Laserfiche WebLink
www.hilti.com <br />Hilti PROFIS Engineering 3.0.91 <br />Input data and results must be checked for conformity with the existing conditions and for plausibility! <br />PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan <br />1 <br />Company: <br />Address: <br />Phone I Fax: <br />Design: <br />Fastening point: <br />Orie2 Engineering Inc <br />18583359452 | <br />Masonry - Jan 31, 2024 <br />Page: <br />Specifier: <br />E-Mail: <br />Date: <br />1 <br />Daniel Fisher <br />dfisher@orie2.com <br />2/1/2024 <br />Specifier's comments: <br />1 Input data <br /> Anchor type and diameter: Kwik Bolt TZ2 - SS 304 1/2 (2) <br /> Item number: 2210260 KB-TZ2 1/2x3 3/4 SS304 <br /> Effective embedment depth: hef = 2.000 in. <br /> Material: AISI 304 <br /> Evaluation Service Report: Hilti Technical Data <br /> Issued I Valid: - | - <br /> Proof: Design Method ASD Masonry <br /> Stand-off installation: <br /> Profile: <br /> Base material: Grout-filled CMU, L x W x H: 16.000 in. x 8.000 in. x 8.000 in.; <br /> Joints: vertical: 0.375 in.; horizontal: 0.375 in. <br /> Base material temperature: 68 °F <br /> Installation: Face installation <br /> Seismic loads yes <br />Geometry [in.] <br />Page 43 <br />2130 N Grand Ave <br />10/1/2024