<br />A. Reinforcement for Grab Bars (R32711)
<br />AGING -IN -PLACE ELEMENTS - AT LEAST ONE BATHROOM ON THEE
<br />RY LEVEL SHALL BE PROVIDED WITH
<br />REINFORCEMENT INSTALLED IN ACCORDANCE WITH THIS SECTION. WHE
<br />RE THERE IS NO BATHROOM ON THE ENTRY
<br />LEVEL, AT LEAST ONE BATHROOM ON THE SECOND OR THIRD FLOOR
<br />DF THE DWELLING SHALL COMPLY WITH
<br />THIS SECTION.
<br />f
<br />1. REINFORCEMENT SHALL BE SOLID LUMBER OR OTHER CONSTRUCTI
<br />MATERIALS APPROVED BY THE
<br />ENFORCING AGENCY.
<br />2. REINFORCEMENT SHALL NOT BE LESS THAN 2x8 NOMINAL LUMBER
<br />(1-1/2 INCH X 7-1/4 INCH ACTUAL
<br />DIMENSION) OR OTHER CONSTRUCTION MATERIAL PROVIDING EQUA
<br />HEIGHT AND LOAD CAPACITY.
<br />REINFORCEMENT SHALL BE LOCATED BETWEEN 32 INCHES AND 3
<br />1 /4 INCHES ABOVE THE FINISHED
<br />FLOOR FLUSH WITH THE WALL FRAMING.
<br />3. WATER CLOSET REINFORCEMENT SHALL BE INSTALLED ON BOTH SI
<br />E WALLS OF THE FIXTURE, OR ONE
<br />SIDE WALL AND THE BACK WALL.
<br />4. SHOWER REINFORCEMENT SHALL BE CONTINUOUS WHERE WALL FRA
<br />MING IS PROVIDED.
<br />5. BATHTUB AND COMBINATION BATHTUB/SHOWER REINFORCEMENTS
<br />IALL BE CONTINUOUS ON EACH END OF
<br />THE BATHTUB AND THE BACK WALL. ADDITIONALLY, BACK WALL
<br />INFORCEMENT FOR A LOWER GRAB BAR
<br />SHALL BE PROVIDED WITH THE BOTTOM EDGE LOCATED NO MORE
<br />-HAN 6 INCHES ABOVE THE BATHTUB RIM.
<br />EXCEPTIONS:
<br />6. WHERE THE WATER CLOSET IS NOT PLACED ADJACENT TO A SIDE
<br />WALL CAPABLE OF ACCOMMODATING
<br />A GRAB BAR, THE BATHROOM SHALL HAVE PROVISIONS FOR INST
<br />LATION OF FLOOR -MOUNTED,
<br />FOLDAWAY, OR SIMILAR ALTERNATE GRAB BAR REINFORCEMENTS
<br />PROVED BY THE ENFORCING AGENCY.
<br />B,
<br />DOCUMENTATION FOR GRAB BAR REINFORCEMENT - [R327.1.1.1 ] INF
<br />MATION AND/OR GS 'G
<br />LOCATION OF GRAB BAR REINFORCEMENT SHALL BE PLACED IN THE
<br />PERATION AND INTENAN MANUA IN
<br />ACCORDANCE WITH THE CALIFORNIA GREEN BUILDING STANDARDS C
<br />E, CHAPTER 4, ON 4.
<br />C.
<br />ELECTRICAL RECEPTACLE OUTLET, SWITCH AND CONTROL HEIGHTS [
<br />27.1.2]- ELECT AL RE CE CLE Ol E
<br />SWITCHES, AND CONTROLS (INCLUDING CONTROLS FOR HEATING, VEN
<br />LATION AND AIR ONDITIONI
<br />INTENDED TO BE USED BY OCCUPANTS SHALL BE LOCATED NO MOR
<br />THAN 48" MEAS ED FROM
<br />THE TOP OF THE OUTLET BOX AND NOT LESS THAN 15" MEASURED
<br />ROM THE BOTTOM OF OUTLET
<br />BOX ABOVE THE FINISH FLOOR.
<br />D.
