My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1821 E Newport Cir - Plan
PBA
>
Building
>
ProjectDox
>
N
>
Newport Cir
>
1821 E Newport Cir
>
1821 E Newport Cir - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/5/2025 7:34:42 AM
Creation date
6/5/2025 7:34:25 AM
Metadata
Fields
Template:
Plan
Permit Number
20183508
30147555
40139341
101120205
Full Address
1821 E Newport Cir
Rectangle
ID:
1
Creator:
Import Agent
Created:
6/5/2025 7:34 AM
Modified:
6/4/2025 1:49 PM
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
65
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
C- <br />A <br />- <br />2 <br />0 <br />2 <br />3 <br /> <br />© <br />2 <br />0 <br />2 <br />3 <br /> <br />S <br />I <br />M <br />P <br />S <br />O <br />N <br /> <br />S <br />T <br />R <br />O <br />N <br />G <br />- <br />T <br />I <br />E <br /> <br />C <br />O <br />M <br />P <br />A <br />N <br />Y <br /> <br />I <br />N <br />C <br />. <br />131 <br />Me <br />c <br />h <br />a <br />n <br />i <br />c <br />a <br />l <br /> <br />An <br />c <br />h <br />o <br />r <br />s <br />SD <br />Simpson Strong-Tie® Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry <br />*See p. 14 for an explanation of the load table icons. <br />Titen Turbo™ Concrete and Masonry Screw Anchor <br />1 <br />Characteristic Symbol Units <br />Nominal Anchor Diameter (in.) <br />3/16 1/4 <br />Anchor Category 1, 2 or 3 —1 <br />Embedment Depth hnom in.1 3/4 1 3/4 <br />Steel Strength in Tension <br />Tension Resistance of Steel Nsa lb.1,640 2,640 <br />Strength Reduction Factor — Steel Failure2 φsa —0.65 <br />Concrete Breakout Strength in Tension <br />Effective Embedment Depth hef in.1.25 1.20 <br />Critical Edge Distance cac in.3 3 <br />Effectiveness Factor — Uncracked Concrete kuncr —24 <br />Modification Factor Ψc,N —1.0 <br />Strength Reduction Factor — Concrete Breakout Failure3 φcb —0.65 <br />Pullout Strength in Tension <br />Pullout Resistance Uncracked Concrete (f’c = 2,500 psi)5 Np,uncr lb.1,515 1,515 <br />Strength Reduction Factor — Pullout Failure4 φp —0.65 <br />1. The information presented in this table is to be used in conjunction with the design criteria of ACI 318-19 Chapter 17, <br />ACI 318-14 Chapter 17 or ACI 318-11 Appendix D. <br />The tabulated value of φsa applies when the load combinations of Section 1605.1 of the 2021 IBC, Section 1605.2 of the <br />2018, 2015, 2012, and 2009 IBC, ACI 318-19, ACI 318-14 Section 5.3 or ACI 318-11 Section 9.2 are used. If the load <br />combinations of ACI 318-11 Appendix C are used, the appropriate value of φ must be determined in accordance with <br />ACI 318-11 Section D.4.4. <br />The tabulated value of φcb applies when both the load combinations of Section 1605.1 of the 2021 IBC, Section 1605.2 of the <br />2018, 2015, 2012, and 2009 IBC, ACI 318-19, ACI 318-14 Section 5.3 or ACI 318-11 Section 9.2 are used and the requirements <br />of ACI 318-19 Section 17.5.3, ACI 318-14 Section 17.3.3 (c) or ACI 318-11 Section D.4.3, as applicable, for Condition B are met. <br />If the load combinations of ACI 318-11 Appendix C are used, the appropriate value of φ must be determined in accordance <br />with ACI 318-11 Section D.4.4 for Condition B. <br />The tabulated value of φp applies when both the load combinations of Section 1605.1 of the 2021 IBC, Section 1605.2 of the <br />2018, 2015, 2012, and 2009 IBC, ACI 318-19, ACI 318-14 Section 5.3 or ACI 318-11 Section 9.2 are used and the requirements <br />of ACI 318-19 Section 17.5.3, ACI 318-14 Section 17.3.3 (c) or ACI 318-11 Section D.4.3 (c) for Condition B are met. If the load <br />combinations of ACI 318-11 Appendix C are used, the appropriate value of φ must be determined in accordance with ACI 318-11 <br />Section D.4.4 for Condition B. <br />The characteristic pullout resistance for greater compressive strengths may be increased by multiplying the tabular value by <br />(f'c/2500)0.23 for 1/4" screw anchors. No increase in the characteristic pullout resistance for greater compressive strengths is <br />permitted for 3/16" screw anchors. <br />IBC * <br />1 <br />1821 E Newport Cir <br />12/23/2024
The URL can be used to link to this page
Your browser does not support the video tag.