN COORDINATION WITH ALL PLANS AND <br />DETAILS. FOLLOW MANUFACTURER'S INSTALLATION REQUIREMENTS. <br />CONTROLS AND OPERATION <br />A.COORDINATE INSTALLATION OF LIGHTING CONTROL PANEL (IF APPLICABLE) <br />AND ENERGY MANAGEMENT SYSTEM (EMS) WITH ENERGY MANAGEMENT <br />SYSTEM VENDOR. <br />B.FURNISH AND INSTALL RACEWAYS WITH PULLSTRINGS AND JUNCTION BOXES <br />TO SUPPORT VENDOR’S WORK. <br />C.COORDINATE WITH VENDOR AND PLANS FOR DEVICE LOCATIONS. <br />GENERAL ELECTRICAL NOTES <br />A.THE ELECTRICAL CONTRACTOR SHALL COORDINATE ELECTRICAL WORK AND <br />SPECIFICATIONS WITH OTHER TRADES. THE ARCHITECTURAL DRAWINGS AND <br />SPECIFICATIONS SHALL TAKE PRECEDENCE OVER ALL OTHER DRAWINGS. DO NOT <br />SCALE DISTANCES OFF THE ELECTRICAL DRAWINGS; USE ACTUAL BUILDING <br />DIMENSIONS. OVERALL CASEWORK COMPONENT DIMENSIONING ON ELECTRICAL <br />DETAILS ARE SHOWN FOR REFERENCE AND COORDINATION ONLY. SEE <br />SPECIFICATION SHEETS FOR ELECTRICAL SPECIFICATIONS. <br />B.ALL ELECTRICAL SYSTEMS SHALL BE TESTED FOR PROPER OPERATION. BALANCE <br />ALL BRANCH CIRCUIT LOADS BETWEEN THE PHASES OF THE SYSTEM WITHIN 10% <br />OF THE HIGHEST PHASE LOAD IN EACH PANEL BOARD. <br />C.THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR DE-ENERGIZING <br />CIRCUITS IN DEMOLITION AREAS TO INSURE A SAFE CONDITION. ELECTRICAL <br />DEVICES AND ASSOCIATED WIRING LOCATED WITHIN THE DEMOLITION AREA THAT <br />WILL NO LONGER BE USED SHALL BE REMOVED AND PROPERLY DISPOSED OF AT <br />CONTRACTORS EXPENSE UNLESS OTHERWISE NOTED. <br />D.THE ELECTRICAL CONTRACTOR SHALL SCHEDULE ALL ELECTRICAL SYSTEM <br />OUTAGES WITH THE GENERAL CONTRACTOR AND LANDLORD AT LEAST 24 HOURS IN <br />ADVANCE. UNLESS APPROVED OTHERWISE ALL OUTAGES SHALL OCCUR BETWEEN <br />11:00PM AND 5:00AM. <br />E.ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL ALL NECESSARY CONDUIT <br />AND J-BOXES TO SUPPORT A COMPLETE SECURITY, PHONE, POS AND DATA <br />SYSTEMS. SEE MANAGER WORKSTATION AND BAR POINT OF SALE (POS) <br />POWER/TELECOM/SECURITY DIAGRAM. COORDINATE ALL DEVICE LOCATIONS AND <br />MOUNTING HEIGHTS WITH SECURITY VENDOR PRIOR TO ROUGH-IN. PROVIDE <br />END-TO-END PULL STRINGS IN ALL CONDUITS. LABEL EACH END OF THE PULL <br />STRING WITH CONDUIT SYSTEM ("SECURITY") AND DESTINATION ("CAFÉ", "FRONT <br />BAR", ETC.). PROVIDE INSULATED BUSHINGS ON ALL STUBBED-UP AND EXPOSED <br />CONDUIT ENDS. <br />F.ELECTRICAL CONTRACTOR SHALL COORDINATE WITH THE GENERAL CONTRACTOR <br />TO PATCH AND