SHEET NUMBER:
<br />REVISIONS
<br />NOTES
<br />A
<br />SHEET NAME:
<br />PREPARED BY:
<br />OWNER:
<br />PROJECT:
<br />STAMP:JOB NUMBER:
<br />XXXXX
<br />DATE:
<br />00.00.00
<br />CONSULTANT:
<br />DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN
<br />CONSTITUTE ORIGINAL AND UNPUBLISHED WORK OF PD&C, INC.
<br />dba RAND KRUSE AND MAY NO BE DUPLICATED, USED OR
<br />DISCLOSED WITHOUT WRITTNE CONSENT OF PD&C, INC. dba
<br />RAND KRUSE.
<br />ADDITIONAL FIRE DEPARTMENT NOTES
<br />1.EMERGENCY RESPONSE REPORTING OF EMERGENCIES, COORDINATION WITH
<br />EMERGENCY RESPONSE FORCES, EMERGENCY PLAN AND PROCEDURES FOR
<br />MANAGING OR REPOSNDING TO EMERGENCIES SHALL COMPLY WITH THE
<br />PROVISIONS OF CFC SECTION 401.
<br />2."DRY ROOMS' SHALL MEET CFC CHAPTER 9.
<br />3.NO SMOKING IS ALLOWED IN THIS FACILITY, CFC SECTION 310.
<br />4.HANGING PLASTIC FILMS SHALL NOT BE USED TO CREATE WALLS, CEILINGS, OR
<br />ROOMS. WHERE PLASTIC FILMS ARE APPLIED TO THE WALLS OR CEILINGS AS AN
<br />INTERIOR FINISH, MATERIAL INSTALLATION SHALL COMPLY WITH THE CBC CHAPTER
<br />8 INTERIOR FINISHES. PLASTIC FILM, FOAM PLASTIC INSULATION AND THE PAPER
<br />FACING ON FIBERGLASS INSULATION MUST BE RATED AND COVERED WITH AN
<br />APPROVED THERMAL BARRIER.
<br />5.ALL INTERIOR WALL AND CEILING FINISH MATERIALS SHALL BE LISTED AS CLASS A,
<br />CLASS B OR C.ASS C IN ACCORDANCE WITH ASTM E84 OR UL723, INCLUDING FLAME
<br />SPREAD AND SMOKE-DEVELOPED INDEXES, AND EXCLUDING MATERIALS </= 0.036"
<br />THICK APPLIED DIRECTLY TO THE SURFACE OF WALLS AND CEILINGS, CBC SECTIONS
<br />803.1.1 AND 803.2
<br />6.THE MEANS OF EGRESS, INCLUDING THE EXIT DISCHARGE, SHALL BE ILLUMINATED AT
<br />ALL TIMES THE BUILDING SPACE IS OCCUPIED IN ACCORDANCE WITH THE CBC
<br />SECTION 1008. AN 8 1
<br />2" X 11" MAP DISPLAYING THE GENERAL FLOOR PLAN OF THE
<br />FACILITY SHALL BE POSTED NEAR THE MAIN ENTRANCE IN A CLEAR PROTECTIVE
<br />COVER.
<br />7.STORAGE OF COMBUSTIBLE MATERIALS IN BUILDING SHALL BE ORDERLY AND
<br />SHAALL BE SEPARATED FROM HEATERS OR HEATING DEVICES BY DISTANCE OR
<br />SHIELDING SO THAT IGNITION CANNOT OCCUR PER CFC SECTION 315.3.
<br />8.ANY SECURITY DEVICE OR SYSTEM THAT EMITS ANY MEDIUM THAT COULD OBSCURE
<br />A MEANS OF EGRESS IN ANY BUILDING, STRUCTURE OR PREMISE SHALL BE
<br />PROHIBITED PER CFC SECTION 316.5.
<br />9.THE PROVISIONS OF THE CFC SECTIONS 407.2 THROUGH 407.7 SHALL BE
<br />APPLICABLE WHERE HAZARDOUS MATERIALS ARE SUBJECT TO PERMITS UNDER CFC
<br />SECTIONS 105.6 AND 105.7 AND ARE LOCATED ON THE PREMISES OR WHERE
<br />REQUIRED BY THE FIRE CODE OFFICIAL.
<br />10.ELECTRONIC ACCESS CONTROL SYSTEMS ON EGRESS DOORS SHALL COMPLY WITH
<br />CBC SECTION 1010.1.9.
<br />11.SMOKE AND HEAT VENTS SHALL BE INSTALLED PER CFC SECTION 910.2 IN THE ROOFS
<br />OF ONE-STORY BUILDINGS OR PORTIONS THEREOF OCCUPIED IN GROUP F-1 HAVING
<br />MORE THATN 50,000 SF OF UNDIVIDED AREA.
<br />12.SAFETY DATA SHEETS (SDS) FOR ALL CHEMICALS/HAZARDOUS MATERIALS MUST BE
<br />KEPT AT THE FACILITY.
<br />13.THE STORAGE USE AND HANDLING OF ALL HAZARDOUS MATERIALS SHALL BE IN
<br />ACCORDANCE WITH CFC CHAPTER 50. THE MAXIMUM ALLOWABLE QUANTITY OF
<br />HAZARDOUS MATERIALS PER CONTROL AREA WILL BE ESTABLISHED USING CFC
<br />SECTION 5003.1.A. THE MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA
<br />SHALL BE AS SPECIFIED IN CFC TABLES 5003.1.1 (1) THROUGH 5003.1.1 (4).
<br />14.THE INSTALLATION OF SECURITY GATES ACROSS A FIRE APPARATUS ACCESS ROAD
<br />SHALL BE APPROVED BY THE FIRE CHIEF. WHERE SECURITY GATES ARE INSTALLED,
<br />THEY SHALL HAVE AN APPROVED MEANS OF EMERGENCY OPERATION. THE SECURITY
<br />GATES AND THE EMERGENCY OPERATION SHALL BE MAINTAINED OPERATIONAL AT
<br />ALL TIMES. ELECTRIC GATE OPERATORS, WHERE PROVIDED, SHALL BE LISTED IN
<br />ACCORDANCE WITH UL 325. GATES INTENDED FOR AUTOMATIC OPERATION SHALL BE
<br />DESIGNED , CONSTRUCTED AND INSTALLED TO COMPLY WITH THE REQUIREMENTS OF
<br />ASTM F2200 (2016 CFC 503.6 SECURITY GATES).
<br />15.ANY GATE SECURING ANY DRIVEWAY SHALL COMPLY WITH THE FOLLOWING
<br />CRITERIA:
<br />15.1.A KNOX BOX WITH A KNOX MASTER KEY SHALL BE ON OR NEXT TO THE GATE.
<br />15.2.GATE WIDTH SHALL NOT BE LESS THAN 20 FT.
<br />15.3.GATES SHALL NOT BE OF THE SWINGING OR SLIDING TYPE.
<br />15.4.CONSTRUCTION OF THE GATE SHALL BE OF MATERIALS THAT ALLOW MANUAL
<br />OPERATION BY ONE PERSON.
<br />15.5.GATE COMPONENTS SHALL BE MAINTAINED IN A OPERATIVE CONDITION AT
<br />ALL TIMES AND REPLACED OR REPAIRED WHEN DEFECTIVE.
<br />15.6.ELECTRIC GATES SHALL BE EQUIPPED WITH A MEANS OF OPENING THE GATE
<br />BY FIRE DEPARTMENT PERSONNEL FOR EMERGENCY ACCESS. EMERGENCY
<br />OPENING DEVICES SHALL BE APPROVED BY THE FIRE CODE OFFICIAL.
<br />15.7.METHOD OF LOCKING SHALL BE SUBMITTED FOR APPROVAL BY THE FIRE
<br />CODE OFFICIAL.
<br />15.8.METHOD OF LOCKING SHALL BE SUBMITTED FOR APPROVAL BY THE FIRE
<br />CODE OFFICIAL. ELECTRIC GATE OPERATORS, WHERE PROVIDED, SHALL BE
<br />LISTED IN ACCORDANCE WITH UL 325.
<br />15.9.GATES INTENDED FOR AUTOMATIC OPERATION SHALL BE DESIGNED ,
<br />CONSTRUCTED AND INSTALLED TO COMPLY WITH THE REQUIREMENTS OF
<br />ASTM F2200.
<br />16.FIRE APPARATUS ACCESS ROAD SHALL BE MARKED WITH PERMANENT "NO PARKING
<br />-- FIRE LANE" SIGNS COMPLYING WITH CFC FIGURE D103.6.
<br />17.PROVIDE A 20 -LB, CLASS 4-A:80-B:C UL RATED PORTABLE FIRE EXTINGUISHER
<br />WITHIN 10 FEET OF EACH EXTERIOR EXIT; IN GROWING ROOMS, EXTRACTION LAB,
<br />DRYING ROOM, PROCESSING ROOM, AND PACKAGING ROOM WITHIN 10 FEET FROM
<br />THE EXIT ACCESS DOORS; AND ELSEWHERE SUCH THAT THE DISTANCE FROM ANY
<br />POINT IN THE BUILDING TO A FIRE EXTINGUISHER WILL NO EXCEED 50 FEET. CLASS A
<br />FRO TRASH, WOO AND PAPER; CLASS B FOR FLAMMABLE LIQUIDS AND GASES; CLASS
<br />C FOR ELECTRICAL FIRE. THE FIRE EXTINGUISHERS SHAALL BE LOCATED SUCH THAT
<br />THEY ARE VISIBLE AND READILY AVAILABLE CFC SECTION 906.3.
