1. PROVIDE APPROVED SMOKE ALARMS, SMOKE ALARMS <br />SHALL BE INTERCONNECTED SUCH THAT THE <br />ACTIVATION OF ONE ALARM WILL ACTIVATE ALL ALARMS. <br />2. SMOKE DETECTORS SHALL BE "HARD WIRED" AND SHALL <br />BE EQUIPPED WITH BATTERY BACK-UP @ ALL NEW <br /> BEDROOMS. <br />3.THE SMOKE ALARMS SHALL BE INTERCONNECTED. (R314.4) <br />4. FOR SINGLE-FAMILY DWELLINGS AND DUPLEXES ARE <br />NOT CHECKED FOR PLUMBING, MECHANICAL AND <br />ELECTRICAL CODE COMPLIANCE. THESE DISCIPLINES <br />ARE SUBJECT TO FIELD INSPECTION. <br />5. THE RESIDENCE SHALL CONFORM TO THE STATE <br />ENERGY STANDARDS. <br />NOTES: <br />LEGEND <br />110 v DUPLEX ELEC. OUTLET <br />WATER PROOF <br />HOSE BIBB W/ ANTI-SIPHONE <br />WALL MOUNTED LIGHT <br />CEILING MOUNTED LIGHT <br />6" LED RECESS LIGHT <br />CEILING FAN <br />SINGLE POLE SWITCH <br />SMOKE DETECTOR BATTERY (INTER-CONNECTED) <br />S <br />HB <br />GROUND FAULT INTERUPTED CIRCUIT <br />AFCI ARC FAULT CIRCUIT INTERRUPTER <br />GFI <br />EXHAUST FAN (100 CFM) W/ HUMIDITY CONTROL <br />(MAX 3 SONE) <br />DIMMER SWITCH <br />VACANCY SENSORS <br />S <br />S <br />D <br />vs <br />110 VOLT WEATHER PROOF OUTLET, GFIGFI/ <br />WP <br />SD <br />3-WAY SWITCHS3 <br />CARBON MONOXIDE DETECTORS <br />(CRC R315) SECTIONS R315.1 & R315.2 <br />CO <br />1. ALL EXISTING APPROVED SMOKE ALARMS & CARBON <br />MONOXIDE ALARM IN EACH UNITS. IF NOT PLEASE PROVIDE <br />& SHALL COMPLY WITH THE STATE ENERGY STANDARDS & <br />CITY MUNICIPAL CODE STANDARDS. <br />(FIELD VERIFY AT LOCATION) <br />2.ALL RECEPTACLE OUTLETS SHALL BE LISTED <br />TAMPER-RESISTANT RECEPTACLE PER CEC 406.12 <br />3.BATHROOM RECEPTACLES SHALL BE SERVED BY A <br />DEDICATED 20 AMP CIRCUIT PER CEC 210.52(D) <br />NOTES: <br />LEGEND <br />EXISTING WALL <br />NEW WALL <br />FOR ALTERATIONS, REPAIRS OR ADDITIONS EXCEEDING $1000, <br />EXISTING DWELLINGS OR SLEEPING UNITS THAT HAVE <br />ATTACHED GARAGES OR FUEL-BURNING APPLIANCES SHALL <br />BE PROVIDED WITH A CARBON MONOXIDE ALARM. (R315.1 CRC). <br />* ALARMS WILL BE BATTERY OPERATED. <br />* ALARMS SHALL BE LOCATED OUTSIDE EACH SEPARATE <br />SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE <br />BEDROOMS. <br />*LISTING & APPROVAL BY THE OFFICE OF THE STATE FIRE <br />MARSHAL FOR COMBINED CARBON MONOXIDE & SMOKE <br />ALARMS ARE ALLOWED. <br />1. WALLS 2 FT. OR GREATER SHALL HAVE AN OUTLET. OUTLETS <br />SHALL BE SPACED MAX. 12 FT. APART, AND A MAXIMUM OF 6 FT. <br />FROM END OF WALLS OR OPENING (CEC 210-52A) <br />2. ALL