My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2005 W Picasso - Plan
PBA
>
Building
>
ProjectDox
>
P
>
Picasso
>
2005 W Picasso
>
2005 W Picasso - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/5/2025 7:34:33 AM
Creation date
6/5/2025 7:34:22 AM
Metadata
Fields
Template:
Plan
Permit Number
20182595
101118992
Full Address
2005 W Picasso
Document Relationships
101118992 - Permit
(Permit - Plan)
Path:
\Building\Permits\P\Picasso\2005 W Picasso
20182595 - Permit
(Permit - Plan)
Path:
\Building\Permits\P\Picasso\2005 W Picasso
Rectangle
ID:
1
Creator:
Import Agent
Created:
6/5/2025 7:34 AM
Modified:
6/4/2025 1:54 PM
ID:
2
Creator:
Import Agent
Created:
6/5/2025 7:34 AM
Modified:
6/4/2025 1:54 PM
ID:
3
Creator:
Import Agent
Created:
6/5/2025 7:34 AM
Modified:
6/4/2025 1:54 PM
ID:
4
Creator:
Import Agent
Created:
6/5/2025 7:34 AM
Modified:
6/4/2025 1:54 PM
ID:
5
Creator:
Import Agent
Created:
6/5/2025 7:34 AM
Modified:
6/4/2025 1:54 PM
ID:
6
Creator:
Import Agent
Created:
6/5/2025 7:34 AM
Modified:
6/4/2025 1:54 PM
ID:
7
Creator:
Import Agent
Created:
6/5/2025 7:34 AM
Modified:
6/4/2025 1:54 PM
ID:
8
Creator:
Import Agent
Created:
6/5/2025 7:34 AM
Modified:
6/4/2025 1:54 PM
ID:
9
Creator:
Import Agent
Created:
6/5/2025 7:34 AM
Modified:
6/4/2025 1:54 PM
ID:
10
Creator:
Import Agent
Created:
6/5/2025 7:34 AM
Modified:
6/4/2025 1:54 PM
ID:
11
Creator:
Import Agent
Created:
6/5/2025 7:34 AM
Modified:
6/4/2025 1:54 PM
ID:
12
Creator:
Import Agent
Created:
6/5/2025 7:34 AM
Modified:
6/4/2025 1:54 PM
ID:
13
Creator:
Import Agent
Created:
6/5/2025 7:34 AM
Modified:
6/4/2025 1:54 PM
ID:
14
Creator:
Import Agent
Created:
6/5/2025 7:34 AM
Modified:
6/4/2025 1:54 PM
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
20
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
MTO <br />UTILITY <br />UTILITY <br />BI-DIRECTIONAL <br />METER <br />PV SYSTEM EQUIPPED <br />WITH RAPID SHUTDOWN <br />G <br />60A <br />2Pole <br />MAIN <br />OCPD <br />EXISTING GROUND; <br />MAY REQUIRE NEW GROUNDING <br />ELECTRODES: SEE NOTE BELOW <br />PV BACKFED BREAKER: <br />SHALL BE POSITIONED AT THE <br />OPPOSITE END OF MAIN BREAKER <br />MAIN SERVICE PANEL (E) <br />1PH 3W 240VAC <br />225A Bus Rating (E) <br />200A Main OCPD (Non-Center Fed) <br />200A <br />(3) #6 AWG THWN-2 <br />(1) #8 AWG THWN-2 GROUND <br />1" EMT CONDUIT @ 6FT <br />SOLAREDGE: SE7600H-US INVERTER <br />1PH 240VAC NEMA 3R <br />W/ INTEGRATED <br />DC DISCONNECT AND <br />RAPID SHUTDOWN <br />PER NEC 2017 690.12 <br />(4) #10 AWG THWN-2 <br />(1) #8 AWG THWN-2 GROUND <br />3/4" EMT CONDUIT @ 60FT <br />JUNCTION <br />BOX @ <br />ARRAY <br />MOUNTED <br />ON RAIL <br />NEMA 3R <br />SYSTEM CONFIGURATION <br />Number