<br />INTERIOR DOORS. [R327.1.3] EFFECTIVE JULY 1, 2024, AT LEAST ON
<br />BATHROOM AND ONE BEDROOM ON THE
<br />ENTRY LEVEL SHALL PROVIDE A DOORWAY WITH A NET CLEAR OPEN
<br />G OF NOT LESS THAN 32",
<br />MEASURED WITH THE DOOR POSITIONED AT AN ANGLE OF 90 DEGRE
<br />FROM THE CLOSED POSITION; OR,
<br />IN THE CASE OF A 2- OR -3 STORY SINGLE FAMILY DWELLING, ON
<br />E 2nd or 3rd FLOOR OF THE
<br />DWELLING IF A BATHROOM OR BEDROOM IS NOT LOCATED ON THE E
<br />TRY LEVEL.
<br />E.
<br />DOORBELL BUTTON. [327.1.4] DOORBELL BUTTONS OR CONTROL, WH
<br />INSTALLED, SHALL NOT EXCEED 48"
<br />ABOVE EXTERIOR FLOOR OR LANDING, MEASURED FROM THE TOP OF
<br />HE DOORBELL BUTTON ASSEMBLY.
<br />WHERE DOORBELL BUTTONS INTERGRATED WITH OTHER FEATURES AR
<br />REQUIRED TO BE INSTALLED ABOVE
<br />48" MEASURED FROM THE EXTERIOR FLOOR OR LANDING, A STANDA
<br />DOORBELL BUTTON OR CONTROL
<br />SHALL ALSO BE PROVIDED AT A HEIGHT NOT EXCEEDING 48" ABOVE
<br />EXTERIOR FLOOR OR LANDING,
<br />MEASURED FROM THE TOP OF THE DOORBELL BUTTON OR CONTROL.
<br />ELECTRIC —READY REQUIREMENTS ON PLANS:
<br />A- HEAT PUMP SPACE HEATER READY. SYSTEM USING GAS OR PROPAI E FURNACE TO SERVE INDIVIDUAL
<br />DWELLING UNITS SHALL INCLUDE THE FOLLOWING:
<br />1. A DEDICATED 240 VOLT BRANCH CIRCUIT WIRING SHALL BE INSTA LED WITHIN 3 FT. FROM THE
<br />FURNACE AND ACCESSIBLE TO THE FURNACE WITH NO OBSTRUCT NS. T CIRCUIT
<br />CONDUCTORS SHALL BE RATED AT 30 AMPS MINIMUM. THE BLA COVEVBRANIC-w
<br />IDENTIFIED AS
<br />"240 READY".2. THE MAIN ELECTRICAL SERVICE PANEL SHALL HAVE A RESERVED PACE tRINSTALLATION OF A DOUBLE POLE CIRCUIT BREAKER FOR A FUTU E HEA P EA R
<br />INSTALLATION. THE RESERVED SPACE SHALL BE PERMANENTLY RKED R --U 4
<br />USE."
<br />B- ELECTRIC COOKTOP READY. SYSTEM USING GAS OR PROPANE FURN ICE TO SERVE INDIVIDUAL
<br />DWELLING UNITS SHALL INCLUDE THE FOLLOWING:
<br />1. A DEDICATED 240 VOLT BRANCH CIRCUIT WIRING SHALL BE INSTA LED WITwI"' '� FT. FROM THE
<br />COOKTOP AND ACCESSIBLE TO THE COOKTOP WITH NO OBSTRUCI DNS.UA
<br />CIRCUIT
<br />CONDUCTORS SHALL BE RATED AT 50 AMPS MINIMUM. THE BLA COVE iut. 'TI
<br />"240 READY".
<br />2. THE MAIN ELECTRICAL SERVICE PANEL SHALL HAVE A RESERVED PACEF TINSTALLATION OF A DOUBLE POLE CIRCUIT BREAKER FOR A FUTU E ELE
<br />INSTALLATION. THE RESERVED SPACE SHALL BE PERMANENTLY RKED AS "" FOR FUTURE 240V
<br />USE."
<br />C- ELECTRIC CLOTHES DRYER READY. SYSTEM USING GAS OR PROPANE FURNACE TO SERVE INDIVIDUAL
<br />DWELLING UNITS SHALL INCLUDE THE FOLLOWING:
<br />1. A DEDICATED 240 VOLT BRANCH CIRCUIT WIRING SHALL BE INSTA LED WITHIN 3 FT. FROM THE
<br />CLOTHES DRYER AND ACCESSIBLE TO THE CLOTHES DRYER WITH 10 OBSTRUCTIONS. THE BRANCH
<br />CIRCUIT CONDUCTORS SHALL BE RATED AT 30 AMPS MINIMUM. E BLANK COVER SHALL BE
<br />IDENTIFIED AS "240 READY".