RECEPTACLE OUTLETS SHALL BE LISTED <br />TAMPER-RESISTAND RECEPTACLE PER CEC 406.11. <br />3. BATHROOM RECEPTACLES SHALL BE SERVED BY A DEDICATED <br />20 AMP CIRCUIT PER CEC 210-52(D). <br />ALL NEW CONSTRUCTION, INTERIOR OR EXTERIOR <br />ALL NEW CONSTRUCTION, INTERIOR OR EXTERIOR <br />ALTERATIONS, REPAIRS, OR ADDITIONS REQUIRING A PERMIT <br />AND HAVING A VALUATION IN EXCESS OF $1,000, AN APPROVED <br />CARBON MONOXIDE ALARM SHALL BE INSTALLED IN DWELLING <br />UNITS AND IN SLEEPING UNITS WITHIN WHICH FUEL-BURNING <br />APPLIANCES ARE INSTALLED AND IN DWELLING UNITS THAT <br />HAVE ATTACHED GARAGES SHALL BE PROVIDED WITH CARBON <br />MONOXIDE ALARMS (CRCR315) <br />- CARBON MONOXIDE ALARMS SHALL ONLY BE REQUIRED IN <br />THE SPECIFIC DWELLING UNIT OR SLEEPING UNIT FOR <br />WHICH THE PERMIT WAS OBTAINED. CARBON MONOXIDE <br />ALARMS REQUIRED BY SECTIONS R315.1 AND R315.2 SHALL <br />BE INSTALLED. REVISE DRAWINGS TO SHOW COMPLIANCE. <br />- OUTSIDE OF EACH SEPARATE DWELLING UNIT SLEEPING <br />AREA IN THE IMMEDIATE VICINITY OF THE BEDROOM(S). <br />- ON EVERY LEVEL OF A DWELLING UNIT INCLUDING <br />BASEMENTS. <br />- WHERE MORE THAN ONE CARBON MONOXIDE ALARM IS <br />REQUIRED TO BE INSTALLED WITHIN THE DWELLING UNIT <br />OR WITHIN A SLEEPING UNIT THE ALARM SHALL BE <br />INTERCONNECTED IN A MANNER THAT ACTIVATION OF ONE <br />ALARM SHALL ACTIVATE ALL OF THE ALARMS IN THE <br />INDIVIDUAL UNIT. <br />EXCEPTION: <br />INTERCONNECTION IS NOT REQUIRED IN EXISTING DWELLING <br />UNITS WHERE REPAIRS DO NOT RESULT IN THE REMOVAL OF <br />WALL AND CEILING FINISHED, THERE IS NO ACCESS BY MEANS <br />OF ATTIC, BASEMENT OR CRAWL SPACE, AND NO PREVIOUS <br />METHOD FOR INTERCONNECTION EXISTED. <br />1. PROVIDE A MINIMUM OF 2-20 AMP SMALL APPLIANCE <br />CIRCUITS FOR THE KITCHEN COUNTER TOPS. SUCH <br />CIRCUIT SHALL HAVE NO OTHER OUTLETS. LOADS SHALL BE <br />BALANCED. CEC 210-52(B)(2). <br />2. PROVIDE A MINIMUM OF 1-20 AMP LAUNDRY BRANCH <br />CIRCUIT. SUCH CIRCUIT SHALL HAVE NO OTHER OUTLETS. <br />CEC 210-23(a) <br />3.ALL INSTALLED LUMINAIRES MUST BE HIGH EFFICACY IN <br />ACCORDANCE WITH TABLE 150.0A. <br />4.EXHAUST FANS MUST BE SWITCHED SEPARATELY FROM <br />LIGHTING SYSTEMS. <br />5.IN BATHROOMS, GARAGES, LAUNDRY ROOMS, AND UTILITY <br />ROOMS, AT LEAST ONE LUMINAIRE IN EACH OF THESE <br />SPACES MUST BE CONTROLLED BY A VACANCY SENSOR. <br />1.KITCHEN RANGE HOOD (NEW CONSTRUCTION CA ENERGY <br />CODE 150.0(o)2.B.) SHALL BE FIELD VERIFIED IN <br />ACCORDANCE WITH