My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
302 E Santa Clara Ave - Plan
PBA
>
Building
>
ProjectDox
>
S
>
Santa Clara Ave
>
302 E Santa Clara Ave
>
302 E Santa Clara Ave - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/5/2025 7:33:13 AM
Creation date
6/5/2025 7:33:06 AM
Metadata
Fields
Template:
Plan
Permit Number
101120053
Full Address
302 E Santa Clara Ave
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
55
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed <br />as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as <br />to any finding or other matter in this report, or as to any product covered by the report. <br />Copyright © 2014 Page 1 of 1 <br />1000 <br /> <br /> <br />ICC-ES Evaluation Report ESR-1900 CBC and CRC Supplement* Reissued February 2014 <br /> This report is subject to renewal on March 1, 2016. <br />www.icc-es.org | (800) 423-6587 | (562) 699-0543 A Subsidiary of the International Code Council <br />® <br /> <br />DIVISION: 07 00 00—THERMAL AND MOISTURE PROTECTION <br />Section: 07 32 16—Concrete Roof Tiles <br /> <br />REPORT HOLDER: <br /> <br />EAGLE ROOFING PRODUCTS, A DIVISION OF BURLINGAME INDUSTRIES, INC. <br />3546 NORTH RIVERSIDE AVENUE <br />RIALTO, CALIFORNIA 92377 <br />(909) 822-6000 <br />www.eagleroofing.com <br /> <br />EVALUATION SUBJECT: <br /> <br />EAGLE® AND EAGLELITE® INTERLOCKING CONCRETE ROOFING TILES: CAPISTRANO, MALIBU, BEL AIR, ESTATE, <br />DOUBLE EAGLE BEL AIR, PONDEROSA, DOUBLE EAGLE PONDEROSA, GOLDEN EAGLE ARTISAN AND TAPERED <br />ARTISAN. <br /> <br />1.0 REPORT PURPOSE AND SCOPE <br />Purpose: <br />The purpose of this evaluation report supplement is to indicate that the Eagle® and EagleLite® Interlocking Concrete Roof <br />Tiles, recognized in ICC-ES master evaluation report ESR-1900, have also been evaluated for compliance with the codes <br />noted below. <br />Applicable code editions: <br /> 2013 California Building Code (CBC) <br /> 2013 California Residential Code (CRC) <br />2.0 CONCLUSIONS <br />2.1 CBC: <br />The Eagle® and EagleLite® Interlocking Concrete Roof Tiles described in the master report, ESR-1900, may be used where a <br />Class A roof covering complying with CBC Section 1505.1.1, a Class B roof covering complying with CBC Section 1505.1.2, <br />or a Class C roof covering complying with CBC Section 1505.1.3 is required, provided installation is in accordance with the <br />master report and the additional requirements of CBC Sections 1507.3.10 and 1512. <br />The roof tiles may be used in the construction of new buildings located in a Fire Hazard Severity Zone within State <br />Responsibility Areas or any Wildland-Urban Interface Fire Area, provided installation is in accordance with the master report <br />and the additional requirements of CBC Sections 701A.3 and 705A. <br />2.2 CRC: <br />The Eagle® and EagleLite® Interlocking Concrete Roof Tiles described in the master report, ESR-1900, may be used where a <br />Class A roof covering complying with CRC Section R902.1.1, a Class B roof covering complying with CRC Section R902.1.2, <br />or a Class C roof covering complying with CRC Section R902.1.3 is required, provided installation is in accordance with the <br />master report and the additional requirements of CRC Section R905.3. <br />The roof tiles may be used in the construction of new buildings located in any Fire Hazard Severity Zone within State <br />Responsibility Areas or Wildland–Urban Interface Fire Area, provided installation is in accordance with the master report and <br />the additional requirements of Sections R327.1.3.1 and R327.5 of the CRC. <br />The products recognized in this supplement have not been evaluated for compliance with the International Wildland–Urban <br />Interface Code®. <br />This supplement expires concurrently with the master report reissued February 2014, revised June 2014. <br />*Revised June 2014 <br />302 E Santa Clara Ave <br />9/25/2024
The URL can be used to link to this page
Your browser does not support the video tag.