Laserfiche WebLink
4 max <br />100 <br />X <br />³ 8 <br />0 <br />20 <br />3 <br />0 <br />X <br />> <br /> <br />2 <br />7 <br />68 <br />5 <br />MEN <br />6" <br /> <br />M <br />I <br />N <br />. <br />PICTOGRAM <br />FIELD <br />§11B-703.6.1 <br />48" MIN. CLR. <br />36" MIN. CLR. <br />UNREASONABLE <br />HARDSHIP ONLY <br />48" MIN. CLR. <br />36" MIN. CLR. <br />UNREASONABLE <br />HARDSHIP ONLY <br />(TYP.) <br />(TYP.) <br />OBSTRUCTION <br />CURB <br />STREET <br />SIDE WALK SIDE WALK <br />NOTE:-SIDEWALKS SHALL COMPLY WITH CBC §11B-302 & 11B-403.5.1 EXCEPTION 3 <br />(TYP.) <br />(TYP.) <br />CURB <br />STREET <br />32" MIN. CLR. FOR <br />A MAX. OF 24" PER <br />SECTION 11B-403.5.1 <br />EXCEPTION 1 <br />32" MIN. CLR. FOR <br />A MAX. OF 24" PER <br />SECTION 11B-403.5.1 <br />EXCEPTION 1 <br />. <br />. <br />. <br />. <br />THRESHOLD <br />BELOW THRESHOLD <br />A <br />THRESHOLDB <br />C LEVEL CHANGES <br />1 <br />2 <br />1/2"MAX. <br />1/4" MAX. <br />3. <br />2. <br />1. <br />PILE HEIGHT <br />1/2" MAX. <br />COMPRESSED CARPET 1/4" MAX. <br />TRANSITION <br />BETWEEN FLOOR <br />FINISHES <br />FIN. FLOOR <br />LEVEL <br />1/2" MAXIMUM TOTAL HEIGHT WITH 1/4" MAXIMUM VERTICAL CHANGE AT EDGE. <br />1 : 2 SLOPED BEVEL REQUIRED IF LEVEL CHANGE IS OVER 1/4" VERITCAL LEVEL CHANGE. <br />1/4" MAXIMUM VERTICAL LEVEL CHANGE. <br />NOTE:-TRANSITIONS SHALL COMPLY WITH CBC §11B-302, 11B-303, & 11B-404.2.5 <br />NOTES: <br />1/ <br />4 <br />" <br />MA <br />X <br />. <br />. <br />DETAILB <br />HANDLE <br />OR U SHAPED <br />34" TO 44" LEVER <br />DETAILA <br />3. <br />2. <br />1. <br />1. <br />HARDWARE: <br />DOOR AND GATES: <br />PROVIDE A SMOOTH SURFACE <br />WITHIN 10" OF THE FINISH FLOOR <br />10 <br />" <br />PROVIDE A SMOOTH SURFACE WITHIN 10" OF THE <br />FINISH FLOOR. EXCEPTIONS: <br />A.TEMPERED GLASS DOORS WITHOUT STILES AND <br />HAVING A BOTTOM RAIL OR SHOE WITH THE <br />TOP LEADING EDGE TAPERED AT 60 DEGREES <br />MINIMUM FROM THE HORIZONTAL <br />B.DOORS AND GATES THAT DO NOT EXTEND TO <br />WITHIN 10 INCHES OF THE FINISH FLOOR OR <br />GROUND <br />OPENABLE BY SINGLE EFFORT <br />LEVER-TYPE DEVICE (NOT <br />REQUIRING GRASPING). <br />MOUNTED 34" TO 44". <br />MAXIMUM 5 LBS. EFFORT TO OPERATE <br />EXTERIOR DOOR AND 5 LBS. FOR <br />INTERIOR. SEE EXCEPTION FOR FIRE <br />DOORS <br />OPENABLE FROM INSIDE WITHOUT USE OF KEY <br />OR SPECIAL KNOWLEDGE OR EFFORT. <br />NOTE: -DOORS SHALL COMPLY WITH CBC §11B-404 <br />FLOOR SURFACE <br />PROVIDE A <br />SMOOTH SURFACE <br />WITHIN 10" OF THE <br />FINISH FLOOR <br />2. <br />15 <br />" <br />MI <br />N <br />. <br />48 <br />" <br /> <br />M <br />A <br />X <br />. <br />48 <br />" <br /> <br />M <br />A <br />X <br />. <br />20" MAX. <br />30 <br />" <br />48"48" <br />30 <br />" <br />48 <br />" <br />M <br />A <br />X <br />. <br />15 <br />" <br /> <br />M <br />I <br />N <br />. <br />46 <br />" <br /> <br />M <br />A <br />X <br />. <br />34 <br />" <br /> <br />M <br />A <br />X <br />. <br />> 10"-24" <br />MAX. <br />DAC <br />FE <br />10" <br />MAX. <br />34 <br />" <br /> <br />M <br />A <br />X <br />. <br />10" <br />MAX. <br />48 <br />" <br /> <br />M <br />A <br />X <br />. <br />NOTES: <br />1. FOR PARALLEL APPROACH, ACCESSIBLE PORTION OF SERVICE COUNTER TO BE 36" IN LENGTH AND 34" MAX HEIGHT. <br />B HIGH AND LOW <br />FORWARD REACH <br />LIMITS <br />HIGH AND LOW <br />SIDE REACH <br />LIMITS <br />44 <br />" <br /> <br />M <br />A <br />X <br />. <br />> 20" - 25" MAX. <br />MAXIMUM FORWARD REACH <br />OVER AN OBSTRUCTION <br />MAXIMUM SIDE REACH <br />OVER AN OBSTRUCTION <br />CLEAR FLOOR <br />SPACE PARALLEL <br />APPROACH <br />CLEAR FLOOR <br />SPACE FRONT <br />APPROACH <br />DOOR WIDTH <br />DOOR WIDTH PLUS <br />18" MIN. INTERIOR <br />24" MIN. EXTERIOR <br />SIDE OF DOOR <br />VA <br />R <br />I <br />E <br />S <br />, <br /> <br />4 <br />4 <br />" <br /> M <br />I <br />N <br />. <br /> <br />- <br /> <br />D <br />E <br />P <br />E <br />N <br />D <br />S <br />ON <br /> <br />A <br />P <br />P <br />R <br />O <br />A <br />CH <br /> <br />D <br />I <br />R <br />E <br />C <br />T <br />I <br />O <br />N <br />60 <br />" <br /> <br />M <br />I <br />N <br />. <br />32" CLR. MIN.. <br />. <br />48 <br />" <br /> <br />M <br />I <br />N <br />. <br />DOOR WIDTH PLUS 42" <br />. <br />DO <br />O <br />R <br /> <br />W <br />I <br />D <br />T <br />H <br />P <br />L <br />U <br />S <br /> <br />4 <br />2 <br />" <br />48" MIN. CLR. <br />32" <br />MIN. CLR. <br />48 <br />" <br /> <br />M <br />I <br />N <br />. <br /> <br />C <br />L <br />R <br />. <br />G <br />FVESTIBULE PLANEC <br />18" MIN. <br />A SINGLE DOOR <br />32" CLEAR <br />B DOUBLE DOOR <br />32" CLEAR <br />90° <br />D <br />60 <br />" <br /> <br />M <br />I <br />N <br />. <br />. <br />18" MIN. <br />24" MIN. AT <br />EXT. SIDE OF <br />EXT. DOOR <br />18" MINIMUM BEYOND STRIKE EDGE OF <br />A GATE OR DOOR, TYP. 24" MIN. AT <br />THE EXT. SIDE OF EXT. GATE OR <br />DOORS <br />NOTES:-DOORS AND DOOR CLEARANCES SHALL COMPLY WITH CBC §11B-404 <br />-REQUIRED DOOR CLEAR SPACE SHALL NOT SLOPE STEEPER THAN 1:48 IN ANY DIRECTION <br />-DOORS SHALL NOT SWING INTO THE CLEAR FLOOR OR CLEARANCE AREA FOR ANY FIXTURE <br />-DOORS SHALL BE PERMITTED TO SWING INTO TURNING SPACES §11B-304.4, EXCEPT AT <br />TOILET ROOMS WHERE THE MAXIMUM ENCROACHMENT IS 12" §11B-603.2.3 <br />18" MIN. INTERIOR <br />24" MIN. EXT. SIDE <br />OF EXT. DOOR <br />REQUIRED CLEAR <br />SPACE ADD'L 12" MIN. <br />IF DOOR HAS <br />BOTH LATCH <br />AND CLOSER <br />GENERAL PLAN FOR FRONT <br />APPROACH <br />DOOR IN RECESS <br />60 <br />" <br /> <br />M <br />I <br />N <br />. <br />. <br />18" MIN. <br />24" MIN. AT <br />EXT. SIDE OF <br />EXT. DOOR <br />REQUIRED CLEAR <br />SPACE <br />FOR FRONT APPROACH <br />REQUIRED CLEAR SPACE <br />FOR FRONT APPROACH <br />REQUIRED CLEAR SPACE <br />RAMP LANDING AT <br />DOORWAY PLAN <br />DOORS IN SERIES <br />48 <br />" <br /> <br />M <br />I <br />N <br />. <br />48 <br />" <br /> <br />M <br />I <br />N <br />. <br />H MANEUVERING CLEARANCES (CONT.) <br />MIN. DOOR CLEAR SPACE <br />60" MIN. <br />18 <br />" <br /> <br />M <br />I <br />N <br />. <br />24 <br />" <br /> <br />@ <br /> <br />E <br />X <br />T <br />. <br /> <br />O <br />F <br />EX <br />T <br />. <br /> <br />D <br />O <br />O <br />R <br />MIN. DOOR CLEAR SPACE <br />48" MIN. <br />12 <br />" <br />PROVIDE ADD'L 12" <br />WHEN DOOR HAS <br />BOTH A LATCH & <br />CLOSER <br />FRONT APPROACH <br />PULL SIDE PUSH SIDE <br />MIN. DOOR CLEAR SPACE <br />MIN. DOOR CLEAR <br />SPACE <br />60" MIN. <br />48" WHEN DOOR HAS <br />BOTH LATCH & CLOSER <br />44" TYP. <br />PROVIDE ADD'L 4" <br />WHEN DOOR HAS BOTH <br />A LATCH & CLOSER <br />HINGE APPROACH <br />PULL SIDE PUSH SIDE <br />MIN. DOOR CLEAR SPACE <br />36 <br />" <br /> <br />M <br />I <br />N <br />. <br />22 <br />" <br /> <br />M <br />I <br />N <br />. <br />MIN. DOOR CLEAR <br />SPACE <br />48" WHEN DOOR HAS <br />BOTH LATCH & CLOSER <br />44" TYP. <br />60" MIN. <br />PROVIDE ADD'L 4" <br />WHEN DOOR HAS BOTH <br />A LATCH & CLOSER <br />24 <br />" <br /> <br />M <br />I <br />N <br />. <br />LATCH APPROACH <br />PULL SIDE PUSH SIDE <br />24 <br />" <br /> <br />M <br />I <br />N <br />. <br />MIN. CLEAR SPACE <br />42" MIN.48" MIN. <br />MIN. CLEAR SPACE <br />DOORWAY (NO DOOR) <br />SIDE APPROACHFRONT APPROACH <br />MIN. DOOR CLEAR <br />SPACE <br />32 <br />" <br /> <br />M <br />I <br />N <br />. <br /> <br />C <br />L <br />R <br />. <br />MIN. DOOR CLEAR <br />SPACE <br />42" MIN. <br />22 <br />" <br /> <br />M <br />I <br />N <br />. <br />42" MIN. <br />24 <br />" <br /> <br />M <br />I <br />N <br />. <br />SLIDING DOOR (POCKET DOOR) <br />POCKET OR HINGE APPROACH STOP OR LATCH APPROACH <br />.VA <br />R <br />I <br />E <br />S <br />, <br /> <br />4 <br />4 <br />" <br /> M <br />I <br />N <br />. <br /> <br />- <br /> <br />D <br />E <br />P <br />E <br />N <br />D <br />S <br />ON <br /> <br />A <br />P <br />P <br />R <br />O <br />A <br />CH <br /> <br />D <br />I <br />R <br />E <br />C <br />T <br />I <br />O <br />N <br />FOR FRONT APPROACH <br />REQUIRED CLEAR SPACE <br />12" MIN. <br />RECESS 8" DEEP OR LESS RECESS OVER 8" DEEP <br />. <br />VA <br />R <br />I <br />E <br />S <br />, <br /> <br />4 <br />4 <br />" <br /> M <br />I <br />N <br />. <br /> <br />- <br /> <br />D <br />E <br />P <br />E <br />N <br />D <br />S <br />ON <br /> <br />A <br />P <br />P <br />R <br />O <br />A <br />CH <br /> <br />D <br />I <br />R <br />E <br />C <br />T <br />I <br />O <br />N <br />FOR FRONT <br />APPROACH REQUIRED <br />CLEAR SPACE <br />12" MIN. <br />PROVIDE ADD'L 12" <br />WHEN DOOR HAS <br />BOTH A LATCH & <br />CLOSER <br />OBSTRUCTION <br />PERMITTED WHEN <br />DOOR DOES NOT <br />HAVE A LATCH OR <br />DOES NOT HAVE A <br />CLOSER <br />8" <br /> <br />O <br />R <br /> <br />L <br />E <br />S <br />S <br />MO <br />R <br />E <br /> <br />T <br />H <br />A <br />N <br /> 8 <br />" <br />SIGNAGE <br />TITLE <br />NOTE:-SIGNS SHALL COMPLY WITH CBC §11B-703 <br />-REFER TO DETAIL 11 FOR ADDITIONAL INFORMATION <br />- REFER TO TITLE 24 ADA ACCESSIBILITY REQUIREMENTS NOTES SHEET 1 FOR ADD'L INFORMATION <br />ACCESSIBLE <br />NOTE:-SIGNS SHALL COMPLY WITH CBC §11B-703 <br />-REFER TO DETAIL 11 & 16 FOR ADDITIONAL INFORMATION <br />- REFER TO TITLE 24 ADA ACCESSIBILITY REQUIREMENTS NOTES SHEET 2 FOR ADD'L INFORMATION <br />§ <br />NOTE:-SIGNS SHALL COMPLY WITH CBC §11B-703.1, 11B-703.2, 11B-703.3, & 11B-703.5 <br />-REFER TO DETAIL 11 & 16 FOR ADDITIONAL INFORMATION <br />- REFER TO TITLE 24 ADA ACCESSIBILITY REQUIREMENTS NOTES SHEET 2 FOR ADD'L INFORMATION <br />NOTE:-SIGNS SHALL COMPLY WITH CBC §11B-703 <br />-REFER TO DETAIL XX & XX FOR ADDITIONAL INFORMATION <br />- REFER TO TITLE 24 ADA ACCESSIBILITY REQUIREMENTS NOTES SHEET 2 FOR ADD'L INFORMATION <br />§ <br />TRANSFER <br />SIDE <br />112"Ø GRAB BAR, <br />TYP. W/ PEENED <br />FINISH & 250 <br />LBS. CAP. <br />FEMININE NAPKIN <br />DISPOSAL, WHERE <br />OCCURS <br />TOILET TISSUE <br />DISPENSER <br />(WITHOUT STOPS)WATER CLOSET, TYP. <br />MEASURED TO TOP <br />OF TOILET SEAT <br />TO BOTTOM EDGE OF <br />REFLECTING SURFACE <br />INSULATE WASTE PIPE, <br />TYP. <br />24" <br />NOTE: <br />- <br />REQUIREMENTS SHALL COMPLY WITH CBC §11B-306, 11B-309, 11B-602, 11B-604, 11B-605, 11B-606, 11B-609, AND 11B-902 <br />REFER TO TITLE 24 ADA ACCESSIBILITY REQUIREMENTS, NOTES SHEET 1 FOR ADDITIONAL INFORMATION <br />2' <br />- <br />4 <br />" <br />± <br />17" MIN. <br />25" MAX. <br />11" MIN. <br />8" MIN. <br />17 <br />" <br /> <br /> <br />M <br />I <br />N <br />. <br />19 <br />" <br /> <br />M <br />A <br />X <br />. <br />TOILET SEAT <br />HEIGHT <br />WATER CLOSET, <br />TYP. <br />19 <br />" <br /> <br />M <br />I <br />N <br />40 <br />" <br /> <br />M <br />A <br />X <br />. <br />URINAL <br />SCREEN <br /> OF <br />HANDLE <br />17" MIN. TO 19" MAX. @ <br />AMBULATORY STALLS <br />EXIT <br />SURFACE MOUNTED <br />- SOAP DISPENSER <br />TOILET SEAT COVER <br />DISPENSER - RECESSED <br />MULTI-ROLL TOILET <br />TISSUE DISPENSER <br /> RECESSED - PAPER <br />TOWEL DISPENSER <br />TYP. <br /> SEAT COVER & TOILET <br />TISSUE DISPENSER <br />SANITARY NAPKIN <br />DISPOSAL <br /> SEAT COVER, TOILET <br />TISSUE & SANITARY NAPKIN <br />DISPENSER <br />GRAB BARS <br />HAND DRYER VENDING <br />MACHINE <br />EMERGENCY TELEPHONE W <br />/ SCREAM ALERT <br />KOALA KARE DIAPER <br />CHANGING STATION <br />KOALA KARE <br />CHILD HARNESS <br />NOTE: REFER TO DETAIL 3 FOR <br />ADD'L INFO. <br />ALL IN ONE PAPER TOWEL <br />DISPENSER / TRASH <br />RECEPTACLE <br />SIDE ELEVATION OF URINAL <br />42" MIN.12" <br />MAX. <br />19 <br />" <br /> <br />M <br />I <br />N <br />. <br />24" MIN. <br />7" MIN. <br />9" MAX. <br />SIDE ELEVATION OF WATER CLOSET <br />MIN. <br />MAX. <br />6" <br />12" <br />FLUSH VALVE <br />HANDLE SHALL <br />BE ON SIDE <br />AWAY FROM <br />WALL (WIDE <br />SIDE), TYP. <br />MIN. <br />17" MIN. <br />18" MAX. <br />FRONT ELEVATION OF WATER CLOSET <br />GRAB BAR, <br />TYP. <br />9" <br /> <br />M <br />I <br />N <br />. <br />SIDE ELEVATION OF LAVATORY <br />36" MIN. <br />TOILET - <br />STANDARD <br />TOILET - CHILD <br />12" HIGH TYP. <br />TOILET - <br />ACCESSIBLE <br />DRINKING <br />FOUNTAIN <br />URINAL - STANDARD / <br />ACCESSIBLE <br />URINAL - CHILD / <br />ADA COMPLIANT <br />LAVATORY - <br />ACCESSIBLE <br />TOTO <br />TOTO <br />SCALE <br />NTS1 NOT USED 7 SCALE <br />NTS <br />9 SCALE <br />NTS <br />10 SCALE <br />NTS <br />SCALE <br />NTS11 SCALE <br />NTS12 13 SCALE <br />NTS <br />SCALE <br />NTS <br />SCALE <br />NTS14 15 <br />SCALE <br />NTS16 <br />GENDER NEUTRAL <br />SYMBOL <br />1'-0 <br />" <br />1'-0 <br />" <br />MEN'S RESTROOM <br />SYMBOL <br />1' <br />- <br />0 <br />" <br />1' <br />- <br />0 <br />" <br />1'-0" <br />NOTES: <br />1.SIGNS SHALL HAVE 1 <br />4" THICK TRIANGLE SUPER <br />IMPOSED ON 1 <br />4" THICK CIRCLE. <br />2.INSTALL 58"-60" ABOVE FINISHED FLOOR. <br />MEASURED FROM HORIZONTAL CENTERLINE <br />OF THE SYMBOL. AND WITHIN 1 INCH OF THE <br />VERTICAL CENTERLINE OF THE DOOR. <br />LEGEND: <br />BLACK <br />PEARL GREY <br />PICTOGRAMS <br />19 SCALE <br />NTS <br />SCALE <br />NTS20 SCALE <br />NTS <br />SCALE <br />NTS 232221SCALE <br />NTSACCESS. SURFACE IDENT. <br />LEGEND: <br />BLUE <br />WHITE <br />B <br />A <br />SCALE <br />NTS <br />SCALE <br />NTS2417 SCALE <br />NTS25 SCALE <br />NTS <br />SCALE <br />NTS2829SCALE <br />NTS26 SCALE <br />NTS27 <br />90° <br />SCALE <br />NTS2 ACCESSIBLE DOOR AND GATE CLEARANCES <br />H MANEUVERING CLEARANCES <br />3 SCALE <br />NTS <br />6 SCALE <br />NTS ACCESSIBLE TRANSITIONS <br />NOT USED 4 SCALE <br />NTS RESTROOM DOORS SYMBOLS 5 SCALE <br />NTS ACCESSIBLE SIGNAGE <br />ACC. SIGN REQUIREMENTS 8 SCALE <br />NTS TACTILE EGRESS SIGN <br />SIDEWALK CLEARANCE <br />NOT USED <br />DOOR AND GATE REQUIREMENTS ACCESS. REACH REQUIREMENTS NOT USED <br />WOMEN'S RESTROOM <br />SYMBOL <br />TOILET SEAT <br />COVER DISPENSER <br />(WHERE OCCURS) <br />TOILET SEAT COVER <br />DISPENSER - RECESSED <br />MULTI-ROLL TOILET <br />TISSUE DISPENSER <br /> SEAT COVER & TOILET <br />TISSUE DISPENSER <br />SANITARY NAPKIN <br />DISPOSAL <br /> SEAT COVER, TOILET <br />TISSUE & SANITARY NAPKIN <br />DISPENSER <br />GRAB BARS <br />FIXTURE MOUNTING DIMENSIONS <br />REFLECTORIZED SIGN PANEL MIN. OF 16 GA. <br />GALV. STL. W/ PORCELAIN ENAMEL FIN. WHITE <br />LETTERING ON BLUE FIELD BEADED <br />REFLECTORIZED TEXTURE. COLOR #15090 FED. <br />STANDARD 595B. INTERNATIONAL SYMBOL <br />ACCESSIBILITY SIGN W/ LETTERING NO LESS <br />THAN 1" HIGH. BOLTED TO GLAV. 2" SQ. STEEL <br />POST <br />CONTRACTOR SHALL CONTACT THE <br />APPROPRIATE AUTHORITY HAVING <br />JURISDICTION, OBTAIN REQUIRED <br />INFORMATION, AND SHALL HAVE THE BLANK <br />SPACES FILLED-IN AS A PERMANENT PART <br />OF THE SIGN <br />2" SQ. GALV. POST SET IN MIN. 18" <br />DEEP CONC. 24" FOOTING <br />NOTE: - PARKING STALL ADDITIONAL SIGNAGE SHALL COMPLY WITH CBC §11B-502.8 <br /> - THIS SIGN SHALL BE PLACED: <br /> 1) IN A CONSPICUOUS PLACE AT EACH ENTRANCE TO AN OFF-STREET PARKING FACILITY OR <br /> 2) IMMEDIATELY ADJACENT TO ON-SITE ACCESSIBLE PARKING AND VISIBLE FROM EACH PARKING SPACE. <br />17" MINIMUM <br />22 <br />" <br /> <br />M <br />I <br />N <br />I <br />M <br />U <br />M <br />80 <br />" <br /> <br />M <br />I <br />N <br />. <br /> <br />F <br />R <br />E <br />E <br /> <br />S <br />T <br />A <br />N <br />D <br />I <br />N <br />G <br />60 <br />" <br /> <br />M <br />I <br />N <br />. <br /> <br />F <br />O <br />R <br /> <br />W <br />A <br />L <br />L <br /> <br />M <br />O <br />U <br />N <br />T <br />E <br />D <br />REFLECTORIZED SIGN PANELMIN. OF 16GA. <br />GALV. STL W/ PORCELAIN ENAMEL FINISH <br />WHITE IMAGE ON BLUE FIELD BEADED <br />REFLECTORIZED TEXTURE. COLOR #15090 <br />FED. STANDARD 595B. INTERMATIONAL <br />SYMBOL ACCESSIBILITY SIGN W/ LETTERING <br />NO LESS THAN 1" HIGH BOLTED TO GALV. <br />STL PIPE <br />11/2"Ø GLAV. STEEL PIPE <br />5" STD. CONC. FILLED STEEL PIPE SET IN <br />CONC. FOOTING, PAINT TRAFFIC YELLOW <br />FINISH SURFACE <br />CONCRETE FOOTING <br />PROVIDE ADD'L. <br />"VAN ACCESSIBLE" <br />TEXT AT VAN <br />STALLS <br />MINIMUM <br />$250 FINE <br />ACCESSIBLE <br />PARKING <br />MINIMUM <br />$250 FINE <br />ACCESSIBLE <br />PARKING <br />VAN <br />ACCESSIBLEPICTOGRAM SHALL BE A <br />MINIMUM OF 6" HIGH <br />PROVIDE MINIMUM FINE <br />TEXT ON SIGN <br />SIGN SHALL BE <br />A MINIMUM OF <br />70 SQUARE <br />INCHES <br />SLOPE TOP1/2" FOR DRAINAGE <br />NOTE: - PARKING STALL SIGNAGE SHALL COMPLY WITH CBC §11B-502.6 & 11B-703 <br /> - A PARKING SPACE IDENTIFICATION SIGN SHALL BE VISIBLE FROM EACH PARKING SPACE. SIGNS SHALL BE PERMANENTLY <br />POSTED EITHER IMMEDIATELY ADJACENT TO THE PARKING SPACE OR WITHIN THE PROJECTED PARKING SPACE WIDTH AT <br />THE HEAD END OF THE PARKING SPACE. SIGNS MAY ALSO BE PERMANENTLY POSTED ON A WALL AT THE INTERIOR END OF <br />THE PARKING SPACE <br />18" <br />3' <br />- <br />0 <br />" <br /> <br />N <br />. <br />T <br />. <br />S <br />. <br />80 <br />" <br /> <br />M <br />I <br />N <br />. <br /> <br />T <br />O <br /> <br />U <br />N <br />D <br />E <br />R <br />S <br />I <br />D <br />E <br /> <br />O <br />F <br /> <br />S <br />I <br />G <br />N <br /> <br />( <br />P <br />O <br />S <br />T <br /> <br />M <br />O <br />U <br />N <br />T <br />E <br />D <br />) <br />60 <br />" <br /> <br />M <br />I <br />N <br />. <br /> <br />F <br />O <br />R <br /> <br />A <br /> <br />W <br />A <br />L <br />L <br /> <br />M <br />O <br />U <br />N <br />T <br />E <br />D <br /> <br />S <br />I <br />G <br />N <br />ST <br />E <br />E <br />L <br /> <br />P <br />I <br />P <br />E <br /> <br />A <br />N <br />D <br /> <br />F <br />O <br />O <br />T <br />I <br />N <br />G <br /> <br />D <br />O <br />E <br />S <br /> <br />N <br />O <br />T <br />OC <br />C <br />U <br />R <br /> <br />W <br />H <br />E <br />N <br /> <br />S <br />I <br />G <br />N <br /> <br />I <br />S <br /> <br />W <br />A <br />L <br />L <br /> <br />M <br />O <br />U <br />N <br />T <br />E <br />D <br />1' <br />- <br />0 <br />" <br />7" <br />2' <br />- <br />6 <br />" <br />6" <br />1' <br />- <br />2 <br />" <br />7" <br />REFLECTORIZED SIGN PANEL MIN. OF 16GA. <br />GALV. STL W/ PORCELAIN ENAMEL FINISH WHITE <br />IMAGE ON BLUE FIELD BEADED REFLECTORIZED <br />TEXTURE. COLOR #15090 FED. STANDARD 595B. <br />INTERMATIONAL SYMBOL ACCESSIBILITY SIGN W/ <br />LETTERING NOT LESS THAN5/8" HIGH BOLTED TO <br />GALV. STL <br />PIPE <br />1 1/2 " Ø GLAV. STEEL PIPE <br />CONTRACTOR HAS THE OPTION TO <br />USE A PRE-SET SLEEVE AND FILL <br />SOLID W/ GROUT <br />FINISH SURFACE <br />CONCRETE FOOTING WALL MOUNTED <br />FINISH <br />SURFACE <br />NOTE:-DIRECTIONAL SIGNAGE SHALL COMPLY WITH CBC §11B-703 <br />SLOPE TOP 1/2" FOR DRAINAGE <br />ACCESSIBLE <br />ROUTE <br />ACCESSIBLE <br />ROUTE <br />1'-0" <br />1' <br />- <br />6 <br />" <br />40 <br />" <br /> <br />M <br />I <br />N <br />. <br /> <br />T <br />O <br /> <br />B <br />O <br />T <br />T <br />O <br />M <br /> <br />O <br />F <br /> <br />S <br />I <br />G <br />N <br />1' <br />- <br />0 <br />" <br />7" <br />40 <br />" <br /> <br />M <br />I <br />N <br />. <br /> <br />T <br />O <br /> <br />B <br />O <br />T <br />T <br />O <br />M <br /> <br />O <br />F <br /> <br />S <br />I <br />G <br />N <br />1' <br />- <br />0 <br />" <br />7" <br />REFER TO DETAIL 28 <br />FOR ACCESS AISLE <br />REQUIREMENTS <br />NOTE: - PASSENGER DROP-OFF AND LOADING ZONES SHALL COMPLY WITH CBC §11B-503 <br /> - THE PARKING STALL AND ACCESS AISLE SHALL HAVE A MAXIMUM SLOPE OF 2% IN ANY DIRECTION (§11B-502.3 & 11B-302) <br /> - ACCESS AISLE SHALL ADJOIN AN ACCESSIBLE ROUTE AND SHALL NOT OVERLAP THE VEHICULAR WAY <br /> - ACCESS AISLE SHALL BE AT THE SAME LEVEL AS THE VEHICLE PULL-UP SPACE THEY SERVE <br /> - ACCESS AISLE, PULL-UP SPACES