<br />18.PROVIDE A MANUAL FIRE ALARM BOX NOT MORE THAN 5 FEET FROM EACH
<br />ENTRANCE ON THE FIREST FLOOR, AND NOT MORE THAN 5 FEET FROM EACH
<br />STAIRWAY LANDING ON THE SECOND FLOOR (CBC 907.4.2). DENOTE THE HEIGHT OF
<br />THE FIRE ALARM BOX SHALL BE BETWEEN 42" AND 48" AFF, SHALL BE RED IN
<br />COLOR, AND INSTALL A PERMANENT SIGN ADJACENT TO EACH MANUAL FIRE ALARM
<br />BOX THAT READS: WHEN ALARM SOUNDS CALL FIRE DEPARTMENT (907.4.2.2)
<br />DENOTE EACH FIRE ALARM BOX SHALL BE TRANSPARENT OR RED IN COLOR WITH A
<br />TRANSPARENT FACE TO PERMIT VISIBILITY OF THE MANUAL FIRE ALARM BOX
<br />(907.4.2.5).
<br />19.PROVIDE A 20-LB MULTIPURPOSE 4-A:80-B:C PORTABLE FIRE EXTINGUISHER NEAR
<br />EACH FIRE ALARM. FIRE EXTINGUISHERS SHALL BE LOCATED SUCH THAT THEY ARE
<br />VISIBLE AND READILY AVAILABLE. CFC SECTION 906.3.
<br />20.WET LOCATIONS: GROW ROOMS WILL BE CONSIDERED DAMP/WET LOCATIONS AS
<br />THEY ARE SUBJECT TO WASH DOWN AND SUBJECTED TO HIGH HUMIDITY. INDOOR
<br />WET LOCATION WIRING METHODS SHALL MEET THE REQUIREMENTS OF THE CEC
<br />ARTICLE 300.3 (D) WHEN HUMIDITY IS LEFT UNCONTROLLED >50%.
<br />21.2.CIRCUIT INTERRUPTERS: GROUND FAULT INTERRUPTERS ARE REQUIRED FOR
<br />PERSONNEL PROTECTION IN THE WET LOCATIONS.
<br />CO2 GAS DETECTION SYSTEM NOTES
<br />1.CO2 GAS DETECTION SYSTEM PLANS AND SPECIFICATIONS SHALL BE DEVELOPED AND
<br />SUBMITTED TO THE APPROPRIATE JURISDICTIONS UNDER SEPARATE APPLICATION
<br />AND PERMIT.
<br />2.PRESSURE RELIEF, VENT PIPING, FILL INDICATORS, FILL CONNECTIONS, VENT
<br />TERMINATIONS, PIPING SYSTEM AS WELL AS THE STORAGE, USE AND HANDLING OF
<br />THE CARBON DIOXIDE SHALL BE IN ACCORDANCE WITH CHAPTER 53 OF THE
<br />CALIFORNIA FIRE CODE AND NFPA 55.
<br />3.A CONTINUOUS GAS DETECTION SYSTEM SHALL BE PROVIDED IN THE ROOM OR
<br />INDOOR AREA IN WHICH THE CARBON DIOXIDE ENRICHMENT PROCESS IS LOCATED.
<br />IN THE ROOM OR INDOOR AREA IN WHICH THE CONTAINER SYSTEMS ARE LOCATED
<br />AND IN OTHER AREAS WHERE CARBON DIOXIDE IS EXPECTED TO ACCUMULATE,
<br />INCLUDING ROOMS OR AREAS DIRECTLY ADJACENT TO THE ENRICHMENT AREA
<br />CONNECTED BY DOORS OR OTHER MEANS OF TRAVEL. CARBON DIOXIDE SENSORS
<br />SHALL BE PROVIDED WITHIN 12 INCHES OF THE FLOOR IN THE AREA WHERE THE GAS
<br />IS EXPECTED TO ACCUMULATE OR WHERE LEAKS ARE MOST LIKELY TO OCCUR. THE
<br />SYSTEM SHALL BE DESIGNED AS FOLLOWS:
<br />3.1.ACTIVATE A LOW-LEVEL ALARM UPON DETECTION OF A CARBON DIOXIDE
<br />CONCENTRATION NOT TO EXCEED 5,000 PPM.
<br />3.2.ACTIVATE A HIGH-LEVEL ALARM UPON DETECTION OF A CARBON DIOXIDE
<br />CONCENTRATION NOT TO EXCEED 30,000 PPM.
<br />4.A GAS DETECTION SYSTEM SHALL BE PROVIDED TO MONITOR AREAS WHERE CARBON
<br />DIOXIDE CAN ACCUMULATE. THE SYSTEM SHALL BE DESIGNED TO INITIATE A LOCAL
<br />AUDIBLE AND VISUAL ALARM IN THE ROOM OR AREA IN WHICH THE SENSOR IS
<br />INSTALLED WHEN THE LEVEL OF CARBON DIOXIDE EXCEEDS 5,000 PPM.
<br />5.ACTIVATION OF THE LOW-LEVEL GAS DETECTION SYSTEM ALARM SHALL
<br />AUTOMATICALLY:
<br />5.1.STOP THE FLOW OF CARBON DIOXIDE TO THE PIPING SYSTEM.
<br />5.2.ACTIVATE THE MECHANICAL EXHAUST VENTILATION SYSTEM.
<br />5.3.ACTIVATE AN AUDIBLE AND VISIBLE SUPERVISORY ALARM SIGNAL AT AN
<br />APPROVED LOCATION WITH THE BUILDING.
<br />6.ACTIVATION OF TGHE LOW-LEVEL GAS DETECTION SYSTEM ALARM SHALL
<br />AUTOMATICALLY:
<br />6.1.STOP THE FLOW OF CARBON DIOXIDE TO THE PIPING SYSTEM.
<br />6.2.ACTIVATE THE MECHANICAL EXHAUST VENTILATION SYSTEM.
<br />6.3.ACTIVATE AN AUDIBLE AND VISIBLE EVACUATION ALARM, BOTH INSIDE AND
<br />OUTSIDE OF THE CARBON DIOXIDE ENRICHMENT AREA AND THE AREA IN
<br />WHICH THE CARBON DIOXIDE CONTAINERS ARE LOCATED.
<br />7.GAS DETECTION SYSTEM FAILURE: FAILURE OF THE CARBON DIOXIDE GAS DETECTION
<br />SYSTEM SHALL RESULT IN IMMEDIATE ACTIVATION OF THE VENTILATION SYSTEM
<br />AND THE SHUTDOWN OF THE CARBON DIOXIDE ENRICHMENT SYSTEM.
<br />8.PRESSURIZATION AND VENTILATION IN ROOMS OR INDOOR AREAS IN WHICH
<br />CARBON DIOXIDE ENRICHMENT IS PROVIDED SHALL MAINTAIN AT A NEGATIVE
<br />PRESSURE IN RELATION TO THE SURROUNDING AREAS OF THE BUILDING. SEE
<br />SEQUENCE OF OPERATION. A MECHANICAL VENTILATION SYSTEM SHALL BE PROVIDED
<br />IN ACCORDANCE WITH THE MECHANICAL CODE THAT COMPLIES WITH THE
<br />FOLLOWING:
<br />8.1.MECHANICAL VENTILATION IN THE ROOM OR AREA SHALL BE AT A RATE OF
<br />NOT LESS THAN ONE CUBIC FOOT PER MINUTE PER SQUARE FOOT.
<br />8.2.WHEN ACTIVATED BY THE GAS DETECTION SYSTEM ALARM EVENT OR
<br />FAILURE, THE MECHANICAL VENTILATION SYSTEM SHALL REMAIN ON UNTIL
<br />MANUALLY RESET.
<br />8.3.THE EXHAUST SYSTEM INTAKES SHALL BE TAKEN FROM POINTS WITHIN 12
<br />INCHES OF THE FLOOR.
<br />8.4.THE VENTILATION SYSTEMS' PIPING SHALL TERMINATE OUTDOORS IN AN
<br />APPROVED LOCATION.
<br />8.5.THE PRESSURE DIFFERENTIAL SYSTEM SHALL BE INTERLOCKED TO THE
<br />CARBON DIOXIDE ENRICHMENT SYSTEM. FAILURE OF EITHER THE PRESSURE
<br />DIFFERENTIAL SYSTEM OR THE VENTILATION SYSTEM SHALL IMMEDIATELY
<br />RESULT IN THE SHUTDOWN OF THE CARBON DIOXIDE ENRICHMENT SYSTEM.
