Laserfiche WebLink
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01-E <br />Project Name:240051 Calculation Date/Time:2024-07-02T02:25:06-07:00 (Page 12 of 14) <br />Calculation Description:Title 24 Analysis Input File Name:2 STORY MAIN HOUSE + ATTACHED JADU GARAGE Z8.ribd22x <br />Registration Number:Registration Date/Time:    HERS Provider: <br />CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 <br />Schema Version: rev 20220901 <br />Report Generated: 2024-07-02   02:26:25 <br />HVAC - HEAT PUMPS <br />01 02 03 04 05 06 07 08 09 10 11 12 13 <br />Name System Type Number of <br />Units <br />Heating Cooling <br />Zonally <br />Controlled <br />Compressor <br />Type HERS VerificationHeating <br />Efficiency <br />Type <br />HSPF/HS <br />PF2/COP Cap 47 Cap 17 <br />Cooling <br />Efficiency <br />Type <br />SEER/SE <br />ER2 <br />EER/EER <br />2/CEER <br />Heat Pump <br />System 1 VCHP-ductless 1 HSPF 8 17000 13500 EERSEER 14 12 Not Zonal Single <br />Speed <br />Heat Pump System <br />1-hers-htpump <br />Heat Pump <br />System 2 VCHP-ductless 1 HSPF 8 17000 13500 EERSEER 14 12 Not Zonal Single <br />Speed <br />Heat Pump System <br />2-hers-htpump <br />HVAC HEAT PUMPS - HERS VERIFICATION <br />01 02 03 04 05 06 07 08 09 <br />Name Verified Airflow Airflow Target Verified EER/EER2 Verified <br />SEER/SEER2 <br />Verified Refrigerant <br />Charge <br />Verified <br />HSPF/HSPF2 <br />Verified Heating <br />Cap 47 <br />Verified Heating <br />Cap 17 <br />Heat Pump System <br />1-hers-htpump Not Required 0 Not Required Not Required Yes No Yes Yes <br />Heat Pump System <br />2-hers-htpump Not Required 0 Not Required Not Required Yes No Yes Yes <br />VARIABLE CAPACITY HEAT PUMP COMPLIANCE OPTION - HERS VERIFICATION <br />01 02 03 04 05 06 07 08 09 10 <br />Name <br />Certified <br />Low-Static <br />VCHP System <br />Airflow to <br />Habitable <br />Rooms <br />Ductless Units <br />in Conditioned <br />Space <br />Wall Mount <br />Thermostat <br />Air Filter Sizing <br />&amp; Pressure <br />Drop Rating <br />Low Leakage <br />Ducts in <br />Conditioned <br />Space <br />Minimum <br />Airflow per <br />RA3.3 and <br />SC3.3.3.4.1 <br />Certified <br />non-continuous <br />Fan <br />Indoor Fan not <br />Running <br />Continuously <br />Heat Pump System 1 Not required Required Required Required Not required Not required Not required Not required Not required <br />Heat Pump System 2 Not required Required Required Required Not required Not required Not required Not required Not required <br />1834 W Third St & <br />#2,33/21/2025