BATTERY <br />INPUT <br />COMBINER <br />INPUT <br />AC COMBINER <br />GND <br />N <br />AUX CONTACTS <br />N01 <br />N02 <br />NC1NC2 <br />NC3NC4 <br />N03 <br />CONSUMPTION CTs <br />TO <br />IQ GATEWAY <br />INSIDE <br />IQ COMBINER <br />300KCM - #1 <br />30 <br />0 <br />K <br />C <br />M <br /> <br />- <br /> <br /># <br />1 <br />40A/2P <br />IQ BATTERY <br />GN <br />D N <br />(N) 125A SELECTED <br />LOAD CENTER, 240V <br />THE ESS CIRCUIT BREAKER SHALL BE <br />SECURED IN PLACE BY AN ADDITIONAL <br />FASTENER PER SECTION 408.36(D). THE <br />BREAKER AND FASTENER SHALL BE MADE <br />BY THE SAME MANUFACTURER <br />PRODUCER'S STORAGE DEVICE(S) WILL NOT <br />CAUSE THE HOST LOAD EXCEED ITS NORMAL PEAK <br />DEMAND. NORMAL PEAK DEMAND IS DEFINED AS <br />THE HIGHEST AMOUNT OF POWER REQUIRED FROM <br />THE DISTRIBUTION SYSTEM BY PRODUCER'S <br />COMPLETE FACILITIES WITHOUT THE INFLUENCE <br />OR USE OF ENERGY STORAGE DEVICES. <br />(N)70A/2P <br />25A/2P <br />TRANSFER <br />ALL <br />BACKUP <br />LOADS <br />FROM <br />(E) <br />MSP <br />(N) 200A ENPHASE IQ SYSTEM CONTROLLER 3 <br />ENPHASE SC200D111C240US01 <br />BREAKERS IN IQ SYSTEM CONTROLLER 3 <br />WILL BE SECURED WITH HOLD DOWN KITS. <br />THIS WILL SATISFY THE REQUIREMENTS OF <br />SECTION 408.36 (D) <br />(N) RAPID SHUTDOWN <br />DEVICE <br />(NEC 706.15) <br />THE ESS CIRCUIT BREAKER SHALL BE <br />SECURED IN PLACE BY AN ADDITIONAL <br />FASTENER PER SECTION 408.36(D). THE <br />BREAKER AND FASTENER SHALL BE MADE <br />BY THE SAME MANUFACTURER <br />SYSTEM CAN OPERATE IN ISLAND MODE <br />THIS MID ALLOWS A MICROGRID SYSTEM TO <br />SEPARATE FROM AND RECONNECT TO <br />OPERATE IN PARALLEL WITH A PRIMARY <br />POWER SOURCE (2022 NEC, ARTICLE 705) <br />(E) <br />G <br />(N) 60A <br />AC DISCONNECT <br />EATON DG222URB <br />240V NEMA-3R <br />(N) <br />MAIN SERVICE PANEL,240V <br />GROUNDING ELECTRODE & <br />AUXILIARY GROUNDING <br />ELECTRODE AS NEEDED PER <br />CEC 690.47 (6 FEET APART) <br /> (E)200A CENTER FED <br />ME <br />T <br />E <br />R <br /> <br /># <br />2 <br />2 <br />2 <br />0 <br />1 <br />3 <br />- <br />5 <br />8 <br />7 <br />2 <br />1 <br />5 <br />(E) <br />200A/2P <br />(N) <br />70A/2P <br />L <br />LL <br />L <br />GN <br />D N <br />(E) <br />LOADS <br />1-PHASE <br />+ <br />- <br />CTRL (N) ENPHASE ENERGY <br />IQBATTERY-5P-1P-NA <br />[240V] [SI1-SB] + <br />IQ CONTROLLER 3 <br />SC200D111C240US01 + <br />IQ COMBINER 4C <br />X-IQ-AM1-240-5C [CRD-PCS NEM] <br />+ <br />- <br />CTRL(N) ENPHASE ENERGY <br />IQBATTERY-5P-1P-NA <br />[240V] [SI1-SB] + <br />IQ CONTROLLER 3 <br />SC200D111C240US01 + <br />IQ COMBINER 4C <br />X-IQ-AM1-240-5C [CRD-PCS NEM] <br />THWN-2 <br />3-#8 <br />1-#8 GRND <br />3/4" EMT CONDUIT <br />AFCI PROTECTION <br />WILL BE PROVIDED <br />FOR 15A AND 20A <br />BREAKERS THAT ARE <br />RELOCATED MORE <br />THAN 6' FROM THE <br />ORIGINAL BREAKER <br />SOURCE <br />(E) 125A ENPHASE IQ <br />COMBINER 4C NEMA-3R <br />X-IQ-AM-1-240-4C <br />[CRD-PCS NEM) <br />15A/2P <br />20A/2P <br />EXISTING SOLAR 5.72kW DC, 240V <br />(13) DNA-144-MF26-440W SOLAR MODULES <br />(13) ENPHASE IQ8A-72-2-US MICROINVERTER, 240 <br />(1) 125A ENPHASE COMBINER 4C <br />(1) 30A AC DISCONNECT <br />EACH WITH AN <br />(E) ENPHASE IQ8A-72-2-US <br />MICROINVERTER, 240V <br />AC <br />(E) <br />J-BOX <br />G <br />1 BRANCH OF <br />MODULES07 <br />EE <br />(E) 30A <br />AC DISCONNECT <br />SQUARE-D <br />240V NEMA-3R <br />G <br />(EXISTING) <br />THWN-2 <br />3-#10 <br />1-#8 GRND <br />3/4" EMT CONDUIT <br />THWN-2 <br />3-#4 <br />1-#8 GRND <br />1" EMT CONDUIT <br />THWN-2 <br />3-#4 <br />1-#8 