THE PROCEDURES IN REFERENCE <br />RESIDENTIAL APPENDIX RA3.7.4.3 TO CONFIRM TO THE <br />MODEL IS RATED BY HVI TO COMPLY WITH THE FOLLOWING <br />REQUIREMENTS: <br />A.THE MINIMUM VENTILATION RATE AS SPECIFIED IN <br />SECTION 5 OF ASHRAE 62.2. <br />B.THE MAXIMUM SOUND RATING AS SPECIFIED IN <br />SECTION 7,2 OF ASHRAE 62.2. <br />2.DUCTS USED FOR DOMESTIC KITCHEN RANGE OR <br />COOKTOP VENTILATION SHALL BE OF METAL AND SHALL <br />HAVE SMOOTH INTERIOR SURFACES. (504.3) <br />EXCEPTION: DUCTS FOR DOMESTIC KITCHEN DOWNDRAFT <br />GRILL-RANGE VENTILATION INSTALLED UNDER A CONCRETE <br />SLAB FLOOR SHALL BE PERMITTED TO BE OF APPROVED <br />SCHEDULE 40 PVC PROVIDED IN COMPLIANCE WITH CMC <br />504.3. <br />3.CONDENSATE WASTE SHALL BE COLLECTED AND <br />DISCHARGED TO AN APPROVED PLUMBING FIXTURE OR <br />DISPOSAL AREA. CONDENSATE OR WASTEWATER SHALL <br />NO DRAIN OVER A PUBLIC WAY. (310.1) <br />*MECHANICAL UNIT FILTERS MUST BE MERV-13 OR BETTER. <br />(150.0(m)12C) <br />NOTES: <br />MECH. NOTES: <br />ADDITIONAL ELECTRICAL NOTES: <br />NEW CONSTRUCTION (150.0(N). WATER HEATING SYSTEMS USING GAS OR <br />PROPANE TO SERVE INDIVIDUAL DWELLING UNITS SHALL DESIGNATE A <br />SPACE AT LEAST 2.5 FEET BY 2.5 FEET WIDE AND 7 FEET TALL SUITABLE FOR <br />THE FUTURE INSTALLATION OF A HEAT PUMP WATER HEATER (HPWH) BY <br />MEETING EITHER A OR B BELOW. <br />A.A DEDICATED 125 VOLTS, 20-AMP ELECTRICAL RECEPTACLE THAT IS <br />CONNECTED TO THE ELECTRIC PANEL WITH A 120/240 VOLT 3 CONDUCTOR, <br />10 AWG COPPER BRANCH CIRCUIT, WITHIN 3 FEET FROM THE WATER <br />HEATER AND ACCESSIBLE TO THE WATER HEATER WITH NO <br />OBSTRUCTIONS; AND <br />B.BOTH ENDS OF THE UNUSED CONDUCTOR SHALL BE LABELED WITH THE <br />WORD “SPARE” AND BE ELECTRICALLY ISOLATED; AND <br />C.A RESERVED SINGLE POLE CIRCUIT BREAKER SPACE IN THE ELECTRICAL <br />PANEL ADJACENT TO THE CIRCUIT BREAKER FOR THE BRANCH CIRCUIT <br />ABOVE AND LABEL WITH THE WORDS “FUTURE 240V USE”; AND <br />D.A CONDENSATE DRAIN THAT IS NO MORE THAN 2 INCHES HIGHER THAN <br />THE BASE OF THE INSTALLED WATER HEATER, AND ALLOWS NATURAL <br />DRAINING WITHOUT PUMP ASSISTANCE. <br />ENERGY STORAGE SYSTEM (ESS) READY. AT LEAST ONE OF THE <br />FOLLOWING SHALL BE PROVIDED: <br />A.ESS READY INTERCONNECTION EQUIPMENT WITH A MINIMUM BACKED-UP <br />CAPACITY OF 60 AMPS AND A MINIMUM OF FOUR ESS-SUPPLIED BRANCH <br />CIRCUITS, OR <br />B.A DEDICATED RACEWAY FROM THE MAIN SERVICE PANEL TO A <br />PANELBOARD (SUBPANEL) THAT SUPPLIES THE FOLLOWING