My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2024 S Garnsey St & Unit #2 - Plan
PBA
>
Building
>
ProjectDox
>
G
>
Garnsey St
>
2024 S Garnsey St Unit# 2
>
2024 S Garnsey St & Unit #2 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/5/2025 7:34:30 AM
Creation date
6/5/2025 7:34:18 AM
Metadata
Fields
Template:
Plan
Permit Number
101121258
Full Address
2024 S Garnsey St Unit# 2
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
38
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
1226 W. NINTH ST. <br />UPLAND, CA 91786 <br />310.487.1613 <br />HELLO@DREAMDESIGN.BUILD <br />DREAMDESIGN.BUILD <br />OWNER: <br />RAFAEL LUZ <br />ADDRESS: <br />MAIN DWELLING: <br />2024 S GARNSEY ST <br />SANTA ANA , CA 92707 <br />NEW ADU: <br />2024 S GARNSET ST UNIT #2 <br />SANTA ANA, CA 92707 <br />SCOPE OF WORK: <br />A. NEW DETACHED ADU W/ AWNING <br />529 SQ. FT. <br />NEW ADDRESS: 2024 S. GARNSEY ST <br />UNIT #2 <br />(1 BEDROOM / 1 BATHROOM) <br />SFD ADDRESS: 2024 S. GARNSEY ST <br />B. DEMO OF UNPERMITTED PATIO <br />COVER <br />C. REMOVAL OF UNPERMITTED SHEDS <br />D. RELOCATION OF SFD LAUNDRY <br />E. REMOVAL OF WINDOW AC UNITS <br />F. UPGRADE ELETRICAL PANEL <br />PLANS PREPARED BY: <br />RESTRICTIVE NOTICE: <br />ALL DESIGNS, IDEAS, DETAILS, PLANS & <br />SPECIFICATIONS INDICATED BY THE DRAWINGS ARE <br />THE EXCLUSIVE PROPERTY OF DDB,LLC. THE PLANS <br />WERE CREATED AND DEVELOPED FOR USE ON AND <br />IN CONJUNCTION WITH THE SPECIFIC PROJECT <br />DESCRIBED HEREIN. NO PART THEREOF SHALL BE <br />REPRODUCED, COPIED, ADAPTED, MODIFIED OR <br />DISTRIBUTED TO OTHERS WITHOUT PRIOR WRITTEN <br />AND SPECIFIC CONSENT FROM DDB, LLC. <br />TITLE 24 <br />T1.1 <br />SCALE: <br />DRAWN: <br />CHECKED: <br />DATE: <br />REVISION: <br />REVISION: <br />EDGAR VIDAL <br />2/4/2025 <br />AS SHOWN <br />E. VIDAL <br />CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E <br />Project Name:Residential Building Calculation Date/Time:2024-12-16T21:48:11-08:00 (Page 1 of 11) <br />Calculation Description:Title 24 Analysis Input File Name:2024 S Garsney St - ADU 7.7.23.ribd22x <br />Registration Number:Registration Date/Time: HERS Provider: <br />CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 <br />Schema Version: rev 20220901 <br />Report Generated: 2024-12-16 21:48:42 <br />GENERAL INFORMATION <br />01 Project Name Residential Building <br />02 Run Title Title 24 Analysis <br />03 Project Location 2024 S Garsney St #2 <br />04 City Santa Ana 05 Standards Version 2022 <br />06 Zip code 92707 07 Software Version EnergyPro 9.2 <br />08 Climate Zone 8 09 Front Orientation (deg/ Cardinal)90 <br />10 Building Type Single family 11 Number of Dwelling Units 1 <br />12 Project Scope Newly Constructed Addition 13 Number of Bedrooms 1 <br />14 Addition Cond. Floor Area (ft2)529 15 Number of Stories 1 <br />16 Existing Cond. Floor Area (ft2)0.01 17 Fenestration Average U-factor 0.3 <br />18 Total Cond. Floor Area (ft2)529.01 19 Glazing Percentage (%)13.42% <br />20 ADU Bedroom Count 1 21 ADU Conditioned Floor Area 529 <br />22 Fuel Type Natural gas 23 No Dwelling Unit:No <br />ADDITION ALONE - Project Analysis Parameters <br />01 02 03 04 05 06 <br />Existing Area (excl. new addition) <br />(ft2) <br />Addition Area (excl. existing) <br />(ft2)Total Area (ft2)Existing Bedrooms Addition Bedrooms Total Bedrooms <br />0.01 529 529.01 0 1 1 <br />ADDITION ALONE - ACCESSORY DWELLING UNIT (ADU) PROJECT ANALYSIS PARAMETERS <br />01 02 03 04 05 06 07 08 <br />Zone Name Existing Area (excl. <br />new addition) (ft2) <br />ADU Area (excl. <br />existing) (ft2)Total Area (ft2)Existing Bedrooms Addition Bedrooms Total Bedrooms Attached vs. Detached <br />Zone 1 0.01 529 529.01 0 1 1 Detached <br />424-P010316925A-000-000-0000000-0000 12/16/2024 21:50 CHEERS <br />NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, <br />and cannot guarantee, the accuracy or completeness of the information contained in this document. <br />CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E <br />Project Name:Residential Building Calculation