Laserfiche WebLink
ADJACENT <br />TENANT <br />(NIC) <br />L 20662 <br />L 21772 <br />L 21772 <br />L 20661 <br />L 21776 <br />L 19409 <br />L 21779 <br />L 21774 <br />L 20748 <br />L 21774 <br />L 20748 <br />L 21774 <br />L 21783 <br />L 21772 <br />BACKBAR <br />RETAIL <br />SEATING <br />AREA <br />WORKROOM <br />PARTNER / <br />MANAGER <br />AREA <br />UNISEX <br />PARTNER <br />RESTROOM <br />UNISEX <br />CUSTOMER <br />RESTROOM <br />(N) 2X4 ACT AT <br />10' - 0" AFF <br />(N) GYP BD CEILING <br />AT 10' - 11" AFF <br />BACKBAR <br />(N) GYP BD CEILING <br />AT 9' - 6" AFF <br />(N) SOFFIT AT 7'-6" AFF <br />(SG) <br />(N) SOFFIT AT 11'-10" AFF <br />(N) HEADER <br />AT 9' - 6" AFF <br />(N) 2X4 ACT ABOVE RO <br />& WH AT 12'-6" AFF <br />(N) GYP BD CEILING <br />AT 9' - 0" AFF <br />(N) GYP BD CEILING <br />AT 9' - 0" AFF <br />(N) GYP BD CEILING <br />AT 9' - 0" AFF <br />(N) GYP BD CEILING <br />AT 10' - 11" AFF <br />L 21774 <br />(3) <br />(32) <br />(6) <br />L 21772 (14) <br />L 21772 <br />(4) <br />(6) <br />(2) <br />(2) <br />(2) <br />(2) <br />(N) HEADER <br />AT 7' - 6" AFF <br />L 22216 <br />L 22216 <br />L 22220 <br />L 22220 <br />L 22216 <br />(7) <br />L 21776 <br />UPLIGHT:C <br />DOWNLIGHT:C <br />UPLIGHT:C <br />DOWNLIGHT:B <br />+ <br />(N) ZINTRA <br />ACOUSTICAL <br />BAFFLES AT <br />11' - 2" AFF <br />L 19411 <br />L 21779 (3) <br />L 19409 <br />L 21779 <br />L 19409 <br />L 21779 (2) <br />L 19409 <br />L 21779 <br />L 19409 <br />L 21779 <br />TYP. <br />22w/22EB 22w 22w <br />22w/22EB 22w <br />22w 22w <br />22w <br />22p22p22p <br />22p/22EB 22p 22p <br />22u 22u <br />22u <br />22v/22EB <br />22v <br />24b <br />24b24b <br />24b/24EB <br />24b24b <br />24b <br />24b 24b 24b 24b <br />24b <br />24b <br />24b/24EB <br />24c 24b 24b 24b 24b 24b <br />24b24b24b24b24b24b24b24b24b24b24b24b24b24b24b24b24b/24EB <br />24b 24b/24EB 24b <br />24r <br />24b24b24b24b24b24b24b24b24b24b24b24b/24EB <br />24r <br />24r <br />24r <br />24r <br />24r <br />24r <br />22n <br />22n <br />22n <br />24t <br />24t <br />24t <br />24t/24EB24t/2EB <br />24t <br />24r <br />24t 24t <br />24r <br />24r <br />24r <br />24NL/24EB <br />22NL/22EB <br />24b <br />24c <br />22u <br />1 <br />24b <br />5 <br />6 <br />4 <br />4 <br />7 <br />3 PETERS CANYON RD. STE 110 <br />IRVINE, CA 92606 <br />D <br />G <br />ESI <br />N <br />| <br />ARCHITECTURE <br />H E S T I A A T E L I E R <br />SHEET NUMBER: <br />SHEET TITLE: <br />SCALE: AS SHOWN <br />STORE #: <br />PROJECT #: <br />PR <br />O <br />J <br />E <br />C <br />T <br /> <br />N <br />A <br />M <br />E <br />: <br />PR <br />O <br />J <br />E <br />C <br />T <br /> <br />A <br />D <br />D <br />R <br />E <br />S <br />S <br />: <br />C 2020 STARBUCKS COFFEE COMPANY <br />R <br />ISSUE DATE: <br />2401 UTAH AVENUE SOUTH <br />SEATTLE, WASHINGTON 98134 <br />(206) 318-1575 <br />THESE DRAWINGS AND THE PROJECT MANUAL <br />ARE CONFIDENTIAL AND SHALL REMAIN THE <br />SOLE PROPERTY OF STARBUCKS <br />CORPORATION, WHICH IS THE OWNER OF THE <br />COPYRIGHT IN THIS WORK. THEY SHALL NOT <br />BE REPRODUCED (IN WHOLE OR IN PART), <br />SHARED WITH THIRD PARTIES OR USED IN ANY <br />MANNER ON OTHER PROJECTS OR <br />EXTENSIONS TO THIS PROJECT WITHOUT THE <br />PRIOR WRITTEN CONSENT OF STARBUCKS <br />CORPORATION. THESE DRAWINGS AND <br />SPECIFICATIONS ARE INTENDED TO EXPRESS <br />DESIGN INTENT FOR A PROTOTYPICAL <br />STARBUCKS STORE (WHICH IS SUBJECT TO <br />CHANGE AT ANYTIME) AND DO NOT REFLECT <br />ACTUAL SITE CONDITIONS. NEITHER PARTY <br />SHALL HAVE ANY OBLIGATION NOR LIABILITY TO <br />THE OTHER (EXCEPT STATED ABOVE) UNTIL A <br />WRITTEN AGREEMENT IS FULLY EXECUTED BY <br />BOTH PARTIES. <br />STARBUCKS R <br />DESIGN MANAGER: <br />PRODUCTION DESIGNER: <br />CHECKED BY: <br />STARBUCKS TEMPLATE VERSION: i2021.04.23 <br />76085-018 <br /><XX-XX-XXXX> <br />TU <br />S <br />T <br />I <br />N <br /> <br />& <br /> <br />S <br />A <br />N <br />T <br />A <br />CL <br />A <br />R <br />A <br />23 <br />0 <br />1 <br /> <br />N <br /> <br />T <br />U <br />S <br />T <br />I <br />N <br /> <br />A <br />V <br />E <br />, <br /> <br />S <br />A <br />N <br />T <br />A <br />AN <br />A <br />, <br /> <br />C <br />A <br />, <br /> <br />9 <br />2 <br />7 <br />0 <br />5 <br />51969 <br />CHARLIE CHANG <br />AMY YANG <br />MAGED GERGES <br />1S <br />T <br /> <br />P <br />E <br />R <br />M <br />I <br />T <br /> <br />S <br />U <br />B <br />M <br />I <br />T <br />T <br />A <br />L <br /> <br />S <br />E <br />T <br /> <br />- <br /> <br />0 <br />4 <br />/ <br />1 <br />6 <br />/ <br />2 <br />0 <br />2 <br />4 <br />Revision Schedule <br />Rev Date By Description <br />E200 <br />LIGHTING PLAN <br />SCALE:1/4" = 1'-0"1 LIGHTING PLAN <br />REFERENCE NOTES <br />NEW LUTRON SWITCHBANK, REFER TO LUTRON ONE-LINE AND LOOP LAYOUT. <br />LIGHT SWITCHES ARE SPECIFIED ON LUTRON ONE-LINE. <br />NEW EMERGENCY/EXIT FIXTURE, GC TO PERFORM TEST TO ENSURE <br />EMERGENCY BATTERY UNIT WILL PROVIDE BACKUP POWER FOR MINIMUM 90 <br />MINUTES. <br />ROUTE