My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1834 W Third St & #2,3 - Plan
PBA
>
Building
>
ProjectDox
>
T
>
Third St
>
1834 W Third St
>
1834 W Third St & #2,3 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/13/2025 1:40:34 AM
Creation date
6/5/2025 7:34:24 AM
Metadata
Fields
Template:
Plan
Permit Number
101120601
101120602
101120603
Full Address
1834 W Third St
1834 W Third St Unit# 2
1834 W Third St Unit# 3
Street Number
1834
1834
1834
Street Direction
W
W
W
Street Name
Third
Third
Third
Street Suffix
St
St
St
Unit Number
2
3
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
434
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
1834 W. 3 rd St. <br />Santa Ana CA 92703 <br />Soil Pressure Factors <br />Seismic Factors <br />1.2 <br />SMs: 1.562 <br />SM1: N/A <br />Sos: 1.041 <br />Soi: N/A <br />Earth Pressure Factors <br />4>28 <br />Maximum Dry Density =116.2 y= 104.58 pcf <br />Active Earth Pressure <br />Ka=0.3610334834 <br />Pa=37.7568816939 <br />Passive Earth Pressure <br />At Rest <br />Tc <br />Ss: <br />S1: <br />Cv: <br />Fv <br />Kp= 2.7698261953 <br />Pp=289.6684235044 <br />Kat=0.5305284373 <br />Pat=55.4826639728 <br />8 <br />1.301 <br />0.464 <br />1.36 <br />N/A <br />A full list of Seismic factors is in the Attachment 'G' <br />Soluble Sulfates <br />The results of the limited in-house laboratory tests indicate that the on-site soils tested contain a <br />water-soluble sulfate content of .16 by weight. Based on Table 19 .3 .1.1 of ACI 318-14, the Exposure <br />Class Sl is appropriate for onsite soils. Water cement ratio (0.50) shall be adjusted to produce a low <br />slump ( <3inches>) mix. Concrete specifications may be changed by the Structural Engineer. <br />Type V cement is not required but is recommended for use. Strength should be 4000 psi. <br />Expansive Soil <br />The soil found on this site consists of silty sand. The soil found on the site is expansive. A modified <br />test in the laboratory and the condition of the concrete paving and foundations on site show very low <br />signs of expansive reaction in the soil. Expansion Index: Very low 22 <br />3 <br />Fa <br />PGA:0.553 <br />PGAM:0.663 <br />FPGA:1.2 <br />Ie 1 <br />1834 W Third St & <br />#2,33/21/2025
The URL can be used to link to this page
Your browser does not support the video tag.