Date/Time:2024-12-16T21:48:11-08:00 (Page 2 of 11) <br />Calculation Description:Title 24 Analysis Input File Name:2024 S Garsney St - ADU 7.7.23.ribd22x <br />Registration Number:Registration Date/Time: HERS Provider: <br />CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 <br />Schema Version: rev 20220901 <br />Report Generated: 2024-12-16 21:48:42 <br />COMPLIANCE RESULTS <br />01 Building Complies with Computer Performance <br />02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider. <br />03 This building incorporates one or more Special Features shown below <br />424-P010316925A-000-000-0000000-0000 12/16/2024 21:50 CHEERS <br />NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, <br />and cannot guarantee, the accuracy or completeness of the information contained in this document. <br />CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E <br />Project Name:Residential Building Calculation Date/Time:2024-12-16T21:48:11-08:00 (Page 3 of 11) <br />Calculation Description:Title 24 Analysis Input File Name:2024 S Garsney St - ADU 7.7.23.ribd22x <br />Registration Number:Registration Date/Time: HERS Provider: <br />CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 <br />Schema Version: rev 20220901 <br />Report Generated: 2024-12-16 21:48:42 <br />ENERGY USE SUMMARY <br />Energy Use Standard Design Source <br />Energy (EDR1) (kBtu/ft2 -yr) <br />Standard Design TDV Energy <br />(EDR2) (kTDV/ft2 -yr) <br />Proposed Design Source <br />Energy (EDR1) (kBtu/ft2 -yr) <br />Proposed Design TDV Energy <br />(EDR2) (kTDV/ft2 -yr) <br />Compliance <br />Margin (EDR1) <br />Compliance <br />Margin (EDR2) <br />Space Heating 0 0.39 0 0.32 0 0.07 <br />Space Cooling 0 45.55 0 32.19 0 13.36 <br />IAQ Ventilation 0 4.76 0 4.76 0 0 <br />Water Heating 0 51.21 0 50.83 0 0.38 <br />Self <br />Utilization/Flexibility <br />Credit <br />Efficiency Compliance <br />Total 0 101.91 0 88.1 0 13.81 <br />Photovoltaics 0 0 <br />Battery 0 <br />Flexibility <br />Indoor Lighting 0 10.64 0 10.64 <br />Appl. & Cooking 0 57.93 0 57.93 <br />Plug Loads 0 69.51 0 69.51 <br />Outdoor Lighting 0 1.95 0 1.95 <br />TOTAL COMPLIANCE 0 241.94 0 228.13 <br />424-P010316925A-000-000-0000000-0000 12/16/2024 21:50 CHEERS <br />NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, <br />and cannot guarantee, the accuracy or completeness of the information contained in this document. <br />CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E <br />Project Name:Residential Building Calculation Date/Time:2024-12-16T21:48:11-08:00 (Page 4 of 11) <br />Calculation Description:Title 24 Analysis Input File Name:2024 S Garsney St - ADU 7.7.23.ribd22x <br />Registration Number:Registration Date/Time: HERS Provider: <br />CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 <br />Schema Version: rev 20220901 <br />Report Generated: 2024-12-16 21:48:42 <br />ENERGY USE INTENSITY <br />Standard Design (kBtu/ft2 - yr )Proposed Design (kBtu/ft2 - yr )Compliance Margin (kBtu/ft2 - yr )Margin Percentage <br />Gross EUI1 39.21 37.97 1.24 3.16 <br />Net EUI2 39.21 37.97 1.24 3.16 <br />Notes <br /> 1. Gross EUI is Energy Use Total (not including PV) / Total Building Area. <br /> 2. Net EUI is Energy Use Total (including PV) / Total Building Area. <br />REQUIRED SPECIAL FEATURES <br />The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. <br />•Insulation below roof deck <br />HERS FEATURE SUMMARY <br />The following is a summary of the features that must be field-verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional <br />detail is provided in the building tables below. Registered CF2Rs and CF3Rs are required to be completed in the HERS Registry <br />•Quality insulation installation (QII) <br />•Indoor air quality ventilation <br />•Kitchen range hood <br />•Whole house fan airflow and fan efficacy <br />•Minimum Airflow <br />•Verified EER/EER2 <br />•Verified SEER/SEER2 <br />•Verified Refrigerant Charge <br />•Fan Efficacy Watts/CFM <br />•Verified HSPF <br />•Verified heat pump rated heating capacity <br />•Duct leakage testing <br />•Pipe Insulation, All