1226 W. NINTH ST. <br />UPLAND, CA 91786 <br />310.487.1613 <br />HELLO@DREAMDESIGN.BUILD <br />DREAMDESIGN.BUILD <br />OWNER: <br />JUAN CAMACHO <br />ADDRESS: <br />1901 W HALL AVE <br />SANTA ANA, CA 92704 <br />SCOPE OF WORK: <br />(E) GARAGE WALLS TO BE <br />DRYWALLED (NO NEW INSULATION) <br />(N) EXTERIOR WATER HEATER <br />ENCLOSURE (TO MATCH EXISTING <br />HOME) <br />(E) COVERED PATIO & SHED TO BE <br />REMOVED. <br />UNPERMITED ELECTRICAL AND <br />PLUMBING WORK TO BE REMOVED <br />FROM GARAGE <br />UNPERMITED DRYWALL TO BE <br />REMOVED FROM GARAGE CEILING <br />PLANS PREPARED BY: <br />RESTRICTIVE NOTICE: <br />ALL DESIGNS, IDEAS, DETAILS, PLANS & <br />SPECIFICATIONS INDICATED BY THE DRAWINGS ARE <br />THE EXCLUSIVE PROPERTY OF DDB,LLC. THE PLANS <br />WERE CREATED AND DEVELOPED FOR USE ON AND <br />IN CONJUNCTION WITH THE SPECIFIC PROJECT <br />DESCRIBED HEREIN. NO PART THEREOF SHALL BE <br />REPRODUCED, COPIED, ADAPTED, MODIFIED OR <br />DISTRIBUTED TO OTHERS WITHOUT PRIOR WRITTEN <br />AND SPECIFIC CONSENT FROM DDB, LLC. <br />PROJECT INFO <br />A0.0 <br />SCALE: <br />DRAWN: <br />CHECKED: <br />DATE: <br />REVISION: <br />REVISION: <br />EDGAR VIDAL <br />9/18/24 <br />AS SHOWN <br />E. VIDAL <br />A0.0 <br />A1.0 <br />A2.1 <br />A2.2 <br />A2.3 <br />A3.0 <br />A4.0 <br />A5.0 <br />GB1.1 <br />GB1.2 <br />S1 <br />S2 <br />S3 <br />S4 <br />PROJECT INFO <br />EXISTING & PROPOSED SITE PLANS <br />EXISTING FLOOR PLAN <br />EXISTING ROOF PLAN <br />EXISTING ELEVATIONS <br />PROPOSED FLOOR PLAN <br />PROPOSED ELEVATIONS <br />SECTIONS <br />GREEN BUILDING <br />GREEN BUILDING <br />FOUNDATION PLAN <br />FRAMING PLAN <br />WOOD FRAME PRESCRIPTIVE PROVISIONS <br />PRESCRIPTIVE STRUCTURAL DETAILS <br />SHEET INDEX <br />VICINITY MAP <br />1. THE METHOD OF CLEARING AND STRIPPING SHOULD BE VERIFY BY THE CONTRACTOR. <br />2. ALL SURFACE VEGETATION, DEBRIS AND STRUCTURES TO BE DEMOLISHED SHALL BE REMOVED FROM THE SITE PRIOR <br />TO COMMENCING SITE PREPARATION, EXCAVATION OR PLACEMENT FILL. <br />3. FILL FOR FLOOR SLABS AND FOUNDATION TRENCHES SHALL CONSIST OF NATIVE SOIL. <br />4. NATIVE SOIL PLACED FOR SLAB SUPPORT SHALL BE PLACED IN LAYERS NOT EXCEEDING 4" WHEN COMPACTED. <br />5. IMPORT FOR SLAB SUPPORT SHALL CONSIST OF SAND, GRAVELY SAND OR SILTY SAND AND SHALL HAVE A EXPANSION <br />INDEX OF LESS THAN 30. <br />1. ALL WORK SHALL COMPLY WITH THE 2022 CALIFORNIA BUILDING CODE, TITLE 24 AND ALL APPLICABLE CODES, <br />REGULATIONS OR REQUIREMENTS OF THE CITY