Laserfiche WebLink
Page 5 of 8 <br />1760 Chicago Ave Ste J13, Riverside, CA 92507 (951) 405-1733 info@currentrenewableseng.com <br />Roof Framing Checks: <br />Force Checks <br />LC1: D+S Check 1 <br />Applied Moment (lb-ft):175.2 <br />Applied Shear (lbs):105.1 <br />Allowable Moment (lb-ft):455.6 <br />Allowable Shear (lbs):724.5 <br />Moment DCR:0.385 <br />Shear DCR:0.145 <br />LC2: D+0.6W Check 1 <br />Applied Moment (lb-ft):350.4 <br />Applied Shear (lbs):210.1 <br />Allowable Moment (lb-ft):633.9 <br />Allowable Shear (lbs):1,008.0 <br />Moment DCR:0.553 <br />Shear DCR:0.208 <br />LC3: D+0.75(S+0.6W)Check 1 <br />Applied Moment (lb-ft):306.6 <br />Applied Shear (lbs):183.9 <br />Allowable Moment (lb-ft):633.9 <br />Allowable Shear (lbs):1,008.0 <br />Moment DCR:0.484 <br />Shear DCR:0.182 <br />LC4: 0.6D+0.6W Check 1 <br />Applied Moment (lb-ft):280.3 <br />Applied Shear (lbs):168.1 <br />Allowable Moment (lb-ft):633.9 <br />Allowable Shear (lbs):1,008.0 <br />Moment DCR:0.442 <br />Shear DCR:0.167 <br />2218 S Artesia St- 101118868 & <br />20182517 <br />4/11/2024