105'-1" <br />89'-6" <br />54'-6" <br />111'-2" <br />26'-8" <br />18' <br />NO <br />PARKING <br />38' <br />3 2 1 <br />4567891011121314 <br />J <br />LANDSCAPE <br />J <br />LANDSCAPE <br />4' <br />4' <br />6' <br />COMMON <br />ENTRANCE <br />COMMON <br />EXIT <br />COMMON <br />EXIT <br />16 <br />8 <br />. <br />5 <br />0 <br />' <br />21 <br />0 <br />. <br />7 <br />5 <br />' <br />125.00' <br />(E) FIRE HYDRANT. DISTANCE FROM WEST <br />PROPERTY LINE TO HYDRANT = 20' <br />DISTANCE TO ADJACENT HYDRANT: 260' <br />(E) FIRE HYD <br />R <br />A <br />N <br />T <br />. <br /> <br />D <br />I <br />S <br />T <br />A <br />N <br />C <br />E <br /> <br />F <br />R <br />O <br />M <br /> <br />E <br />A <br />S <br />T <br /> <br />P <br />R <br />O <br />P <br />E <br />R <br />T <br />Y <br /> <br />L <br />I <br />N <br />E <br /> <br />T <br />O <br />HYDRANT = 1 <br />0 <br />8 <br />' <br />HYDRANT SIZ <br />E <br />: <br /> <br />6 <br />" <br /> <br />X <br /> <br />4 <br />" <br /> <br />X <br /> <br />2 <br />. <br />5 <br />" <br />(LOCATION O <br />F <br /> <br />H <br />Y <br />D <br />R <br />A <br />N <br />T <br /> <br />I <br />S <br /> <br />A <br />T <br /> <br />N <br />O <br />R <br />T <br />H <br /> <br />C <br />O <br />R <br />N <br />E <br />R <br /> <br />O <br />F <br /> <br />E <br />. <br /> <br />N <br />E <br />W <br />P <br />O <br />R <br />T <br /> <br />C <br />L <br />. <br />AND RITCHE <br />Y <br /> <br />S <br />T <br />. <br />) <br />20' <br />K <br />30' <br />K <br />46'-5" <br />CO2 <br />TANK <br />(N) MSB <br />E <br />SCALE: 3 <br />32" = 1'-0" <br />FIRE MASTER PLAN <br />N <br />PERIMETER CMU BLOCK WALL, 7'H. <br />A (E) FIRE HYDRANT, TYP. <br />FIRE MASTER PLAN KEYNOTES <br />CENTER LINE <br />PROPERTY LINE <br />A <br />SHEET NUMBER: <br />A.1.0a <br />REVISIONS <br />FIRE MASTER <br />PLAN <br />SHEET NAME: <br />PREPARED BY: <br />OWNER: <br />PROJECT: <br />STAMP:JOB NUMBER: <br />XXXXX <br />DATE: <br />00.00.00 <br />CONSULTANT: <br />ACCESSIBLE PATH OF TRAVEL <br />FIRE MASTER PLAN LEGEND <br />A <br />P H A S E 2 <br />T E N A N T I M P R O V E M E N T O F <br />1 2 1 N E W P O R T C I R C L E <br />S A N T A A N A , C A 9 2 0 5 <br />PROJECT SCOPE OF WORK <br />A.CHANGE OF USE AND OCCUPANCY. AND TENANT IMPROVEMENT TO AN EXISTING 1-STORY COMMERCIAL <br />BUILDING. NO ADDED SQUARE FOOTAGE. <br />1ST SUBMITTAL <br />SANTA ANA VENTURES, INC. <br />121 E. NEWPORT CIRCLE <br />SANTA ANA, CA 9205 <br />K (E) FIRE DEPARTMENT KNOX BOX. INSTALL 4'- 5' A.F.G. <br />E (E) ELECTRICAL MAIN SHUTOFF. <br />(E) FIRE HYDRANT, BENEFICIAL USE FIRE PROTECTION. <br />PROPERTY LOCATION: <br />1821 E. NEWPORT CIRCLE <br />SANTA ANA, CA 92705 <br />PARCEL NO. <br />403-071-04 <br />OCCUPANCY TYPES <br />F-1, B <br />GROSS FLOOR AREA (EXISTING STRUCTURE) <br />10,400 SQ. FT. <br />CONSTRUCTION: <br />CONSTRUCTION TYPE: III-B. <br />FIRE SPRINKLERS: NO <br />FIRE ALARM:YES <br />LEGAL OWNER: SANTA ANA VENTURES, INC. <br />1821 E. NEWPORT CIRCLE <br />SANTA ANA, CA 92705 <br />BUILDING AREA CALCULATIONS <br />A.CONSTRUCTION TYPE (CHAPTER 6):III-B <br />B.FULLY SPRINKLERED (CHAPTER 9):NO <br />C.ALLOWABLE (CHAPTER 5) <br />C.A.ALLOWABLE STORIES (TABLE 504.4)2 <br />C.B.ALLOWABLE HEIGHT (TABLE 504.3)55 FT. <br />C.C.ALLOWABLE FLOOR AREA (TABLE 506.2) <br />M OCC.: 12,500 SF <br />F-1 OCC: 12,000 SF <br />D.ACTUAL: <br />D.A.ACTUAL STORIES 1 <br />D.B.ACTUAL HEIGHT 19'-2" AFG <br />D.C.ACTUAL FLOOR AREA (TOTAL) <br />M OCC. : 4,768 SF. <br />F-1 OCC.: 5,414 SF. <br />NOTE: PER SECTION 508.4.2, SEPARATED OCCUPANCIES, SUM OF RATIOS DOES NOT EXCEED 1. <br />FIRE HYDRANT FLOW REQUIREMENTS <br />PER CFC TABLE B105.1 (2) REQUIRED FIRE FLOW RATE IS 2,250 GPM FOR 2-HOURS DURATION. <br />PROJECT INFORMATION <br />SITE <br />LOCATION <br />VICINITY MAP <br />INSPECTION REQUIREMENTS <br />1.OCFA site inspections are required for this project. Please schedule all field <br />inspections at least 48 hours in advance. Inspections canceled after 