of Modules <br />Modules per String <br />EXISTING Module Type <br />Number of Inverters <br />Inverter Model <br />PV OCPD Size @ 125% PV AC Current <br />Main Breaker Ampere Rating <br />Service Bus Ampere Rating <br />AC Watts CEC Rated <br />DC Watts STC <br />Operating AC Voltage <br />18 <br />2 STRINGS OF (9) MODULES <br />(15) Q-CELLS QPEAK-DUO BLK-G10+ 400W <br />1 <br />SOLAREDGE SE7600H-US <br />40A <br />200A <br />225A <br />5.52 kW <br />6 kW <br />240VAC <br />(E)- EXISTING <br />(P)- PROPOSED # OF MODULES - 18 <br /># OF INVERTERS - 1 <br /># OF BATTERIES - 2 <br />MODULES INTERCONNECTED PER NEC SECTIONS 690.48, 690.43 & 250.136A <br />USING #10 AWG PV WIRE AND GROUNDED BY #6 BARE CU. PER NEC <br />SECTIONS 690.45 & 250.122. (TYPICAL FOR ALL ARRAYS) EXPOSED WIRE <br />SHALL BE OF USE-2 INSULATION AND ALL EXPOSED GROUND WIRE SHALL <br />BE BARE CU. MODULES GROUND BY ILSCO GBL-4DBT LUGS PER UL 2703 <br />Solar Module Ratings:Optimizer Ratings: <br />Q-CELLS Q.PEAK DUO-BLK-G10+ 400W SOLAREDGE P400 POWER OPTIMZER <br />Pmax <br />Vmpp <br />Impp <br />Voc <br />Isc <br />400W <br />37.13V <br />10.77A <br />45.3V <br />11.14A <br />Max Input Voltage: 80V <br />Max Input Current: 12.63A <br />Max Output Voltage: 60V <br />Max Output Current: 15A <br />Min/Max String Length: 8-25 <br />Inverter Ratings: <br />SOLAREDGE SE7600H-US INVERTER <br />Grid Voltage: 240V Phase: Single <br />Max Amps Out: 32A <br />Efficiency: 99.2% <br />Integrated DC Disconnect <br />Rapid Shutdown: Yes <br />ELECTRICAL NOTES: <br />1.ALL CONDUCTORS SHALL BE COPPER. ALL COMPONENTS ARE UL LISTED AND CEC CERTIFIED, WHERE WARRANTED. <br />2.MODULES AND RACKING GROUNDING METHOD - ALL MODULES WILL BE GROUNDED IN ACCORDANCE WITH CODE AND MANUFACTURER'S <br />INSTALLATION INSTRUCTIONS. <br />3.IF THE EXISTING MAIN SERVICE PANEL DOES NOT HAVE VERIFIABLE GROUNDING ELECTRODE, A GROUNDING ELECTRODE ROD SHALL BE <br />INSTALLED, WHERE #8 THWN-2 SERVES AS BOTH EQUIPMENT GROUND AND GROUNDING ELECTRODE CONDUCTOR. SUPPLEMENTAL GROUNDING <br />ELECTRODE REQUIRED WHERE EXISTING GROUNDING ELECTRODE HAS RESISTANCE OF MORE THAN 25 OHMS, OR IF RESISTANCE TESTING <br />RESULTS ARE NOT PROVIDED (CEC 690.47(A)). IF REQUIRED MULTIPLE GROUNDING ELECTRODE RODS MUST BE INSTALLED AT LEAST 6' APART. <br />(CEC 250.53 (A)(3)). <br />4.THE GEC/EGC SHALL BE CONTINUOUS, OR WHEN SPLICED, THE SPLICE SHALL BE MADE BY IRREVERSIBLE CRIMP OR EXOTHERMIC WELD. <br />5.EXPOSED NON-CURRENT CARRYING METAL PARTS OF MODULE FRAMES, EQUPMENT, AND CONDUCTOR ENCLOSURES SHALL BE GROUNDED IN <br />ACCORDANCE WITH 250.13 OR 250.136 (a) REGARDLESS OF VOLTAGE. <br />6.MARKING WILL BE PROVIDED IN A CCORDANCE WITH CAL FIRE SOLAR PHOTOVOLTAIC