<br />9.HAZARD IDENTIFICATION SIGNS SHALL BE POSTED AT ALL ENTRANCES TO THE ROOM
<br />AND INDOOR AREAS WHERE THE CARBON DIOXIDE ENRICHMENT PROCESS IS
<br />LOCATED AND AT ALL ENTRANCES TO THE ROOMS OR INDOOR AREAS WHERE THE
<br />CARBON DIOXIDE CONTAINERS ARE LOCATED. THE SIGN SHALL BE A MINIMUM OF
<br />EIGHT INCHES WIDE AND SIX INCHES HIGH AND INDICATE:
<br />CAUTION - CARBON DIOXIDE GAS
<br />VENTILATE THE AREA BEFORE ENTERING
<br />A HIGH CARBON DIOXIDE (CO2) GAS CONCENTRATION
<br />IN THIS AREA CAN CAUSE ASPHYXIATION
<br />10.ALL CARBON DIOXIDE ENRICHMENT SYSTEMS SHALL BE EQUIPPED WITH AN
<br />EMERGENCY SHUT-OFF SWITCH THAT SHALL STOP THE ENRICHMENT PROCESS AND
<br />ACTIVATE THE AREA'S VENTILATION SYSTEM.
<br />ROOM DIFF. PRESS. SEQUENCE OF OP.
<br />ROOM PRESSURE CONTROL SEQUENCE OF OPERATION FOR ALL CO2 ENRICHED ROOMS
<br />NEGATIVE ROOM PRESSURE IS ACHIEVED BY REMOVING AIR FROM THE CO2 ENRICHED
<br />ROOMS USING POWERED EXHAUST FANS. THE POWER EXHAUST FANS SHALL MODULATE
<br />BASED ON DIFFERENTIAL PRESSURE BETWEEN THE CO2 ENRICHED ROOM AND THE
<br />SURROUNDING AREA. THE AIR BALANCE CONTRACTOR WILL ATTAIN THE FAN SPEED FOR THE
<br />GIVEN OPERATING MODES.
<br />1.DIFFERENTIAL PRESSURE IS MONITORED AND CONTROLLED USING A DWYER DHII
<br />DIFFERENTIAL PRESSURE (DP) CONTROLLER, AND POWER EXHAUST FAN WITH A
<br />VARIABLE SPEED DRIVE (VFD).
<br />2.A NEGATIVE ROOM DP SETPOINT IS TO BE MAINTAINED AT ALL TIMES WHILE THE CO2
<br />ENRICHMENT SYSTEM IS ACTIVATED.
<br />3.THE DIFFERENTIAL PRESSURE CONTROLLER (SYSTEM) SHALL BE INTERLOCKED TO
<br />THE CO2 ENRICHMENT SYSTEM. FAILURE OF THE SYSTEM SHALL IMMEDIATELY
<br />RESULT IN THE SHUTDOWN OF THE CO2 ENRICHMENT SYSTEM.
<br />4.THIS SYSTEM IS TO BE USED IN CONJUNCTION WITH A PROPERLY BALANCED HVAC
<br />SYSTEM.
<br />CANNABIS ODOR CONTROL NOTES
<br />1.CONTROL OF ODOR EMITTED BY THE CULTIVATION OF CANNABIS PLANTS WILL BE
<br />CONTROLLED BY OZONE GENERATORS.
<br />2.OZONE GENERATORS SHALL BE INSTALLED ON ALL EXHAUST SYSTEMS USED IN THE
<br />CULTIVATION ROOMS.
<br />3.OZONE GENERATORS ARE DESIGNATED AS EQUIPMENT NUMBER SBR-1 IN THE
<br />CONTRACT DOCUMENTS.
<br />FOR PERMIT
<br />N/A
<br />A.1.0
<br />A.1.0
<br />N/A
<br />N/A
<br />T-24 SHEETS
<br />N/A
<br />N/A
<br />N/A
<br />A.CS.1 CALGREEN NOTES #1
<br />N/A
<br />N/A
<br />N/A
<br />N/A
<br />N/A
<br />N/A
<br />N/A
<br />N/A
<br />A.1.2 CONST. WASTE NOTES
<br />N/A
<br />N/A
<br />N/A
<br />N/A
<br />N/A
<br />N/A
<br />N/A
<br />N/A
<br />N/A
<br />N/A
<br />N/A
<br />N/A
<br />N/A
<br />N/A
<br />N/A
<br />N/A
<br />N/A
<br />N/A
<br />A.CS.1
<br />1821 E. NEWPORT CIRCLE, SANTA ANA, CA
<br />TENANT IMPROVEMENT
<br />SANTA ANA VENTURES, INC.
<br />1821 E. NEWPORT CIRCLE
<br />SANTA ANA, CA 92705
<br />KEYNOTE 'E'
<br />OCFA NOTES
<br />CalGreen Notes. #2
<br />A.CS.1
<br />A.CS.1
<br />A.CS.1
<br />A.CS.1
<br />A.CS.1
<br />A.CS.1
<br />A.CS.1
<br />A.CS.1
<br />A.CS.1
<br />A.CS.1
<br />A.CS.1
<br />A.CS.1
<br />A.CS.1
<br />A.CS.1
<br />A.CS.1
<br />A.CS.1
<br />A.CS.1
<br />A.CS.1
<br />CalGreen Notes. #4
<br />CalGreen Notes. #8
<br />CalGreen Notes. #9
<br />CalGreen Notes. #9.1
<br />CalGreen Notes. #10
<br />CalGreen Notes. #12
<br />CalGreen Notes. #14
<br />CalGreen Notes. #15
<br />CalGreen Notes. #16
<br />CalGreen Notes. #17
<br />CalGreen Notes. #18
<br />CalGreen Notes. #19
<br />CalGreen Notes. #20
<br />CalGreen Notes. #20
<br />CalGreen Notes. #20
<br />CalGreen Notes. #22
<br />CalGreen Notes. #23
<br />CalGreen Notes. #24
<br />KEYNOTE 'D'
<br />1.WATER CONSERVING PLUMBING FIXTURES AND FITTINGS. PLUMBING FIXTURES (WATER
<br />CLOSETS AND URINALS) AND FITTINGS (FAUCETS AND SHOWERHEADS) SHALL COMPLY
<br />WITH THE FOLLOWING:
<br />1.1.WATER CLOSETS. THE EFFECTIVE FLUSH VOLUME OF ALL WATER CLOSETS SHALL
<br />NOT EXCEED 1.28 GALLONS PER FLUSH. TANK-TYPE WATER CLOSETS SHALL BE
<br />CERTIFIED TO THE PERFORMANCE CRITERIA OF THE U.S. EPA WATERSENSE
<br />SPECIFICATION FOR TANK-TYPE TOILETS. NOTE: THE EFFECTIVE FLUSH VOLUME
<br />OF DUAL FLUSH TOILETS IS DEFINED AS THE COMPOSITE, AVERAGE FLUSH
<br />VOLUME OF TWO REDUCED FLUSHES AND ONE FULL FLUSH.
<br />1.2.URINALS.
<br />1.2.1.WALL-MOUNTED URINALS. THE EFFECTIVE FLUSH VOLUME OF
<br />WALL-MOUNTED URINALS SHALL NOT EXCEED 0.125 GALLONS PER
<br />FLUSH.
<br />1.2.2.FLOOR-MOUNTED URINALS. THE EFFECTIVE FLUSH VOLUME OF
<br />FLOOR-MOUNTED OR OTHER URINALS SHALL NOT EXCEED 0.5 GALLONS
<br />PER FLUSH.
<br />1.3.FAUCETS AND FOUNTAINS.
<br />1.3.1.LAVATORY FAUCETS SHALL HAVE A MAXIMUM FLOW RATE OF NOT MORE
<br />THAN 0.5 GALLONS PER MINUTE AT 60 PSI.
<br />1.3.2.KITCHEN FAUCETS SHALL HAVE A MAXIMUM FLOW RATE OF NOT MORE
<br />THAN 1.8 GALLONS PER MINUTE AT 60 PSI. KITCHEN FAUCETS MAY
<br />TEMPORARILY INCREASE THE FLOW ABOVE THE MAXIMUM RATE, BUT
<br />NOT TO EXCEED 2.2 GALLONS PER MINUTE AT 60 PSI, AND MUST
<br />DEFAULT TO A MAXIMUM FLOW RATE OF 1.8 GALLONS PER MINUTE AT
<br />60 PSI.
<br />1.3.3.WASH FOUNTAINS SHALL HAVE A MAXIMUM FLOW RATE OF NOT MORE
<br />THAN1.8 GALLONS PER MINUTE/20 [RIM SPACE (INCHES) AT 60 PSI].
<br />1.3.4.METERING FAUCETS SHALL NOT DELIVER MORE THAN 0.20 GALLONS PER
<br />CYCLE.
<br />1.3.5.METERING FAUCETS FOR WASH FOUNTAINS SHALL HAVE A MAXIMUM
<br />FLOW RATE OF NOT MORE THAN 0.20 GALLONS PER MINUTE/20 [RIM
<br />SPACE (INCHES) AT 60 PSI]. NOTE: WHERE COMPLYING FAUCETS ARE
<br />UNAVAILABLE, AERATORS OR OTHER MEANS MAY BE USED TO ACHIEVE
<br />REDUCTION.