1 p.m. on <br />the day before the scheduled date will be subject to a re-inspection fee. Call <br />OCFA Inspection Scheduling at (714) 573-6150. <br />2.A lumber drop inspection shall be performed prior to bringing combustible <br />materials (or combustible fixtures and finishes for structures of <br />non-combustible construction). All-weather access roads capable of <br />supporting 94,000 lbs., topped with asphalt, concrete, or equivalent shall be in <br />place and hydrants operational at time of lumber drop inspection. <br />3.For projects with fuel modification, a vegetation clearance inspection is <br />required prior to a lumber drop inspection. Use the fuel modification plan <br />service request number to schedule the vegetation clearance inspection. <br />4.Phased installation of fire access roads requires additional inspections not <br />covered by the fees paid at plan submittal. Contact Inspection Scheduling to <br />arrange for additional inspections that may be needed and any fees that may <br />be due. <br />5.An original approved, signed, wet-stamped OCFA fire master plan shall be <br />available on-site at time of inspection. <br />6.Access roads and hydrants shall be maintained and remain clear of <br />obstructions at all times during and after construction. Areas where parking is <br />not permitted shall be clearly identified at all times. Obstruction of fire lanes <br />and hydrants may result in cancellation or suspension of inspections. <br />7.Temporary fuel tanks of 60 or more gallons shall be reviewed, inspected, and <br />permitted by the OCFA prior to use. <br />8.The project address shall be clearly posted and visible from the public road <br />during construction. <br />9.All gates in construction fencing shall be equipped with either a Knox or <br />breakaway padlock. <br />10.Buildings of four or more stories shall be provided with stairs and a standpipe <br />before reaching 40 feet in height. <br />GENERAL REQUIREMENTS <br />11.Fire lane widths shall be measured from top face of the curb to top face of the <br />curb for fire lanes with standard curbs and gutters and from flow-line to <br />flow-line for fire lanes with modified curb designs (e.g., rolled, ramped, etc.). <br />The developer is responsible to verify that all approved public works or <br />grading department street improvement plans or precise grading plans <br />conform to the minimum street width measurements per the approved OCFA <br />fire master plan and standards identified in OCFA Guideline B-09 for all <br />portions of the fire access roads. <br />12.Permanent, temporary, and phased emergency access roads shall be <br />designed and maintained to support an imposed load of 94,000 lbs. and <br />surfaced to provide all-weather driving capabilities. <br />13.Fire lane signs and red curbs shall meet the specifications shown in OCFA <br />Guideline B-09 and shall be installed as described therein. Additional fire lane <br />markings may be required at the time of inspection depending on field <br />conditions. <br />14.All fire hydrants shall have a “Blue Reflective Pavement Marker” indicating <br />their location per the OCFA standard. On private property markers are to be <br />maintained in good condition by the property owner. <br />15.Address numbers shall be located and be of a color and size so as to be <br />plainly visible and legible from the roadway from which the building is <br />addressed in accordance with OCFA Guideline B-09. Wayfinding signs, when <br />required by the local AHJ, shall comply with the standards of that agency. <br />When wayfinding signs are also required by the OCFA, they may be designed <br />to local AHJ requirements provided that such standards facilitate location of <br />structures, suites, and dwelling units by emergency personnel. <br />16.Access gates shall be approved prior to installation and shall be in compliance with <br />Chapter 5 of the CFC and OCFA guidelines. <br />17.Approved access walkways shall