Laserfiche WebLink
SCALE: <br />N <br />2PROPOSED FLOOR PLAN 1/4" = 1'-0" <br />9/ <br />2 <br />3 <br />/ <br />2 <br />0 <br />2 <br />4 <br /> <br />1 <br />: <br />0 <br />4 <br /> <br />P <br />M <br />MO <br />O <br />N <br />S <br />H <br />O <br />T <br />CO <br />N <br />S <br />U <br />L <br />T <br />A <br />N <br />C <br />Y <br />.c <br />o <br />m <br />PR <br />E <br />M <br />I <br />U <br />M <br /> <br />D <br />E <br />S <br />I <br />G <br />N <br /> <br />S <br />E <br />R <br />V <br />I <br />C <br />E <br />S <br />IR <br />V <br />I <br />N <br />E <br /> <br />| <br /> <br />C <br />A <br /> <br />| <br /> <br />7 <br />1 <br />4 <br /> <br /> <br />5 <br />2 <br />0 <br /> <br />1 <br />2 <br />4 <br />3 <br />SHEET #: <br />SEAL: <br />PR <br />O <br />J <br />E <br />C <br />T <br /> <br />AD <br />D <br />R <br />E <br />S <br />S <br />: <br />20 <br />2 <br />3 <br /> <br />E <br />. <br /> <br />F <br />R <br />U <br />I <br />T <br /> <br />S <br />T <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />1 <br />RESTRICTIVE NOTICE: <br />THE RECIPIENT <br />ACKNOWLEDGES THAT <br />INFORMATION, PLANS, <br />SPECIFICATIONS, AND DESIGNS <br />CONTAINED IN THESE <br />DRAWINGS ARE THE <br />CONFIDENTIAL PROPERTY OF <br />MOONSHOT CONSULTANCY LLC <br />AND THE CONTENTS SHALL NOT <br />BE DISCLOSED TO OTHERS, <br />USED OR REPRODUCED IN <br />WHOLE OR IN PART FOR ANY <br />PURPOSE WITHOUT THE PRIOR <br />WRITTEN CONSENT OF <br />MOONSHOT CONSULTANCY LLC. <br />SH <br />E <br />E <br />T <br /> <br />N <br />A <br />M <br />E <br />: <br />A3 <br />PR <br />O <br />P <br />O <br />S <br />E <br />D <br /> <br />F <br />L <br />O <br />O <br />R <br /> <br />P <br />L <br />A <br />N <br />S <br />SYMBOLS LIST <br />NEW WALL [PER DETAIL #/D] <br />EXISTING WALL TO REMAIN <br />EXISTING DEMISING WALL [PER DETAIL #6/D] <br />DOWNLIGHT - RECESS-MOUNT IN CAN. UL LISTED FOR WET <br />LOCATIONS. "?" DENOTES SWITCH LEG. <br />LIGHT FIXTURE - SURFACE-MOUNT ON JUNCTION BOX. UL <br />LISTED FOR WET LOCATIONS. "?" DENOTES SWITCH LEG. <br />SINGLE-POLE / THREE-WAY LINE-VOLTAGE TOGGLE SWITCH - <br />WALL-MOUNT ON FLUSH OUTLET BOX +45"AFF(UNO) W/ <br />MULTIPLE SWITCHES UNDER COMMON COVER PLATE. "?" <br />DENOTES SWITCH LEG. <br />STANDARD / GFCI-TYPE DUPLEX RECEPTACLE - WALL-MOUNT <br />ON FLUSH OUTLET BOX +18"AFF. DEDICATED GFI CIRCUITS. <br />STANDARD / GFCI-TYPE DUPLEX RECEPTACLE - WALL-MOUNT <br />ON FLUSH OUTLET BOX +45"AFF(UNO). DEDICATED GFI <br />CIRCUITS. <br />TV BOX - WALL-MOUNT (2) 2-GANG RECESSED TV BOX W/ A <br />DUPLEX AND CONNECTED BY LOW VOLTAGE PATHWAY AT <br />+18"AFF & +52"AFF. 1/2" PLY BACKING. <br />(1) 220V + (1) 120V GFI-TYPE OUTLETS - WALL-MOUNT ON <br />FLUSH 2-GANG OUTLET BOX +18"AFF. <br />DISCONNECT SWITCH - CONNECT EQUIPMENT TO <br />HORSEPOWER-RATED SWITCH & FUSES SIZED