<br />2.COVERING OF DUCT OPENINGS AND PROTECTION OF MECHANICAL EQUIPMENT DURING
<br />CONSTRUCTION. AT THE TIME OF ROUGH INSTALLATION, OR DURING STORAGE ON THE
<br />CONSTRUCTION SITE AND UNTIL FINAL STARTUP OF THE HEATING, COOLING AND
<br />VENTILATING EQUIPMENT, ALL DUCT AND OTHER RELATED AIR DISTRIBUTION
<br />COMPONENT OPENINGS SHALL BE COVERED WITH TAPE, PLASTIC, SHEET METAL OR
<br />OTHER METHODS ACCEPTABLE TO THE ENFORCING AGENCY TO REDUCE THE AMOUNT OF
<br />DUST, WATER AND DEBRIS WHICH MAY COLLECT IN THE SYSTEM.
<br />3.POLLUTANT CONTROL
<br />3.1.TEMPORARY VENTILATION. THE PERMANENT HVAC SYSTEM SHALL ONLY BE
<br />USED DURING CONSTRUCTION IF NECESSARY TO CONDITION THE BUILDING OR
<br />AREAS OF ADDITION OR ALTERATION WITHIN THE REQUIRED TEMPERATURE
<br />RANGE FOR MATERIAL AND EQUIPMENT INSTALLATION. IF THE HVAC SYSTEM IS
<br />USED DURING CONSTRUCTION, USE RETURN AIR FILTERS WITH A MINIMUM
<br />EFFICIENCY REPORTING VALUE (MERV) OF 8, BASED ON ASHRAE 52.2-1999, OR
<br />AN AVERAGE EFFICIENCY OF 30% BASED ON ASHRAE 52.1-1992 REPLACE ALL
<br />FILTERS IMMEDIATELY PRIOR TO OCCUPANCY, OR, IF THE BUILDING IS
<br />OCCUPIED DURING ALTERATION, AT THE CONCLUSION OF CONSTRUCTION.
<br />4.FINISH MATERIAL POLLUTANT CONTROL. FINISH MATERIALS SHALL COMPLY WITH THE
<br />FOLLOWING:
<br />4.1.ADHESIVES, SEALANTS AND CAULKS. ADHESIVES, SEALANTS, AND CAULKS USED
<br />ON THE PROJECT SHALL MEET THE REQUIREMENTS OF THE FOLLOWING
<br />STANDARDS:
<br />4.2.ADHESIVES, ADHESIVE BONDING PRIMERS ADHESIVE PRIMERS, SEALANTS,
<br />SEALANT PRIMERS AND CAULKS SHALL COMPLY WITH LOCAL OR REGIONAL AIR
<br />POLLUTION CONTROL OR AIR QUALITY MANAGEMENT DISTRICT RULES WHERE
<br />APPLICABLE, OR SCAQMD RULE 1168 VOC LIMITS. SUCH PRODUCTS ALSO SHALL
<br />COMPLY WITH THE RULE 1168 PROHIBITION ON THE USE OF CERTAIN TOXIC
<br />COMPOUNDS (CHLOROFORM, ETHYLENE DICHLORIDE, METHYLENE CHLORIDE,
<br />PERCHLOROETHYLENE AND TRICHLOROETHYLENE), EXCEPT FOR AEROSOL
<br />PRODUCTS AS SPECIFIED IN SUBSECTION 2, BELOW.
<br />4.3.AEROSOL ADHESIVES, AND SMALLER UNIT SIZES OF ADHESIVES, AND SEALANT
<br />OR CAULKING COMPOUNDS (IN UNITS OF PRODUCT, LESS PACKAGING, WHICH
<br />DO NOT WEIGH MORE THAN ONE POUND AND DO NOT CONSIST OF MORE
<br />THAN 16 FLUID OUNCES) SHALL COMPLY WITH STATEWIDE VOC STANDARDS
<br />AND OTHER REQUIREMENTS, INCLUDING PROHIBITIONS ON USE OF CERTAIN
<br />TOXIC COMPOUNDS, OF CALIFORNIA CODE OF REGULATIONS, TITLE 17,
<br />COMMENCING WITH SECTION 94507.
<br />5.PAINTS AND COATINGS. ARCHITECTURAL PAINTS AND COATINGS SHALL COMPLY WITH
<br />VOC LIMITS IN TABLE 1 OF THE ARB ARCHITECTURAL COATINGS SUGGESTED CONTROL
<br />MEASURE, AS SHOWN IN CALGREEN TABLE 5.504.4.3, UNLESS MORE STRINGENT LOCAL
<br />LIMITS APPLY. THE VOC CONTENT LIMIT FOR COATINGS THAT DO NOT MEET THE
<br />DEFINITIONS FOR THE SPECIALTY COATINGS CATEGORIES LISTED IN TABLE 5.504.4.3
<br />SHALL BE DETERMINED BY CLASSIFYING THE COATING AS A FLAT, NONFLAT OR
<br />NONFLAT-HIGH GLOSS COATING, BASED ON ITS GLOSS, AS DEFINED IN SUBSECTIONS
<br />4.21, 4.36 AND 4.37 OF THE 2007 CALIFORNIA AIR RESOURCES BOARD SUGGESTED
<br />CONTROL MEASURE, AND THE CORRESPONDING FLAT, NONFLAT OR NONFLAT-HIGH
<br />GLOSS VOC LIMIT IN TABLE 5.504.4.3 SHALL APPLY.
<br />6.AEROSOL PAINTS AND COATINGS. AEROSOL PAINTS AND COATINGS SHALL MEET THE
<br />PWMIR LIMITS FOR ROC IN SECTION 94522(A)(3) AND OTHER REQUIREMENTS,
<br />INCLUDING PROHIBITIONS ON USE OF CERTAIN TOXIC COMPOUNDS AND OZONE
<br />DEPLETING SUBSTANCES, IN SECTIONS 94522(C)(2) AND (D)(2) OF CALIFORNIA CODE
<br />OF REGULATIONS, TITLE 17, COMMENCING WITH SECTION 94520; AND IN AREAS UNDER
<br />THE JURISDICTION OF THE BAY AREA AIR QUALITY MANAGEMENT DISTRICT
<br />ADDITIONALLY COMPLY WITH THE PERCENT VOC BY WEIGHT OF PRODUCT
<br />LIMITS OF REGULATION 8 RULE 49.
<br />7.VERIFICATION. VERIFICATION OF COMPLIANCE WITH THIS SECTION SHALL BE PROVIDED
<br />AT THE REQUEST OF THE ENFORCING AGENCY. DOCUMENTATION MAY INCLUDE, BUT IS
<br />NOT LIMITED TO, THE FOLLOWING:
<br />7.1.MANUFACTURER'S PRODUCT SPECIFICATION
<br />7.2.FIELD VERIFICATION OF ON-SITE PRODUCT CONTAINERS
<br />8.CARPET SYSTEMS. ALL CARPET INSTALLED IN THE BUILDING INTERIOR SHALL MEET AT
<br />LEAST ONE OF THE TESTING AND PRODUCT REQUIREMENTS:
<br />8.1.CARPET AND RUG INSTITUTE'S GREEN LABEL PLUS PROGRAM.
<br />8.2.COMPLIANT WITH THE VOC-EMISSION LIMITS AND TESTING REQUIREMENTS
<br />SPECIFIED IN THE CALIFORNIA DEPARTMENT OF PUBLIC HEALTH STANDARD
<br />METHOD FOR THE TESTING AND EVALUATION OF VOLATILE ORGANIC
<br />CHEMICAL EMISSIONS FROM INDOOR SOURCES USING ENVIRONMENTAL
<br />CHAMBERS, VERSION 1.1, FEBRUARY 2010 (ALSO KNOWN AS CDPH STANDARD
<br />METHOD V1.1 OR SPECIFICATION 01350).
<br />8.3.NSF/ANSI 140 AT THE GOLD LEVEL OR HIGHER;
<br />8.4.SCIENTIFIC CERTIFICATIONS SYSTEMS SUSTAINABLE CHOICE; OR
<br />8.5.COMPLIANT WITH THE COLLABORATIVE FOR HIGH PERFORMANCE SCHOOLS
<br />CALIFORNIA (CA-CHPS) CRITERIA INTERPRETATION FOR EQ 7.0 AND EQ 7.1
<br />(FORMERLY EQ 2.2) DATED JULY 2012 AND LISTED IN THE CHPS HIGH
<br />PERFORMANCE PRODUCT DATABASE.
<br />CALGREEN NOTES
<br />9.CARPET CUSHION. ALL CARPET CUSHION INSTALLED IN THE BUILDING INTERIOR SHALL
<br />MEET THE REQUIREMENTS OF THE CARPET AND RUG INSTITUTE GREEN LABEL PROGRAM.
<br />9.1.CARPET ADHESIVE. ALL CARPET ADHESIVE SHALL MEET THE REQUIREMENTS
<br />CALGREEN TABLE 5.504.4.1.
<br />10.COMPOSITE WOOD PRODUCTS. HARDWOOD PLYWOOD, PARTICLEBOARD AND MEDIUM
<br />DENSITY FIBERBOARD COMPOSITE WOOD PRODUCTS USED ON THE INTERIOR OR
<br />EXTERIOR OF THE BUILDINGS SHALL MEET THE REQUIREMENTS FOR
<br />FORMALDEHYDE AS SPECIFIED IN ARB'S AIR TOXICS CONTROL MEASURE FOR
<br />COMPOSITE WOOD (17 CCR 93120 ET SEQ.). THOSE MATERIALS NOT EXEMPTED UNDER
<br />THE ATCM MUST MEET THE SPECIFIED EMISSION LIMITS, AS SHOWN IN CALGREEN
<br />TABLE 5.504.4.5.