be provided to all required openings and all rescue <br />windows. <br />18.Vegetation shall be selected and maintained in such a manner as to allow <br />immediate access to all hydrants, valves, fire department connections, pull stations, <br />extinguishers, sprinkler risers, alarm control panels, rescue windows, and other <br />devices or areas used for firefighting purposes. Vegetation or building features shall <br />not obstruct address numbers or inhibit the functioning of alarm bells, horns, or <br />strobes. <br />19.Dumpsters and trash containers larger than 1.5 cubic yards shall not be stored in <br />buildings or placed within 5 feet of combustible walls, openings or combustible roof <br />eave lines unless protected by an approved sprinkler system. <br />20.Any future modification to the approved Fire Master Plan or approved site plan, <br />including but not limited to road width, grade, speed humps, turning radii, gates or <br />other obstructions, shall require review, inspection, and approval by the OCFA. <br />21.Approval of this plan shall not be construed as approval of any information or project <br />conditions other than those items and requirements identified in OCFA Guideline <br />B-09 and related portions of the 2016 CFC and CBC. This project may be subject to <br />additional requirements not stated herein upon examination of actual site and <br />project conditions or disclosure of additional information. <br />PROJECT-SPECIFIC REQUIREMENTS <br />22.An architectural plan is required to be submitted to the OCFA for review and <br />approval for projects containing A, C, E, F, H, I, L, and R-4 occupancies. A plan may <br />also be required for R-1 and R-2 occupancies over two stories or those utilizing <br />sprinklers or fire walls to increase the maximum building size allowed—see OCFA <br />Info Bulletin 02-13. <br />23.A chemical classification and hazardous materials compliance plan shall be <br />approved by the OCFA prior to any hazardous materials being stored or used on <br />site. A separate plan submittal is required. <br />24.Buildings used for high-piled storage shall comply with CFC requirements. A <br />separate plan submittal is required if materials will be stored higher than 12 feet for <br />lower-hazard commodities, or higher than six feet for high-hazard commodities such <br />as plastics, rubber, flammable/combustible liquids, tires, carpet, etc. <br />25.A fire alarm system shall be installed in accordance with applicable codes and local <br />ordinances, amendments, and guidelines. A separate plan submittal is required. <br />FIRE AUTHORITY NOTES <br />B (E) MANUAL SECURITY GATE. SEE 3/A.1.0a FOR NO PARKING SIGNAGE. <br />B <br />C (N) WALL MOUNTED, NO PARKING FIRE LANE SIGNAGE. SEE 2/A.1.0a. <br />C <br />FIRE LANE <br />18” <br />12” <br />NO <br />PARKING <br />VIOLATING VEHICLES <br />WILL BE CITED OR <br />TOWED AT OWNER’S <br />EXPENSE <br />CVC 22500.1 <br />CVC 22658(a) <br />2” bold, condensed <br />white reflective <br />lettering on red <br />background <br />2” bold, condensed <br />red lettering on <br />white reflective <br />background <br />1” red lettering on <br />white reflective <br />background <br />01 <br />SCALE <br />NTS02 WALL MOUNTED FIRE LANE NO PARKING SIGN <br />FIRE <br />LANE <br />18” <br />12” <br />NO <br />PARKING <br />2” bold, condensed <br />red lettering on <br />white reflective <br />background <br />SCALE <br />NTS03 GATE MOUNTED FIRE LANE NO PARKING SIGN <br />D <br />D (E) BUILDING MOUNTED ADDRESS NUMBERS. <br />DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN <br />CONSTITUTE ORIGINAL AND UNPUBLISHED WORK OF PD&C, INC. <br />dba RAND KRUSE AND MAY NO BE DUPLICATED, USED OR <br />DISCLOSED WITHOUT WRITTEN CONSENT OF PD&C, INC. dba <br />INTREPID GROUP. <br />3404 Via Oporto, Ste. 201 <br />Newport Beach, CA 92663 <br />949.500.9416 www.intrepid-group.net <br />1 PERMIT REVISION <br />SHEET SHOWN FOR <br />REFERENCE ONLY <br />1821 E Newport Cir <br />12/23/2024