BRANCH <br />CIRCUITS: REFRIGERATOR, LIGHTING CIRCUIT NEAR PRIMARY EGRESS <br />DOOR, SLEEPING ROOM RECEPTACLE AND ONE ADDITIONAL. <br />THE MAIN PANELBOARD SHALL HAVE A MINIMUM BUSBAR RATING OF 225 <br />AMPS. SPACE SHALL BE RESERVED TO ALLOW FUTURE INSTALLATION OF A <br />SYSTEM ISOLATION EQUIPMENT/TRANSFER SWITCH WITHIN 3 FEET OF THE <br />MAIN PANELBOARD. RACEWAYS SHALL BE INSTALLED BETWEEN THE <br />PANELBOARD AND THE SYSTEM ISOLATION EQUIPMENT TO ALLOW THE <br />CONNECTION OF BACKUP POWER SOURCE. <br />HEAT PUMP SPACE HEATER READY. SYSTEMS USING A GAS OR PROPANE <br />FURNACE SHALL INCLUDE A DEDICATED 240-VOLT BRANCH CIRCUIT WITH 3 <br />FEET OF THE FURNACE. THE BRANCH CIRCUIT SHALL BE RATED AT 30 AMPS <br />MINIMUM. THE MAIN ELECTRICAL SERVICE SHALL HAVE A RESERVED SPACE <br />TO ALLOW FOR THE INSTALLATION OF A DOUBLE POLE CIRCUIT BREAKER. <br />THE RESERVED SPACE SHALL BE PERMANENTLY MARKED AS “FOR FUTURE <br />240V USE”. (CALIFORNIA ENERGY CODE 150.0(T)) <br />ELECTRIC COOKTOP READY. SYSTEMS USING A GAS OR PROPANE <br />COOKTOP SHALL INCLUDE A DEDICATED 240-VOLT BRANCH CIRCUIT WITH 3 <br />FEET OF THE COOKTOP. THE BRANCH CIRCUIT SHALL BE RATED AT 50 AMPS <br />MINIMUM. THE MAIN ELECTRICAL SERVICE SHALL HAVE A RESERVED SPACE <br />TO ALLOW FOR THE INSTALLATION OF A DOUBLE POLE CIRCUIT BREAKER. <br />THE RESERVED SPACE SHALL BE PERMANENTLY MARKED AS “FOR FUTURE <br />240V USE”. (CALIFORNIA ENERGY CODE 150.0(U)) <br />ELECTRICAL CLOTHES DRYER READY. SYSTEMS USING A GAS OR PROPANE <br />DRYER SHALL INCLUDE A DEDICATED 240-VOLT BRANCH CIRCUIT WITH 3 <br />FEET OF THE CLOTHES DRYER. THE BRANCH CIRCUIT SHALL BE RATED AT <br />30 AMPS MINIMUM. THE MAIN ELECTRICAL SERVICE SHALL HAVE A <br />RESERVED SPACE TO ALLOW FOR THE INSTALLATION OF A DOUBLE POLE <br />CIRCUIT BREAKER. THE RESERVED SPACE SHALL BE PERMANENTLY <br />MARKED AS “FOR FUTURE 240V USE”. (CALIFORNIA ENERGY CODE 150.0(V)) <br />1. AT BEDROOMS PROVIDE ONE OPENABLE ESCAPE <br />WINDOW OR DOOR MEETING ALL OF THE FOLLOWING: <br />A. AN OPENABLE AREA OF NOT LESS THAN 5.7 SQ. <br />FT. (5.0 SF. AT GRADE LEVEL) <br />B. A MINIMUM CLEAR 24 INCH HEIGHT AND 20 INCH <br />WIDTH <br />C. CLEAR OPENING NOT OVER 44 INCHES ABOVE THE <br />FLOOR. CBC 1026.2 <br />2. SHOWERS SHALL BE FINISHED 72" ABOVE DRAIN WITH <br />MATERIALS NOT ADVERSELY AFFECTED BY MOISTURE. <br />3. ANTI-SCALDING SHOWER AND TUB-SHOWER VALVES <br />REQUIRED. <br />4.ADDITIONS THAT EXCEED 50% OF EXISTING LIVING <br />FLOOR AREA REQUIRE UNDER GROUNDING