INSTALLATION GUIDELINES. <br />7.UTILITY WILL BE NOTIFIED PRIOR TO USE AND ACTIVATION OF AN SOLAR INSTALLATION. SYSTEM WILL BE COMMISSIONED BY OWNER PER UTILITY <br />INTERCONNECTION AGREEMENT. <br />8.AC AND DC CONDUCTOR SIZING AND TERMINATIONS AT J-BOXES WERE CALCULATED IN A CCORDANCE WITH 2022 CEC. ALL WIRES TO BE <br />PROVIDED WITH STRAIN RELIEF AT ALL ENTRY TO JUNCTION BOXES AS REQUIRED BY THE BOX LISTING. <br />9.DC SOURCE AND OUTPUT CIRCUITS SHALL BE CONTAINED IN A METAL RACEWAY/ENCLOSURE WITHIN A BUILDING/ATTIC/WALLS AND SHALL BE <br />IDENTIFIED EVERY 10' PER NEC 690.3(E). <br />SOLAREDGE P400 <br />POWER OPTIMZER: <br />(1) PER SOLAR <br />MODULE (TYP) <br />SOLAR MODULE: <br />Q-CELLS <br />Q.PEAKDUOBLKG10+ <br />(TYP) <br />AMPACITY <br />CALCULATIONS <br />Array to J-Box <br />J-Box to Inverter <br />Inverter to Service Panel <br />WIRE AMPACITY TABLE <br />310.15(B)(16) / PV-1KV-90°C <br />10AWG / 10AWG / 8AWG <br />THERMAL DERATE FACTOR <br />310.15(B)(2)(a) / (ON ROOF)(C°) <br />51 / 51 / 29 <br />NUMBER OF CONDUCTORS <br />310.15(B)(3)(a) <br />4-6 / 4-6 / 0-3 <br />40AMP <br />40AMP <br />50AMP <br />0.75 <br />0.75 <br />1 <br />0.8 <br />0.8 <br />1 <br />X <br />X <br />X <br />X <br />X <br />X <br />MAXIMUM <br />ALLOWABLE <br />AMPACITY <br />PV <br />DESIGN <br />AMPACITY <br />= <br />= <br />= <br />24 <br />24 <br />50 <br />15 <br />15 <br />40 <br />9 <br />(3) #8 AWG THWN-2 <br />(1) #8 AWG THWN-2 GROUND <br />3/4" EMT CONDUIT @ 6FT <br />LG CHEM <br />RESU16 <br />16KWH <br />BATTERY <br />SOLAREDGE BACKUP <br />INTERFACE BI-NUSGN-01 <br />1PH 3W 240VAC <br />MLO NEMA 3R <br />40A <br />2Pole <br />SUBPANEL (E) <br />1PH 3W 240VAC <br />125A BUS <br />MLO NEMA 3R <br />Battery Ratings: <br />LG CHEM RESU16 (16KWH BATTERY) <br />Grid Voltage: 240V Phase: Single <br />Rated Output Current: 30A <br />Rated Continuous Output: 7 kVA <br />Usable Capacity: 16 kWh <br />(3) #10 AWG THWN-2 <br />(1) #8 AWG THWN-2 GROUND <br />3/4" EMT CONDUIT @ 6FT <br />(3) #6 AWG THWN-2 (CU) <br />(1) #8 AWG THWN-2 CU G.E.C. <br />1" EMT CONDUIT @ 6FT <br />AC DISCONNECT <br />KNIFE SWITCH <br />NON-FUSED <br />60A 240VAC <br />NEMA 3R 60A <br />2Pole <br />LG CHEM <br />RESU16 <br />16KWH <br />BATTERY <br />PROPOSED Module Type (3) Q-CELLS QPEAK-DUO BLK-G10+ 410W <br />Solar Module Ratings: <br />Q-CELLS Q.PEAK DUO-BLK-G10+ 410W <br />Pmax <br />Vmpp <br />Impp <br />Voc <br />Isc <br />410W <br />38.63V <br />10.61A <br />45.62V <br />11.13A <br />ALL EQUIPMENT IN RED IS EXISTING <br />9 <br />(6) EXISTING <br />(3) NEW <br />2005 W Picasso - <br />201825954/25/2024
The URL can be used to link to this page
Your browser does not support the video tag.