<br />2. THE MAIN ELECTRICAL SERVICE PANEL SHALL HAVE A RESERVED PACE TO ALLOW FOR THE
<br />INSTALLATION OF A DOUBLE POLE CIRCUIT BREAKER FOR A FUTU E ELECTRIC CLOTHES DRYER
<br />INSTALLATION. THE RESERVED SPACE SHALL BE PERMANENTLY
<br />USE."
<br />ALL SIGNLE-FAMILY RESIDENCES THAT INCLUDE ONE OR TWO DWELLING UNITS SHALL MEET
<br />THE FOLLOWING: [150.0(S)]
<br />A. AT LEAST ONE OF THE FOLLOWING SHALL BE PROVIDED:
<br />1. ESS READY INTERCONNECTION EQUIPMENT WITH A MINIMUM BACKED -UP CAPACITY
<br />OF 60 AMPS AND A MINIMUM OF FOUR ESS-SUPPLIED BRANCH CIRCUIT; OR
<br />2. A DEDICATED RACEWAY FROM THE MAIN SERVICE TO PANELBOARD (SUBPANEL)
<br />THAT SUPPLIES THE BRANCH CIRCUITS IN SEC. 150.0(S)(2). ALL BRANCH
<br />CIRCUITS ARE PERMITTED TO BE SUPPLIED BY THE MAIN SERVICE PANEL PRIOR TO
<br />THE INSTALLATION OF AN ESS. THE TRADE SIZE OF THE RACEWAY SHALL BE
<br />NOT LESS THAN 1 INCH. THE PANELBOARD THAT SUPPLIES THE BRANCH
<br />CIRCUITS (SUBPANEL) MUST BE LABELED "SUBPANEL SHALL BE INCLUDE ALL
<br />BACKED -UP LOAD CIRCUITS."
<br />B. A MINIMUM OF FOUR BRANCH CIRCUITS SHALL BE IDENTIFIED AND HAVE THEIR SOURCE
<br />OF SUPPLY COLLOCATED AT A SINGLE PANELBOARD SUITABLE TO BE SUPPLIED BY THE ESS.
<br />AT LEAST ONE CIRCUIT SHALL SUPPLY THE REFIRGERATOR, ONE LIGHTING CIRCUIT SHALL BE
<br />LOCATED NEAR THE PRIMARY EGRESS AND AT LEAST ONE CIRCUIT SHALL SUPPLY A
<br />SLEEPING ROOM RECEPTACLE OUTLET.
<br />C. THE MAIN PANELBOARD SHALL HAVE A MINIMUN BUSBAR RATING OF 225 AMPS.
<br />D. SUFFICIENT SPACE SHALL BE RESERVED TO ALLOW FUTURE INSTALLATION OF A SYSTEM
<br />ISOLATION EQUIPMENT/TRANSFER SWITCH WITHIN 3 FT. OF THE MAIN PANELBOARD.
<br />RACEWAYS SHALL BE INSTALLED BETWEEN THE PANNELBOARD AND THE SYSTEM ISOLATION
<br />EQUIPMENT/TRANSFER SWITCH LOCATION TO ALLOW THE CONNECTION OF BACKUP POWER
<br />SOURCE.
<br />WIRING DEV
<br />15" AND J
<br />CRC 32
<br />HALL BE BETWEEN
<br />,E FINISH FLOOR. WALL STUD
<br />MIN.
<br />FINISH FACE
<br />OF FLOOR
<br />AGINGTHE CBATHROOM
<br />CAUFORNIA ENERGY NOTES ■
<br />1. ALL NEW GLAZING WILL BE INSTALLED WITH LABELS TO REMAIN
<br />IN PLA�� FD
<br />TION.
<br />2. L PE ASTALLED LIGHTING IN OTHER ROOMS, INCLUDING
<br />ALLW S, BEDROOMS, FAMILY ROOMS, MUST BE HIGH
<br />EFFICA OL ED BY DIMMER, OR A MANUAL -ON OCCUPANCY
<br />SENSO T-ON OCCUPANCY SENSORS ARE BEING MANUFACTURED
<br />AND A A Tr EXCEPTION TO THIS IS A CLOSET UNDER 70' SF.,
<br />e,.o AND 1 HS FOR LAMPS.