Lines <br />424-P010316925A-000-000-0000000-0000 12/16/2024 21:50 CHEERS <br />NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, <br />and cannot guarantee, the accuracy or completeness of the information contained in this document. <br />CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E <br />Project Name:Residential Building Calculation Date/Time:2024-12-16T21:48:11-08:00 (Page 5 of 11) <br />Calculation Description:Title 24 Analysis Input File Name:2024 S Garsney St - ADU 7.7.23.ribd22x <br />Registration Number:Registration Date/Time: HERS Provider: <br />CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 <br />Schema Version: rev 20220901 <br />Report Generated: 2024-12-16 21:48:42 <br />ZONE INFORMATION <br />01 02 03 04 05 06 07 <br />Zone Name Zone Type HVAC System Name Zone Floor Area (ft2)Avg. Ceiling Height Water Heating System 1 Status <br />Zone 1 Conditioned HVAC System1 529 8 DHW Sys 1 New <br />OPAQUE SURFACES <br />01 02 03 04 05 06 07 08 09 10 <br />Name Zone Construction Azimuth Orientation Gross Area (ft2)Window and Door <br />Area (ft2)Tilt (deg)Wall Exceptions Status <br />North 1 Exterior <br />Wall Zone 1 R-15 Wall 0 Right 148 16 90 Extension New <br />East Exterior Wall Zone 1 R-15 Wall 90 Front 167.2 37 90 Extension New <br />West Exterior Wall Zone 1 R-15 Wall 270 Back 260 13 90 Extension New <br />South Exterior <br />Wall Zone 1 R-15 Wall 180 Left 148 10 90 Extension New <br />North 2 Exterior <br />Wall Zone 1 R-15 Wall 0 Right 20 0 90 Extension New <br />East 2 Exterior <br />Wall Zone 1 R-15 Wall 180 Left 95.2 16 90 Extension New <br />Roof Zone 1 R-38 HP Attic n/a n/a 529 n/a n/a New <br />ATTIC <br />01 02 03 04 05 06 07 08 <br />Name Construction Type Roof Rise (x in 12)Roof Reflectance Roof Emittance Radiant Barrier Cool Roof <br />Attic Zone 1 Attic RoofZone 1 Ventilated 4 0.1 0.85 No No <br />424-P010316925A-000-000-0000000-0000 12/16/2024 21:50 CHEERS <br />NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, <br />and cannot guarantee, the accuracy or completeness of the information contained in this document. <br />CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E <br />Project Name:Residential Building Calculation Date/Time:2024-12-16T21:48:11-08:00 (Page 6 of 11) <br />Calculation Description:Title 24 Analysis Input File Name:2024 S Garsney St - ADU 7.7.23.ribd22x <br />Registration Number:Registration Date/Time: HERS Provider: <br />CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 <br />Schema Version: rev 20220901 <br />Report Generated: 2024-12-16 21:48:42 <br />FENESTRATION / GLAZING <br />01 02 03 04 05 06 07 08 09 10 11 12 13 14 <br />Name Type Surface Orientation Azimuth Width <br />(ft) <br />Height <br />(ft)Mult.Area <br />(ft2)U-factor U-factor <br />Source SHGC SHGC Source Exterior Shading <br />Window Window North 1 <br />Exterior Wall Right 0 1 16 0.3 NFRC 0.23 NFRC Bug Screen <br />Window 2 Window East Exterior <br />Wall Front 90 1 16 0.3 NFRC 0.23 NFRC Bug Screen <br />Window 3 Window West Exterior <br />Wall Back 270 1 13 0.3 NFRC 0.23 NFRC Bug Screen <br />Window 4 Window South Exterior <br />Wall Left 180 1 10 0.3 NFRC 0.23 NFRC Bug Screen <br />Window 5 Window East 2 Exterior <br />Wall Left 180 1 16 0.3 NFRC 0.23 NFRC Bug Screen <br />OPAQUE DOORS <br />01 02 03 04 <br />Name Side of Building Area (ft2)U-factor <br />Door East Exterior Wall 21 0.2 <br />SLAB FLOORS <br />01 02 03 04 05 06 07 08 <br />Name Zone Area (ft2)Perimeter (ft)Edge Insul. R-value <br />and Depth <br />Edge Insul. R-value <br />and Depth Carpeted Fraction Heated <br />Slab-on-Grade Zone 1 529 0.1 none 0 100%No <br />424-P010316925A-000-000-0000000-0000 12/16/2024 21:50 CHEERS <br />NOTICE: This document has been generated by California Home Energy Efficiency Rating Services (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, <br />and cannot guarantee, the accuracy or completeness of the information contained in this document. <br />2024 S Garnsey St & Unit <br />#24/18/2025
The URL can be used to link to this page
Your browser does not support the video tag.