Laserfiche WebLink
REVISION <br />REV DATE DESCRIPTION <br />A 9/11/2024 PERMIT PLANS <br />DATE: 9/11/2024 <br />DRAFTED BY: PRIYANGA <br />CHECKED BY: JOHN <br />NAME: VIETNAMESE ALLIANCE CHURCH OF ORANGE <br />PROJECT NO: 2308-02 <br />ADDRESS: 2130 N GRAND AVE, SANTA ANA, CA 92705. <br />COORDINATES: 33.764726, -117.852604 <br />APN: 396-191-44 <br />AHJ: CITY OF SANTA ANA <br />UTILITY: SCE <br />58.85kW DC (STC) SYSTEM, 55.16kW DC (PTC) VALUE, <br />50.00kW AC (NAMEPLATE) SYSTEM, 54.34 kW AC (CEC) VALUE <br />MODULES: (107) ZNSHINE SOLAR ZXM7-SHLD144-550W <br />INVERTER(S): (1) CHINT CPS SCA50KTL-DO/US-480 <br />MLPE: (56) AP SMART RSD-D-20 <br />PAGE NO: PL-1.0 <br />PROJECT INFORMATIONSYSTEM INFORMATIONCONTRACTOR INFORMATION <br />THE INFORMATION CONTAINED IN THIS DRAWING IS PROPRIETARY AND <br />CONFIDENTIAL AND SHALL ONLY BE USED FOR THE PURPOSES OF THIS <br />PROJECT. <br />ELECTRICAL <br />PLACARDS- 1 <br />SCALE: NTS <br /> WARNING <br />LABEL LOCATION <br />POINT OF INTERCONNECTION <br />(PER CODE: CEC 705.12(b)(2)(3)(b) <br />[ Not Required if Panel board is rated not less than sum of <br />ampere ratings of all overcurrent devices supplying it] <br />WARNING <br />POWER SOURCE OUTPUT <br />CONNECTION <br />DO NOT RELOCATE THIS <br />OVER-CURRENT DEVICE <br />WARNING:PHOTOVOLTAIC <br />POWER SOURCE <br />LABEL LOCATION <br />CONDUIT, COMBINER BOX <br />[PER CODE: CEC 690.31(G)(3)] <br />WARNING-ELECTRIC SHOCK HAZARD <br />NO USER SERVICEABLE PARTS INSIDE <br />CONTACT AUTHORIZED SERVICE <br />PROVIDE FOR ASSISTANCE <br />LABEL LOCATION <br />INVERTER, JUNCTION BOXES(ROOF), <br />AC DISCONNECT <br />[PER CODE: CEC 690.13] <br />LABEL LOCATION <br />DISCONNECT, POINT OF INTERCONNECTION <br />[PER CODE: CEC 690.13(B)] <br />LABEL LOCATION <br />AC DISCONNECT , POINT OF INTERCONNECTION <br />[PER CODE: CEC 690.54] <br />LABEL LOCATION <br />MARKINGS PLACED ON ALL INTERIOR AND EXTERIOR DC CONDUIT, <br />RACEWAYS, ENCLOSURES AND CABLE ASSEMBLES AT LEAST EVERY <br />10 FT, AT TURNS AND ABOVE/BELOW PENETRATIONS AND ALL <br />COMBINER/JUNCTION BOXES. <br />(PER CODE: CFC 605.11.1.4) <br />LABEL LOCATION <br />POINT OF INTERCONNECTION <br />[PER CODE: CEC 705.12(D)(4)] <br />ELECTRIC SHOCK HAZARD <br />TERMINALS ON BOTH LINE AND LOAD SIDES MAY <br />BE ENERGIZED IN THE OPEN POSITION <br />LABEL LOCATION <br />AC DISCONNECT,POINT OF INTERCONNECTION <br />[PER CODE: CEC 690.13(B)] <br />DC VOLTAGE IS ALWAYS PRESENT WHEN SOLAR <br />MODULES ARE EXPOSED TO SUNLIGHT <br />LABEL LOCATION <br />WEATHER RESISTANT MATERIAL, DURABLE ADHESDIVE, <br />UL969 AS STANDARD TO WEATHER RATING (UL LISTING <br />OF MARKINGS NOT