<br />3. RECESSED LIGHTS INSTALLED IN AN INSULATED CEILING OR CAVITY ARE
<br />REQUIRED TO HAVE A ZERO CLEARANCE INSULATION COVER (IC); BE
<br />ASTM E 283 CERTIFIED THAT THEY ARE AIR TIGHT; AND SEALED WITH A
<br />GASKET OR CAULK BETWEEN THE HOUSING AND THE CEILING.
<br />4. OUTDOOR LIGHTING THAT IS ATTACED TO A BUILDING MUST BE HIGH EFFICACY;
<br />OR CONTROLLED BY A MOTION SENSOR WITH AN INTEGRAL PHOTO -CONTROL.
<br />LIGHTING AROUND SWIMMING POOLS, WATER FEATURES, OR OTHER LOCATIONS
<br />SUBJECT TO ARTICLE 680 OF THE CEC ARE EXEMPT.
<br />HIGH EFFICACY LUMINAIRES MUST BE PIN BASED.
<br />KEYNOTES
<br />(N)
<br />300
<br />AMP.
<br />PANEL WITH DUAL METER.
<br />1❑
<br />(1)
<br />200
<br />AMP.
<br />FOR ADU
<br />(1)
<br />100
<br />AMP.
<br />FOR EX. HOUSE
<br />�2
<br />(N)
<br />200
<br />AMP.
<br />SUBPANEL FOR ADU
<br />Date:
<br />COC ER. FOR *yN JrD CCTORSItA TO�EIFCLA
<br />L BE
<br />A U UREN H 6 AWG,
<br />AND LARGER, SEE SEC.310 CEC.
<br />EXCEPTION: ALUMINUM CONDUCTORS SM
<br />LER THAN #6 AWG
<br />MAY BE USED PROVIDED THE METHOD 0
<br />CONNECTION IS
<br />APPROVED IN ADVANCE BY THE BUILDIN
<br />OFFICIAL AND THE
<br />INSTALLATION IS MADE UNDER CONTINUO
<br />S SPECIAL INSPECTION.
<br />2. IN EVERY DWELLING UNIT, FIXED APPLIANCE
<br />SUCH AS FOOD WASTE
<br />GRINDERS, DISHWASHER, WASHING MACHINE
<br />DRYERS, LAUNDRY
<br />TRAY LOCATIONS, BUILT—IN REFRIGERATORS
<br />R FREEZERS, FURNACE,
<br />AC UNITS, BUILT-INS HEATERS OR ANY OTH
<br />FIXED APPLIANCE WITH
<br />A MOTOR OF 1 /4 I.P. OR LARGE SHALL BE
<br />N A SEPERATE 20 AMP.
<br />BRANCH CIRCUIT.
<br />3. RECEPTACLES SHALL BE LISTED AS TAMPER
<br />RESISTANT FOR ALL 15
<br />AND 20 AMP. RECEPTACLES IN DWELLING U
<br />T FAMILY, DINING, LIVING,
<br />PARLORS, LIBRARIES, DENS BEDROOMS, SUN
<br />OOMS, RECREATION ROOMS,
<br />CLOSETS, HALLWAYS, OR SIMILAR ROOMS A
<br />AREAS PER CEC SEC
<br />210.52
<br />4. ALL WALL SPACES, 2' OR MORE IN WIDTH,
<br />ALL HAVE RECEPTACLES
<br />INSTALLED SUCF: THAT NO POINT MEASURE
<br />HORIZONTALLY IS MORE
<br />THAN 6' FROM A KI t.,t, ,CLE (12' MAXIMU
<br />SPACING).
<br />5. IN CLOSETS, LUMI�MF� - SHALL BE (a) SURF
<br />E-MOUNTED OR RECESSED
<br />INCANDESCENT WI - �-1 ': OMPLETELY ENCLOSED
<br />AMPS, (b) SURFACE
<br />MOUNTED OR RECESSED FLUORESCENT LUMI
<br />IRES, (c) SURFACE
<br />MOUNTED OR LED LUMINARIES IDENTIFIED A
<br />SUITABLE FOR INSTALLATION
<br />WITHIN STORAGE AREAS. MINIMUM CLEARAN
<br />S BETWEEN LUMINAIRES
<br />AND HE EST POINT OF STORAG SPAC
<br />SHALL BE AS FOLLOW.
<br />a SURFACE -MOUNTED INCAN
<br />ESCENT OR LED LUMINARIES
<br />CLOSED LIGHT I
<br />TALLIED ON THE WALL
<br />E R OR ON THE COLIN
<br />b FOR ACE MOUNTED FLUOR E
<br />CENT LUMINARIES INSTALLED
<br />THE L THE DOOR OR
<br />N THE CEILING.