<br />11.DOCUMENTATION. VERIFICATION OF COMPLIANCE WITH THIS SECTION SHALL BE
<br />PROVIDED AS REQUESTED BY THE ENFORCING AGENCY. DOCUMENTATION SHALL
<br />INCLUDE AT LEAST ONE OF THE FOLLOWING:
<br />11.1.PRODUCT CERTIFICATIONS AND SPECIFICATIONS.
<br />11.2.CHAIN OF CUSTODY CERTIFICATIONS.
<br />11.3.PRODUCT LABELED AND INVOICED AS MEETING THE COMPOSITE WOOD
<br />PRODUCTS REGULATION (SEE CCR, TITLE 17, SECTION 93120, ET SEQ.).
<br />11.4.EXTERIOR GRADE PRODUCTS MARKED AS MEETING THE PS-1 OR PS-2
<br />STANDARDS OF THE ENGINEERED WOOD ASSOCIATION, THE AUSTRALIAN AS/NZS
<br />2269 OR EUROPEAN 636 3S STANDARDS.
<br />11.5.OTHER METHODS ACCEPTABLE TO THE ENFORCING AGENCY.
<br />12.RESILIENT FLOORING SYSTEMS. FOR 80 PERCENT OF FLOOR AREA RECEIVING RESILIENT
<br />FLOORING, INSTALLED RESILIENT FLOORING SHALL MEET AT LEAST ONE OF THE
<br />FOLLOWING:
<br />12.1.CERTIFIED UNDER THE RESILIENT FLOOR COVERING INSTITUTE (RFCI)
<br />FLOORSCORE PROGRAM;
<br />12.2.COMPLIANT WITH THE VOC-EMISSION LIMITS AND TESTING REQUIREMENTS
<br />SPECIFIED IN THE CALIFORNIA DEPARTMENT OF PUBLIC HEALTH'S 2010
<br />STANDARD METHOD FOR THE TESTING AND EVALUATION CHAMBERS,
<br />VERSION 1.1, FEBRUARY 2010;
<br />12.3.COMPLIANT WITH THE COLLABORATIVE FOR HIGH PERFORMANCE SCHOOLS
<br />CALIFORNIA (CA-CHPS) CRITERIA INTERPRETATION FOR EQ 7. AND EQ 7.1
<br />(FORMERLY EQ 2.2) DATED JULY 2012 AND LISTED IN THE CHPS HIGH
<br />PERFORMANCE PRODUCT DATABASE; OR
<br />12.4.PRODUCTS CERTIFIED UNDER UL GREENGUARD GOLD (FORMERLY THE
<br />GREENGUARD CHILDREN'S & SCHOOLS PROGRAM).
<br />13.VERIFICATION OF COMPLIANCE. DOCUMENTATION SHALL BE PROVIDED VERIFYING THAT
<br />RESILIENT FLOORING MATERIALS MEET THE POLLUTANT EMISSION LIMITS.
<br />14.FILTERS. IN MECHANICALLY VENTILATED BUILDINGS, PROVIDE REGULARLY OCCUPIED
<br />AREAS OF THE BUILDING WITH AIR FILTRATION MEDIA FOR OUTSIDE AND RETURN AIR
<br />THAT PROVIDES AT LEAST A MINIMUM EFFICIENCY REPORTING VALUE (MERV) OF
<br />8. MERV 8 FILTERS SHALL BE INSTALLED PRIOR TO OCCUPANCY, AND
<br />RECOMMENDATIONS FOR MAINTENANCE WITH FILTERS OF THE SAME VALUE SHALL BE
<br />INCLUDED IN THE OPERATION AND MAINTENANCE MANUAL.
<br />14.1.EXCEPTIONS:
<br />14.1.1.AN ASHRAE 10% TO 15% EFFICIENCY FILTER SHALL BE PERMITTED FOR
<br />AN HVAC UNIT MEETING THE 2013
<br />CALIFORNIA ENERGY CODE HAVING 60,000 BTU/H OR LESS CAPACITY
<br />PER FAN COIL, IF THE ENERGY USE OF THE AIR
<br />DELIVERY SYSTEM IS 0.4 W/CFM OR LESS AT DESIGN AIR FLOW.
<br />14.1.2.EXISTING MECHANICAL EQUIPMENT.
<br />14.2.LABELING. INSTALLED FILTERS SHALL BE CLEARLY LABELED BY THE
<br />MANUFACTURER INDICATING THE MERV RATING.
<br />15.ENVIRONMENTAL TOBACCO SMOKE (ETS) CONTROL. WHERE OUTDOOR AREAS ARE
<br />PROVIDED FOR SMOKING, PROHIBIT SMOKING WITHIN 25 FEET OF BUILDING ENTRIES,
<br />OUTDOOR AIR INTAKES AND OPERABLE WINDOWS AND WITHIN THE BUILDING AS
<br />ALREADY PROHIBITED BY OTHER LAWS OR REGULATIONS; OR AS ENFORCED BY
<br />ORDINANCES, REGULATIONS OR POLICIES OF ANY CITY, COUNTY, CITY AND COUNTY,
<br />CALIFORNIA COMMUNITY COLLEGE, CAMPUS OF THE CALIFORNIA STATE UNIVERSITY, OR
<br />CAMPUS OF THE UNIVERSITY OF CALIFORNIA, WHICHEVER ARE MORE STRINGENT. WHEN
<br />ORDINANCES, REGULATIONS OR POLICIES ARE NOT IN PLACE, POST SIGNAGE TO INFORM
<br />BUILDING OCCUPANTS OF THE PROHIBITIONS.
<br />16.INDOOR MOISTURE CONTROL. BUILDINGS SHALL MEET OR EXCEED THE PROVISIONS OF
<br />CALIFORNIA BUILDING CODE, CCR, TITLE 24, PART 2, SECTIONS 1203 (VENTILATION)
<br />AND CHAPTER 14 (EXTERIOR WALLS). FOR ADDITIONAL MEASURES NOT APPLICABLE TO
<br />LOW-RISE RESIDENTIAL OCCUPANCIES, SEE SECTION 5.407.2 OF THE CALGREEN CODE.
<br />17.OUTSIDE AIR DELIVERY. FOR MECHANICALLY OR NATURALLY VENTILATED SPACES IN
<br />BUILDINGS, MEET THE MINIMUM REQUIREMENTS OF SECTION 120.1 (REQUIREMENTS
<br />FOR VENTILATION) OF THE CALIFORNIA ENERGY CODE, OR THE APPLICABLE LOCAL CODE,
<br />WHICHEVER IS MORE STRINGENT, AND DIVISION 1, CHAPTER 4 OF CCR, TITLE 8.
<br />18.CARBON DIOXIDE (CO2) MONITORING. FOR BUILDINGS OR ADDITIONS EQUIPPED WITH
<br />DEMAND CONTROL VENTILATION, CO2 SENSORS AND VENTILATION CONTROLS SHALL BE
<br />SPECIFIED AND INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS OF THE
<br />CALIFORNIA ENERGY CODE, SECTION 120(C)(4).
<br />19.ACOUSTICAL CONTROL. EMPLOY BUILDING ASSEMBLIES AND COMPONENTS WITH
<br />SOUND TRANSMISSION CLASS (STC) VALUES DETERMINED IN ACCORDANCE WITH ASTM
<br />E 90 AND ASTM E 413, OR OUTDOOR-INDOOR SOUND TRANSMISSION CLASS (OITC)
<br />DETERMINED IN ACCORDANCE WITH ASTM E 1332, USING EITHER THE PRESCRIPTIVE OR
<br />PERFORMANCE METHOD IN CALGREEN SECTION 5.507.4.1 OR 5.507.4.2.
<br />19.1.EXCEPTION: BUILDINGS WITH FEW OR NO OCCUPANTS OR WHERE OCCUPANTS
<br />ARE NOT LIKELY TO BE AFFECTED BY EXTERIOR NOISE, AS DETERMINED BY THE
<br />ENFORCEMENT AUTHORITY, SUCH AS FACTORIES, STADIUMS, STORAGE,
<br />ENCLOSED PARKING STRUCTURES AND UTILITY BUILDINGS
<br />19.2.EXCEPTION: [DSA-SS] FOR PUBLIC SCHOOLS AND COMMUNITY COLLEGES, THE
<br />REQUIREMENTS OF THIS SECTION AND ALL SUBSECTIONS APPLY ONLY TO NEW
<br />CONSTRUCTION.
<br />20.EXTERIOR NOISE TRANSMISSION, PRESCRIPTIVE METHOD. WALL AND ROOF-CEILING
<br />ASSEMBLIES EXPOSED TO THE NOISE SOURCE MAKING UP THE BUILDING OR ADDITION
<br />ENVELOPE OR ALTERED ENVELOPE SHALL MEET A COMPOSITE STC RATING OF AT LEAST
<br />50 OR A COMPOSITE OITC RATING OF NO LESS THAN 40, WITH EXTERIOR WINDOWS OF
<br />A MINIMUM STC OF 40 OR OITC OF 30 IN THE FOLLOWING LOCATIONS:
<br />20.1.WITHIN THE 65 CNEL NOISE CONTOUR OF AN AIRPORT.