OR COUNTY HAVING JURISDICTION FOR THE PLACE OF THE BUILDING. <br />2. PERMITS SHALL BE OBTAINED FOR FENCES, POOLS, SPA OR RETAINING WALLS. <br />3. FINAL GRADING WORK SHALL COMPLY WITH 2019 CBC AND SHALL PROVIDE POSITIVE DRAINAGE FROM ALL PARTS OF <br />THE BUILDING AND SHALL NOT DRAIN ONTO ADJACENT PROPERTIES. <br />4. ALL SURFACES SHALL BE SLOPED TO DRAIN WATER AWAY FROM THE BUILDING. <br />5. AT TIME OF PERMIT ISSUANCE, THE CONTRACTOR SHALL SHOW THEIR VALID "WORKERS COMPENSATION" INSURANCE <br />CERTIFICATE. <br />6. ALL WORK SHALL CONFORM TO ALL REQUIREMENTS OF THE INFORMATION INDICATED ON THESE PLANS. <br />7. BUILDING ADDRESS NUMBERS SHALL BE PROVIDED ON THE FRONT OF ALL BUILDINGS AND SHALL BE VISIBLE AND <br />LEGIBLE FROM THE STREET FRONTING THE PROPERTY, SAID NUMBERS SHALL CONTRAST WITH THEIR BACKGROUND. <br />1. ROOF OBSTRUCTIONS SUCH AS TELEVISION ANTENNA, GUY WIRES, SOLAR PANELS, RAZOR RIBBON FENCE, CABLE OR <br />OTHER OBSTRUCTIONS SHALL NOT PREVENT FIRE DEPARTMENT ACCESS OR EGRESS IN THE EVENT OF FIRE. <br />2. PROVIDE COLLISION BARRIERS ADEQUATE TO PROTECT CONTROL METERS, REGULATORS AND PIPING FOR <br />HAZARDOUS MATERIALS THAT ARE EXPOSED TO VEHICULAR DAMAGE LAMC 57.12.02. <br />3. THE INDOOR STORAGE OF COMBUSTIBLE MATERIALS SHALL BE REGULATED IN RELATION TO ARRANGEMENT, <br />LOCATION, SIZE OF AREAS, HEIGHT SEPARATIONS AND HOUSEKEEPING. <br />1. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS OF THE JOB SITE BEFORE STARTING ANY WORK <br />AND BE RESPONSIBLE FOR THE SAME, THE ARCHITECT SHALL BE NOTIFY OF ANY DISCREPANCIES WHICH MAY EXIST. <br />CONTRACTOR SHALL NOT SCALE ANY DRAWINGS. <br />2. THE SPECIFICATIONS ARE OF A GENERAL NATURE AND MAY REFER TO WORK WHICH IS NOT REQUIRED. THEY ARE NOT <br />INTENDED TO SUPERSEDE ANY CONTRACTUAL AGREEMENT BETWEEN THE OWNER AND THE CONTRACTOR. <br />3. THE CONTRACTOR SHALL PROVIDE SUPERVISION TO PROPERLY EXECUTE THE PROJECT AND TO PROVIDE <br />ASSURANCE THE WORK IS IN ACCORDANCE WITH THE PLANS AND SPECIFICATIONS. <br />4. ALL NECESSARY PERMITS SHALL BE SECURED BY THE CONTRACTOR PRIOR TO START ANY CONSTRUCTION. <br />A. AT THE TIME OF ROUGH INSTALLATION, OR DURING STORAGE ON THE CONSTRUCTION SITE AND UNTIL FINAL STARTUP <br />OF THE HEATING, COOLING, AND VENTILATING EQUIPMENT, ALL DUCT AND OTHER RELATED AIR DISTRIBUTION <br />COMPONENT OPENINGS SHALL BE COVERED WITH TAPE, PLASTIC, SHEET METAL, OR OTHER ACCEPTABLE METHODS TO <br />REDUCE THE AMOUNT OF WATER, DUST, AND DEBRIS WHICH MAY ENTER THE SYSTEM. <br />B. BUILDING MATERIALS WITH VISIBLE SIGNS OF WATER DAMAGE SHALL NOT BE INSTALLED. WALL AND FLOOR FRAMING <br />SHALL NOT BE ENCLOSED WHEN THE FRAMING MEMBERS EXCEED 19% MOISTURE CONTENT. INSULATION PRODUCTS <br />WHICH ARE VISIBLE WET OR HAVE HIGH MOISTURE CONTENT SHALL BE REPLACED OR ALLOWED TO DRY PRIOR TO <br />ENCLOSURE IN WALL OR FLOOR CAVITIES. <br />C. ALL MECHANICAL EXHAUST FANS IN ROOMS WITH A BATHTUB OR SHOWER SHALL COMPLY WITH THE FOLLOWING: <br />- FANS SHALL BE ENERGY STAR COMPLIANT AND BE DUCTED TO TERMITE OUTSIDE THE BUILDING. <br />- FANS MUST BE CONTROLLED BY A HUMIDITY CONTROL CAPABLE OF ADJUSTMENT BETWEEN A RELATIVE HUMIDITY <br />RANGE OF <br />< 50% TO A MAXIMUM OF 80% UNLESS FUNCTIONING AS A COMPONENT OF A WHOLE HOUSE VENTILATION SYSTEM. <br />1. PROVIDE 72 INCH HIGH NONABSORBENT WALL ADJACENT TO SHOWER, AND APPROVED SHATTER RESISTANT <br />MATERIALS FOR SHOWER. <br />2. ONLY LOW CONSUMPTION WATER CLOSETS SHALL BE PROVIDED. "PROVIDE ULTRA FLUSH WATER CLOSETS FOR ALL <br />NEW CONSTRUCTION. EXISTING SHOWER HEADS AND TOILETS MUST BE ADAPTED FOR LOW WATER CONSUMPTION." <br />3. ENCLOSED USABLE SPACE UNDER INTERIOR STAIRWAYS REQUIRES 1-HOUR FIRE RESISTIVE CONSTRUCTION ON <br />ENCLOSED SIDE. <br />4. EXIT DOORWAYS SHALL BE NOT LESS THAN 36" X 6'-8" (WIDTH AND HEIGHT). PROJECTIONS INCLUDING PANIC <br />HARDWARE, SHALL NOT REDUCE THE OPENING TO LESS THAN 32" CLEAR WIDTH. <br />5. PROVIDE 32" WIDE DOORS TO ALL ACCESSIBLE ROOMS WITHIN A DWELLING UNIT. <br />6. GLASS SKYLIGHTS SHALL COMPLY WITH 91.2409. PLASTIC SKYLIGHTS WITH 91.1006.12 <br />7. PROVIDE WINDOW WELLS (WITH FIXED LADDER) FOR EGRESS WINDOWS BELOW GRADE. <br />8. WATER HEATER IS REQUIRED TO BE ANCHORED. "WATER HEATER MUST BE STRAPPED TO WALL." <br />9. PROVIDE ACCESS TO THE BOTTOM OF COURT FOR CLEANING PURPOSES. <br />10. COURT MORE THAN TWO STORIES IN HEIGHT SHALL BE PROVIDED WITH A HORIZONTAL AIR INTAKE WITH A MINIMUM <br />AREA OF 10 SQ.FT. <br />1. WALL COVERING SHALL BE CEMENT PLASTER, TILE OR APPROVED EQ. WITHIN 72" ABOVE DRAIN. <br />2. MATERIALS OTHER THAN STRUCTURAL ELEMENTS TO BE MOISTURE RESISTANT MATERIALS: <br />3. GLASS ENCLOSURE DOORS MUST BE LABELED CATEGORY II SWING DOOR OUTWARD. <br />4. NET AREA OF SHOWER RECEPTOR NOT LESS THAN 1024 " OR 30" DIA CIR 510, 511, 5406, 5407, UBC STD. T-54 & D.C. 909. <br />5. BATHS WITHOUT OPENABLE WINDOWS SHALL BE PROVIDED WITH VENT FAN CAPABLE OF MINIMUM 5 AIR CHANGES <br />PER HR. <br />6. TOILET COMPARTMENT MINIMUM 30" WIDE WITH 24" CIR. IN