THEY SERVE, AND THE VEHICULAR ROUTE TO THE LOADING ZONE SHALL HAVE A MINIMUM <br />VERTICAL CLEARANCE OF 114 INCHES (9'-6") §11B-503.5 <br />9' <br />- <br />0 <br />" <br />5' <br />- <br />0 <br />" <br /> <br />M <br />I <br />N <br />. <br />20'-0" MINIMUM <br />36" <br />O.C. <br />-ROUTE OF TRAVEL <br />-PASS. DROP-OFF AND <br />LOADING ZONE <br />A -PARKING STALL <br />ACCESS AISLEB <br />4" WIDE DIAGONAL STRIPING AT <br />3'-0" O.C. MAX., TWO COATS (TYP) <br />COLOR TO BE WHITE OR BLUE <br />REFLECTIVE HIGHWAY PAINT <br />ALL PRIMARY AND CROSS SLOPE <br />CONDITIONS SHALL COMPLY WITH <br />ACCESSIBLE ROUTE OF TRAVEL PER <br />§11B-206 & 11B DIVISION 4 <br />NOTE:-ACCESSIBLE PATH AND ACCESS AISLE SHALL COMPLY WITH §11B-206, 11B DIVISION 4, AND 11B-502.3 <br />PERIMETER 4" WIDE STRIPING, TWO <br />COATS (TYP) COLOR TO BE BLUE <br />REFLECTIVE HIGHWAY PAINT <br />PAINT "NO PARKING", MIN. 12" HIGH <br />LETTERS W/ (2) COATS OF <br />4'-0" MIN. TYP. <br />5'-0" MIN. @ <br />LOADING ZONE <br />36"MAX. <br />(TY <br />P) <br />5'-0" MIN. <br />TYP. <br />36"MAX.(TY <br />P) <br />8" <br />MA <br />X <br />. <br />PARKING <br />NO <br />TRUNCATED DOME PLAN VIEWTRUNCATED DOME SPACINGTRUNCATED DOME SECTION <br /> - DETECTABLE WARNINGS SHALL COMPLY CBC §11B-247 & 11B-705 <br />- REFER TO TITLE 24 ADA REQUIREMENTS NOTES SHEET 1 FOR ADDITIONAL INFORMATION <br />- DETECTABLE WARNINGS AT CURB RAMPS SHALL SHALL BE LOCATED SO THAT THE NEAREST EDGE OF THE CURB <br /> IS 6" MIN. AND 8" MAXIMUM FROM THE LINE AT THE FACE OF THE CURB MARKING THE TRANSITION BETWEEN THE <br />CURB AND THE GUTTER, STREET, OR HIGHWAY. (EXCEPT AT PARALLEL CURB RAMPS) <br />- COLOR: DETECTABLE WARNING SURFACES SHALL BE YELLOW PER FS 33538, FEDERAL STANDARD 595C. EXCEPT <br />THAT DETECTABLE SURFACES AT CURB RAMPS, ISLANDS, AND CUT-THROUGH MEDIANS DO NOT NEED TO COMPLY. <br />- DETECTABLE WARNING SURFACE SHALL CONTRAST WITH THE ADJACENT WALKING SURFACE <br />MI <br />N <br />. <br /> <br />3 <br />' <br />- <br />0 <br />" <br /> <br />T <br />Y <br />P <br />. <br />SE <br />E <br /> <br />P <br />L <br />A <br />N <br />S <br /> <br />F <br />O <br />R <br /> <br />D <br />E <br />P <br />T <br />H <br />2. <br />3 <br />" <br />- <br />2 <br />. <br />4 <br />" <br />2.3"-2.4" <br />0. <br />1 <br />8 <br />" <br />- <br />0 <br />. <br />2 <br />2 <br />" <br />WIDTH AS OCCURS - SEE PLANS <br />0.45"-0.47" <br />0.9"-0.92" <br />0. <br />6 <br />5 <br />" <br />MI <br />N <br />. <br />A <br />B C D <br />E F <br />SINGLE STANDARD ACCESSIBLE PARKING STALL CONFIGURATION <br />AND BASIC ACCESSIBLE STALL REQUIREMENTS <br />ACCESSIBLE <br />PARKING STALL IN <br />PARKING FIELD <br />DUAL REGULAR <br />ACCESSIBLE PARKING <br />STALL CONFIGURATION <br />SINGLE VAN ACCESSIBLE <br />PARKING STALL <br />CONFIGURATION <br />SINGLE VAN AND REGULAR <br />ACCESSIBLE PARKING STALL <br />ALTERNATE CONFIGURATION <br />SINGLE VAN AND REGULAR <br />PARKING STALL <br />CONFIGURATION <br />SIDE SLOPE <br />1:10 MAX. <br />TOP OF EDGE OF CURB <br />AT ACCESSIBLE RAMP <br />SHALL BE FLUSH WITH <br />THE DRIVEWAY PAVING <br />TAPER CURB ON BOTH <br />SIDES OF ACCESSIBLE <br />RAMP <br />4" WIDE STRIPING, <br />TWO COATS (TYP) <br />COLOR TO MATCH <br />EXISTING SITE <br />STRIPING COLOR <br />CONCRETE SIDEWALK <br />BROOM FINISH CONCRETE <br />CURB <br />A.6.2 <br />- <br />-- <br />SIDE SLOPE <br />1:10 MAX. <br />RA <br />M <br />P <br /> <br />S <br />L <br />O <br />P <br />E <br />1: <br />1 <br />2 <br /> <br />M <br />A <br />X <br />. <br />20 <br />-- <br />PAINT "NO PARKING", <br />MIN. 12" HIGH LETTERS <br />W/ (2) COATS OF <br />TRAFFIC WHITE <br />REFER TO DETAIL 11 FOR <br />ACCESS AISLE <br />REQUIREMENTS <br />AN AN ACCESSIBLE <br />STALL, PROVIDE 4" <br />WIDE STRIPING WITH <br />(2) COATS OF <br />TRAFFIC BLUE, TYP. <br />STALL SIGN SHALL PLACED <br />AT THE END OF AND MAY <br />PROJECT INTO THE STALL AT <br />THE STALL'S CENTERLINE <br />NOTE: - PARKING STALLS SHALL COMPLY WITH CBC §11B-208 