Laserfiche WebLink
(E) FLOOR PLAN <br />SCALE: 1/4" = 1'-0" <br />NEW ADU FLOOR PLAN <br />SCALE: 1/4" = 1'-0" <br />12'-9" <br />27 <br />' <br />- <br />1 <br />" <br />5'-0" <br />25'-0" <br />10 <br />' <br />- <br />0 <br />" <br />W/D WH <br />PANTRY <br />DW <br />16 <br />' <br />- <br />4 <br />" <br />9' <br />- <br />6 <br />" <br />5' <br />- <br />6 <br />" <br />13'-0"2'-1"8'-3" <br />21 <br />' <br />- <br />0 <br />" <br />(E) BEDROOM #1 <br />(E) LIVING ROOM <br />(E) BEDROOM #2 <br />(E) BEDROOM #3 <br />(E) BEDROOM #4 <br />(E) KITCHEN <br />(E) BATH <br />(E) BATH <br />(E) GARAGE <br />(N) ADU <br />ELEC <br />PANEL <br />200 AMP <br />COND. <br />COND. <br />(E) MAIN <br />HOUSE <br />PANEL <br />UPGRADE TO <br />DUAL 400 AMP <br />METER <br />(E) GAS METER <br />(FIELD VERIFY) <br />24 <br />' <br />- <br />6 <br />" <br />19'-0" <br />17 <br />' <br />- <br />6 <br />" <br />25'-2" <br />37 <br />' <br />- <br />3 <br />" <br />19'-5"18'-11" <br />4'-8" <br />24 <br />' <br />- <br />1 <br />1 <br />" <br />7'-0" <br />5'-10" <br />(N) KITCHEN <br />(N) 9'-0" CL. HT. <br />(N) BEDROOM #1 <br />(N) 9'-0" CL. HT. <br />(N) LIVING ROOM <br />(N) 9'-0" CL. HT. <br />(N) BATH <br />(N) 9'-0" CL. HT. <br />(E) TRELLIS <br />PATIO <br />(N) 2'0"X2'0" SLD <br />OBS TEMP WD <br />(N) 4'0"X4'0" SLD WD <br />(N) 5'0"X4'0" SLD TEMP. WD <br />(N <br />) <br /> <br />4 <br />' <br />0 <br />" <br />X <br />4 <br />' <br />0 <br />" <br /> <br />S <br />L <br />D <br /> <br />W <br />D <br />(N <br />) <br /> <br />3 <br />' <br />0 <br />" <br />X <br />3 <br />' <br />0 <br />" <br /> <br />S <br />L <br />D <br /> <br />W <br />D <br />(N <br />) <br /> <br />3 <br />' <br />0 <br />" <br />X <br />6 <br />' <br />8 <br />" <br /> <br />E <br />N <br />T <br />R <br />Y <br /> <br />D <br />R <br />. <br />(N) 2'6"X6'8" <br />LOUVER DR. <br />(N) PORCH <br />(N) 9'-0" CL. HT. <br />3' <br />- <br />0 <br />" <br />10'-6" <br />30"MIN 2'-6" <br />3'-4" <br />3' <br />- <br />6 <br />" <br />(N) 3'0"X8'0" DR. <br />(N <br />) <br /> <br />3 <br />' <br />0 <br />" <br />X <br />8 <br />' <br />0 <br />" <br /> <br />D <br />R <br />. <br />R311.3.1 <br />(N) CONC. <br />LANDING <br />LA <br />N <br />D <br />I <br />N <br />G <br />2% <br /> <br />S <br />L <br />O <br />P <br />E <br />1/2" <br />(N) ESS <br />2'-0"2'-7" <br />10 <br />" <br />1 H <br />O <br />U <br />R <br /> <br />R <br />A <br />T <br />E <br />D <br /> <br />W <br />A <br />L <br />L <br /> <br />- <br /> <br />S <br />E <br />E <br /> <br />D <br />1 <br /> <br /># <br />8 <br />1 <br />H <br />O <br />U <br />R <br /> <br />R <br />A <br />T <br />E <br />D <br /> <br />W <br />A <br />L <br />L <br /> <br />- <br /> <br />S <br />E <br />E <br /> <br />D <br />E <br />T <br />A <br />I <br />L <br /> <br /># <br />8 <br />TEMP. GLASS FOR <br />DOOR/ENCLOSURE <br />FIBERGLASS OPAQUE DOOR <br />S1 <br />A <br />T.O. FLOOR <br />T.O. PLATE <br />9' <br />- <br />0 <br />" <br />T.O. F. GRADE <br />8" <br />SOUTH ELEVATION <br />SCALE: 1/4" = 1'-0" <br />14 <br />' <br />- <br />1 <br />0 <br />" <br />124.5 <br />NOTE: ALL