<br />NJ
<br />c RE INCANDESCENT
<br />LED LUMINARIES WITH A
<br />MID ETELY CLOSED LIGHT INSTAL
<br />D IN THE WALL OR CEILING.
<br />d. "FOR RE, SSED FLUORESCENT L
<br />INARIES INSTALLED IN THE
<br />_ . CEI_
<br />e. SURFACE -MOUNTED FLUORESCENT
<br />LED LUMINARIES INSTALLED
<br />WITHIN STORAGE SPACE WHERE IDEN
<br />IED FOR THIS USE.
<br />OCARBON MONOXIDE/SMOKE
<br />ALARM SHALL BE
<br />LISTED AS COMP[ YIN'.;
<br />W/ THE REQUIREML-,,nT'
<br />OF UL 2034
<br />'MBATHROOM EXHAUST:
<br />50 CUBIC FEET PER MINUTE
<br />FOR INTERMITTENT VENTILATION;
<br />25 CUBIC FEET PER MINUTE
<br />FOR CONTINUOUS VENTILATION.
<br />THE EXHAUST FAN SHALL BE
<br />CERTIFIED AND LISTED ON THE
<br />CALIFORNIA ENERGY COMMISION
<br />MANUFACTURER: AIRZONE
<br />MODEL#: PA900V
<br />BPT14-14A
<br /><a> PROVIDE AN EXHAUST FAN
<br />WITH A MINIMUM FLOW RATE
<br />OF 280 CFM IN KITCHEN
<br />® RHEEM WATER HEATER
<br />ELECTRIC HEAT PUMP
<br />MODEL# PROPH40 T2 RH37515
<br />SEE SPECS ON SHEET A-6
<br />© RECEPTACLE OUTLET
<br />FOR ATTIC
<br />HOUSE VENTILATION FAN-45 CFM
<br />BROAN— NUTONE FAN 80 CFM
<br />MODEL# AEN80
<br />SEE SPECS ON SHEET A-7
<br />® HVAC HEATPUMP
<br />INDOOR UNIT
<br />OUTDOOR UNIT
<br />FKUFU�)tU HUU U I I LI I Y FLAIN
<br />SCALE: 1 /4" 1 '
<br />" EF A \\III
<br />AF RC -FAULT RCU TER WA
<br />DU �� . ET --RESINT
<br />O Fci GROUND FAULT CIRCUIT INTERRUPTERS
<br />DUPLEX OUTLET - TAMPER -RESISTANT
<br />�AFCI ARC -FAULT CIRCUIT INTERRUPTERS &
<br />cFci GROUND FAULT CIRCUIT INTERRUPTERS
<br />DUPLEX OUTLET - TAMPER -RESISTANT
<br />0 HUMIDISTAT FAN
<br />EXHAUST FAN SHALL BE VENTED DIRECTLY TO THE OUTSIDE
<br />CAPABLE OF PROVIDING 50 CFM. MIN. MAXIMUM 3.0 SONE
<br />* W/ FLUORESCENT LIGHT IF REQUIRED
<br />- LED CAN LIGHTING ARC -FAULT
<br />CIRCUIT INTERRUPTERS
<br />LED WALL MOUNT SCONCE LIGHT
<br />(OWNER PROVIDED FIXTURE)
<br />MOTION & PHOTO SENSORED
<br />(OWNER PROVIDED FIXTURE)
<br />O CARBON MONOXIDE DETECTOR HARDWIRED
<br />"MD EQUIPPED WITH BATTERY BACKUP.
<br />SMOKE DETECTOR - UL 217 RATED
<br />ALL SMOKE DETECTORS HARD WIRED WITH BATTERY
<br />BACKUP AND MUST SOUND AN AUDIBLE ALARM IN ALL
<br />SLEEPING AREAS.
<br />(BATTERY UNITS O.K. AT EXISTING ROOMS)
<br />® HARD WIRED SMOKE DETECTOR - UL 217 RATED
<br />W/ PHOTO -ELECTRIC TYPE.