GRND <br />1" EMT CONDUIT <br />EACH WITH AN <br />(E) ENPHASE IQ8A-72-2-US <br />MICROINVERTER, 240V <br />AC <br />(E) <br />J-BOX <br />G <br />1 BRANCH OF <br />MODULES06 <br />EE <br />20A/2P <br />THWN-2 <br />3-#8 <br />1-#8 GRND <br />3/4" EMT CONDUIT <br />THWN-2 <br />3-#8 <br />1-#8 GRND <br />3/4" EMT CONDUIT <br />NFT <br />NFT <br />ENPHASE IQ GATEWAY <br />ENV2-IQ-AM1-240 <br />enphase <br />ENERGY <br />ENPHASE <br />C E L L <br />MODEM <br />WIRELESS COMMUNICATION <br />ADAPTER FOR ENPHASE <br />ENERGY SYSTEM <br />CELLULAR REVENUE-GRADE <br />PRODUCTION METERING <br />FACTORY INSTALLED <br />40A/2P <br />E7 <br />SHEET NUMBER: <br />SE <br />M <br />P <br />E <br />R <br /> <br />S <br />O <br />L <br />A <br />R <br />I <br />S <br />18 <br />0 <br />5 <br /> <br />J <br />O <br />H <br />N <br /> <br />T <br />O <br />W <br />E <br />R <br />S <br /> <br />A <br />V <br />E <br />EL <br /> <br />C <br />A <br />J <br />O <br />N <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />0 <br />2 <br />0 <br />C- <br />1 <br />0 <br /> <br />L <br />I <br />C <br /> <br /># <br /> <br />9 <br />7 <br />8 <br />1 <br />5 <br />2 <br />Li <br />c <br />. <br /> <br />H <br />o <br />l <br />d <br />e <br />r <br /> <br />D <br />i <br />g <br />i <br />t <br />a <br />l <br />l <br />y <br /> <br />S <br />t <br />a <br />m <br />p <br />e <br />d <br />PR <br />O <br />J <br />E <br />C <br />T <br /> <br />F <br />O <br />R <br />: <br /> <br />PR <br />O <br />P <br />O <br />S <br />E <br />D <br /> <br />DRAWN BY: <br />DATE: <br />(DC) kW: <br />PROJECT #: <br />Jo <br />h <br />n <br /> <br />A <br />l <br />m <br />o <br />n <br />d <br />EVOLUTION <br />06/28/2024 <br />98307 <br />(E)5.72 <br />LE <br />T <br />I <br />C <br />I <br />A <br /> <br />S <br />I <br />L <br />V <br />A <br /> <br />A <br />N <br />D <br /> <br />GL <br />O <br />R <br />I <br />A <br /> <br />S <br />I <br />L <br />V <br />A <br /> <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />4 <br /> <br />19 <br />0 <br />8 <br /> <br />S <br /> <br />S <br />U <br />L <br />L <br />I <br />V <br />A <br />N <br /> <br />S <br />T <br />, <br />(7 <br />1 <br />4 <br />) <br /> <br />5 <br />9 <br />7 <br />- <br />4 <br />6 <br />1 <br />2 <br />40 <br />8 <br />1 <br />0 <br />2 <br />1 <br />1 <br /> <br /> E <br />N <br />E <br />R <br />G <br />Y <br /> <br />S <br />T <br />O <br />R <br />A <br />G <br />E <br /> <br />SY <br />S <br />T <br />E <br />M <br /> <br />S <br />I <br />Z <br />E <br />: <br /> <br />10 <br /> <br />k <br />W <br />h <br /> <br />E <br />S <br />S <br />MA <br />I <br />N <br /> <br />L <br />I <br />N <br />E <br />: <br /> <br />6 <br />1 <br />9 <br />- <br />3 <br />5 <br />7 <br />- <br />4 <br />1 <br />4 <br />2 <br />THIS INSTALLATION WILL PROVIDE PARTIAL HOME BACKUP. <br />THE FOLLOWING LOADS WILL BACKUP. <br />1. 20A/1P PLUGS <br />2. 20A/1P MICROWAVE <br />3. 20A/1P PLUGS <br />4. 20A/1P KITCHEN PLUGS <br />5. 20A/1P REFRIGERATOR <br />6. 20A/1P PLUGS <br />7. 15A/1P LIGHT <br />8. 15A/1P LIGHT <br />9. 20A/1P PLUGS <br />10. 20A/1P PLUGS <br />No. E 22012 <br />SESFIOONRAP LDEENRGETINSIEGEERR <br />E LLAECCITRS ATIANTEROOFFIL CA <br />AMN IERDAOGHUTHE <br />AM <br />Exp. 09/30/25 <br />STAMPED 06/28/2024 <br />There appears to be 14 current <br />carrying conductors for the backup <br />loads. If all within one conduit longer <br />than 24", ampacity reduction will apply <br />and the wire sizes will need to be <br />increased. Refer to CEC 310.15, <br />310.15(C)(1) <br />MAS(19) <br />1908 S Sullivan St - <br />201833137/30/2024