REPAIR ALL EXISTING WALLS, FLOORS, CEILINGS OR OTHER <br />SURFACES IDENTIFIED TO REMAIN THAT MAY BECOME DAMAGED DURING THE <br />COURSE OF WORK. <br />G.EXPOSED/SURFACE MOUNTED CONDUITS SHALL ONLY BE ALLOWED WHERE <br />NECESSARY IN EXPOSED CEILING AREAS. IF CONDUITS NEED TO BE SURFACE <br />MOUNTED TO WALLS, COORDINATE WITH STARBUCKS CONSTRUCTION MANAGER <br />FOR APPROVAL. <br />H.VERIFY LOCATION OF ALL OUTLETS AND SWITCHES WITH ARCHITECTURAL <br />DRAWINGS, INTERIOR DETAILS, FINISH SCHEDULES, GENERAL CONTRACTOR, <br />EQUIPMENT VENDORS, STARBUCKS AND EXISTING SITE CONDITIONS. VERIFY FINAL <br />DOOR HINGE LOCATION PRIOR TO SWITCH INSTALLATION AND ADJUST SWITCH <br />LOCATION IF NEEDED. DO NOT MOUNT RECEPTACLES/SWITCHES IN LOCATIONS <br />THAT WOULD CONFLICT WITH MIRRORS, SEAMS OF WALLS, WAINSCOTS, TILE <br />TRANSITIONS, ETC. <br />GENERAL NOTES <br />SCOPE <br />THE INTENT OF THE SPECIFICATION AND THE DRAWINGS IS TO PROVIDE A <br />COMPLETE AND FULLY OPERATIONAL ELECTRICAL SYSTEM. THE ELECTRICAL <br />CONTRACTOR SHALL FURNISH AND INSTALL ALL LABOR, MATERIAL, AND <br />EQUIPMENT NECESSARY TO COMPLETE THE ELECTRICAL WORK. <br />SITE EXAMINATION <br />THE ELECTRICAL CONTRACTOR SHALL THOROUGHLY EXAMINE ALL AREAS <br />WHERE EQUIPMENT, CONDUIT, AND WIRING WILL BE INSTALLED AND WILL <br />REPORT ANY CONDITION THAT, IN HIS OPINION, PREVENTS THE PROPER <br />INSTALLATION OF THE ELECTRICAL WORK. <br />STANDARDS <br />EQUIPMENT AND MATERIALS SHALL CONFORM WITH APPROPRIATE <br />PROVISIONS OF CSA, ULC, NEC, ASTM, UL, ETL, NEMA, ANSI, AS APPLICABLE <br />TO EACH INDIVIDUAL UNIT OR ASSEMBLY. <br />CODES <br />ALL WORK SHALL BE PERFORMED IN STRICT ACCORDANCE WITH ALL <br />APPLICABLE PROVINCIAL AND LOCAL CODES AND ORDINANCES. IN CASE OF <br />CONFLICT BETWEEN THE DRAWINGS AND SPECIFICATIONS AND THE CODES, <br />THE HIGHEST STANDARD SHALL APPLY. ELECTRICAL CONTRACTOR SHALL <br />SATISFY CODE REQUIREMENTS AS A MINIMUM STANDARD WITHOUT ANY <br />EXTRA COST TO STARBUCKS. <br />PERMITS AND FEES <br />THE ELECTRICAL CONTRACTOR SHALL PROCURE AND PAY FOR ALL PERMITS, <br />FEES, AND INSPECTIONS NECESSARY TO COMPLETE THE ELECTRICAL WORK. <br />WARRANTY <br />THE ELECTRICAL CONTRACTOR SHALL UNCONDITIONALLY WARRANT ALL <br />WORK TO BE FREE OF DEFECTS IN MATERIAL AND WORKMANSHIP FOR A <br />PERIOD OF ONE (1) YEAR FROM THE DATE OF FINAL ACCEPTANCE BY <br />STARBUCKS AND WILL REPAIR OR REPLACE ANY DEFECTIVE WORK <br />PROMPTLY AND WITHOUT CHARGE AND RESTORE