<br />20.1.1.EXCEPTIONS:
<br />20.1.1.1.LDN OR CNEL FOR MILITARY AIRPORTS SHALL BE DETERMINED
<br />BY THE FACILITY AIR INSTALLATION COMPATIBLE LAND USE
<br />ZONE (AICUZ) PLAN.
<br />20.1.1.2.LDN OR CNEL FOR OTHER AIRPORTS AND HELIPORTS FOR WHICH
<br />A LAND USE PLAN HAS NOT BEEN DEVELOPED SHALL BE
<br />DETERMINED BY THE LOCAL GENERAL PLAN NOISE ELEMENT.
<br />20.1.1.3.WITHIN THE 65 CNEL OR LDN NOISE CONTOUR OF A FREEWAY OR
<br />EXPRESSWAY, RAILROAD, INDUSTRIAL SOURCE OR
<br />FIXED-GUIDEWAY SOURCE AS DETERMINED BY THE NOISE
<br />ELEMENT OF THE GENERAL PLAN.
<br />20.2.NOISE EXPOSURE WHERE NOISE CONTOURS ARE NOT READILY AVAILABLE.
<br />BUILDINGS EXPOSED TO A NOISE LEVEL OF 65 DB L/EQ - 1-HR DURING
<br />ANY HOUR OF OPERATION SHALL HAVE BUILDING, ADDITION OR ALTERATION
<br />EXTERIOR WALL AND ROOF-CEILING ASSEMBLIES EXPOSED TO THE NOISE
<br />SOURCE MEETING A COMPOSITE STC RATING OF AT LEAST 45 (OR OITC 35),
<br />WITH EXTERIOR WINDOWS OF A MINIMUM STC OF 40 (OR OITC 30).
<br />21.PERFORMANCE METHOD. FOR BUILDINGS LOCATED AS DEFINED IN SECTION 5.507.4.1
<br />OR 5.507.4.1.1, WALL AND ROOF-CEILING ASSEMBLIES EXPOSED TO THE NOISE SOURCE
<br />MAKING UP THE BUILDING OR ADDITION ENVELOPE OR ALTERED ENVELOPE SHALL BE
<br />CONSTRUCTED TO PROVIDE AN INTERIOR NOISE ENVIRONMENT ATTRIBUTABLE TO
<br />EXTERIOR SOURCES THAT DOES NOT EXCEED AN HOURLY EQUIVALENT NOISE LEVEL
<br />(LEQ-1HR) OF 50 DBA IN OCCUPIED AREAS DURING ANY HOUR OF OPERATION.
<br />21.1 SITE FEATURES. EXTERIOR FEATURES SUCH AS SOUND WALLS OR EARTH
<br />BERMS MAY BE UTILIZED AS APPROPRIATE TO THE BUILDING, ADDITION OR ALTERATION
<br />PROJECT TO MITIGATE SOUND MIGRATION TO THE INTERIOR.
<br />21.2 DOCUMENTATION OF COMPLIANCE. AN ACOUSTICAL ANALYSIS
<br />DOCUMENTING COMPLYING INTERIOR SOUND LEVELS SHALL BE PREPARED BY
<br />PERSONNEL APPROVED BY THE ARCHITECT OR ENGINEER OF RECORD.
<br />22.INTERIOR SOUND TRANSMISSION. WALL AND FLOOR-CEILING ASSEMBLIES SEPARATING
<br />TENANT SPACES AND TENANT SPACES AND PUBLIC PLACES SHALL HAVE AN STC OF
<br />AT LEAST 40. NOTE: EXAMPLES OF ASSEMBLIES AND THEIR VARIOUS STC RATINGS MAY
<br />BE FOUND AT THE CALIFORNIA OFFICE OF NOISE CONTROL:
<br />WWW.TOOLBASE.ORG/PDF/CASESTUDIES/STC_ICC_RATINGS.PDF.
<br />23.OZONE DEPLETION AND GREENHOUSE GAS REDUCTIONS. INSTALLATIONS OF HVAC,
<br />REFRIGERATION AND FIRE SUPPRESSION EQUIPMENT SHALL COMPLY WITH CALGREEN
<br />SECTIONS 5.508.1.1 AND 5.508.1.2.
<br />23.1 CHLOROFLUOROCARBONS (CFCS). INSTALL HVAC, REFRIGERATION AND
<br />FIRE SUPPRESSION EQUIPMENT THAT DO NOT CONTAIN CFCS.
<br />23.2 HALONS. INSTALL HVAC, REFRIGERATION AND FIRE SUPPRESSION
<br />EQUIPMENT THAT DO NOT CONTAIN HALONS.
<br />24.SUPERMARKET REFRIGERANT LEAK REDUCTION. NEW COMMERCIAL REFRIGERATION
<br />SYSTEMS SHALL COMPLY WITH THE PROVISIONS OF THIS SECTION WHEN INSTALLED IN
<br />RETAIL FOOD STORES 8,000 SQUARE FEET OR MORE CONDITIONED AREA, AND THAT
<br />UTILIZE EITHER REFRIGERATED DISPLAY CASES, OR WALK-IN COOLERS OR FREEZERS
<br />CONNECTED TO REMOTE COMPRESSOR UNITS OR CONDENSING UNITS. THE LEAK
<br />REDUCTION MEASURES APPLY TO REFRIGERATION SYSTEMS CONTAINING
<br />HIGH-GLOBAL-WARMING POTENTIAL (HIGH-GWP) REFRIGERANTS WITH A GWP OF 150
<br />OR GREATER. NEW REFRIGERATION SYSTEMS INCLUDE BOTH NEW FACILITIES AND THE
<br />REPLACEMENT OF EXISTING REFRIGERATION SYSTEMS IN EXISTING FACILITIES.
<br />INSPECTIONS
<br />1.OCFA FINAL INSPECTION REQUIRED. PLEASE SCHEDULE ALL FIELD INSPECTIONS AT
<br />LEAST 48 HOURS IN ADVANCE. INSPECTIONS CANCELED AFTER 1 P.M. ON THE DAY
<br />BEFORE THE SCHEDULED DATE WILL BE SUBJECT TO A REINSPECTION FEE. PHASING OF
<br />INSPECTIONS MAY REQUIRE ADDITIONAL FEES, ALSO. CALL OCFA INSPECTION
<br />SCHEDULING AT 714-573-6150.
<br />2.BUILDINGS UNDER CONSTRUCTION OR DEMOLITION SHALL CONFORM TO CFC CHAPTER
<br />33. NO SMOKING OR COOKING IS ALLOWED IN STRUCTURES WHERE COMBUSTIBLE
<br />MATERIALS ARE EXPOSED OR WITHIN 25 FEET OF COMBUSTIBLE MATERIALS STORAGE
<br />AREAS. CUTTING, WELDING, OR OTHER HOT WORK SHALL BE IN CONFORMANCE WITH
<br />CFC CHAPTER 35.
<br />3.IN BUILDINGS FOUR OR MORE STORIES IN HEIGHT, STANDPIPES SHALL BE PROVIDED
<br />DURING CONSTRUCTION WHEN THE HEIGHT REACHES 40 FEET ABOVE THE LOWEST
<br />POINT OF FIRE DEPARTMENT ACCESS. A FIRE DEPARTMENT CONNECTION SHALL BE NO
<br />MORE THAN 100 FEET FROM AVAILABLE FIRE DEPARTMENT VEHICLE ACCESS ROADWAYS.
<br />A HYDRANT SHALL BE LOCATED ALONG THE ACCESS ROADWAY WITHIN 150 FEET OF THE
<br />LOCATION(S) THAT THE FDC CAN BE ACCESSED FROM. CFC 3310, 3313
<br />4.ADDRESS NUMBERS SHALL BE PROVIDED FOR ALL NEW AND EXISTING BUILDINGS, BE A
<br />MINIMUM OF 4 INCHES HIGH FOR INDIVIDUAL DWELLING UNITS AND 6 INCHES HIGH
<br />FOR ALL OTHER INSTALLATIONS AND STRUCTURES, CONTRAST WITH THEIR
<br />BACKGROUND, AND BE PLAINLY VISIBLE FROM THE ROADWAY THE BUILDING IS
<br />ADDRESSED ON. TEMPORARY ADDRESS NUMBERS SHALL BE PROVIDED ON
<br />CONSTRUCTION FENCING OR THE BUILDING UNTIL PERMANENT NUMBERS CAN BE
<br />PROVIDED. CBC 501.2, CFC 505.1
<br />5.LOCATIONS AND CLASSIFICATIONS OF EXTINGUISHERS SHALL BE IN ACCORDANCE WITH
<br />CFC 906 AND CCR TITLE 19. AT LEAST ONE EXTINGUISHER SHALL BE PROVIDED DURING
<br />CONSTRUCTION ON EACH FLOOR AT EACH STAIRWAY, IN EACH STORAGE AND
<br />CONSTRUCTION SHED, IN LOCATIONS WHERE FLAMMABLE OR COMBUSTIBLE LIQUIDS
<br />ARE STORED OR USED, OR WHERE SIMILAR HAZARDS ARE PRESENT PER CFC 3315.1.