AND 11B-502 <br /> - THE PARKING STALL AND ACCESS AISLE SHALL HAVE A MAXIMUM SLOPE OF 2% IN ANY DIRECTION (§11B-502.4) <br /> - THE ACCESSIBLE STALL ACCESS AISLE MAY BE ON EITHER SIDE OF THE ACCESSIBLE STALL (§11B-502.3.4) <br />9'-0" ACCESSIBLE 5'-0"PER SITE PLAN <br />4'-6"4'-6" <br />36" <br /> <br />( <br />T <br />YP) <br />18 <br />' <br />- <br />0 <br />" <br /> <br />( <br />M <br />I <br />N <br />) <br />6' <br />- <br />0 <br />" <br /> <br />( <br />T <br />Y <br />P <br />) <br />8" <br /> <br />M <br />A <br />X <br />. <br />9'-0"5'-0"9'-0" <br />18 <br />' <br />- <br />0 <br />" <br />9'-0"8'-0"PER SITE PLAN <br />18 <br />' <br />- <br />0 <br />" <br />12'-0"5'-0"9'-0" <br />18 <br />' <br />- <br />0 <br />" <br />48 <br />" <br /> <br />M <br />I <br />N <br />. <br />9'-0"8'-0"9'-0" <br />18 <br />' <br />- <br />0 <br />" <br />2' <br />- <br />0 <br />" <br />4' <br />- <br />3 <br />" <br /> <br />M <br />I <br />N <br />. <br />9'-0"ACCESS <br />AISLE <br />18 <br />' <br />- <br />0 <br />" <br />NO <br />PARKING <br />NO <br />PARKING NO PARKING <br />NO <br />PARKING <br />A <br />B C D <br />E <br />VAN ACCESSIBLE EVCS STALL <br />CONFIGURATION WITH ADJACENT <br />NON-REGULATED CHARGING STALL <br />AMBULATORY EVCSSTALL <br />CONFIGURATION <br />PARALLEL EVCS <br />STALL CONFIGURATION <br />SINGLE STANDARD ACCESSIBLE EVCS STALL <br />CONFIGURATION AND BASIC STALL REQUIREMENTS <br />IDENTIFICATION SIGN <br />ACCESSIBLE ROUTE <br />CLEAR FLOOR SPACE <br />EV CHARGER <br />ACCESSIBLE EV STALL <br />PAINT "EV CHARGING <br />ONLY" WITH MIN. 12" <br />HIGH LETTERS W/ (2) <br />COATS OF TRAFFIC <br />WHITE <br />PAINT "NO PARKING", <br />MIN. 12" HIGH LETTERS <br />W/ (2) COATS OF <br />TRAFFIC WHITE <br />REFER TO DETAIL 11 FOR <br />ACCESS AISLE <br />REQUIREMENTS <br />AISLE BORDER LINES, <br />HATCH LINES, AND <br />LETTERS SHALL <br />CONTRAST WITH THE <br />PARKING SURFACE AND <br />THEY SHALL NOT BE <br />PAINTED THE BLUE COLOR <br />USED FOR ACCESSIBLE <br />PARKING STALLS <br />THIS STALL MAY OR <br />MAY NOT BE <br />REGULATED BY <br />SECTION 11B-812 <br />- <br />-- <br />SIDE SLOPE <br />1:10 MAX. <br />SIDE SLOPE <br />1:10 MAX. <br />RA <br />M <br />P <br /> <br />S <br />L <br />O <br />P <br />E <br />1: <br />1 <br />2 <br /> <br />M <br />A <br />X <br />. <br />CURB AS OCCURS <br />CURB RAMP AS OCCURS <br />IDENTIFICATION SIGN WITH <br />THE SYMBOL OF <br />ACCESSIBILITY MAY BE <br />REQUIRED. <br />ACCESSIBLE <br />ROUTE, TYP. <br />REFLECTORIZED SIGN PANELMIN. OF 16GA. <br />GALV. STL W/ PORCELAIN ENAMEL FINISH <br />WHITE IMAGE ON BLUE FIELD BEADED <br />REFLECTORIZED TEXTURE. COLOR #15090 <br />FED. STANDARD 595B. INTERMATIONAL <br />SYMBOL ACCESSIBILITY SIGN BOLTED TO <br />GALV. STL PIPE <br />2" DIA. GLAV. STEEL PIPE <br />PROVIDE ADD'L. <br />"VAN ACCESSIBLE" <br />TEXT AT VAN <br />ACCESSIBLE EVCS <br />STALLS <br />VAN <br />ACCESSIBLE <br />PICTOGRAM SHALL BE A <br />MINIMUM OF 6" HIGH <br />SIGN SHALL BE <br />A MINIMUM OF <br />70 SQUARE <br />INCHES <br />EVCS NOT <br />REGULATED <br />BY §11B-812 <br />SIGN NOTES (§11B-812.8) : <br /> - WHERE FOUR OR FEWER TOTAL EVCS STALLS ARE PROVIDED ON THE SITE, IDENTIFICATION SIGN IS NOT REQUIRED <br /> - WHERE FOR FIVE TO 25 TOTAL EVCS STALLS ARE PROVIDED, ONE VAN ACCESSIBLE EVCS SHALL BE IDENTIFIED. STANDARD ACCESSIBLE <br />EVCS STALLS SHALL NOT BE REQUIRED TO BE IDENTIFIED BY THIS SIGN. <br /> - WHERE FOR 26 OR MORE EVCS STALLS ARE PROVIDED, ALL REQUIRED VAN ACCESSIBLE AND ALL REQUIRED STANDARD ACCESSIBLE <br />EVCS STALLS SHALL BE IDENTIFIED BY THIS SIGN. <br /> - AMBULATORY EVCS STALLS SHALL NOT BE REQUIRED TO BE IDENTIFIED BY A SIGN. <br />NOTES: - ACCESSIBLE ELECTRICAL VEHICLE CHARGING STATIONS (EVCS) SHALL COMPLY WITH §11B-228.3 AND 11B-812 <br /> - THESE STALLS ARE NOT AND SHOULD NOT BE ACCESSIBLE PARKING STALLS PER §11B-208 & 11B-502 <br /> - THE STALL SHALL BE DESIGNED SO THAT THE ACCESSIBLE ROUTES ARE NOT OBSTRUCTED BY CABLES OR OTHER ELEMENTS <br />(§11B-812.5.5) <br /> - THE STALL AND ACCESS AISLE SHALL HAVE A MAXIMUM SLOPE OF 2% IN ANY DIRECTION (§11B-812.3) <br /> - THE ACCESS AISLE SHALL ADJOIN AN ACCESSIBLE ROUTE. TWO VEHICLES MAY SHARE A COMMON AISLE (§11B-812.7) <br /> - THE STALL ACCESS AISLE MAY BE ON EITHER SIDE OF THE STALL EXCEPT FOR VAN STALLS WHICH SHALL BE LOCATED ON THE <br />PASSENGER SIDE OF THE STALL (§11B-812.7.1) <br /> - THE OPERABLE PARTS OF THE CHARGER SHALL COMPLY WITH (§11B-309) <br />9'-0"5'-0"PER SITE PLAN <br />18 <br />' <br />- <br />0 <br />" <br /> <br />M <br />I <br />N <br />. <br />EQ.EQ. <br />PER SITE PLAN 12'-0"5'-0" <br />18 <br />' <br />- <br />0 <br />" <br />10'-0" <br />18 <br />' <br />- <br />0 <br />" <br />9'-0"5'-0" <br />20 <br />' <br />- <br />0 <br />" <br />80 <br />" <br /> <br />M <br />I <br />N <br />. <br /> <br />T <br />O <br /> <br />U <br />N <br />D <br />E <br />R <br />S <br />I <br />D <br />E <br />OF <br /> <br />S <br />I <br />G <br />N <br /> <br />( <br />P <br />O <br />S <br />T <br /> <br />M <br />O <br />U <br />N <br />T <br />E <br />D <br />) <br />60 <br />" <br /> <br />M <br />I <br />N <br />. <br /> <br />F <br />O <br />R <br /> <br />A <br /> <br />W <br />A <br />L <br />L <br />MO <br />U <br />N <br />T <br />E <br />D <br /> <br />S <br />I <br />G <br />N <br />ST <br />E <br />E <br />L <br /> <br />P <br />I <br />P <br />E <br /> <br />A <br />N <br />D <br /> <br />F <br />O <br />O <br />T <br />I <br />N <br />G <br />DO <br />E <br />S <br /> <br />N <br />O <br />T <br />OC <br />C <br />U <br />R <br /> <br />W <br />H <br />E <br />N <br /> <br />S <br />I <br />G <br />N <br /> <br />I <br />S <br />WA <br />L <br />L <br /> <br />M <br />O <br />U <br />N <br />T <br />E <br />D <br />10 <br />" <br />7" <br />6" <br />10 <br />" <br />7" <br />NO <br />PARKING <br />EV CHARGING <br />ONLY <br />NO <br />PARKING <br />EV CHARGING <br />ONLY <br />EV CHARGING <br />ONLY <br />EV CHARGING <br />ONLY <br />NO <br />PARKING <br />SINGLE ACCESS. PARKING STALL ACCESS. EVCS PARKING STALL <br />DETECTABLE WARNING <br />NOTES: <br />TRAFFIC WHITE <br />ACCESSIBLE PATH AND AISLEACCESS. PATH DIRECTIONAL SIGNACCESSIBLE PARKING SIGNSSITE ACCESSIBLE ADDITIONAL SIGN <br />ACC. DROP-OFF & LOADING ZONES <br />WALL MOUNTED DEVICES <br />5" DIA. <br />NOTE: - PARKING STALLS MARKING SHALL COMPLY WITH CBC §11B-502.6.4.1 <br /> - PAINT SYMBOL AND PERIMETER STRIPE WITH (2) COATS OF TRAFFIC WHITE <br /> - PAINT SYMBOL BACKGROUND WITH (2) COATS OF TRAFFIC BLUE (COLOR #15090 IN FED. STD. 595B) <br />11/2" <br />R 10 <br />"41/2" <br />45/8" <br />30 <br />" <br />5" <br />11/2" <br />3" <br />31/2" <br />5" <br />93.00° <br />3'-0" MIN. <br />3' <br />- <br />0 <br />" <br /> <br />M <br />I <br />N <br />. <br />3" <br />3" <br />68.00° <br />3" <br />3"3" <br />3" <br />ACCESS. PARKING SYMBOL ACCESS. OBSTRUCTIONS <br />NO <br />PARKING NO PARKING <br />PROVIDE STOP AS NEEDED <br />28 <br />A.6.2 <br />28 <br />NOT USED <br />2. REACH REQUIREMENTS SHALL COMPLY WITH CBC §11B-308 <br />SEE NOTE 1 BELOW <br />AND SHALL EXTEND THE SAME DEPTH AS THE SALES OR SERVICE COUNTER TOP. CBC 11B-904.4.1 <br />CL <br />SHEET NUMBER: <br />REVISIONS <br />DETAILS <br />PREPARED BY: <br />OWNER: <br />PROJECT: <br />STAMP:JOB NUMBER: <br />XXXXX <br />DATE: <br />00.00.00 <br />SHEET NAME: <br />CONSULTANT: <br />DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN <br />CONSTITUTE ORIGINAL AND UNPUBLISHED WORK OF PD&C, INC. <br />dba RAND KRUSE AND MAY NO BE DUPLICATED, USED OR <br />DISCLOSED WITHOUT WRITTNE CONSENT OF PD&C, INC. dba <br />RAND KRUSE. <br />A FOR PERMIT <br />SANTA ANA VENTURES, INC. <br />121 E. NEWPORT CIRCLE <br />SANTA ANA, CA 9205 <br />A6.1 <br />D <br />3419 Via Lido, Ste. 225 <br />Newport Beach, CA 92663 <br />949.500.9416 www.intrepid-group.net <br />N E W F L O W E R <br />R O O M <br />1 2 1 N E W P O R T C I R C L E <br />S A N T A A N A , C A 9 2 0 5 <br />1821 E Newport Cir <br />12/23/2024