PER <br />MANUFACTURER REQUIREMENTS. WALL-MOUNT +45"AFF(UNO). <br />WEATHERPROOF AS REQUIRED. <br />SMOKE & CARBON MONOXIDE DETECTOR & ALARM - CEILING / <br />WALL-MOUNT PER MANUFACTURES SPECIFICATIONS. <br />SUPPLY REGISTER - MINIMUM 6" DIAMETER W/ GRILLE AND <br />LOUVER. SIZE DUCTS PER DETAIL #12/D & TABLE 7.1 / ASHRAE <br />62.2. <br />GENERAL NOTES <br />1.DOORS TO BE 1-3/8" (INTERIOR) & 1-3/4" (EXTERIOR) THICK WITH 36" DEEP <br />DOOR-WIDTH LANDINGS SLOPED 2% AWAY [CRC §R311.3]. THRESHOLDS <br />TO BE 3/4" (SLIDING) & 1/2" (SWING) [CRC §R1010.1.7]. REFER TO <br />PROPOSED PLANS FOR HEIGHT & WIDTH [CBC §1132A]. <br />3.GLAZING WITHIN 24" OF DOORS & 60" OF SHOWERS / TUBS SHALL BE <br />TEMPERED SAFETY GLASS [CRC §R308.4] <br />FENESTRATION SHALL HAVE A U-FACTOR = 2.26, SHGC = 0.83 & <br />CERTIFICATE LABEL [CEC §110.6]. VENTILATION & LIGHTING <br />REQUIREMENTS [CBC §1202 & 1204}. <br />4.DEMISING WALLS & GARAGES TO BE 1-HOUR FIRE-RATED FLOOR TO ROOF <br />WITH 1-3/8" SELF-CLOSING, SELF LATCHING, SOLID-CORE, 20 MINUTE <br />FIRE-RATED DOOR. [DETAIL #3/D & CRC §R302]. <br />5.OPERABLE EMERGENCY ESCAPE & RESCUE TO BE IN PROVIDED IN <br />SLEEPING SPACES AND OPEN DIRECTLY TO A PUBLIC WAY W/ A <br />NET-CLEAR OPENINGS OF 30"x30" & A BOTTOM OF 44"AFF. [CRC §R310] <br />6.SETBACKS FOR (N) STRUCTURES TO BE 5'-0" FROM PROPERTY LINE. <br />7.SMOKE & CARBON MONOXIDE ALARMS TO BE (#1) INSTALLED INSIDE & <br />OUTSIDE EACH SLEEPING ROOM WITH A MINIMUM OF 3'-0" FROM <br />BATHROOM DOORS. (#2) INTERCONNECTED IN SUCH A MANNER THAT THE <br />ACTIVATION OF ONE ALARM WILL ACTIVATE ALL OF THE ALARMS IN THE <br />INDIVIDUAL UNIT. (#3) CLEARLY AUDIBLE IN ALL BEDROOMS OVER <br />BACKGROUND NOISE LEVELS WITH ALL INTERVENING DOORS CLOSED. <br />(#4) PROVIDED WITH BATTERY BACK-UP. [CRC §R314 & §R315] <br />8.PLUMBING FIXTURES & WALLS TO BE (#1) PROVIDED WITH WATER, WASTE <br />& VENT. (#2) SIZED PER PLUMBING FIXTURE SCHEDULE. (#3) CONNECT TO <br />EXISTING SUPPLY [DETAIL #3/D]. (#4) 2"x6" STUDS WALLS. [CBC §2308.5] <br />9.HOT & COLD WATER TUBING TO BE TYPE "K" COPPER WITH LEAD FREE <br />SOLDERED. WASTE LINE SHALL BE PVC. PIPING TO BE SEISMICALLY <br />BRACED IN ACCORDANCE WITH SMACNA GUIDELINES AND INSTALLED <br />WITHOUT ALTERATION TO CEILING MEMBERS. SHOWERS TO BE <br />PROVIDED WITH THERMOSTATIC / PRESSURE-BALANCING TYPE MIXING <br />VALVES. [DETAIL #3/D & CPC §R604] <br />10.SHOWER / BATHTUB GLAZING TO BE TEMPERED [CBC §R2406.4.5] AND <br />FLOORS & WALLS TO BE FINISHED WITH A NONABSORBENT SURFACE TO <br />6'-0"AFF. [DETAIL #4/D & CRC §R307.2] <br />11.RECEPTACLES TO BE TAMPER RESISTANT [CEC §406.12]. KITCHEN, <br />BATHROOM, WASHER / DRYER, & LAUNDRY MACHINE CIRCUITS SHALL BE <br />GFI & DEDICATED. [CEC §210.11 & §406.12] <br />12.LUMINAIRES TO BE UL WET-LOCATION RATED, HIGH EFFICACY [BEES <br />§150(K)(1)(A)] & CONTROLLED BY