<br />BEFORE FINAL OCCUPANCY, AT LEAST ONE 2A:10B:C EXTINGUISHER SHALL BE PROVIDED
<br />SO THAT NO POINT IS MORE THAN 75 FEET TRAVEL DISTANCE FROM THE EXTINGUISHER.
<br />EXTINGUISHERS SHALL BE LOCATED ALONG THE PATH OF EGRESS TRAVEL AND IN A
<br />READILY VISIBLE AND ACCESSIBLE LOCATION, WITH THE BOTTOM OF THE EXTINGUISHER
<br />AT LEAST 4 INCHES ABOVE THE FLOOR. ADDITIONAL EXTINGUISHERS MAY BE REQUIRED
<br />BY OCFA INSPECTORS DEPENDING ON PROJECT OR SITE CONDITIONS AND FINAL
<br />PLACEMENT IS SUBJECT TO THEIR APPROVAL.
<br />6.WALL, FLOOR AND CEILING FINISHES AND MATERIALS SHALL NOT EXCEED THE FLAME
<br />SPREAD CLASSIFICATIONS IN CBC TABLE 803.11. DECORATIVE MATERIALS SHALL BE
<br />PROPERLY TREATED BY A PRODUCT OR PROCESS APPROVED BY THE STATE FIRE
<br />MARSHAL WITH APPROPRIATE DOCUMENTATION PROVIDED TO THE OCFA. SUCH ITEMS
<br />SHALL BE APPROVED AND INSPECTED BY THE OCFA PRIOR TO INSTALLATION.
<br />7.KNOX BOXES/KEY CABINETS SHALL BE PROVIDED FOR ALL HIGH-RISE BUILDINGS, POOL
<br />ENCLOSURES, GATES IN THE PATH OF FIREFIGHTER TRAVEL TO STRUCTURES, SECURED
<br />PARKING LEVELS, DOORS GIVING ACCESS TO ALARM PANELS AND/OR ANNUNCIATORS,
<br />AND ANY OTHER STRUCTURES OR AREAS WHERE IMMEDIATE ACCESS IS REQUIRED OR
<br />IS UNDULY DIFFICULT. AN OCFA INSPECTOR CAN ASSIST WITH LOCKING GATE KEYS IN
<br />KNOX BOXES, CONTACT YOUR LOCAL FIRE STATION TO ARRANGE AN APPOINTMENT TO
<br />SECURE MASTER BUILDING KEYS IN THE KNOX BOX.
<br />8.APPROVAL OF THESE PLANS SHALL NOT PERMIT THE VIOLATION OF ANY CODE OR LAW.
<br />REQUIREMENTS OR FEATURES NOT IDENTIFIED ON THE PLAN MAY APPLY AND OCFA
<br />INSPECTORS MAY REQUIRE ADDITIONAL INFORMATION OR ITEMS FROM THOSE SHOWN
<br />ON THE PLAN DEPENDING ON ACTUAL OR ANTICIPATED FIELD CONDITIONS. SUCH
<br />CHANGES MAY NECESSITATE SUBMITTAL OF REVISED OR AS-BUILT PLANS TO THE OCFA
<br />AND THE CITY/COUNTY WHERE THE PROJECT IS LOCATED.
<br />GENERAL REQUIREMENTS
<br />9.THE PROJECT SHALL COMPLY WITH 2019 CALIFORNIA BUILDING CODE, 2019
<br />CALIFORNIA FIRE CODE, AND OTHER CURRENTLY ADOPTED CODES, STANDARDS,
<br />REGULATIONS AND REQUIREMENTS AS ENFORCED BY THE OCFA.
<br />10.APPROVAL OF THIS PLAN IS CONTINGENT UPON A CERTIFICATE OF OCCUPANCY BEING
<br />ISSUED UPON COMPLETION OF ALL CONSTRUCTION ON THE ENTIRE PROJECT. PHASED
<br />OCCUPANCY SHALL BE PERMITTED ONLY WITH PRIOR APPROVAL FROM OCFA AND THE
<br />BUILDING OFFICIAL. REQUESTS FOR PHASED OCCUPANCY SHALL BE SUBMITTED TO OCFA
<br />FOR EVALUATION AS AN ALTERNATE MATERIALS AND METHODS PROPOSAL
<br />ACCOMPANYING THE ARCHITECTURAL SUBMITTAL. SUCH REQUESTS SHALL BE MADE
<br />PRIOR TO START OF CONSTRUCTION ONLY.
<br />11.DUMPSTERS AND TRASH CONTAINERS EXCEEDING 1.5 CUBIC YARDS SHALL NOT BE
<br />STORED IN BUILDINGS OR PLACED WITHIN 5 FEET OF COMBUSTIBLE WALLS, OPENINGS
<br />OR COMBUSTIBLE ROOF EAVE LINES UNLESS PROTECTED BY AN APPROVED SPRINKLER
<br />SYSTEM OR LOCATED IN A TYPE I OR IIA STRUCTURE SEPARATED BY 10 FEET FROM
<br />OTHER STRUCTURES. CONTAINERS LARGER THAN 1 CUBIC YARD SHALL BE OF NON- OR
<br />LIMITED-COMBUSTIBLE MATERIALS OR SIMILARLY PROTECTED OR SEPARATED. CFC
<br />304.3
<br />12.EXITS, EXIT SIGNS, FIRE ALARM PANELS, HOSE CABINETS, FIRE EXTINGUISHER
<br />LOCATIONS, AND STANDPIPE CONNECTIONS SHALL NOT BE CONCEALED BY CURTAINS,
<br />MIRRORS, OR OTHER DECORATIVE MATERIAL.
<br />13.THE EGRESS PATH SHALL REMAIN FREE AND CLEAR OF ALL OBSTRUCTIONS AT ALL
<br />TIMES. NO STORAGE IS PERMITTED IN AISLES.
<br />14.EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR ANY
<br />SPECIAL KNOWLEDGE OR EFFORT. DOORS SHALL NOT BE PROVIDED WITH THUMB-TURN
<br />LOCKS OR DEADBOLTS THAT DO NOT UNLATCH IN TANDEM WITH THE NORMAL
<br />OPERATING LEVER. THE OPENING FORCE FOR INTERIOR DOORS WITHOUT CLOSERS
<br />SHALL NOT EXCEED 5 POUNDS. THE UNLATCHING AND OPENING FORCE FOR OTHER
<br />DOORS, INCLUDING FIRE DOORS, SHALL NOT EXCEED 15 POUNDS. CBC 1010
<br />15.THE EXIT PATH SHALL BE CLEARLY IDENTIFIED WITH EXIT SIGNS CONFORMING TO CBC
<br />1013. ILLUMINATED EXIT SIGNS MUST HAVE 90-MINUTE EMERGENCY POWER BACK-UP.
<br />16.TACTILE SIGNS SHALL BE PROVIDED IN COMMERCIAL BUILDINGS, PUBLIC
<br />BUILDINGS/ACCOMMODATIONS, AND PUBLICLY FUNDED HOUSING SUBJECT TO CBC
<br />CHAPTERS 11A AND B AND CONFORM TO 1143A OR 11B-703.1, -703.2, -703.3, AND
<br />703.5, BE MOUNTED WITH THE BOTTOM OF THE LOWEST LINE OF BRAILLE CHARACTERS
<br />AT LEAST 4 FEET ABOVE THE FLOOR BUT THE BOTTOM OF THE HIGHEST LINE OF RAISED
<br />TEXT CHARACTERS NO MORE THAN 5 FEET ABOVE THE FLOOR AND, WHENEVER
<br />POSSIBLE, ON THE STRIKE SIDE OF THE DOOR. LETTERING SHALL BE BETWEEN 5/8
<br />INCHES AND 2 INCHES HIGH. CBC 1013.4
<br />17.STAIRS SERVING 4+ STORIES SHALL HAVE STAIRWELL SIGNS CONFORMING TO CBC
<br />1023.9 AND OCFA GUIDELINE E-02.
<br />18.THE EXIT PATH SHALL BE ILLUMINATED AT ALL TIMES IN ACCORDANCE WITH CBC 1006.
<br />EMERGENCY LIGHTING SHALL BE PROVIDED WITH 90-MINUTE BACK-UP.
<br />19.RATED ASSEMBLIES SHALL CONFORM TO APPROVED METHODS AND MATERIALS OF
<br />CONSTRUCTION. PENETRATIONS THROUGH RATED WALLS, CEILINGS, OR FLOORS SHALL
<br />BE PROTECTED IN AN APPROVED MANNER COMPLYING WITH CBC/CFC CHAPTER 7.
<br />20.RATED DOORS SHALL BE SELF-CLOSING AND LATCHING; SUCH DOORS SHALL NOT BE
<br />EQUIPPED WITH DOOR STOPS OR OTHERWISE PROPPED OPEN. RATED DOORS SHALL BE
<br />EQUIPPED WITH RATED HARDWARE. CFC 703 PROJECT-SPECIFIC REQUIREMENTS
<br />ASSEMBLY OCCUPANCIES
<br />21.OCCUPANT LOAD SIGN, WITH MINIMUM ONE-INCH LETTERS AND NUMBERS
<br />CONTRASTING WITH THEIR BACKGROUND, SHALL BE POSTED IN A CONSPICUOUS
<br />LOCATION NEAR THE MAIN EXIT PER CBC 1004.3 AND TITLE 19 3.30. WHERE MULTIPLE
<br />SEATING CONFIGURATIONS OR USES ARE ANTICIPATED, SEATING DIAGRAMS AND THEIR
<br />RESPECTIVE OCCUPANT LOADS MAY ALSO BE REQUIRED TO BE POSTED.