EXTERIOR FINISH OF ADU WILL MATCH EXISTING HOUSE. <br />STUCCO,WINDOWS, DOORS, TRIMS, MULLIONS AND ROOF WILL <br />MATCH BETWEEN (E) DWELLING HOUSE AND (N) ADU. <br />NEW CLASS 'A' MIN. TILE ROOF(9.0PSF) (ESR 1900) OVER 2 <br />LAYER OF #15 FELT PER SEC. R905 INSTALLATION OF <br />ROOFING SHALL BE IN ACCORDANCE WITH MANUFACTURE'S <br />SPECIFICATIONS TYP. AND CITY OF SANTA ANA. <br />ROOF MATERIAL OF THE ADDITION WILL MATCH THE COLOR <br />AND MATERIAL OF THE EXISTING. <br />WOOD TRIM <br />(N) SIDE VENT <br />PROVIDE 2 LAYERS <br />OF GRADE D PAPER <br />OVER ALL WOOD <br />BASE SHEATHING <br />14 <br />' <br />- <br />1 <br />0 <br />" <br />EAST ELEVATION <br />SCALE: 1/4" = 1'-0" <br />T.O. FLOOR <br />T.O. PLATE <br />9' <br />- <br />0 <br />" <br />T.O. F. GRADE <br />8" <br />124.5 <br />NOTE: ALL EXTERIOR FINISH OF ADU WILL MATCH EXISTING HOUSE. <br />STUCCO,WINDOWS, DOORS, TRIMS, MULLIONS AND ROOF WILL <br />MATCH BETWEEN (E) DWELLING HOUSE AND (N) ADU. <br />NEW CLASS 'A' MIN. TILE ROOF(9.0PSF) (ESR 1900) OVER 2 <br />LAYER OF #15 FELT PER SEC. R905 INSTALLATION OF <br />ROOFING SHALL BE IN ACCORDANCE WITH MANUFACTURE'S <br />SPECIFICATIONS TYP. AND CITY OF SANTA ANA. <br />ROOF MATERIAL OF THE ADDITION WILL MATCH THE COLOR <br />AND MATERIAL OF THE EXISTING. <br />WOOD TRIM <br />PROVIDE 2 LAYERS <br />OF GRADE D PAPER <br />OVER ALL WOOD <br />BASE SHEATHING <br />NORTH ELEVATION <br />SCALE: 1/4" = 1'-0" <br />14 <br />' <br />- <br />1 <br />0 <br />" <br />T.O. FLOOR <br />T.O. PLATE <br />9' <br />- <br />0 <br />" <br />T.O. F. GRADE <br />8" <br />124.5 <br />NOTE: ALL EXTERIOR FINISH OF ADU WILL MATCH EXISTING HOUSE. <br />STUCCO,WINDOWS, DOORS, TRIMS, MULLIONS AND ROOF WILL <br />MATCH BETWEEN (E) DWELLING HOUSE AND (N) ADU. <br />NEW CLASS 'A' MIN. TILE ROOF(9.0PSF) (ESR 1900) OVER 2 <br />LAYER OF #15 FELT PER SEC. R905 INSTALLATION OF <br />ROOFING SHALL BE IN ACCORDANCE WITH MANUFACTURE'S <br />SPECIFICATIONS TYP. AND CITY OF SANTA ANA. <br />ROOF MATERIAL OF THE ADDITION WILL MATCH THE COLOR <br />AND MATERIAL OF THE EXISTING. <br />WOOD TRIM <br />WOOD BEAM <br />DECOR <br />WOOD TRIM <br />PROVIDE 2 LAYERS <br />OF GRADE D PAPER <br />OVER ALL WOOD <br />BASE SHEATHING <br />THE BUILDING SHALL HAVE <br />ADDRESS NUMBERS PLACED IN A <br />POSITION THAT IS PLAINLY LEGIBLE <br />AND VISIBLE FROM THE STREET OR <br />ROAD FRONTING THE PROPERTY. <br />NUMBERS SHALL CONTRAST WITH <br />BACKGROUND, BE ARABIC OR <br />ALPHABETICAL LETTERS AND BE A <br />MINIMUM OF 4 ” HIGH WITH A <br />MINIMUM STROKE OF ½”. (R319.1) <br />210 UNIT #2 <br />WEST ELEVATION <br />SCALE: 1/4" = 1'-0" <br />14 <br />' <br />- <br />1 <br />0 <br />" <br />T.O. FLOOR <br />T.O. PLATE <br />9' <br />- <br />0 <br />" <br />T.O. F. GRADE <br />8" <br />124.5 <br />NOTE: ALL EXTERIOR FINISH OF ADU WILL MATCH EXISTING HOUSE. <br />STUCCO,WINDOWS, DOORS, TRIMS, MULLIONS AND ROOF WILL <br />MATCH BETWEEN (E) DWELLING HOUSE AND (N) ADU. <br />NEW CLASS 'A' MIN. TILE ROOF(9.0PSF) (ESR 1900) OVER 2 <br />LAYER OF #15 FELT PER SEC. R905 INSTALLATION OF <br />ROOFING SHALL BE IN ACCORDANCE WITH MANUFACTURE'S <br />SPECIFICATIONS TYP. AND CITY OF SANTA ANA. <br />ROOF MATERIAL OF THE ADDITION WILL MATCH THE COLOR <br />AND MATERIAL OF THE EXISTING. <br />WOOD TRIM <br />PROVIDE 2 LAYERS <br />OF GRADE D PAPER <br />OVER ALL WOOD <br />BASE SHEATHING <br />LEGEND <br />EXISTING WALL <br />NEW WALL <br />NO.SIZE TYPE MATERIAL GLAZING <br />W I N D O W / D O O R S C H E D U L E <br />3'-0"X3'-0"SLIDING, W/ GRID VINYL DUAL <br />GLAZED <br />5'-0"X4'-0" <br />3'-0"X6'-8"ENTRY DOOR FIBERGLASS <br />VINYL DUAL <br />GLAZED <br />4'-0"X4'-0"SLIDING, W/ GRID VINYL DUAL <br />GLAZED <br />2'-0"X2'-0"SLIDING, OBS, TEMP, <br />W/ GRID VINYL DUAL <br />GLAZED <br />SLIDING, W/ GRID <br />2'-6"X6'-8"LOUVER DOOR METAL <br />U FACTOR = .30 SHGC = .23 <br />(N) ATTIC VENTILATION-ADU: <br />REQUIRED : 572 SF. / 150 SF. = 3.81 SF. VENT. <br />PROVIDED : 2 - 24" DORMER VENTS <br />EACH VENT = 1.57 SF X 2 = 3.14 SF. VENTILATION <br />PROVIDED : 1- 12"X24" SIDE VENT <br />EACH VENT = 2 SF X 1 = 2 SF. VENTILATION <br />TOTAL = 5.14 SF VENTILATION <br />NOTES: <br />1. AT BEDROOMS PROVIDE ONE OPENABLE ESCAPE <br />WINDOW OR DOOR MEETING ALL OF THE FOLLOWING: <br />A. AN OPENABLE AREA OF NOT LESS THAN 5.7 SQ. <br />FT. (5.0 SF. AT GRADE LEVEL) <br />B. A MINIMUM CLEAR 24 INCH HEIGHT AND 20 INCH <br />WIDTH <br />C. CLEAR OPENING NOT OVER 44 INCHES ABOVE THE <br />FLOOR. CBC 1026.2 <br />2.SHOWER COMPARTMENTS AND WALLS ABOVE <br />BATHTUB WITH SHOWER HEADS SHALL BE <br />FINISHED WITH A SMOOTH, NONABSORBENT <br />SURFACE TO A HEIGHT NOT LESS THAN 6 FEET <br />ABOVE FLOOR. (R307.2) <br />3.NONASBESTOS FIBER-CEMENT BACKER BOARDS, <br />NONASBESTOS FIBER-MAT REINFORCED <br />CEMENTITIOUS BACKER UNITS, GLASS MAT <br />GYPSUM BACKING PANELS OR FIBER-REINFORCED <br />GYPSUM PANELS SHALL BE USED AS A BACKER <br />FOR WALL TILE IN TUB AND SHOWER AREAS AND <br />WALL PANELS IN SHOWER AREAS. (R702.4.2 ) <br />3. ANTI-SCALDING SHOWER AND TUB-SHOWER <br />VALVES REQUIRED. <br />4. ALL NEW WINDOWS INCLUDING: <br /> U-FACTORS = 0.30 & SHGC = 0.23 <br />SCALE: <br />DRAWN BY: <br />DATE: <br />PLAN CHECK <br />DRAWING TITLE: <br />DATEREVISIONS: <br />HN <br />12-11-2024 <br />AS NOTED <br />00-00-0000 <br />SHEET NO. OF SHEETS <br />DATE <br />00-00-2024-------- <br />00-00-0000 <br />00-00-0000 <br />00-00-0000 <br />00-00-0000 <br />CONSULTANT: <br />21 <br />0 <br /> <br />W <br />. <br /> <br />H <br />A <br />R <br />V <br />E <br />Y <br /> <br />A <br />V <br />E <br />. <br /> <br />U <br />N <br />I <br />T <br /> <br /># <br />2 <br />( <br />A <br />D <br />U <br />) <br />, <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />7 <br />RESIDENTIAL PROJECT FOR: <br />210 W. HARVEY AVE.(ADU), <br />SANTA ANA, CA 92707 <br />DE <br />T <br />A <br />C <br />H <br />E <br />D <br /> <br />A <br />D <br />U <br /> <br />P <br />R <br />O <br />J <br />E <br />C <br />T <br />Exp. date: <br />STATE OF CALIFORNIACIVIL <br />REGISTERED PROFESS IONAL ENGINEER <br />HUE C . LUI <br />C-66754 <br />9/26 <br />1/29/2025 <br />HA NGUYEN - 1/29/2025 <br />EXISTING & <br />NEW FLOOR <br />PLAN <br />05 11 <br />A1 <br />210 W Harvey Ave <br />Unit #24/22/2025