CIRCUIT VIA LUTRON VIVE SYSTEM TIME CLOCK. <br />DASHED LINE INDICATES LED LIGHT TAPE HOUSED WITHIN SOFFIT LIGHT <br />COVE. <br />DASHED LINE INDICATES LED LIGHT TAPE HOUSED UNDERSIDE UPPER CBE <br />CABINETRY. <br />DASHED LINE INDICATES LED LIGHT TAPE HOUSED UNDERSIDE FRONTLINE <br />COUNTERTOP BELOW. <br />DASHED LINE INDICATES LED LIGHT TAPE HOUSED UNDERSIDE PARTNER <br />REST UPPER CABINETRY. <br />1 <br />2 <br />3 <br />4 <br />5 <br />6 <br />7 <br />A.PROVIDE A DISCONNECTING MEANS FOR EACH MULTI-WIRE LIGHTING <br />BRANCH CIRCUIT IN ACCORDANCE WITH NEC 410.130(G)(1)THRU(3). <br />DISCONNECTING MEANS SHALL BE LOCATED AT POINT WHERE CIRCUIT <br />ORIGINATES AND SHALL SIMULTANEOUSLY DISCONNECT ALL <br />UNGROUNDED CONDUCTORS. <br />B.REFER TO ARCHITECTURAL REFLECTED CEILING PLAN FOR EXACT <br />LOCATION AND ELEVATION OF ALL LIGHTING FIXTURES. <br />C.THE FIXTURE SCHEDULE INDICATES GENERAL DESCRIPTION OF LIGHTING <br />FIXTURES AND MANUFACTURERS CATALOG NUMBERS. IT SHALL BE THE <br />CONTRACTORS RESPOSIBILITY TO VERIFY EXACT CEILING CONSTRUCTION <br />WITH ARCHITECTURAL REFLECTED CEILING PLAN AND PROVIDE LIGHTING <br />FIXTURES WITH ALL NECESSARY TRIMS, AND MOUNTING HARDWARE. <br />D.COORDINATE EXACT LIGHTING FIXTURE LOCATIONS WITH ELECTRICAL, <br />MECHANICAL, PLUMBING EQUIPMENT, INCLUDING CONDUIT, PIPING, <br />DUCTING ,ETC PRIOR TO ROUGH-IN. <br />E.ALL RECESSED FIXTURES SHALL BE PROVIDED WITH ALL REQUIRED <br />STRUCTURAL SUPPORTS AS REQUIRED BY THE CURRENTLY ADOPTED <br />ISSUE OF THE BUILDING CODE, AS WELL AS ANY LOCAL CODES. <br />F.ALL DIMMING BRANCH CIRCUITS SHALL BE PROVIDED WITH A DEDICATED <br />NEUTRAL CONDUCTOR FOR EACH ZONE/CHANNEL. <br />G.ALL EMERGENCY BATTERY PACK FIXTURES SHALL BE PROVIDED WITH A <br />CONSTANT HOT CONNECTION TO THE CHARGING LEAD OF THE LOCAL <br />AREA CIRCUIT. <br />H.REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR EXIT SIGN <br />CHEVRONS AND NUMBER OF FACES PER EXIT SIGN. ANY DISCREPANCIES <br />BETWEEN EXIT SIGNS SHOWN ON THE ELECTRICAL AND ARCHITECTURAL <br />PLANS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT PRIOR <br />TO ORDERING EXIT SIGNS. A JUNCTION BOX MUST BE PROVIDED WITH ALL <br />EXIT LIGHTS CONNECTED TO MORE THAN ONE SET OF CONDUCTORS <br />UNLESS THE EXIT LIGHT FIXTURE IS FURNISHED WITH AN APPROVED <br />OUTLET BOX FOR THROUGH WIRING. <br />I.ALL LOW VOLTAGE LIGHTING SYSTEMS SHALL COMPLY WITH NEC 411 AND <br />SHALL BE LISTED PER 411.3 OR LOCAL CODES HAVING JURISDICTION. <br />J.ALL ELECTRICAL EQUIPMENT LOCATED OUTSIDE SHALL BE <br />WEATHERPROOF. <br />K.ALL LOW VOLTAGE WIRING NOT RUN IN CONDUIT SHALL BE PLENUM RATED. <br />L.MOUNT ALL SWITCHES, CONTROLS, RECEPTACLES BETWEEN 15"-48" AFF. <br />H.ADDITIONAL RELAY ZONES MAY BE REQUIRED FOR THE ADDITION OF <br />PRIMARY DAYLIT, SECONDARY DAYLIT, AND PRIMARY SKYLIT UTILIZING THE <br />SAME CONTROL CHANNEL. (I.E. EVEN THOUGH A SINGLE LETTER "a" IS <br />INDICATED AT THE PRIMARY SENSOR), ADDITIONAL RELAYS WOULD BE <br />REQUIRED FOR THE: <br />"a+"PRIMARY SIDELIT DAYLIT ZONE <br />"a++"SECONDARY SIDELIT DAYLIT ZONE, AND <br />"a*"SKYLIT DAYLIT ZONE <br />WHERE MORE THAN ONE CIRCUIT /THREE SWITCH LEGS/THREE RELAY <br />ZONES ARE REQUIRED PROVIDE ADDITIONAL FULL FEATURE CONTROL <br />UNITS AS REQUIRED. <br />I.LUMINAIRES INDICATED AS EMERGENCY SHALL BE IDENTIFIED / PROVIDED <br />AS FOLLOWS: <br />-FIXTURE CONNECTED TO CIRCUIT "3", CONTROL SWITCH <br />"a" - WITH THE BATTERY CHARGING LEAD CONNECTED <br />TO A CONSTANT HOT CIRCUIT "3". <br />-FIXTURE CONNECTED TO A CONSTANT HOT CIRCUIT "#3". <br />BATTERY CHARGING LEAD CONNECTED TO A CONSTANT <br />HOT CIRCUIT "3". <br />-ROUTED THROUGH A U.L. LISTED TRANSFER RELAY (LC & <br />D # GR - 2001E/S) FOR SWITCHED CONTROL OR A U.L. <br />LISTED TRANSFER SWITCH (BODINE #GTD SERIES <br />DEVICE) FOR DIMMING CONTROLS . CONNECTED TO A <br />CONSTANT HOT EMERGENCY CIRCUIT "3". <br />-FIXTURE CONNECTED TO A CONSTANT HOT EMERGENCY <br />CIRCUIT "#3". <br />1.INTEGRAL BATTERY PACK (EB): <br />3a/3EB <br />3NL/3EB <br />3a/3EM <br />3NL/3EM <br />2.REMOTE BACK-UP SOURCE (EM) <br />LIGHTING PLAN GENERAL NOTES <br />(E) <br />STAMP DATE: 04/13/2024 <br />PR <br />O <br />J <br />E <br />C <br />T <br /> <br />N <br />A <br />M <br />E <br />: <br />PR <br />O <br />J <br />E <br />C <br />T <br /> <br />A <br />D <br />D <br />R <br />E <br />S <br />S <br />: <br />TU <br />S <br />T <br />I <br />N <br /> <br />& <br /> <br />S <br />A <br />N <br />T <br />A <br />CL <br />A <br />R <br />A <br />23 <br />0 <br />1 <br /> <br />N <br /> <br />T <br />U <br />S <br />T <br />I <br />N <br /> <br />A <br />V <br />E <br />, <br /> <br />S <br />U <br />I <br />T <br />E <br /> <br />A <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br />, <br /> <br />9 <br />2 <br />7 <br />0 <br />5 <br />STORE #: <br />PROJECT #: <br />ISSUE DATE: <br />DESIGN MANAGER: <br />PRODUCTION DESIGNER: <br />CHECKED BY: <br />76085-018 <br />04-15-2024 <br />51969 <br />CHARLIE CHANG <br />SEPIDEH SHARIFI <br />MAGED GERGES <br />2301 N Tustin Ave <br />#A8/22/2024