<br />DIMMER
<br />VACANCY SENSOR
<br />MOTION SENSOR SWITCH
<br />(THE WATT STOPPER-500W)
<br />THREE WAY SWITCH
<br />® AIR REGISTER
<br />® RETURN AIR GRILLE - CEILING
<br />HOSE BIB WITH
<br />ANTI SYPHON (UPC 603.7)
<br />SMOKE ALARMS SHALL BE PROVIDED IN ALL NEW
<br />CONSTRUCTION LOCATED IN EACH SLEEPING ROOM,
<br />OUTSIDE EACH SEPARATE SLEEPING AREA IN THE
<br />IMMEDIATE VICINITY OF THE BEDROOMS, AND AT
<br />EACH ADDITIONAL FLOOR OR BASEMENT LEVEL.
<br />- ALL EXTERIOR LIGHTINGS SHALL BE
<br />FLOURESCENT / LED OR MOTION & PHOTO SENSORED
<br />ALL RECEPTACLE OUTLETS SHALL BE LISTED
<br />TAMPER -RESISTANT RECEPTACLE PER CEC 406.11.
<br />NOTES
<br />1. SMOKE DETECTOR SHALL BE INTERCONNECTED SUCH THAT
<br />THE ACTIVATION OF ONE ALARM WILL ACTIVATE ALL ALARMS.
<br />2. CARBON MONOXIDE ALARMS SHALL BE INTERCONNECTED
<br />SUCH THAT THE ACTIVATION OF ONE ALARM WILL ACTIVATE
<br />ALL ALARMS.
<br />SMOKE ALARM AND DETECTORS WILL BE INSTALLED AND MAINTAINED
<br />ACCORDING TO MANUFACTURER'S INSTRUCTIONS.
<br />ALL SERVICES SUPPLYING DWELLING UNITS SHALL BE
<br />PROVIDED WITH TYPE 1 OR TYPE 2 SURGE —PROTECTIVE
<br />DEVICE (SPD). (CEC 230.67) INDICATE THE
<br />SURGE —PROTECTOR TO BE UNTILIZED ON THE PLAN OR
<br />PROVIDE A CUT SHEET FOR THE SERVICE PANEL TO
<br />DEMONSTRATE THAT IS HAS SUCH PROTECTION BUILT INTO
<br />THE SERVICE PANEL.
<br />``. 1" MUL CLEAPAIICE TO
<br />COMBUSTIBLE FIRAN11116
<br />A' V' hilll. FROM WVA L'
<br />- -_ ` -__-
<br />S'-0"MMI. VEIIT TERMIIIATIOtI-- LIGHT FIXTURE
<br />SUPPLY AIR PLEIIUM
<br />OOWII DRAFT DI f E `*
<br />SUPPLY AIR DUCT d
<br />%RETURM AIR �ElIUIM
<br />rtiGAS SHUT OFF VALUE
<br />!SWITCHD1SCOINIEr.T 'i24VE+7UIPMEHTSERVICE,
<br />RECEPTACLELIGHT SWITCH
<br />24' Mill.
<br />'
<br />12" MHI. ABOVE ROOF TO
<br />BOY TOM OF VEIIT CAP
<br />301A30"ATTIC ACCESS I41AY Bf r
<br />REDUCED TO 22-00" Mlll. PROVIDED o.
<br />THE LARGEST PIECE OF EQUIPME11T
<br />CAII BE REMOVED THROU(;H THE oPEHIIIG
<br />Figure 1 — Typical Installation of Forced Air Unit in Residential Project
<br />BY:
<br />P
<br />Westin of
<br />Development Co.
<br />License# 578613
<br />6091 E. Nugget Ct.
<br />Anaheim Hills, CA 92807
<br />weatindevelopment•yahoo.com
<br />Michael Vu
<br />714-878-7430
<br />ENGINEERED BY:
<br />Hiep T. Tran P.E.
<br />2907 Ebbtide Rd.
<br />Corona Del Mar, CA 92625
<br />Tel. (949) 353-7486
<br />WW
<br />A
<br />W
<br />�
<br />x
<br />�
<br />Q
<br />I
<br />y
<br />Z
<br />C\2
<br />W
<br />:4k
<br />E4
<br />w
<br />'-1
<br />�
<br />O
<br />I
<br />W
<br />a
<br />4
<br />a
<br />o2
<br />a,
<br />O
<br />O
<br />H�--I
<br />n
<br />N
<br />n
<br />O�
<br />Job:
<br />Drawn By:
<br />SH-CV
<br />Scale:
<br />Date:
<br />3/27/24
<br />Rev.
<br />Date:
<br />A
<br />6
<br />Proposed ADU Utility
<br />Plan