DIMMER SWITCH. [BEES §150(K)(2A)(F)] <br />PLAN NOTES <br />1.PROVIDE SKYLIGHT W/ (4) 2"x4" SUPPORTS & 1-HOUR FIRE ASSEMBLY <br />DRYWALL ALL SIDES. INSTALL ON TOP OF UNALTERED ROOF MEMBERS <br />PER DETAIL #4/D. [VELUX FCM 02-0310 - ESR-0199] SKYLIGHTS SHALL BE <br />TESTED BY AN APPROVED INDEPENDENT LABORATORY & BEAR A LABEL <br />IDENTIFYING MANUFACTURER, PERFORMANCE GRADE RATING & <br />APPROVED INSPECTION AGENCY TO INDICATE COMPLIANCE W/ AAMA / <br />WDMA / CSA 101 / I.S.2 / A440. [PER CRC §R308.6.9] <br />2.REPLACE BLOCK WALL WITH 1-HOURS FIRE RATED 2x4 STUD WALL PER <br />DETAIL #5/D. <br />3.PROVIDE 5" SLAB. CONNECT TO EXISTING FOOTINGS PER DETAIL #2/D. <br />DELIVER CONCRETE TO ATRIUM VIA PUMP & HOSE THROUGH FRONT <br />DOOR. <br />? <br />? <br />S <br />? <br />S <br />? <br />TV <br /># <br />(E <br />) <br /> <br />W <br />/ <br />D <br />(E <br />) <br /> <br />W <br />/ <br />D <br />(N <br />) <br /> <br /> <br />G <br />Y <br />M <br />(E <br />) <br />W <br />H <br />2' <br />4' <br />12' <br />4' <br />1 <br />4' <br />1' <br />1 <br />BU <br />I <br />L <br />T <br />- <br />I <br />N <br />DI <br />S <br />H <br />W <br />A <br />S <br />H <br />E <br />R <br />WI <br />T <br />H <br /> <br />A <br />I <br />R <br /> <br />G <br />A <br />P <br />KI <br />T <br />C <br />H <br />E <br />N <br />MA <br />S <br />T <br />E <br />R <br />BE <br />D <br />R <br />O <br />O <br />M <br />OF <br />F <br />I <br />C <br />E <br />GU <br />E <br />S <br />T <br />BE <br />D <br />R <br />O <br />O <br />M <br />LI <br />V <br />I <br />N <br />G <br />RO <br />O <br />M <br />EN <br />T <br />R <br />Y <br />W. <br />I <br />. <br />C <br />. <br />MA <br />S <br />T <br />E <br />R <br />BA <br />T <br />H <br />GU <br />E <br />S <br />T <br />BA <br />T <br />H <br />PA <br />T <br />I <br />O <br />GA <br />R <br />A <br />G <br />E <br />(N <br />) <br /> <br />B <br />A <br />R <br />N <br /> <br />D <br />O <br />O <br />R <br />2021 E FRUIT ST <br />2025 E FRUIT ST <br />TV <br />S <br />SS <br />S <br />S <br />17'-9"16' <br />16 <br />' <br />12 <br />' <br />- <br />2 <br />" <br />30'-2" <br />16 <br />' <br />97'-6" <br />9' <br />- <br />1 <br />0 <br />" <br />32'-5" <br />10'-7"15' <br />12 <br />' <br />- <br />7 <br />" <br />5' <br />- <br />5 <br />" <br />7'-7" <br />4' <br />- <br />9 <br />" <br />5'-10" <br />7'-6" <br />15'-10"24'-6" <br />9'-6" <br />19 <br />' <br />- <br />2 <br />" <br />TV <br />9'-8" <br />3 <br />2 <br />4' <br />- <br />9 <br />" <br />18 <br />' <br />- <br />1 <br />0 <br />" <br />FR <br />U <br />I <br />T <br /> <br />S <br />T <br />PR <br />O <br />P <br />E <br />R <br />T <br />Y <br /> <br />L <br />I <br />N <br />E <br />N. <br />I <br />. <br />C <br />. <br />11'-5"19'-10" <br />PROPERTY LINE <br />2023 E Fruit St - <br />10111958511/21/2024