REQUIRED), MIN 3 8" LETTER HEIGHT <br />ARIAL OR SIMILAR FONT NON-BOLD,PLACED WITHIN <br />THE MAIN SERVICE DISCONNECT,PLACED ON THE <br />OUTSIDE OF THE COVER WHEN DISCONNECT IS <br />OPERATED WITH THE SERVICE PANEL CLOSED. <br />(PER CODE: CEC 690.15,690.13(B)) <br /> WARNING <br /> DUAL POWER SOURCE SECOND <br />SOURCE IS PHOTOVOLTAIC <br />SYSTEM <br />!! <br />RATED AC OPERATING CURRENT <br />AC NOMINAL OPERATING VOLTAGE <br />60.20 <br />480 <br />AMPS AC <br />VAC <br />PHOTOVOLTAIC SYSTEM AC DISCONNECT SWITCH <br />RAPID SHUTDOWN <br />SWITCH FOR SOLAR PV <br />SYSTEM <br />LABEL LOCATION <br />INVERTER <br />[PER CODE: CEC 690.56(C)(3)] <br />A <br />60.2 <br />1000MAXIMUM SYSTEM <br />VOLTAGE(Voc) <br />MAXIMUM CIRCUIT <br />CURRENT(Isc) <br />MAXIMUM RATED OUTPUT <br />CURRENT OF THE CHARGE <br />CONTROLLER OR DC-TO-DC <br />CONVERTER(IF INSTALLED) <br />INVERTER <br />V <br />A <br />20 <br />LABEL LOCATION <br />DC DISCONNECT[PER CODE: CEC 690.53] <br />SYSTEM LABELING REQUIREMENTS: <br />LABELS MUST BE OF REFLECTIVE PHENOLIC MATERIAL WITH WHITE LETTERS AND RED <br />BACKGROUND. <br />LABELS TO BE MECHANICALLY FASTENED AND PLACED AS REQUIRED PER NEC 690. <br />LABELS TO BE IN A CAPITALIZED ARIAL FONT WITH A MINIMUM OF 3/8" IN HEIGHT. <br />DC CONDUIT LABEL MADE OF DURABLE ADHESIVE MATERIALS PLACED EVERY 10 FEET AND NEAR <br />ALL JUNCTIONS AND PENETRATIONS. <br />LABELS SHOWN FOR REFERENCE ONLY, CONTRACTOR RESPONSIBLE TO MEET LOCAL AUTHORITY <br />AND UTILITY REQUIREMENTS. <br />ELECTRICAL PLACARDS: <br /> TURN RAPID SHUTDOWN <br />SWITCH TO THE <br /> "OFF" POSITION TO <br /> SHUT DOWN PV SYSTEM <br />AND REDUCE <br />SHOCK HAZARD <br />IN THE ARRAY <br />SOLAR ELECTRIC <br />PV PANELS <br /> SOLAR PV SYSTEM EQUIPPED <br />WITH RAPID SHUTDOWN <br />LABEL LOCATION <br />AC DISCONNECT 2 OF 2 , DC DISCONNECT, <br />(PER CODE: CEC 690.56(C)(1)(A)) <br /> TURN RAPID SHUTDOWN <br />SWITCH TO THE <br /> "OFF" POSITION TO <br /> SHUT DOWN PV SYSTEM <br />AND REDUCE <br />SHOCK HAZARD <br />IN THE ARRAY <br />SOLAR ELECTRIC <br />PV PANELS <br /> SOLAR PV SYSTEM EQUIPPED <br />WITH RAPID SHUTDOWN <br />LABEL LOCATION <br />AC DISCONNECT 1 OF 2 , DC DISCONNECT,POINT OF <br />INTERCONNECTION <br />(PER CODE: CEC 690.56(C)(1)(A)) <br />4" <br />3" <br />4" <br />2" <br />6" <br />1" <br />4-3/4" <br />1-3/4" <br />4" <br />2" <br />2" <br />1" <br />6" <br />1" <br />4" <br />1" <br />6" <br />1" <br />6" <br />3-1/2" <br />4" <br />2" <br />6" <br />3-1/2" <br />4" <br />4" <br />CAUTION: SOLAR ELECTRIC <br />SYSTEM CONNECTED <br />SOLAR DISCONNECT <br />CAUTION: SOLAR CIRCUIT <br />2130 N Grand Ave <br />10/1/2024