ANY OTHER EXISTING <br />WORK DAMAGED IN THE COURSE OF REPAIRING DEFECTIVE MATERIALS AND <br />WORKMANSHIP. <br />STANDARD ABBREVIATIONS <br />AFF <br />AHJ <br />APPROX <br />ABOVE FINISHED FLOOR <br />AUTHORITIES HAVING JURISDICTION <br />APPROXIMATE <br />BLDG BUILDING <br />CKT <br />CLG <br />CM <br />CONST <br />CW <br />CXA <br />CIRCUIT <br />CEILING <br />STARBUCKS CONSTRUCTION MANAGER <br />CONSTRUCTION <br />COLD WATER <br />COMMISSIONING AGENT <br />DEG <br />DL <br />DM <br />DN <br />DTL <br />DWG(S) <br />DEGREES <br />LIGHTS WITHIN DAYLIGHT ZONE <br />STARBUCKS DESIGN MANAGER <br />DOWN <br />DETAIL <br />DRAWING(S) <br />EA <br />EC <br />ECP <br />EG <br />ELEC <br />EM <br />EMS <br />EXIST <br />EXT <br />EACH <br />ELECTRICAL CONTRACTOR <br />EQUIPMENT CONTROL PAC <br />EXHAUST GRILLE <br />ELECTRICAL <br />EMERGENCY <br />ENERGY MANAGEMENT SYSTEM <br />EXISTING <br />EXTERIOR <br />F&I <br />FLR <br />FT <br />FURNISH & INSTALL <br />FLOOR <br />FOOT/FEET <br />GC <br />GFCI <br />GND <br />GENERAL CONTRACTOR <br />GROUND FAULT CIRCUIT INTERRUPTER <br />GROUND <br />HR <br />HVAC <br />HW <br />HOUR <br />HEATING, VENTILATION, AIR CONDITIONING <br />HOT WATER <br />LCP <br />LL <br />LS <br />LV <br />LIGHTING CONTROL PANEL <br />LANDLORD <br />LIGHT SENSOR PHOTOCELL <br />LOW VOLTAGE <br />MAX <br />MC <br />MDP <br />MECH <br />MEP <br />MFG <br />MIN <br />MAXIMUM <br />MECHANICAL CONTRACTOR <br />MAIN DISTRIBUTION PANEL <br />MECHANICAL <br />MECHANICAL, ELECTRICAL, AND PLUMBING <br />MANUFACTURER <br />MINIMUM <br />NL <br />NTS <br />NIGHTLIGHT <br />NOT TO SCALE <br />OCP OVERCURRENT PROTECTION <br />REF <br />REQ(’D) <br />REV <br />REFERENCE <br />REQUIRE(D) <br />REVISION <br />SF <br />SHT <br />SPECS <br />SST <br />SQUARE FEET <br />SHEET <br />SPECIFICATION(S) <br />STAINLESS STEEL <br />TEL <br />TEMP <br />TYP <br />TELEPHONE <br />TEMPORARY <br />TYPICAL <br />UNO UNLESS NOTED OTHERWISE <br />WH <br />WP <br />WATER HEATER <br />WEATHER PROOF <br />ELECTRICAL SYMBOL LEGEND <br />SYMBOL DESCRIPTION <br />POWER <br />DUPLEX RECEPTACLE, WALL MOUNTED <br />DUPLEX RECEPTACLE, WALL MOUNTED, SPLIT-WIRED OCCUPANCY SENSOR <br />CONTROLLED/SWITCHED <br />DUPLEX RECEPTACLE, WALL MOUNTED, ISOLATED GROUND <br />DUPLEX RECEPTACLE, WALL MOUNTED ABOVE COUNTER <br />DUPLEX GFCI RECEPTACLE, WALL MOUNTED <br />DUPLEX GFCI RECEPTACLE, WALL MOUNTED ABOVE COUNTER <br />DUPLEX RECEPTACLE, WALL MOUNTED WITH TWO 5V USB