OF ALL <br />EXISTING ABOVE GROUND UTILITIES. "PER BUILDING <br />POLICY, WHERE FEASIBLE, AND AS DETERMINED BY <br />THE BUILDING INSPECTOR, ALL ABOVE-GROUND <br />UTILITIES SHALL BE RELOCATED UNDERGROUND." <br />5.ALL NEW WINDOWS INCLUDING: <br />U-FACTORS = 0.30 & SHGC = 0.23 <br />NOTES: <br />22X30 <br />ATTIC <br />HB <br />(N)FAU 17 <br />D1 <br />16 <br />D1 <br />AFCI <br />(N) SD <br />WHOLE <br />HOUSE FAN <br />50 CFM <br />ALL SERVICES SUPPYING DWELLING UNITS SHALL <br />BE PROVIDED A SURGE PROTECTION DEVICE. THE <br />SPD SHALL BE AN INTEGRAL PART OF THE <br />SERVICE EQUIPMENT OR SHALL BE LOCATED <br />IMMEDIATELY ADJACENT THERETO. (CEC 230.667) <br />PAD SUPPORTING CONDENSER <br />SHALL BE A MINIMUM OF 3" <br />ABOVE THE GRADE. <br />HOOD OVER ELECTRIC <br />RANGE SHALL BE <br />160CFM OR 65% CE FOR <br />ELECTRICAL RANGE <br />(MAX 3 SONES) <br />PROVIDED UFER OR OTHER <br />APPROVED GROUND PER CEC 250. <br />NOTE: <br />THE MAIN PANELBOARD SHALL HAVE A <br />MINIMUM BUSBAR RATING OF 225. <br />RHEEM-HEAT PUMP <br />40 GAL <br />ELEC. HEAT PUMP <br />PROVIDE BLOCKING FOR <br />FUTURE ADA GRAB BAR <br />ELECTRICAL PLAN <br />SCALE: 1/4" = 1'-0" <br />12'-9" <br />27 <br />' <br />- <br />1 <br />" <br />25'-0" <br />10 <br />' <br />- <br />0 <br />" <br />W/D WH <br />PANTRY <br />DW <br />16 <br />' <br />- <br />4 <br />" <br />9' <br />- <br />6 <br />" <br />5' <br />- <br />6 <br />" <br />13'-0"2'-1"8'-3" <br />21' <br />- <br />0 <br />" <br />(N) ADU <br />ELEC <br />PANEL <br />200 AMP <br />COND. <br />(N) KITCHEN <br />(N) 9'-0" CL. HT. <br />(N) BEDROOM #1 <br />(N) 9'-0" CL. HT. <br />(N) LIVING ROOM <br />(N) 9'-0" CL. HT. <br />(N) BATH <br />(N) 9'-0" CL. HT. <br />(N) 2'0"X2'0" SLD <br />OBS TEMP WD <br />(N) 4'0"X4'0" SLD WD <br />(N) 5'0"X4'0" SLD TEMP. WD <br />(N <br />) <br /> <br />4 <br />' <br />0 <br />" <br />X <br />4 <br />' <br />0 <br />" <br /> <br />S <br />L <br />D <br /> <br />W <br />D <br />(N <br />) <br /> <br />3 <br />' <br />0 <br />" <br />X <br />3 <br />' <br />0 <br />" <br /> <br />S <br />L <br />D <br /> <br />W <br />D <br />(N <br />) <br /> <br />3 <br />' <br />0 <br />" <br />X <br />6 <br />' <br />8 <br />" <br /> <br />E <br />N <br />T <br />R <br />Y <br /> <br />D <br />R <br />. <br />(N) 2'6"X6'8" <br />LOUVER DR. <br />(N) PORCH <br />(N) 9'-0" CL. HT. <br />3' <br />- <br />0 <br />" <br />10'-6" <br />ESS READY <br />SEE DIAGRAM <br />AFCI <br />AFCIAFCI <br />AFCI <br />AFCI <br />AFCI <br />AFCIAFCI <br />S <br />GFCI <br />SS <br />VS <br />GFCI <br />TYPE 1 CLOTHES DRYER EXHAUST DUCT <br />(MIN. 4 INCH DIA. AND 0.16" THICK RIGID <br />METAL TO OUTSIDE OF THE BUILDING <br />AND EQUIPPED WITH A BACK-DRAFT <br />DAMPER. EXHAUST DUCT LENGTH IS <br />LIMITED TO 14 FT. WITH 2 ELBOWS. <br />(N) SD+CO <br />PHOTOELEC. <br />HB <br />AFCI <br />GFCI <br />AFCI <br />GFCI <br />AFCI <br />GFCI <br />AFCI <br />GFCI <br />AFCI <br />GFCI <br />AFCI <br />GFCI <br />AFCI <br />(N) LED <br />PHOTO <br />CONTROL & <br />MOTION <br />SENSOR <br />(N) LED <br />PHOTO <br />CONTROL & <br />MOTION <br />SENSOR <br />D <br />S <br />SS <br />SS <br />S <br />S <br />DD <br />3 3 <br />AFCI <br />S <br />(N) LED <br />PHOTO <br />CONTROL & <br />MOTION <br />SENSOR <br />(N) LED <br />PHOTO <br />CONTROL & <br />MOTION <br />SENSOR <br />(N) LED <br />PHOTO <br />CONTROL & <br />MOTION <br />SENSOR <br />(N) LED <br />PHOTO <br />CONTROL & <br />MOTION <br />SENSOR <br />PROVIDE NOTE: "EFFECTIVE JANUARY 1, 2014, SENATE <br />BILL 407 REQUIRES A BUILDING PERMIT APPLICANT TO <br />REPLACE ALL NONCOMPLIANT PLUMBING FIXTURES IN <br />PROPERTIES BUILT AND AVAILABLE FOR USE ON OR <br />BEFORE JANUARY 1, 1994 WITH WATER-CONSERVING <br />PLUMBING FIXTURES AS A CONDITION FOR APPROVAL <br />OF A FINAL BUILDING PERMIT FOR BUILDING <br />ALTERATIONS OR IMPROVEMENTS. CONTRACTOR <br />SHALL COMPLETE SB 407 AFFIDAVIT FORM AND <br />SUBMIT TO THE INSPECTOR PRIOR TO FINAL <br />INSPECTION. NON COMPLIANT PLUMBING FIXTURES <br />MEANS ANY OF THE FOLLOWIN <br />1.ANY TOILET MANUFACTURED TO USE MORE <br />THAN 1.28 GALLONS OF WATER PER FLUSH <br />2.ANY URINAL MANUFACTURED TO USE MORE <br />THAN ONE GALLON OF WATER PER FLUSH <br />3. ANY SHOWERHEAD MANUFACTURED TO HAVE A <br />FLOW CAPACITY OF MORE THAN 1.8 GPM <br />4.ANY INTERIOR FAUCET THAT EMITS MORE THAN <br />2.0 GPM. <br />1.THE WHOLE-BUILDING VENTILATION EXHAUST FAN WILL OPERATE <br />CONTINUOUSLY AND IS REQUIRED TO BE RATED FOR SOUND AT A <br />MAXIMUM OF 1 SONE. THIS EXHAUST FAN CAN BE CONTROLLED BY <br />A STANDARD ON/OFF SWITCH BUT THE SWITCH MUST BE LABELED <br />CLEARLY DISPLAYING THE FOLLOWING TEXT, OR EQUIVALENT. "THIS <br />SWITCH CONTROLS THE INDOOR AIR QUALITY VENTILATION FOR <br />THE HOUSE. LEAVE SWITCH IN THE "ON" POSITION AT ALL TIMES <br />UNLESS THE OUTDOORAIR QUALITY IS VERY POOR." [150.0(o)J] <br />WHOLE HOUSE FAN INFO: <br />MANUF. = PANASONIC <br />MODEL # = RG-R811LA <br />1 SONE RATING <br />WHOLE