<br />22.PANIC HARDWARE SHALL BE PROVIDED FOR ALL EXIT AND EXIT ACCESS DOORS IN
<br />ASSEMBLY OCCUPANCIES. SUCH DOORS SHALL SWING IN THE DIRECTION OF EXIT
<br />TRAVEL. DOORS EQUIPPED WITH PANIC HARDWARE SHALL HAVE NO OTHER LOCK OR
<br />LATCH EXCEPT PANIC HARDWARE. IF PANIC HARDWARE IS OMITTED ON THE MAIN DOOR
<br />WHEN PERMITTED BY CBC 1010.1.9.3, A SIGN STATING "THIS DOOR TO REMAIN
<br />UNLOCKED WHEN BUILDING IS -INCH LETTERS CONTRASTING WITH THEIR BACKGROUND
<br />SHALL BE POSTED IN A OCCUPIED? CONSPICUOUS LOCATION ON OR ADJACENT TO THE
<br />DOOR AND THE DOOR SHALL BE EQUIPPED ONLY WITH A KEY-OPERATED LOCK THAT
<br />VISUALLY INDICATES WHETHER IT IS OPEN OR LOCKED.
<br />23.TABLES SHALL BE SPACED AT LEAST 50 INCHES APART WHERE SEATING IS BACK TO
<br />BACK AND AISLE ACCESSWAYS SERVE MORE THAN 4 OCCUPANTS OR ARE LONGER THAN
<br />6 FEET. AISLE WIDTHS SHALL BE A MINIMUM OF 36 INCHES WHERE SEATING IS ONLY
<br />ON ONE SIDE OF THE AISLE OR 42 INCHES FOR SEATING ON BOTH SIDES. WHERE SEATS
<br />BACK UP INTO AISLES, SEAT BACKS SHALL BE LOCATED AT 19 INCHES FROM THE TABLE
<br />EDGE AND THE CLEAR AISLE WIDTH SHALL BE MEASURED FROM THE BACK OF THE SEAT.
<br />CBC 1029.12
<br />24.OPEN FLAME IN ASSEMBLY AREAS IS PROHIBITED EXCEPT AS SPECIFICALLY PERMITTED
<br />BY OCFA IN COMPLIANCE WITH CFC CHAPTER 3. EXTINGUISHING SYSTEMS
<br />25.AN AUTOMATIC FIRE SPRINKLER SYSTEM SHALL BE PROVIDED THROUGHOUT THE
<br />BUILDING IN COMPLIANCE WITH CFC 903 AND THE APPLICABLE 2016 NFPA SPRINKLER
<br />STANDARD. REVIEW AND APPROVAL OF A SPRINKLER PLAN IS REQUIRED PRIOR TO
<br />INSTALLATION OR MODIFICATION.
<br />26.AN AUTOMATIC EXTINGUISHING SYSTEM SHALL BE PROVIDED TO PROTECT
<br />COMMERCIAL-TYPE FOOD HEATING EQUIPMENT THAT PRODUCES GREASE-LADEN
<br />VAPORS AND SHALL COMPLY WITH 2016 CFC AND CMC AND 2009 NFPA 17A. REVIEW
<br />AND APPROVAL OF A HOOD AND DUCT EXTINGUISHING SYSTEM PLAN IS REQUIRED
<br />PRIOR TO INSTALLATION OR USE OF COOKING EQUIPMENT. ALARM AND MONITORING
<br />SYSTEMS
<br />27.A FIRE ALARM SYSTEM SHALL BE PROVIDED IN COMPLIANCE WITH CBC/CFC 907 AND
<br />2016 NFPA 72. A SEPARATE PLAN SUBMITTAL IS REQUIRED FOR APPROVAL PRIOR TO
<br />INSTALLATION OR MODIFICATION.
<br />28.AUTOMATIC FIRE SPRINKLER SYSTEM(S) AND ALL CONTROL VALVES, WITH THE
<br />EXCEPTION OF THOSE LISTED IN CFC 903.4, SHALL BE MONITORED BY A UL LISTED
<br />CENTRAL ALARM STATION. HAZARDOUS MATERIALS, EQUIPMENT, AND PROCESSES
<br />29.STORAGE, DISPENSING, OR USE OF ANY HAZARDOUS MATERIALS SHALL COMPLY WITH
<br />CBC 414 AND 415 AND CFC REGULATIONS. THE STORAGE AND USE OF HAZARDOUS
<br />MATERIALS SHALL BE REVIEWED AND APPROVED BY THE OCFA PRIOR TO SUCH
<br />MATERIALS BEING BROUGHT ON SITE. APPROPRIATE HAZARDOUS MATERIALS WARNING
<br />SIGNS SHALL BE PROMINENTLY PLACED IN THE VICINITY/ENTRANCES TO AREAS WHERE
<br />HAZARDOUS MATERIALS ARE STORED IN QUANTITIES SUFFICIENT TO REQUIRE A CFC
<br />PERMIT.
<br />30.HAZARDOUS PROCESSES AND EQUIPMENT (E.G., STORAGE TANKS, REFRIGERATION,
<br />VAPOR RECOVERY, SPRAY BOOTHS AND DRYING ROOMS, DIP TANKS, INDUSTRIAL
<br />OVENS, DUST COLLECTION SYSTEMS, MEDICAL/INDUSTRIAL GAS SYSTEMS, ETC) SHALL
<br />BE REVIEWED AND APPROVED BY THE OCFA PRIOR TO INSTALLATION. SUCH EQUIPMENT
<br />AND PROCESSES MAY REQUIRE SPECIFIC BUILDING FEATURES AND PROTECTION
<br />BEYOND WHAT IS IDENTIFIED ON THIS PLAN.
<br />31.BATTERY SYSTEMS WITH MORE THAN 50 GALLONS OF ELECTROLYTE (AGGREGATE
<br />QUANTITY) REQUIRE REVIEW AND APPROVAL BY OCFA PRIOR TO INSTALLATION.
<br />32.HIGH-PILED COMBUSTIBLE STORAGE SHALL BE IN ACCORDANCE WITH CFC CHAPTER 32.
<br />HIGH HAZARD MATERIALS CANNOT BE STORED HIGHER THAN 6 FEET AND OTHER
<br />MATERIALS CANNOT BE STORED HIGHER THAN 12 FEET WITHOUT FIRST SUBMITTING
<br />PLANS TO AND OBTAINING APPROVAL FROM THE OCFA. OTHER REQUIREMENTS
<br />33.AT LEAST ONE EMERGENCY ESCAPE AND RESCUE WINDOW SHALL BE PROVIDED FOR
<br />EVERY SLEEPING ROOM BELOW THE FOURTH STORY IN R OCCUPANCIES, EXCEPT IN
<br />R-1/R-2 OF TYPE I, IIA, IIIA, OR IV CONSTRUCTION. ACCESS TO RESCUE OPENINGS SHALL
<br />BE IN ACCORDANCE WITH OCFA GUIDELINES B-09 AND E-04. VEGETATION,
<br />TOPOGRAPHY, FENCES/WALLS AND OTHER OBSTRUCTIONS SHALL NOT IMPEDE
<br />LADDERING OF RESCUE OPENINGS OR THE PATH OF FIREFIGHTER TRAVEL FROM THE FIRE
<br />LANE TO SUCH OPENINGS. CBC 1030, CFC 504.1
<br />34.THE SMOKE CONTROL SYSTEM SHALL COMPLY WITH CBC/CFC 909 AND CFC
<br />REGULATIONS. REVIEW AND APPROVAL OF A RATIONAL ANALYSIS REPORT IS REQUIRED
<br />PRIOR TO COMMENCING CONSTRUCTION. ACCEPTANCE TESTING SHALL BE PERFORMED
<br />BY A QUALIFIED THIRD PARTY AND VERIFIED BY AN OCFA INSPECTOR PRIOR TO
<br />OCCUPANCY.
<br />35.PROJECTS LOCATED WITHIN A D.O.G.G.R. FIELD BOUNDARY, NEAR AN OIL/GAS WELL OR
<br />SEEP, OR OTHER LOCATIONS WITH A POTENTIAL FOR COMBUSTIBLE SOIL GAS SHALL
<br />UNDERGO EVALUATION AND POSSIBLE MITIGATION AS DESCRIBED IN OCFA GUIDELINE
<br />C-03.
<br />3419 Via Lido, Ste. 225
<br />Newport Beach, CA 92663
<br />949.500.9416 www.intrepid-group.net
<br />N E W F L O W E R
<br />R O O M
<br />1 8 2 1 N E W P O R T C I R C L E
<br />S A N T A A N A , C A 9 2 7 0 5
<br />ACS.1
<br />1821 E Newport Cir
<br />12/23/2024
|