FRONT OF TOILET. <br />7. PROVIDE MINIMUM 12" X 12" ACCESS AT TUB TRAP EXCEPT WHERE CONCERNED FIXED CONNECTIONS ARE OF BRASS <br />& WITHOUT SLIP JOINTS. <br />8. PROVIDE MECHANICAL VENTILATION CONNECTED DIRECTLY TO THE OUTSIDE CAPABLE OF PROVIDING FIVE A/P <br />CHANGES PER HOUR IN BATHROOMS, WATER CLOSET COMPARTMENTS, LAUNDRY ROOMS, AND SIMILAR ROOMS IF <br />REQUIRED OPENABLE WINDOWS ARE NOT PROVIDED <br />SITE PREPARATION <br />SITE NOTES <br />SPECIAL HAZARDS <br />MISCELLANEOUS <br />BUILDING CODE NOTES <br />FINISH MATERIAL POLLUTANT CONTROL <br />MATERIAL CONSERVATION & RESOURCE EFFICIENCY <br />ENVIRONMENTAL QUALITY <br />INTERIOR <br />BATH <br />A. ADHESIVE, SEALANTS AND CAULKS SHALL MEET OR EXCEED THE STANDARDS OUTLINED IN SECTION 4.504.2.1 AND <br />COMPLY WITH THE VOC LIMITS IN TABLES 4.504.1 AND 4.504.2 AS APPLICABLE. <br />B. PAINTS AND COATINGS SHALL MEET OR EXCEED THE STANDARDS OUTLINED IN SECTION 4.504.2.2. AND COMPLY WITH <br />THE VOC LIMITS IN TABLE 4.504.3. <br />C. AEROSOL PAINTS AND COATINGS SHALL MEET OR EXCEED THE STANDARDS OUTLINED IN SECTION 4.504.2.3 <br />D. ALL CARPET INSTALLED IN THE BUILDING INTERIOR SHALL MEET THE TESTING AND PRODUCT REQUIREMENTS OF ONE <br />OF HE FOLLOWING: <br />I. CARPET AND RUG INSTITUTE'S GREEN LABEL PLUS PROGRAM OR <br />II. CALIFORNIA DEPARTMENT OF PUBLIC HEALTH STANDARD METHODS FOR THE TESTING OF VOC EMISSIONS (SPEC <br />01350) OR <br />III. NSF/ANSI 140 AT THE GOLD LEVEL OR <br />IV. SCIENTIFIC CERTIFICATIONS SYSTEMS INDOOR ADVANTAGE GOLD <br />E. ALL CARPET CUSHION INSTALLED IN THE BUILDING INTERIOR SHALL MEET THE REQUIREMENTS OF THE CARPET AND <br />RUG INSTITUTE GREEN LABEL PROGRAM. CARPET ADHESIVES SHALL NOT EXCEED A VOC LIMIT OF 50 G/L. (4.504.3.1, <br />4.504.3.2) <br />F. A MINIMUM OF 80% OF FLOOR AREA RECEIVING RESILIENT FLOORING SHALL COMPLY WITH ONE OR MORE OF THE <br />FOLLOWING: <br />I. PRODUCTS CERTIFIED AS A LOW-EMITTING MATERIAL IN THE CHPS HIGH PERFORMANCE PRODUCTS DATABASE OR <br />II. PRODUCTS CERTIFIED UNDER UL GREEN GUARD GOLD (FORMERLY THE GREEN GUARD CHILDREN & SCHOOLS <br />PROGRAM), OR <br />III. CERTIFICATION UNDER THE RFCI FLOORSCORE PROGRAM OR <br />IV. MEET THE CALIFORNIA DEPARTMENT OF PUBLIC HEALTH STANDARD METHOD FOR THE TESTING OF VOC EMISSIONS <br />(SPEC 01350) <br />G. COMPOSITE WOOD PRODUCTS (HARDWOOD PLYWOOD, PARTICLE BOARD, AND MDF) INSTALLED ON THE INTERIOR OR <br />EXTERIOR OF HE BUILDING SHALL MEET OR EXCEED THE STANDARDS OUTLINED IN TABLE 4.504.5. VERIFICATION OF <br />COMPLIANCE WITH THESE SECTIONS MUST BE PROVIDED AT HE TIME OF INSPECTION. <br />ANNUAL SPACES AROUND PIPES, ELECTRIC CABLES, CONDUITS OR OTHER OPENINGS IN SOLE/BOTTOM PLATES AT <br />EXTERIOR WALLS SHALL BE PROTECTED AGAINST THE PASSAGE OF RODENTS BY CLOSING SUCH OPENINGS WITH <br />CEMENT MORTAR, CONCRETE MASONRY OR SIMILAR METHODS. <br />DOOR MARKER <br />AWINDOW MARKER <br />24 <br />A7.1 <br />24 <br />A4.1 <br />24 <br />A5.1 <br />24 <br />A5.1 <br />SECTION MARKER <br />ELEVATION MARKER <br />DETAIL MARKER <br />∙ 2022 CALIFORNIA RESIDENTIAL CODE <br />∙ 2022 CALIFORNIA BUILDING CODE <br />∙ 2022 CALIFORNIA PLUMBING CODE <br />∙ 2022 CALIFORNIA MECHANICAL CODE <br />∙ 2022 CALIFORNIA ELECTRICAL CODE <br />∙ 2022 CALIFORNIA ENERGY CODE. (TITLE 24) <br />∙ 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE <br />8 <br />A. THE CONSTRUCTION SHALL NOT RESTRICT A FIVE-FOOT CLEAR AND UNOBSTRUCTED ACCESS TO ANY WATER OR <br />POWER DISTRIBUTION FACILITIES (POWER POLES, PULL BOXES, TRANSFORMERS, VAULTS, PUMPS, METERS, <br />APPURTENANCES, ETC.) OR TO THE LOCATION OF THE HOOK-UP. THE CONSTRUCTION SHALL NOT BE WITHIN TEN FEET <br />OF ANY POWER LINES - WHETHER OR NOT THE LINES ARE LOCATED ON THE PROPERTY. FAILURE TO COMPLY MAY CAUSE <br />CONSTRUCTION DELAYS AND/OR ADDITIONAL EXPENSES. <br />B. AN APPROVED SEISMIC GAS SHUTOFF VALVE WILL BE INSTALLED ON THE FUEL GAS LINE ON THE DOWN STREAM SIDE <br />OF THE UTILITY METER AND BE RIGIDLY CONNECTED TO THE EXTERIOR OF THE BUILDING OR STRUCTURE CONTAINING <br />THE FUEL GAS PIPING. (PER ORDINANCE 170, 158) (INCLUDES COMMERCIAL ADDITIONS AND TI WORK OVER $10,000) <br />SEPARATE PLUMBING PERMIT IS REQUIRED. <br />C. PLUMBING FIXTURES ARE REQUIRED TO BE CONNECTED TO A SANITARY SEWER OR TO AN APPROVED SEWAGE <br />DISPOSAL SYSTEM (R306.3) <br />D. KITCHEN SINKS, LAVATORIES, BATHTUBS, SHOWERS, BIDETS, LAUNDRY TUBS AND WASHING MACHINE OUTLES SHALL <br />BE PROVIDED WITH HOT AND COLD WATER AND CONNECTED TO AN APPROVED WATER SUPPLY (R306.4) <br />E. BATHTUB AND SHOWER FLOORS, WALLS ABOVE BATHTUBS WITH A SHOWER HEAD, AND SHOWER COMPARTMENTS <br />SHALL BE FINISHED WITH A NON-ABSORBENT SURFACE. SUCH WALL SURFACES SHALL EXTEND TO A HEIGHT OF NOT <br />LESS THAN 6 FEET AOBVE THE FLOOR (R307.2) <br />F. PROVIDE ULTRA LOW FLUSH WATER CLOSETS FOR ALL NEW CONSTRUCTION. EXISTING SHOWER HEADS AND TOILETS <br />MUST BE ADAPTED FOR LOW WATER CONSUMPTION. <br />G. PROVIDE 72 INCH HIGH NON-ABSORBENT WALL ADJACENT TO SHOWER AND APPROVED