HOUSE FAN NOTES: <br />AGING-IN-PLACE/FALL PREVENTION NOTES: <br />A.REINFORCEMENT FOR GRAB BARS. [R327.1.1] <br />AT LEAST ONE BATHROOM ON THE ENTRY LEVEL SHALL BE <br />PROVIDED WITH REINFORCEMENT INSTALLED IN ACCORDANCE <br />WITH THIS SECTION. WHERE THERE IS NO BATHROOM ON THE <br />ENTRY LEVEL, AT LEAST ONE BATHROOM ON THE 2ND OR 3RD <br />FLOOR OF THE DWELLING SHALL COMPLY WITH THIS SECTION. <br />1.REINFORCEMENT SHALL BE SOLID LUMBER OR OTHER <br />CONSTRUCTION MATERIALS APPROVED BY THE ENFORCING <br />AGENCY. <br />2.REINFORCEMENT SHALL NOT BE LESS THAN 2 BY 8 INCH NOMINAL <br />LUMBER (1-1/2” X 7-1/4” ACTUAL DIMENSION) OR OTHER <br />CONSTRUCTION MATERIAL PROVIDING EQUAL HEIGHT AND LOAD <br />CAPACITY. REINFORCEMENT SHALL BE LOCATED BETWEEN 32” AND <br />39-1/4” ABOVE THE FINISHED FLOOR, FLUSH WITH THE WALL <br />FRAMING. <br />3.WATER CLOSET REINFORCEMENT SHALL BE INSTALLED ON BOTH <br />SIDE WALLS OF THE FIXTURE, OR ONE SIDE WALL AND THE BACK <br />WALL. <br />4.SHOWER REINFORCEMENT SHALL BE CONTINUOUS WHERE WALL <br />FRAMING IS PROVIDED. <br />5.BATHTUB AND COMBINATION BATHTUB/SHOWER <br />REINFORCEMENT SHALL BE CONTINUOUS ON EACH END OF THE <br />BATHTUB AND THE BACK WALL. ADDITIONALLY, BACK WALL <br />REINFORCEMENT FOR A LOWER GRAB BAR SHALL BE PROVIDED <br />WITH THE BOTTOM EDGE LOCATED NO MORE THAN 6” ABOVE THE <br />BATHTUB RIM. <br />6.WHERE THE WATER CLOSET IS NOT PLACED ADJACENT TO A SIDE <br />WALL CAPABLE OF ACCOMMODATING A GRAB BAR, THE BATHROOM <br />SHALL HAVE PROVISIONS FOR INSTALLATION OF FLOOR-MOUNTED, <br />FOLDAWAY OR SIMILAR ALTERNATE GRAB BAR REINFORCEMENTS <br />APPROVED BY THE ENFORCING AGENCY. <br />B.DOCUMENTATION FOR GRAB BAR REINFORCEMENT. [R327.1.1.1] <br />INFORMATION AND/OR DRAWINGS IDENTIFYING THE LOCATION OF <br />GRAB BAR REINFORCEMENT SHALL BE PLACED IN THE OPERATION & <br />MAINTENANCE MANUAL IN ACCORDANCE WITH THE CALIFORNIA <br />GREEN BUILDING STANDARDS CODE, CH. 4, DIVISION 4.4. <br />C.DOORBELL BUTTONS. [R327.1.4] <br />DOORBELL BUTTONS OR CONTROLS, WHEN INSTALLED, SHALL NOT <br />EXCEED 48” ABOVE EXTERIOR FLOOR OR LANDING, MEASURED <br />FROM THE TOP OF THE DOORBELL BUTTON ASSEMBLY. WHERE <br />DOORBELL BUTTONS INTEGRATED WITH OTHER FEATURES ARE <br />REQUIRED TO BE INSTALLED ABOVE 48” MEASURED FROM THE <br />EXTERIOR FLOOR OR LANDING, A STANDARD DOORBELL BUTTON OR <br />CONTROL SHALL ALSO BE PROVIDED AT A HEIGHT NOT EXCEEDING <br />48” ABOVE EXTERIOR FLOOR OR LANDING, MEASURED FROM THE <br />TOP OF THE DOORBELL