Laserfiche WebLink
WH <br />W/ <br />D <br />W/D <br />. <br />D <br />2 <br />2. <br />. <br />. <br />. <br />. <br />. <br />. <br />. <br />. <br />GF <br />C <br />I <br />GF <br />C <br />I <br />GFCI GFCIGFCIGFCIGFCI <br />GF <br />C <br />I <br />. <br />42" <br />WP <br />GFI <br />. <br />(N) LIVING <br />(N) VAULTED <br />(N) BATH <br />PA <br />N <br />T <br />R <br />Y <br />(E) BEDROOM <br />(N <br />) <br /> <br />C <br />L <br />O <br />S <br />E <br />T <br />7'-8 1/2" <br />5' <br />- <br />5 <br />" <br />10 <br />' <br />- <br />6 <br />" <br />3' <br />- <br />0 <br />" <br />4' <br />- <br />3 <br />" <br />4' <br />- <br />0 <br />" <br />4'-0" <br />VALETED CEILING <br />3'-0" <br />5' <br />- <br />1 <br />0 <br />" <br />NEW CONCRETE <br />SLAB EXTENSION <br />EXISTING <br />CONCRETE SLAB <br />5' <br />- <br />3 <br /> <br />1 <br />/ <br />2 <br />" <br />7' <br />- <br />2 <br />" <br />(E) FLOOR PLAN (NOT PART OF THE SCOPE) <br />3' <br />- <br />8 <br /> <br />1 <br />/ <br />2 <br />" <br />8' <br />- <br />1 <br />" <br />5' <br />- <br />2 <br /> <br />1 <br />/ <br />2 <br />" <br />4'-9"(N) OPENING TO THE <br />EXISTING WALL <br />20'-1" <br />6' <br />- <br />8 <br /> <br />1 <br />/ <br />2 <br />" <br />6' <br />- <br />8 <br /> <br />1 <br />/ <br />2 <br />" <br />4' <br />- <br />8 <br />" <br />3'-5 1/2"2'-11"8'-6 1/2"4'-4" <br />D06 <br />D02 <br />D62 <br />D03 <br />W40 <br />W274D69 <br />W73 <br />D05 <br />D05 <br />(N) HEAT PUMP <br />WATER HEATER <br />WH <br />(N) <br />22"X30" <br />MIN ATTIC <br />ACCESS <br />2'-7" <br />30" MIN. <br />24 <br />" <br /> <br />M <br />I <br />N <br />N <br />(N)EXISTING <br />CONDENSER UNIT <br />RELOCATION <br />ACAC <br />(N)CONDENSER UNIT <br />ACAC <br />2' <br />- <br />4 <br />" <br />1' <br />- <br />7 <br />" <br />1' <br />- <br />7 <br />" <br />EGRESS DOOR <br />SHALL NOT BE <br />MORE THAN 1 1/2" <br />LOWER THAN THE <br />TOP OF THE <br />THRESHOLD <br />EGRESS DOOR <br />SHALL NOT BE <br />MORE THAN 1 1/2" <br />LOWER THAN THE <br />TOP OF THE <br />THRESHOLD <br />CD <br />OCCUPANT <br />SENSOR <br />MIN. EXHAUST RATE: <br />GAS RANGE 280 CFM <br />ELECTRIC RANGE 160 CFM <br />NO GAS HOOK UP AT STOVE <br />(ELECTRIC RANGE) <br />D06 <br />W40 <br />- <br />--- <br />1 <br />A111 <br />2 <br />A111 <br />IAQ FAN & BATHROOM <br />EXHAUST MIN 50 CFM, <br />MAX. 1 SONES. DUCTED TO <br />OUTSIDE AND CONTROLLED <br />BY HUMIDSTAT. <br />THE FANS STAY ON <br />THE SWITCH IDENTIFYING <br />THIS AS THE WHOLE HOUSE <br />IAQ FAN AND TO RUN AT ALL <br />TIMES THE HOUSE IS OCCUPIED <br />2' <br />- <br />6 <br /> <br />1 <br />/ <br />4 <br />" <br />5' <br />- <br />0 <br />" <br />2' <br />- <br />1 <br />1 <br /> <br />1 <br />/ <br />2 <br />" <br />- <br />--- <br />1 <br />A111 <br />LA <br />N <br />D <br />I <br />N <br />G <br />NOTE: <br />FLOOR PLAN LEGEND <br />ENERGY STAR EXHAUST MIN 50 CFM DUCTED TO <br />OUTSIDE AND CONTROLLED BY HUMIDISTAT <br />SMOKE DETECTOR/CARBON MONOXIDE <br />EXISTING WALL <br />EXTERIOR LIGHT FIXTURE <br />NEW WALL <br />1-HR FIRE RATED WALL <br />LED DOWNLIGHT FIXTURE <br />(E) PROPERTY LINE <br />AFCI DUPLEX <br />GFCI/AFCI DUPLEX <br />WEATHERPROOF GFCI/AFCI DUPLEX <br />AFCI DUPLEX @ 42" ABOVE FINISHED FLOOR <br />ENERGY STAR EXHAUST 100 CFM <br />INSULATION PER T24 <br />*UL U305 FIRE RATING STC <br />5/8" GYPSUM BOARD TYPE X EACH SIDE, SCREW 8" O.C. <br />END JOINTS <br />RESILIENT CLIP AT EA. STUD OR RESILIENT CHANNELS -- <br />ONE SIDE <br />2X WOOD STUD <br />NOTE: <br />1 HOUR SEPARATION GOES FROM FOUNDATION TO THE <br />UNDERSIDE OF THE ROOF SHEATING <br />DATE: <br />CONTRACTOR TO VERIFY ALL DIMENSIONS, <br />CONDITIONS, ETC., PERTAINING TO THE WORK AT <br />THE SITE BEFORE PROCEEDING WITH THE WORK AS <br />INSTRUMENT OF SERVICE, ALL DESIGN, IDEAS AND <br />INFORMATION SHOWN ON THESE DRAWINGS ARE <br />AND SHALL REMAIN THE PROPERTY OF ADU <br />RESOURCE CENTER NO PART THEREOF SHALL BE <br />COPIED, DISCLOSED TO OTHERS, OR USED IN <br />CONNECTION WITH ANY WORK OR PROJECT OTHER <br />THAN THE SPECIFIC PROJECT FOR WHICH THEY <br />HAVE BEEN PREPARED AND DEVELOPED WITHOUT <br />THE WRITTEN CONSENT OF ADU RESOURCE CENTER. <br />VISUAL CONTACT WITH THESE DRAWINGS SHALL <br />CONSTITUTE CONCLUSIVE EVIDENCE OF <br />ACCEPTANCE OF THESE RESTRICTIONS. <br />DRAWN BY: <br />600 N. BRAND BLVD. #560 <br />GLENDALE CA. 91203 <br />(818) 450-8422 <br />ARCHITECTURE@ADURESOURCECENTER.COM <br />12/6/2024 4:23:37 PM <br />A111 <br />EX <br />I <br />S <br />T <br />I <br />N <br />G <br /> <br />S <br />F <br />R <br />CO <br />N <br />V <br />E <br />R <br />S <br />I <br />O <br />N <br /> <br />( <br /> <br />1 <br />4 <br />6 <br />. <br />5 <br />6 <br /> <br />S <br />F <br />) <br />+ <br />A <br />D <br />D <br />I <br />T <br />I <br />O <br />N <br /> <br />( <br />3 <br />3 <br />5 <br />. <br />0 <br />2 <br /> <br />S <br />F <br />) <br />TO <br /> <br />N <br />E <br />W <br /> <br />O <br />N <br />E <br /> <br />S <br />T <br />O <br />R <br />Y <br />AT <br />T <br />A <br />C <br />H <br />E <br />D <br /> <br />A <br />D <br />U <br /> <br />( <br />4 <br />9 <br />1 <br />. <br />0 <br />8 <br />SF <br />) <br />18 <br />0 <br />6 <br /> <br />W <br /> <br />1 <br />5 <br />T <br />H <br /> <br />S <br />T <br />, <br /> <br />U <br />N <br />I <br />T <br /> <br />2 <br />, <br /> <br />S <br />A <br />N <br />T <br />A <br />AN <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />6 <br />PROPOSED 1ST FLOOR PLAN <br />SCALE: 1/4" = 1'-0" <br />PROPOSED 1ST FLOOR PLAN 1 <br /> 12" = 1'-0" <br />1- HOUR EXTERIOR STUCCO WALL <br />No.Description Date <br />DOOR SCHEDULE <br />Type Mark Width Height Count Type Comments U-FACTOR Phase Created Description <br />D02 2' - 8"6' - 8"1 SWING New Construction <br />D03 2' - 8"6' - 8"1 BI-FOLD New Construction <br />D05 2' - 10"8' - 0"2 OPENING New Construction <br />D06 2' - 0"6' - 8"1 CLOSET SWING DOOR New Construction <br />D62 3' - 0"6' - 8"1 SWING 0.2 New Construction <br />D69 5' - 8"6' - 8"1 DOUBLE SWING 0.2 New Construction <br />WINDOW SCHEDULE <br />Type Mark Width Height Head Height Sill Height Count Type Comments Description SHGC U-Factor Phase Created <br />W40 3' - 0"3' - 0"6' - 8"3' - 8"2 HUNG 0.23 0.3 New Construction <br />W73 5' - 0"5' - 0"6' - 8"1' - 8"1 HUNG 0.23 0.3 New Construction <br />W274 5' - 0"3' - 10"6' - 8"2' - 10"1 HUNG 0.23 0.3 New Construction <br />NEWLY CONSTRUCTED DWELLINGS SHALL COMPLY WITH AGING-IN- <br />PLACE AND FALL PREVENTION (CRC R327): <br />1. AT LEAST ONE BATHROOM ON THE ENTRY LEVEL SHALL BE <br />PROVIDED WITH REINFORCEMENT FOR GRAB BARS, WHERE THERE IS <br />NO BATHROOM ON THE ENTRY LEVEL, AT LEAST ONE BATHROOM ON <br />THE SECOND OR THIRD FLOOR OF THE DWELLING SHALL COMPLY WITH <br />CRC R327.1.1. PROVIDE CONSTRUCTION DETAIL SHOWING COMPLIANCE <br />WITH THIS REQUIREMENT. <br />2. ELECTRICAL RECEPTACLE OUTLETS, SWITCHES AND CONTROLS <br />SHALL BE LOCATED NO MORE THAN 48" MEASURED FROM THE TOP OF <br />THE OUTLET BOX AND NOT LESS THAN 15" MEASURED FROM THE <br />BOTTOM OF THE OUTLET BOX ABOVE THE FINISH FLOOR. CRC R327.1.2 <br />3. DOORBELL BUTTONS SHALL NOT BE INSTALLED MORE THAN 48" <br />ABOVE EXTERIOR FLOOR OR LANDING. CRC R327.1.4 <br />INDOOR LIGHTING CONTROLS NOTE: <br />1. ADDS AUTO-OFFCONTROLS FOR LIGHTING IN DRAWERS AND <br />CABINETS <br />2. UNDERSHELF, DISPLAY CABINETS, SWITCHED OUTLETS CONTROLLED <br />SEPARATE FROM CEILING LIGHTING. <br />3. LIGHTING IN HAVITABLE SPACES SHALL HAVE ACCESSIBLE WALL- <br />MOUNTED DIMMING CONTROLS. <br /> 1" = 1'-0" <br />1-HR, FIRE RATING INTERIOR WALL <br />2 <br />1 <br />NOTE: <br />SEE SHEET A304 AND A305 FOR DOOR AND WINDOW SPECIFICATION <br />AGING IN PLACE REQUIREMENTS ON SHEET G005 <br />1806 W 15th St & <br />Unit #25/1/2025