CHARGING PORTS <br />DOUBLE DUPLEX RECEPTACLE, WALL MOUNTED <br />DOUBLE DUPLEX GFCI RECEPTACLE, WALL MOUNTED <br />DUPLEX RECEPTACLE, FLUSH IN CEILING <br />SPECIAL OUTLET: 20A, 250V, 2P, 3-WIRE NEMA 6-20R <br />SPECIAL OUTLET: 30A, 125V, 1P, 3-WIRE NEMA 5-30R <br />SPECIAL OUTLET: 30A, 250V, 2P, 3-WIRE NEMA 6-30R <br />SPECIAL OUTLET: 50A, 250V, 2P, 3-WIRE NEMA 6-50R <br />SPECIAL OUTLET: 50A, 250V, 3P, 4-WIRE NEMA 14-50R <br />SPECIAL OUTLET: 50A, 250V, 3-PHASE, 4-WIRE NEMA 15-50R <br />JUNCTION BOX <br />JUNCTION BOX - WALL MOUNTED <br />JUNCTION BOX MOUNTED IN ACCESSIBLE CEILING SPACE. MOUNT FLUSH IN FLOOR WHEN <br />INDICATED IN A FLOOR BOX SYMBOL. <br />NON-FUSED DISCONNECT SWITCH <br />FUSED DISCONNECT SWITCH <br />MOTOR. NUMBER INDICATES HORSEPOWER RATING FOR 1HP AND LARGER <br />MOTOR. "F" INDICATES FRACTIONAL HORSEPOWER <br />TRACK CURRENT LIMITER. "#" DENOTES AMPS RATING. <br />POWER SUPPLY/DRIVER, CLASS 2 FOR LED <br />FLOOR BOX SPECIFICATIONS <br />SINGLE SERVICE IN FLOOR BOX. PROVIDE DEVICES PER PLAN. <br />WIREMOLD RFB2-OG/FPCTC WHEN SHOWN IN ON-GRADE <br />WIRE MOLD 6ATCP, 6ATP, OR 6ATCPAV AS REQUIRED WHEN SHOWN IN ABOVE GRADE. <br />TWO SERVICE IN FLOOR BOX. PROVIDE DEVICES PER PLAN. <br />WIREMOLD RFB2-OG/FPCTC WHEN SHOWN IN ON-GRADE <br />WIRE MOLD 6ATCP, 6ATP, OR 6ATCPAV AS REQUIRED WHEN SHOWN IN ABOVE GRADE. <br />SIGNAL <br />TELEPHONE OUTLET <br />DATA OUTLET <br />COMBINATION TELEPHONE/COMPUTER OUTLET <br />LIGHTING CONTROL SYMBOLS <br />SINGLE POLE SWITCH, 20A, 120/277V or CAT5e WIRED WALL SWITCH TO BE USED WITH <br />NON-DIMMING POWER/RELAY PACK <br />LOW VOLTAGE (0-10V) WALL MOUNTED SWITCH FOR MANUAL ON/OFF AND DIMMING <br />(STEPPED/CONTINUOUS) CONTROL OF LIGHTING. "a" INDICATES ZONE WHERE SHOWN ON <br />DRAWINGS. <br />OCCUPANCY SENSOR - WALL MOUNTED. "a" INDICATES CONTROLLED ZONE. SEE CONTROL <br />CONFIGURATIONS FOR MORE INFORMATION. <br />OCCUPANCY SENSOR w/ DIMMER - WALL MOUNTED. "a" INDICATES CONTROLLED ZONE. <br />SEE CONTROL CONFIGURATIONS FOR MORE INFORMATION. <br />1-WAY/2-WAY DIRECTIONAL CEILING MOUNTED, NON-NETWORKED/ INTERCONNECTED/ <br />NETWORKED, SYSTEM-BASED OCCUPANCY SENSOR. QUANTITY OF ADJACENT LOWER CASE <br />LETTERS INDICATES QUANTITY OF RELAYS/DIMMING CIRCUITS REQUIRED - SEE CONTROL <br />CONFIGURATIONS BELOW FOR MORE INFORMATION. EXACT CONTROL FUNCTION IS DETERMINED <br />BY THE BALLAST/FIXTURE TYPE. <br />AUTOMATIC CONTINUOUS DIMMING DAYLIGHTING CONTROLLER USED TO DIM LIGHTS WHEN <br />SUFFICIENT NATURAL LIGHT IS PRESENT. NUMBER IN PARENTHESIS INDICATES THE AVERAGE <br />WORKPLANE "TARGET ILLUMINATION" SYMBOL VALUE. ADJACENT LOWER CASE LETTER(S) <br />INDICATES SWITCH LEG(S) CONTROLLED. ADJACENT "+, ++ AND *" INDICATES PORTION OF SWITCH <br />LEG CONTROLLED BY SENSOR WHERE "+" INDICATES PRIMARY SIDELIT DAYLIT ZONE, "++" <br />INDICATES SECONDARY SIDELIT DAYLIT ZONE, AND "*" INDICATES SKYLIT DAYLIT ZONE. <br />CONTROL CONFIGURATIONS <br />y "y" INDICATES THAT SWITCH LEG "y" TO BE CONFIGURED IN A "AUTO ON 100% / AUTO OFF" AND BE <br />CONTROLLED (CONTINUOUSLY DIMMED) BY THE ASSOCIATED CEILING SENSOR REMOTE SWITCH <br />ON THE WALL. <br />y,(y)"y,(y)" INDICATES THAT SWITCH LEG "y" TO BE CONFIGURED IN A "AUTO ON 50% / MANUAL ON 100% <br />/ AUTO OFF" AND BE CONTROLLED (CONTINUOUSLY DIMMED) BY THE ASSOCIATED DISTRIBUTED <br />LIGHTING CONTROLS. <br />(y)"(y)" INDICATES THAT SWITCH LEG "y" IS TO BE CONFIGURED IN A "MANUAL ON / AUTO OFF" <br />(VACANCY SENSOR) AND BE CONTROLLED BY THE ASSOCIATED DISTRIBUTED LIGHTING <br />CONTROLS. <br />J <br />J <br />J <br />30/1 <br />30/3RF <br />5 <br />F <br />y,(y) <br />(40) <br />y+,y++ <br />APPLICABLE CODES <br />2022 CALIFORNIA BUILDING CODE (CBC) <br />2022 CALIFORNIA ELECTRICAL CODE <br />2022 CALIFORNIA MECHANICAL CODE (CMC) <br />2022 CALIFORNIA PLUMBING CODE (CPC) <br />2022 CALIFORNIA ENERGY CODE <br />2022 CALIFORNIA FIRE CODE <br />2022 NATIONAL FIRE ALARM AND SIGNALING CODE <br />2022 CALIFORNIA GREEN BUILDING STANDARDS CODE (CGBSC) <br />ALLOWED SPECIFICATIONS DEVIATIONS <br />THE FOLLOWING ITEM(S) ARE ALLOWED DEVIATIONS FROM THE DRAWINGS AND <br />SPECIFICATIONS. THESE DEVIATIONS ARE AT THE DIRECTION OF THE OWNER. <br />NONE <br />SCOPE OF WORK <br />ELECTRICAL DESIGN FOR RETAIL AND BACKBAR RENOVATION. <br />DEFERRED APPROVAL <br />A.FIRE ALARM SYSTEM SHALL BE UNDER SEPARATE PERMIT. SEPARATE PLANS <br />SHALL BE SUBMITTED FOR APPROVAL BY A FIRE ALARM ENGINEER AND ALL <br />PERMITS, INSPECTIONS AND APPROVALS SHALL BE OBTAINED FROM THE FIRE <br />DEPARTMENT HAVING JURISDICTION. <br />B.VIA SEPARATE SUBMITTAL BY SIGN CONTRACTOR, OBTAIN APPROVALS AND <br />PERMITS FOR ALL SIGNS INCLUDING SIGN LIGHTING CERTIFICATE OF <br />COMPLIANCE. <br />C.VIA SEPARATE SUBMITTAL, OBTAIN APPROVALS AND PERMITS FOR ALL <br />ELECTRICAL SUBSYSTEMS WITH POWER SUPPLIES OF MORE THAN 50 VA AND/OR <br />250 VOLTS [E.G. SECURITY, TELCO/DATA, P.A, AUDIOVISUAL, HVAC CONTROLS, <br />ETC.] <br />DEMOLITION AND REWIRING SYMBOLS <br />"E"ADJACENT TO LIGHT FIXTURE OR OUTLET SYMBOL OR IN CONDUIT RUN <br />INDICATES EXISTING TO REMAIN. EXISTING CONDUCTORS TO REMAIN <br />UNLESS OTHERWISE NOTED ON DRAWINGS. <br />"EX"IN CONDUIT RUN INDICATES EXISTING CONDUIT RUN TO BE REWIRED. <br />PULL OUT EXISTING WIRES AND INSTALL NEW WIRES, QUANTITY AS <br />INDICATED BY HASH MARKS. REFER TO PLANS FOR WIRING <br />REQUIREMENTS. PROVIDE OTHER SYSTEM CONDUCTORS PER <br />SPECIFICATIONS. <br />"EA"ADJACENT TO LIGHT FIXTURE OR OUTLET SYMBOL OR IN CONDUIT RUN <br />INDICATES EXISTING TO BE ABANDONED. REMOVE DEVICE AND INSTALL <br />BLANK PLATE AND PULL WIRES FROM CONDUIT AS REQUIRED. <br />"R"ADJACENT TO LIGHT FIXTURE OR OUTLET SYMBOL OR IN CONDUIT RUN <br />INDICATES EXISTING TO BE REMOVED. EXISTING CONDUIT AND WIRE TO <br />BE COMPLETELY DISCONNECTED AND REMOVED BACK TO LAST <br />REMAINING OUTLET OR DEVICE. <br />"RR"ADJACENT TO ELECTRICAL OUTLET, EQUIPMENT, ETC. INDICATES <br />EXISTING TO BE REMOVED AND REPLACE WITH NEW. <br />"RL"ADJACENT TO ELECTRICAL OUTLET, EQUIPMENT, ETC. INDICATES <br />EXISTING TO BE REMOVED AND RELOCATED. <br />"R-X-E" <br />"E-X-R" <br />“X” INDICATES APPROXIMATE POINT OF INTERCEPTION OF EXISTING <br />CONDUIT RUN. CONDUIT TO BE REMOVED AT “R” SIDE OF “X”. REMOVE <br />ALL CONDUCTORS PRIOR TO CUTTING CONDUIT. EXACT LOCATION OF ALL <br />CONDUITS SHALL BE FIELD VERIFIED. EXTEND CONDUIT AND WIRES TO <br />MATCH EXISTING OR AS INDICATED ON PLANS. PROVIDE PULL BOX SIZE <br />PER CEC REQUIREMENT. <br />STAMP DATE: 04/13/2024 <br />PR <br />O <br />J <br />E <br />C <br />T <br /> <br />N <br />A <br />M <br />E <br />: <br />PR <br />O <br />J <br />E <br />C <br />T <br /> <br />A <br />D <br />D <br />R <br />E <br />S <br />S <br />: <br />TU <br />S <br />T <br />I <br />N <br /> <br />& <br /> <br />S <br />A <br />N <br />T <br />A <br />CL <br />A <br />R <br />A <br />23 <br />0 <br />1 <br /> <br />N <br /> <br />T <br />U <br />S <br />T <br />I <br />N <br /> <br />A <br />V <br />E <br />, <br /> <br />S <br />U <br />I <br />T <br />E <br /> <br />A <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br />, <br /> <br />9 <br />2 <br />7 <br />0 <br />5 <br />STORE #: <br />PROJECT #: <br />ISSUE DATE: <br />DESIGN MANAGER: <br />PRODUCTION DESIGNER: <br />CHECKED BY: <br />76085-018 <br />04-15-2024 <br />51969 <br />CHARLIE CHANG <br />SEPIDEH SHARIFI <br />MAGED GERGES <br />2301 N Tustin Ave <br />#A8/22/2024