CODE REQUIRED SIGNAGE <br />SIGNAGE NOTES: <br />1. ARTICLES 690 AND 705 MARKINGS SHOWN HEREON <br />2. ALL MARKINGS SHALL CONSIST OF THE FOLLOWING: <br />A. UV RESISTANT SIGN MATERIAL WITH ENGRAVED OR MACHINE PRINTED LETTERS OR ELECTRO-PLATING <br />B. RED BACKGROUND COLOR WITH WHITE TEXT AND LINE WORK UON <br />C. ARIAL FONT <br />3. ALL SIGNS SHALL BE SIZED APPROPRIATELY AND PLACED IN THE LOCATIONS SPECIFIED. <br />4. SIGNS SHALL BE ATTACHED TO THE SERVICE EQUIPMENT USING PERMANENT ADHESIVE. <br />CONDUIT RACEWAYS <br />PHOTOVOLTAIC POWER SOURCE <br />CODE: PER NEC 690.31(D)(2) <br />JUNCTION BOX <br />WARNING <br />TURN OFF PHOTOVOLTAIC <br />AC DISCONNECT PRIOR TO <br />WORKING INSIDE PANEL <br />CODE: PER NEC 110.27(C) <br />& OSHA 1910.145(F)(7) <br />AC DISCONNECT <br />MAIN SERVICE PANEL <br />WARNING <br />ELECTRICAL SHOCK HAZARD <br />TERMINALS ON THE LINE AND <br />LOAD SIDES MAY BE ENERGIZED <br />IN THE OPEN POSITION <br />CODE: PER NEC 706.15(C)(4) <br />NEC 690.13(B) <br />MAIN SERVICE PANEL <br />WARNING <br />TURN OFF PHOTOVOLTAIC <br />AC DISCONNECT PRIOR TO <br />WORKING INSIDE PANEL <br />CODE: PER NEC 110.27(C) <br />& OSHA 1910.145(F)(7) <br />MAIN SERVICE PANEL <br />PERFORMANCE METER <br />WARNING DUAL POWER SOURCE <br />SECOND SOURCE IS PHOTOVOLTAIC SYSTEM <br />CODE: PER NEC 690.59 & NEC 705.12(D)(3) <br />MAIN SERVICE PANEL <br />AC DISCONNECT <br />RAPID SHUTDOWN FOR <br />SOLAR PV SYSTEM <br />MAIN SERVICE PANEL <br />CODE: PER NEC 690.56(C)(2) <br />DO NOT DISCONNECT <br />UNDER LOAD <br />CODE: PER NEC 690.15(B) & <br />NEC 690.33(D)(2) <br />SOLAR DISCONNECT <br />ON PV AC DISCONNECT <br />AC DISCONNECT <br />PHOTOVOLTAIC AC DISCONNECT <br />RATED AC OUTPUT CURRENT <br />NOMINAL OPERATING AC VOLTAGE 480V <br />238.5A <br />CODE: PER NEC 690.54 <br />AC DISCONNECT <br />PHOTOVOLTAIC <br />AC DISCONNECT <br />CODE: PER NEC 690.13(B) <br />MAIN SERVICE PANEL <br />SOLAR PV SYSTEM EQUIPPED <br />WITH RAPID SHUTDOWN <br />TURN RAPID SHUTDOWN <br />SWITCH TO THE <br />"OFF"POSITION TO <br />SHUT DOWN PV SYSTEM <br />AND REDUCE <br />SHOCK HAZARD <br />IN THE ARRAY <br />CODE: PER NEC 605.11.3.1(1) <br />& NEC 690.56(C) <br />MAIN SERVICE PANEL <br />NEXT TO PV BREAKER <br />WARNING <br />POWER SOURCE OUTPUT <br />CONNECTION. DO NOT <br />RELOCATE THIS <br />OVERCURRENT DEVICE. <br />CODE: PER NEC 705.12 (B)(3)(2) <br />SOLAR ELECTRIC <br />PV PANELS <br />JUNCTION BOX <br />WARNING <br />ELECTRICAL SHOCK HAZARD <br />TERMINALS ON THE LINE AND <br />LOAD SIDES MAY BE ENERGIZED <br />IN THE OPEN POSITION <br />CODE: PER NEC 706.15(C)(4) <br />NEC 690.13(B) <br />DC CONDUIT RACEWAYS <br />SOLAR PV DC CIRCUIT <br />CODE: PER NEC 690.31(D)(2) <br />CONDUIT, CABLES, <br />PULL BOXES,J-BOX <br />WARNING <br />RACEWAY IS ENERGIZED WHEN <br />IN THE OPEN POSITION. DO NOT <br />RELOCATE OR CUT <br />JUNCTION BOX <br />SOLAR INVERTER/DC DISCO. <br />MAXIMUM DC VOLTAGE <br />OF PV SYSTEM <br />956.75 <br />CODE: PER NEC 690.53 <br />INVERTER / DC DISCONNECT <br />PHOTOVOLTAIC <br />DC DISCONNECT <br />CODE: PER NEC 690.13(B) <br />DESIGNER <br />DATE <br />AHJ <br />UTILITY <br />MOUNTING SYSTEM <br />MODULE SCALE <br />DESCRIPTION <br />CITY OF SANTA ANA <br />SCE <br />SOLLEGA RACKING SYSTEM <br />(388) HANWHA Q.PEAK 490W (Q.PEAK DUO XL-G10.3/BFG 490) <br />190.12 KW (DC) PHOTOVOLTAIC SYSTEM <br />173.69 KW (CEC-AC) PHOTOVOLTAIC SYSTEM <br />RAHUL DISA <br />AS INDICATED <br />03-08-2024 <br />28476 WESTINGHOUSE PLACE, VALENCIA, CA 91355 <br />PHONE: (661) 294-9495 <br />CA LICENSE: #927678 (B, C-10, & C-39) <br />INVERTER <br />MARK FIGEARO <br />(3) STP CORE1-62-US (STP-62-US-41) (480V) STRING INVERTER <br />PAGE NO.PAGE NAME <br />LABELS E3 <br />PROJECT ADDRESS <br />FREUDENBERG - NOK <br />2041 E WILSHIRE AVENUE <br />SANTA ANA, CA 92705 <br />2041 E Wilshire Ave- <br />101118991 & 201825946/3/2024