SHATTER-RESISTANT <br />MATERIALS FOR SHOWER ENCLOSURE. (1209.2.3 & 1209.2.4) <br />H. UNIT SKYLIGHTS SHALL BE LABELED BY AN LA CITY APPROVED LABELING AGENCY. SUCH LABEL SHALL STATE THE <br />APPROVED LABELING AGENCY NAME, PRODUCT DESIGNATION AND PERFORMANCE GRADE RATING (RESEARCH REPORT <br />NOT REQUIRED). (R308.6.9) <br />I. WATER HEATER MUST BE STRAPPED TO WALL (SEC. 507.3, UPC) <br />M. SMOKE DETECTORS SHALL BE PROVIDED FOR ALL DWELLING UNITS INTENDED FOR HUMAN OCCUPANCY, UPON THE <br />OWNER'S APPLICATION FOR A PERMIT FOR ALTERATIONS, REPAIRS, OR ADDITIONS, EXCEEDING ONE THOUSAND <br />DOLLARS ($1,000). (R314.6.2) <br /> N.A.WHERE A PERMIT IS REQUIRED FOR ALTERATIONS, REPAIRS OR ADDITIONS EXCEEDING ONE THOUSAND DOLLARS <br />($1,000), EXISTING DWELLINGS OR SLEEPING UNITS THAT HAVE ATTACHED GARAGES OR FUEL BURNING APPLIANCES <br />SHALL BE PROVIDED WITH A CARBON MONOXIDE ALARM IN ACCORDANCE WITH SECTIONS R315.1. CARBON MONOXIDE <br />ALARMS SHALL ONLY BE REQUIRED IN THE SPECIFIC DWELLING UNIT OR SLEEPING UNIT FOR WHICH THE PERMIT WAS <br />OBTAINED. (R315.2) <br /> N.B.EVERY SPACE INTENDED FOR HUMAN OCCUPANCY SHALL BE PROVIDED WITH NATURAL LIGHT BY MEANS OF <br />EXTERIOR GLAZED OPENINGS IN ACCORDANCE WITH SECTION R303.1 OR SHALL BE PROVIDED WITH ARTIFICIAL LIGHT <br />THAT IS ADEQUATE TO PROVIDE AN AVERAGE ILLUMINATION OF 6 FOOT-CANDLES OVER THE AREA OF THE ROOM AT A <br />HEIGHT OF 30 INCHES ABOVE THE FLOOR LEVEL. (R303.1) <br />O. A COPY OF THE EVALUATION REPORT AND/OR CONDITIONS OF LISTING SHALL BE MADE AVAILABLE AT THE JOB SITE <br />ARCHITECTURAL DESIGNER <br />DREAM DESIGN BUILDNAME <br />ADDRESS <br />PHONE <br />1226 W. NINTH ST. <br />UPLAND, CA 91786 <br />310.487.1613 <br />E-MAIL HELLO@DREAMDESIGN.BUILD <br />WEBSITE DREAMDESIGN.BUILD <br />CLIENT <br />JUAN CAMACHO NAME <br />ABBREVIATIONS <br />A/C AIR CONDITIONER <br />A.F.F. ABOVE FINISHED FLOOR <br />A.F.G. ABOVE FINISHED GRADE <br />BOT. BOTTOM <br />B.O.F. BOTTOM OF FOOTING <br />C.C. CENTER TO CENTER <br />CL. CLOSET <br />CLG. CEILING <br />CMU CONCRETE MASONRY UNIT <br />DEMO DEMOLISH <br />D.S. DOWNSPOUT <br />DIA. DIAMETER <br />DIM. DIMENSION <br />DN. DOWN <br />D.P. DAMP PROOFING <br />E EXISTING <br />E.F. EXHAUST FAN <br />EXC. EXCAVATE <br />F.A.U. FORCED AIR UNIT <br />F.D. FLOOR DRAIN <br />FIN. FINISH <br />F.F. FINISH FLOOR <br />GALV. GALVANIZED <br />G.C. GENERAL CONTRACTOR <br />G.F.C.I. GROUND FAULT CIRCUIT <br />INTERUPT <br />G.F.I. GROUND FAULT INTERRUPT <br />G.T. GLAZED TILE <br />GYP. GYPSUM <br />H.V.A.C. HEATING, VENTILATION & <br />AIR CONDITIONING <br />H.W. HOT WATER <br />IN. INCH <br />INSUL. INSULATION <br />INT. INTERIOR <br />JST. JOIST <br />LFT. LINEAR FEET <br />LTG. LIGHTING <br />L.V.L. LAMINATED VENEER <br />LUMBER <br />MAS. MASONRY <br />MTL. METAL <br />MIN. MINIMUM <br />N NEW <br />N.T.S. NOT TO SCALE <br />O.C. ON CENTER <br />O.D. OUTSIDE DIAMETER <br />OPNG. OPENING / ROUGH OPENING <br />P.C.C. PORTLAND CEMENT <br />CONCRETE <br />PL.PLASTER <br />P.L.PROPERTY LINE <br />PLYWD. PLYWOOD <br />PTD. PAINTED <br />R.C. REINFORCED CONCRETE <br />R.D. ROOF DRAIN <br />R.D.L. ROOF DRAIN LEADER <br />R.O. ROUGH OPENING <br />R.O.W. RIGHT OF WAY <br />REINF. REINFORCED <br />SAN. SANITARY <br />S.D. SMOKE DETECTOR <br />SHT. SHEET <br />SHT'G. SHEATHING <br />SQ. FT. SQUARE FEET <br />SQ. IN. SQUARE INCHES <br />STD. STANDARD <br />T&B TOP & BOTTOM <br />T.O. TOP OF <br />U.N.O. UNLESS NOTED OTHERWISE <br />V.B. VAPOR BARRIER <br />W.C. TOILET (WATER CLOSET) <br />WD. WOOD <br />WDW. WINDOW <br />W.I.C. WALK-IN CLOSET <br />WP. WEATHERPROOF <br />TYP. TYPICAL <br />WS. WEATHER-STRIPPING <br />W.S. WATER STOP <br />W/O WITHOUT <br />H.M. HOLLOW MATERIAL / CORE <br />S.C. SOLID CORE <br />SYMBOL LEGEND <br />APPLICABLE CODES <br /> SINGLE FAMILY DWELLING:1,374 SQ. FT. <br /> COVERED PATIO: <br /> LOT NO: 35 # OF STORIES: 1 <br /> APN: 412-402-35 MAX. BUILDING HEIGHT: 14'-2" <br /> ZONING: R-3 PARKING REQ.: <br /> YEAR BUILT: 1960 TRACT #: TR 3679 <br />PROJECT ADDRESS: 1901 W HALL AVE SANTA ANA, CA 92704 <br />DESIGNER: DDB, LLC <br />SCOPE OF WORK: <br />(E) GARAGE WALLS TO BE DRYWALLED (NO NEW INSULATION) <br />(N) EXTERIOR WATER HEATER ENCLOSURE (TO MATCH EXISTING HOME) <br />(E) COVERED PATIO & SHED TO BE REMOVED. <br />UNPERMITED ELECTRICAL AND PLUMBING WORK TO BE REMOVED FROM GARAGE <br />UNPERMITED DRYWALL TO BE REMOVED FROM GARAGE CEILING <br />OCCUPANCY: R-3 / U <br />CONSTRUCTION TYPE: V-B // NON-FIRE SPRINKLERED <br />PROJECT INFO <br />LEGAL DESCRIPTION: <br />PHONE: 310.487.1613 <br />PROPERTY AREA: <br />EXISTING <br />6,083 SQ. FT. <br />TOTAL (LOT COVERAGE):2,133 SQ. FT. <br />LOT COVERAGE <br />(SFD + PATIO + GARAGE) / PROPERTY AREA 35.06% <br /> FIRE HAZARD SEVERITY ZONE: NO <br />435 SQ. FT. <br />324 SQ. FT. <br /> 2-CAR GARAGE: <br />TOTAL (FLOOR AREA):1,374 SQ. FT. <br />NORTH <br />SITE LOCATION <br />BLDG #102120916 <br /> <br />APPROVALS: <br />PLNG - C. Santana <br />HOLD- 1901 W Hall <br />Ave11/19/2024