BUTTON OR CONTROL. <br />ALL BRANCH CIRCUITS THAT SUPPLY 125 VOLT, SINGLE <br />PHASE, 15 AND 20 AMPERE OUTLETS INSTALLED IN <br />DWELLING UNITS SHALL BE PROTECTED BY AN ARC-FAULT <br />CIRCUIT INTERRUPTER(S). [CEC 210.12] NOTE THIS <br />REQUIREMENT IS FOR ENTIRE CIRCUIT, NOT JUST THE OUTLETS. <br />NOTES: <br />1)PROVIDE SMOKE ALARM IN EACH BEDROOM OR <br />SLEEPING AREA, AND OUTSIDE OF EACH SEPARATE <br />BEDROOM/SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE <br />BEDROOM/SLEEPING AREA. LOCATION OF SMOKE DETECTORS <br />SHALL COMPLY WITH CRC SECTION R314.3.3. HARDWIRED AND <br />INTERCONNECTED SMOKE ALARMS ARE REQUIRED. (CRC R314) <br />2)PROVIDE CARBON MONOXIDE ALARM OUTSIDE OF EACH <br />SEPARATE BEDROOM/SLEEPING AREA IN THE IMMEDIATE <br />VICINITY OF THE BEDROOM/SLEEPING AREA. HARDWIRED AND <br />INTERCONNECTED CARBON MONOXIDE ALARMS Are Required. <br />(CRC R315) <br />3)SMOKE ALARMS SHALL BE AT LEAST 3 ' FROM A SUPPLY <br />REGISTER OR A BATHROOM DOOR/OPENING. <br />4)SMOKE ALARMS SHALL BE AT LEAST 20 ' FROM COOKING <br />APPLIANCE (10' FOR IONIZATION ALARM WITH SILENCING <br />SWITCH OR PHOTOELECTRIC ALARM). <br />NOTES:ELECTRICAL RECEPTACLE OUTLETS, SWITCHES AND CONTROLS <br />SHALL BE LOCATED NO MORE THAN 48” MEASURED TO TOP OF <br />THE OUTLET BOX AND NOT LESS THAN 15” MEASURED FROM <br />BOTTOM OF THE OUTLET BOX ABOVE THE FINISH FLOOR. <br />NOTES: <br />SCALE: <br />DRAWN BY: <br />DATE: <br />PLAN CHECK <br />DRAWING TITLE: <br />DATEREVISIONS: <br />HN <br />12-11-2024 <br />AS NOTED <br />00-00-0000 <br />SHEET NO. OF SHEETS <br />DATE <br />00-00-2024-------- <br />00-00-0000 <br />00-00-0000 <br />00-00-0000 <br />00-00-0000 <br />CONSULTANT: <br />21 <br />0 <br /> <br />W <br />. <br /> <br />H <br />A <br />R <br />V <br />E <br />Y <br /> <br />A <br />V <br />E <br />. <br /> <br />U <br />N <br />I <br />T <br /> <br /># <br />2 <br />( <br />A <br />D <br />U <br />) <br />, <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />7 <br />RESIDENTIAL PROJECT FOR: <br />210 W. HARVEY AVE.(ADU), <br />SANTA ANA, CA 92707 <br />DE <br />T <br />A <br />C <br />H <br />E <br />D <br /> <br />A <br />D <br />U <br /> <br />P <br />R <br />O <br />J <br />E <br />C <br />T <br />Exp. date: <br />STATE OF CALIFORNIACIVIL <br />REGISTERED PROFESS IONAL ENGINEER <br />HUE C . LUI <br />C-66754 <br />9/26 <br />1/29/2025 <br />HA NGUYEN - 1/29/2025 <br />ELECTRICAL <br />PLAN <br />06 11 <br />A2 <br />210 W Harvey Ave <br />Unit #24/22/2025